HomeMy WebLinkAboutRES2003-03042 310 ONYX DR BUILDING PERMITCity of College S}-tion
WORK 3QUEST
REQ/JOB: WF0465055 / o0i PROJECT:
CREW:
LOCATION: 310 ONYX DR
77845
f PAGE 1
fflQ2�03
0203
13:26:06
DATES
10/02%03
GEN. LOC: COLLEGE STATION LOC ID: 198612
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: HERMAN COUCH ORIGIN: CUSTOMER -WALK IN
USER D: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE
3I%4" WATER 4" SEWER
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
"REQUEST DATE:
PRINT DATE:
PRINT TIME:
SCHEDULE
START:
COMPLETION:
PREPARED 2/17/04, 12:39:13 INSPECTION TICKET PAGE 7
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/17/04
------------------------------------------------------------------------------------------------
ADDRESS . : 310 ONYX DR SUBDIV: STONE FOREST PH 3
CONTRACTOR : HERMAN E COUCH - BUILDER PHONE : (979) 690-7813
OWNER : JOHNSON INVESTMENTS INC PHONE :
PARCEL : 585200-0304-0040
APPL NUMBER: 03-00003042 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 10/14/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00
10/14/03 AP 10/13/2003 12:36 PM GCARRILLO
STRINGS ON SETBACKS OK, FRONT GARAGE RT. ON. SLAB GROUND
MIDDLE OF LEFT SIDE WALL.
B115 01 11/21/03 TB BLDG, FRAMING TIME: 17:00
11/21/03 AP 11/20/2003 04:26 PM SSTANLEY
B125 01 2/1 /0 BLDG, FINAL TIME: 17:00
f (�� ��l t1v AP OC 02/17/2004 08:39 AM MALFORD
'----------------------------------- CONTINUED ONTO NEXT PAGE -----------------------------------
1 1 1
r`2,T i s vt 1 S f r5 k ec
Mandi Alford - Insulation request inspection result, 310 Onyx, #03-3042 ' Page 1
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 11/24/2003 10:25:29 AM
Subject: Insulation request inspection result, 310 Onyx, #03-3042
Print for File
Inspected Insulation, 310 Onyx, #03-3042, Couch Homes, 11-24-03
Inspection result: Inspected OK for Good Cents
CC: Alford, Mandi
City
of College
Station �•
WORK
REQUEST— �
PAGE
1
REQ/JOB:
WF0467210
/ 001 PROJECT:
REQUEST DATE:
10/14/03
PRINT DATE:
10/14/03
CREW:
PRINT TIME:
13:Fj'2:21
SCHEDULE
DATES#
LOCATION:
310 ONYX
DR
03
77845
COMPLETION:
10/14/03
GEN. LOC:
COLLEGE
STATION LOC ID: 198612
REF NBR:
REQ DEPT:
DE -BUILDING
INSPECTION PRIORITY:
NORMAL
REQUESTOR:
HERMAN E
COUCH ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSTANLEY
AUTH: SSTANLEY WORK TYPE:
ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
BUILDING PERMIT
�C If'O���A�T I ON
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00003042 Date 10/02/03
Property Address . . . . . . 310 ONYX DR
Property ID . . 585200-0304-0040
R # . . . . . . . . . . . . . R*****
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . STONE FOREST PH 3
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 150678
Owner Contractor
------------------------ ------------------------
JOHNSON INVESTMENTS INC HERMAN E COUCH - BUILDER
PO BOX 800 HERMAN E COUCH
COLEMAN TX 768340800 1282 STAUFFER CIRCLE
COLLEGE STATION TX 77845
(979) 690-7813
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 2283.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 252.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . GC
Permit Fee . . . . 613.00 Plan Check Fee .00
Issue Date . . . . 10/02/03 Valuation . . . . 150678
Expiration Date . . 3/31/04
Qty Unit Charge Per Extension
BASE FEE 460.00
51.00 3.0000 THOU BLDG, VAL 100001-500000 153.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
---- ---------- -- - - --------------------------
BUILDING DEPT F�RESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00003042
Page 2
Date 10/02/03
Special Notes and Comments
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR (S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . . . . . . . .
Fee summary Charged
Permit Fee Total
Plan Check Total
Other Fee Total
BUILDING I
APPLICANT:
SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Paid Credited Due
613.00 613.00 .00 .00
.00 .00 .00 .00
750.00 750.00 .00 .00
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 03-00003042
Grand Total 1363.00 1363.00
BUILDING DEPT/REPRESENTATIVE:
APPLI
Page 3
Date 10/02/03
.00 .00
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
03-00003048 Date
10/02/03
Property Address . . . . . .
310 ONYX DR
Property ID . . . . . . . . .
585200-0304-0040
Tenant nbr, name . . . . . .
TEMP POLE
Application description . . .
TEMP POLE
Subdivision Name . . . . . .
STONE FOREST PH 3
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
JOHNSON INVESTMENTS INC
------------------------
HERMAN E COUCH - BUILDER
PO BOX 800
HERMAN E COUCH
COLEMAN TX 768340800
1282 STAUFFER CIRCLE
COLLEGE STATION
TX 77845
(979) 690-7813
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . GC
Permit Fee . . . . 20.00
Issue Date . . . . 10/02/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE: -AA-(�A3 �I, ------
f
APPLICANT./Ji��,�—
E
APOLICATION FOR BUILDING PERMS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE -
COLLEGE STATION. TX 77840
(979) 764-3570 (979) 764-3496 FAX
WW W.Ci.COLLEG E-STATION.TX.US
ADDRESS/LOCATION:
L
LOT T BLOCK SUBDIVISION
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS:
w
Fa 0*1 use
DATE. y DS " V
APPLICATION #
TEMP POLE #
PHONE: 44 / O r ;10?,/ -2
PHONE: D
PLUMBER: 41-P ��.i►Ai
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION,OF WORK:
STRUCTURE USE: -
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 4, ' TOTAL AREA:.3p.1 % HEATED AREA a .3
(Cost of Labor and Materials)
Erp"'UBLIC SEWER 16Aj &7$ NUMBER OF BEDROOMS:
SEPTiGTREATMENT SYSTEM
SEWER TAP:
IZE
WATER TAP:
SIZE'
Q OTHER TAP:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
,SIZE
"TEMP POLE ROOF TYPE:
GARAGE TYPE: SINGLE a DOUBLE
ATTACHED Q DETACHED
TRIPLE a
CARPORT a
SIGNATURE OF APPLICANT:
Officla/ Use Only
oOIA03
Plans Examiner
Zoning Offidal
ants:
YE or NO