Loading...
HomeMy WebLinkAboutRES2003-03018 2025 RAVENSTONE LOOP BUILDING PERMITPREPARED 2/05/04, 12:00:21 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/05/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 2025 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC 1 PH 2 CONTRACTOR : CLAY COLBY HOMEBUILDERS PHONE : (979) 777-9840 OWNER : GREENS PRAIRIE INVESTORS LTD PHONE : PARCEL : 184200-2102-0340 APPL NUMBER: 03-00003018 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PBRMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/09/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 10/09/03 CA 10/09/2003 08:17 AM GCARRILLO 10/09/2003 01:30 PM MALFORD canceled per clay colby B100 02 10/10/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 10/10/03 AP 10/09/2003 01:30 PM MALFORD STRINGS ON SETBACKS OK. SLAB GROUND BACK WALL OF GARAGE. B115 01 11/03/03 TB BLDG, FRAMING TIME: 17:00 11/03/03 AP 11/03/2003 07:48 AM MALFORD 11/03/2003 04:46 PM MALFORD • needs to firestop around top of fireplace w/ sheetrock B125 01 2/05/04 BI BLDG, FINAL TIME: 17:00 02/05/2004 10:02 AM MALFORD _ �j , ----------------------------------- CONTINUED ONTO NEXT PAGE --------------------- -�`- of uc y 03..'-Ick City of College Station WORK REQUEST PAGE 1 REQ/JOB: WF0466073 / 001 PROJECT: REQUEST DATE: 10/08/03 PRINT DATE: 10/08/03 CREW: PRINT TIME: 12:23:36 SCHSTAARRT.DATES LOCATION: 2025 RAVENSTONE LOOP 10/08/03 77845 COMPLETION: 10/08/03 GEN. LOC: COLLEGE STATION LOC ID: 193384 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: CLAY COLBY HOMEBUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE TEMP POLE APPROVED TEMP POLE APPROVED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE ------------------------------------------------------------ im w From: Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 11/4/2003 2:26:24 PM Subject: Insulation request inspection result, 2025 Ravenstone, #03-3018 Print for File Inspected insulation, 2025 Ravenstone, #03-3018, Kolby Homes, 11-4-03 Inspection result: Inspected OK for Good Cents CC: Alford, Mandi i V ` BUILD.'.'.7G PERMIT r a COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 ' FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003018 Date 9/29/03 Property Address . . . . . . 2025 RAVENSTONE LOOP Property ID . . 184200-2102-0340 R # . . . . . . . . . . . . . R111216 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 1 PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 147346 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD CLAY VOLBY HOMEBUILDERS 4490 CASTLEGATE DR P 0 BOX 8 COLLEGE STATION TX 778453388 NAVASOTA TX 77868 (979) 777-9840 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2231.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 604.00 Plan Check Fee .00 Issue Date . . . . 9/29/03 Valuation . . . . 147346 Expiration Date . . 3/28/04 Qty Unit Charge Per Extension BASE FEE 460.00 48.00 3.0000 THOU BLDG, VAL 100001-500000 144.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER (S ) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (S CH BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEIAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 03-00003018 Page 2 Date 9/29/03 Special Notes and Comments AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Other Fees . . . . . . . . . Fee summary Charged SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Paid Credited Due Permit Fee Total 604.00 604.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: A Kv� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00003018 Grand Total 1354.00 1354.00 Page 3 Date 9/29/03 .00 .00 ------------------------------------------------ I --- --- ( ------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: CL-1. �� TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00003019 Date 9/29/03 Property Address . . . . . . 2025 RAVENSTONE LOOP Property ID . . . . . . . . . 184200-2102-0340 Tenant nbr, name . . . . . . TEMP POLE Application description . . . TEMP POLE Subdivision Name . . . . . . CASTLEGATE SEC 1 PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ CLAY COLBY HOMEBUILDERS 4490 CASTLEGATE DR P 0 BOX 8 COLLEGE STATION TX 778453388 NAVASOTA TX 77868 (979) 777-9840 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 9/29/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited -------------------- Due ---------- --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------------------------------- -�v� --------------- BUILDING DEPT RAPRESENTATIVE: APPLICANT: CITY OF COLLEGE STATION WORM QUEST PAGE 1 REQ/JOB: WF0464101 / 001 PROJECT: REQUEST DATE: 9/29/PRINT 03 CREW: PRINT TIME: 14:21:35 LOCATION: 2025 RAVENSTONE LOOP SCHSTART,DATES 9/29/03 77845 COMPLETION: 9729703 GEN. LOC: COLLEGE STATION LOC ID: 193384 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: CLAY COLBY HOMEBUILDERS ORIGIN: CUSTOMER -WALK IN USER D: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3/4" WATER 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1:3 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (079) 7644W0 (979) 764-3496 FAX WWW.CI.COII E-STATION.TX.US ADDRESS/LOCATION: ZC)Z - LOT 1 BLOCK ^7SUB D ISION C/ry O'/If'f BUSINESS/OWNER NAME: CONTRACTOR ADDRESS ELECTRICIAN: _ -Ha/-AG- ACCESSORY!. ADDITION DEMOLITION (, DUPLEX (Land, Req) DESCRIPTION OF STRUCTURE USE: HOMEOWNER ASSOCIA ON f 'l TEXAS ACCESSIBILITY S ANC VALUATION: $ (Cost of Labo PUBLIC SEWER VPTIC/TREATMENT SYS R TAP: S WATER TAP: 3 t S12 O TAP: S TEMP POLE GARAGE TYPE: f S A - 6 - ac cb A' s-CTA PLUMBER: 1, GOOD CENTS( e CLASS OF WORK LOCATION VING NEW CONSTRUCTION REMODEL/RENOVATIO�J DATE: s 4R b- 03 A APPLICATION # TEMP POLE # L `�� U PHONE: PHONE: -1-2^7-JI'9410 only): RE -ROOF (Total/Partial) SHELL ONLY SLAB ONLY SWIMMING POOL GITLy�,t�t iT�=td?V C rp Gj� R_6� jjr_ ' r RC ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: kR (TASKK J€i✓ REGISTRATION# EASPRJ (' _. -- TOTAL AREA: '3330 HEATED AREA: Z7-3 i aterWs) NUMBER OF BEDROOMS: q z 1 Z' 1 BER OF BATHROOMS: INTERI WALLTYPE: I Z ` drel cK, /I EXTERI ALL TYPE: �ZICI- FOUNDATION E: 6>°i" o�ll G�.d2aC ROOF TYPE: 30'4R- C.j)- .EQ OUBLE TRIPLES I�J 1ED DETACHED � CARPORT SIGNATURE OF APPLICANT: 1 Or�c�a, use Only ents: YE or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls - i Z-3 Insulation R value of exterior walls /(Q. (e Insulation R value of ceiling 1 (flat areas) 3D Insulation R value of ceiling 2 (vaulted areas/no attic) Iq Glazing SHGC , 3 6 Glazing U-Factor R value of ductwork (� A/C SEER rating l Z REScheck Compliance Certificate 2000 IECC REScheckSoflware Version 3.5 Release Id Data filename: C:\Program Files\Check\REScheckUob 100.rck PROJECT TITLE: 2025 Ravenstone Loop CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 09/19/03 DATE OF PLANS: 9/19/03 PROJECT DESCRIPTION: New Residence DESIGNER/CONTRACTOR: Clay Kolby Homebuilding COMPLIANCE: Passes Maximum UA = 612 Your Home UA = 377 38.4% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame,16" o.c. Window 1: Metal Frame:Double Pane with Low E SHGC: 0.36 Door 1: Solid Door 2: Solid Furnace 1: Forced Hot Air, 78 AFUE Air Conditioner 1: Electric Central Air, 12 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R Value R-Value U Factor UA 2061 19.0 30.0 41 167 19.0 0.0 9 2371 16.6 0.0 130 292 0.640 187 24 0.310 7 18 0.150 3 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release ld (formerly MECchecj� and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer ` Date �. J 7� ^ ° 3 REScheck Inspection Checklist 2000 IECC REScheckSoflware Version 3.5 Release Id DATE: 09/19/03 PROJECT TITLE: 2025 Ravenstone Loop Bldg. Dept. Use Ceilings: [ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R 19.0 cavity + R 30.0 continuous insulation Comments: [ } I 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: [ ] I 1. Wall 1: Wood Frame, 16" o.c., R-16.6 cavity insulation Comments: Windows: [ ] I 1. Window 1: Metal Frame:Double Pane with Low E, U-factor. 0.640 For windows without labeled U factors, describe features: I # Panes Frame Type Thermal Break? [ } Yes [ } No Comments: I Doors: [ ] I 1. Door 1: Solid, U-factor: 0.310 Comments: [ ] I 2. Door 2: Solid, U factor: 0.150 Comments: I Heating and Cooling Equipment: [ } I 1. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number { ] I 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number Solar Heat Gain Coefficient: [ l I T w area weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: [ l I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed [ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a I 3" clearance from insulation. Materials Identification: [ l I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined [ l I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided [ l I Insulation R values, glazing U-factors, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] I Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R 8.0. I Duct Construction: [ l I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic plus -embedded -fabric, or tapes. Duct tape is not permitted. I Exception: Continuously welded and locking type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ l I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) UP to " Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F) 2" Runouts I" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low FressurePTemperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) CLAY KOLBY HOMEBUILDiNG (979)777-9840 83.15' Subdivision: Castlegate Address: 2025 Ravenstone Loop • "••' .. Lot: 34 Block: 2 See. 1 Ph 2 %• °� : • :, �J laK,y •'r 71.70' '• • yam` MAX