HomeMy WebLinkAboutRES2003-03018 2025 RAVENSTONE LOOP BUILDING PERMITPREPARED 2/05/04, 12:00:21 INSPECTION TICKET PAGE 3
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/05/04
------------------------------------------------------------------------------------------------
ADDRESS . : 2025 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC 1 PH 2
CONTRACTOR : CLAY COLBY HOMEBUILDERS PHONE : (979) 777-9840
OWNER : GREENS PRAIRIE INVESTORS LTD PHONE :
PARCEL : 184200-2102-0340
APPL NUMBER: 03-00003018 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PBRMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 10/09/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00
10/09/03 CA 10/09/2003 08:17 AM GCARRILLO
10/09/2003 01:30 PM MALFORD
canceled per clay colby
B100 02 10/10/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00
10/10/03 AP 10/09/2003 01:30 PM MALFORD
STRINGS ON SETBACKS OK. SLAB GROUND BACK WALL OF GARAGE.
B115 01 11/03/03 TB BLDG, FRAMING TIME: 17:00
11/03/03 AP 11/03/2003 07:48 AM MALFORD
11/03/2003 04:46 PM MALFORD
• needs to firestop around top of fireplace w/ sheetrock
B125 01 2/05/04 BI BLDG, FINAL TIME: 17:00
02/05/2004 10:02 AM MALFORD _ �j ,
----------------------------------- CONTINUED ONTO NEXT PAGE --------------------- -�`-
of uc y
03..'-Ick
City
of College Station
WORK REQUEST
PAGE
1
REQ/JOB:
WF0466073 / 001 PROJECT:
REQUEST DATE:
10/08/03
PRINT DATE:
10/08/03
CREW:
PRINT TIME:
12:23:36
SCHSTAARRT.DATES
LOCATION:
2025 RAVENSTONE LOOP
10/08/03
77845
COMPLETION:
10/08/03
GEN. LOC:
COLLEGE STATION LOC ID: 193384
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
CLAY COLBY HOMEBUILDERS ORIGIN:
CUSTOMER -WALK
IN
USER ID:
GCARRILLO AUTH: GCARRILLO WORK TYPE:
ROUTINE
TEMP POLE APPROVED
TEMP POLE APPROVED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
------------------------------------------------------------
im
w
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 11/4/2003 2:26:24 PM
Subject: Insulation request inspection result, 2025 Ravenstone, #03-3018
Print for File
Inspected insulation, 2025 Ravenstone, #03-3018, Kolby Homes, 11-4-03
Inspection result: Inspected OK for Good Cents
CC: Alford, Mandi
i
V `
BUILD.'.'.7G PERMIT r
a
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 ' FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00003018 Date 9/29/03
Property Address . .
. . . . 2025 RAVENSTONE LOOP
Property ID
. . 184200-2102-0340
R # . . . . . . . . .
. . . . R111216
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CASTLEGATE SEC 1 PH 2
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . PLANNED DEVL HOUSING
Application valuation
. . . . 147346
Owner
Contractor
------------------------ ------------------------
GREENS PRAIRIE INVESTORS LTD CLAY VOLBY HOMEBUILDERS
4490 CASTLEGATE DR
P 0 BOX 8
COLLEGE STATION TX 778453388 NAVASOTA TX 77868
(979) 777-9840
--------------------------
Structure Information -------------------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 2231.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
SS
Permit Fee . . . .
604.00 Plan Check Fee .00
Issue Date . . . .
9/29/03 Valuation . . . . 147346
Expiration Date . .
3/28/04
Qty Unit Charge
Per Extension
BASE FEE 460.00
48.00 3.0000
THOU BLDG, VAL 100001-500000 144.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE CHEMICAL SOIL
TREATMENT OR PHYSICAL BARRIER (S CH
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEIAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 03-00003018
Page 2
Date 9/29/03
Special Notes and Comments
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . . . . . . . .
Fee summary Charged
SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Paid Credited Due
Permit Fee Total 604.00 604.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 750.00 750.00 .00 .00
BUILDING DEPT REPRESENTATIVE:
APPLICANT: A Kv�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00003018
Grand Total 1354.00 1354.00
Page 3
Date 9/29/03
.00 .00
------------------------------------------------ I --- --- ( -------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: CL-1.
��
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . .
. . .
03-00003019
Date 9/29/03
Property Address . . .
. . .
2025 RAVENSTONE LOOP
Property ID . . . . . .
. . .
184200-2102-0340
Tenant nbr, name . . .
. . .
TEMP POLE
Application description
. . .
TEMP POLE
Subdivision Name . . .
. . .
CASTLEGATE SEC 1 PH 2
Property Use . . . . .
. . .
RESIDENTIAL
Property Zoning . . . .
. . .
PLANNED DEVL HOUSING
Application valuation .
. . .
0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
LTD
------------------------
CLAY COLBY HOMEBUILDERS
4490 CASTLEGATE DR
P 0 BOX 8
COLLEGE STATION TX
778453388
NAVASOTA
TX 77868
(979) 777-9840
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . SS
Permit Fee . . . .
20.00
Issue Date . . . .
9/29/03
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . . . . .
. . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
Paid Credited
--------------------
Due
----------
---------------------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
---------------------------------------------------- -�v� ---------------
BUILDING DEPT RAPRESENTATIVE:
APPLICANT:
CITY OF COLLEGE STATION
WORM QUEST PAGE 1
REQ/JOB: WF0464101 / 001 PROJECT: REQUEST DATE:
9/29/PRINT 03
CREW: PRINT TIME: 14:21:35
LOCATION: 2025 RAVENSTONE LOOP SCHSTART,DATES 9/29/03
77845 COMPLETION: 9729703
GEN. LOC: COLLEGE STATION LOC ID: 193384
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: CLAY COLBY HOMEBUILDERS ORIGIN: CUSTOMER -WALK IN
USER D: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
3/4" WATER 4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1:3 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(079) 7644W0 (979) 764-3496 FAX
WWW.CI.COII E-STATION.TX.US
ADDRESS/LOCATION: ZC)Z -
LOT 1 BLOCK ^7SUB D ISION C/ry O'/If'f
BUSINESS/OWNER NAME:
CONTRACTOR ADDRESS
ELECTRICIAN: _
-Ha/-AG-
ACCESSORY!.
ADDITION
DEMOLITION (,
DUPLEX (Land,
Req)
DESCRIPTION OF
STRUCTURE USE:
HOMEOWNER ASSOCIA ON f 'l
TEXAS ACCESSIBILITY S ANC
VALUATION: $
(Cost of Labo
PUBLIC SEWER
VPTIC/TREATMENT SYS R TAP:
S
WATER TAP: 3 t
S12
O TAP:
S
TEMP POLE
GARAGE TYPE: f S
A
- 6 - ac cb A' s-CTA
PLUMBER: 1,
GOOD CENTS( e
CLASS OF WORK
LOCATION
VING
NEW CONSTRUCTION
REMODEL/RENOVATIO�J
DATE: s 4R b- 03
A
APPLICATION #
TEMP POLE # L `�� U
PHONE:
PHONE: -1-2^7-JI'9410
only):
RE -ROOF (Total/Partial)
SHELL ONLY
SLAB ONLY
SWIMMING POOL
GITLy�,t�t iT�=td?V
C rp Gj� R_6� jjr_
' r
RC
ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
kR
(TASKK J€i✓ REGISTRATION# EASPRJ
('
_. -- TOTAL AREA: '3330
HEATED AREA: Z7-3
i
aterWs)
NUMBER OF BEDROOMS:
q
z 1 Z'
1
BER OF BATHROOMS:
INTERI WALLTYPE:
I Z ` drel cK,
/I
EXTERI ALL TYPE:
�ZICI-
FOUNDATION E:
6>°i" o�ll G�.d2aC
ROOF TYPE:
30'4R- C.j)-
.EQ
OUBLE TRIPLES
I�J
1ED DETACHED � CARPORT
SIGNATURE OF APPLICANT:
1 Or�c�a, use Only
ents:
YE or NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls - i Z-3
Insulation R value of exterior walls /(Q. (e
Insulation R value of ceiling 1 (flat areas) 3D
Insulation R value of ceiling 2 (vaulted areas/no attic) Iq
Glazing SHGC , 3 6
Glazing U-Factor
R value of ductwork
(�
A/C SEER rating
l Z
REScheck Compliance Certificate
2000 IECC
REScheckSoflware Version 3.5 Release Id
Data filename: C:\Program Files\Check\REScheckUob 100.rck
PROJECT TITLE: 2025 Ravenstone Loop
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 09/19/03
DATE OF PLANS: 9/19/03
PROJECT DESCRIPTION:
New Residence
DESIGNER/CONTRACTOR:
Clay Kolby Homebuilding
COMPLIANCE: Passes
Maximum UA = 612
Your Home UA = 377
38.4% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall 1: Wood Frame,16" o.c.
Window 1: Metal Frame:Double Pane with Low E
SHGC: 0.36
Door 1: Solid
Door 2: Solid
Furnace 1: Forced Hot Air, 78 AFUE
Air Conditioner 1: Electric Central Air, 12 SEER
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R Value R-Value U Factor UA
2061
19.0 30.0 41
167
19.0 0.0 9
2371
16.6 0.0 130
292
0.640 187
24
0.310 7
18
0.150 3
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release ld (formerly MECchecj� and to comply with the mandatory requirements listed in
the REScheckInspection Checklist.
Builder/Designer ` Date �. J 7� ^ ° 3
REScheck Inspection Checklist
2000 IECC
REScheckSoflware Version 3.5 Release Id
DATE: 09/19/03
PROJECT TITLE: 2025 Ravenstone Loop
Bldg.
Dept.
Use
Ceilings:
[ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss,
R 19.0 cavity + R 30.0 continuous insulation
Comments:
[ } I 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] I 1. Wall 1: Wood Frame, 16" o.c., R-16.6 cavity insulation
Comments:
Windows:
[ ] I 1. Window 1: Metal Frame:Double Pane with Low E, U-factor. 0.640
For windows without labeled U factors, describe features:
I # Panes Frame Type Thermal Break? [ } Yes [ } No
Comments:
I
Doors:
[ ] I 1. Door 1: Solid, U-factor: 0.310
Comments:
[ ] I 2. Door 2: Solid, U factor: 0.150
Comments:
I
Heating and Cooling Equipment:
[ } I 1. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
{ ] I 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ l I T w area weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
I
Air Leakage:
[ l I Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed
[ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
I 3" clearance from insulation.
Materials Identification:
[ l I Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] I Materials and equipment must be identified so that compliance can be determined
[ l I Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided
[ l I Insulation R values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] I Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R 8.0.
I
Duct Construction:
[ l I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic plus -embedded -fabric, or tapes. Duct tape is not permitted.
I Exception: Continuously welded and locking type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided
I
Service Water Heating:
[ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ l I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] I HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in
Inches by Pipe
Sizes
Heated Water
Non -Circulating Runouts
Circulating Mains
and Runouts
Temperature ( F)
UP to "
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F) 2" Runouts I" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low FressurePTemperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
CLAY KOLBY
HOMEBUILDiNG
(979)777-9840
83.15'
Subdivision: Castlegate
Address: 2025 Ravenstone Loop • "••' ..
Lot: 34 Block: 2 See. 1 Ph 2 %• °� : • :, �J
laK,y •'r
71.70' '•
• yam` MAX