HomeMy WebLinkAboutRES2003-03021 3713 MEADOW VIEW DR BUILDING PERMITlow 11/04/03 CW 11/04/03 AP 12/18/03 DS 12/18/03 AP 1/22/04 CH 1/22/04 CA 1/26/04 1/27/04 2/24/04 PREPARED 2/24/04, 7:35:25 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/24/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3713 MEADOW VIEW DR SUBDIV: WESTFIELD ADDITION PH 2 CONTRACTOR : MAIN STREET HOMES PHONE : (979) OWNER : MAIN STREET HOMES CS LTD PHONE : PARCEL : 650700-0211-0070 APPL NUMBER: 03-00003021 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/03/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 11/03/03 DP 11/03/2003 08:04 AM MALFORD B100 02 B115 01 B130 01 B130 02 B125 01 11/03/2003 03:47 PM MALFORD NEES SLAB SURVEY , NEEDS TO FOX PLASTIC ON PADS , STIR UP CAN NOT MAKE CONTACT WITH EARTH BLDG, FOUNDATION -SLAB TIME: 17:00 11/03/2003 04:18 PM MALFORD BLDG, FRAMING TIME: 17:00 12/17/2003 12:46 PM SSTANLEY BLDG, INSULATION TIME: 17:00 O1/22/2004 09:38 AM GCARRILLO not ready OC BLDG, INSULATION TIME: 17:00 AP 01/23/2004 01:33 PM SSTANLEY D BI BLDG, FINAL TIME: 17:00 02/23/2004 03:42 PM GCARRILLO -------------------------------------- COMMENTS AND NOTES ------------------------------ /lj o i / / % 9)91 v J" 5yj �"�� ab City of College Station WORK REQUEST PAGE 1 REQ/JOB: WF0466383 / 001 PROJECT: REQUEST DPRINT ATE: 10%09f03 CREW: PRINT TIME: 11:14:12 LOCATION: 3713 MEADOW VIEW DR SCHSTART.DATES 10/09/03 77845 COMPLETION: 10/09/03 GEN. LOC: COLLEGE STATION LOC ID: 198304 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE PASSED ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task cone: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003053 Date 10/01/03 Property Address . . . . . . 3713 MEADOW VIEW DR Property ID . . . . . . . . . 650700-2201-0070 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD ADDITION PH 2B Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ MAIN STREET HOMES CS LTD MAIN STREET HOMES % MSH-CS INC RICK JENKINS PETER L DAVIS 7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150 AUSTIN TX 787464130 AUSTIN TX 78746 (979) ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 10/01/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ----------------- ---------- Permit Fee Total 20.00 Other Fee Total 45.00 Grand Total 65.00 Paid Credited Due ------------------------------ 20.00 .00 .00 45.00 .00 .00 65.00 .00 .00 BUILDING DEPT REPRESEN IVE: APPLICANT: o�i QF CO , EGE STAT 1101 TEX.AS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003021 Date 10/01/03 Property Address . . . . . . 3713 MEADOW VIEW DR Property ID . . . . . . . . . 650700-2201-0070 R# . . . . . . . Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD ADDITION PH 2B Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 100650 Owner Contractor ------------------------ MAIN STREET HOMES ------------------------ CS LTD MAIN STREET HOMES % MSH-CS INC RICK JENKINS PETER L DAVIS 7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150 AUSTIN TX 787464130 AUSTIN TX 78746 (979) -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE POST TENSION NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1573.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 463.00 Plan Check Fee .00 Issue Date . . . . 10/01/03 Valuation . . . . 100650 Expiration Date . . 3/30/04 Qty Unit Charge Per Extension BASE FEE 460.00 1.00 3.0000 THOU BLDG, VAL 100001-500000 3.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER (S ) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT --------------------------------------------- -7� BUILDING DEPT REP NT'A�TjIVE APPLICANT: i����' / BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003021 Page 2 Date 10/01/03 Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Other Fees . . . . . . . . . Fee summary Charged SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Paid Credited Due Permit Fee Total 463.00 463.00 Plan Check Total .00 .00 Other Fee Total 750.00 750.00 BUILDING DEPT REPRESENTATIVE: APPLICANT: .00 .00 .00 .00 .00 .00 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003021 Grand Total 1213.00 1213.00 BUILDING DEPT REPRES APPLICANT: Page 3 Date 10/01/03 .00 .00 City of College S{-�tion WORK QUEST PAGE 1 REQ/JOB: WF0464805 / 001 PROJECT: REQUEST DPRINT ATE: 10f01/03 CREW: PRINT TIME: 14:36:21 SCHSTAARR.T.DATES LOCATION: 3713 MEADOW VIEW DR 10/01/03 77845 COMPLETION: 10/01/03 GEN. LOC: COLLEGE STATION LOC ID: 198304 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN USER : MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3 4"WTR, ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 411SWR 3/4"WTR, 4"SWR Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: 3? J3 m6abazA u jao LOT BLOCK SUBDIVISION Westfield not *Use ly DATE: �6 aPPucATION TEMP POLE # BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: Main Street Homes PHONE: (512) 327-8620 CONTRACTOR ADDRESS: 7447 Bee Cave Rd., Austin, TX 78746 ELECTRICIAN: Hillco Electric HVAC: Barkers HVAC PLUMBER: CP Plumbing GOOD CENTS (Residential only): CLASS OF WORK " ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY \ DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Construct Single Family Residence STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: 2 �p TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ 1(p 3 VALUATION: $ 10 Q& S0 TOTAL AREA: /9 7 HEATED AREA: 1573 (Cost ofBabor and Materials) D PUBLIC SEWER SEPTIC/TREATMENT SYSTEM 350 49v ® SEWER TAP: 4" 00 SIZE yl/� X❑ WATER TAP: 3 / 4" S¢E NUMBER OF BEDROOMS: 3 NUMBER OF BATHROOMS: 2- & INTERIOR WALL TYPE: Wood / Sheetrock EXTERIOR WALL TYPE: Wood/ Masonry OTHER TAP: FOUNDATION TYPE: Post Tension on Grade SVE TEMP POLE ROOF TYPE: Asphalt Shingles GARAGE TYPE: SINGLE a DOUBLE ® TRIPLE a ATTACHED ® DETACHED F__j CARPORT SIGNATURE OF APPLICANT: Official Use Only Comments: YES or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls 1!r7� Insulation R value of ceiling 1 (flat areas) 30 RP Insulation R value of ceiling 2 (vaulted areas/no attic) -z Glazing SHGC F 3 Glazing U-Factor R value of ductwork G A/C SEER rating / Z