HomeMy WebLinkAboutRES2003-02992 2019 RAVENSTONE LOOP BUILDING PERMITPREPARED 10/29/04, 8:00:41 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/29/04
------------------------------------------------------------------------------------------------
ADDRESS . : 2019 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC 1 PH 2
CONTRACTOR : ED FROEHLING BUILDERS PHONE : (979) 776-8266
OWNER : GREENS PRAIRIE INVESTORS LTD PHONE :
PARCEL : 184200-2102-0370
APPL NUMBER: 03-00002992 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMLT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 11/07/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
11/07/03 AP 11/07/2003 08:34 AM SSTANLEY
11/10/2003 06:56 AM MALFORD
setbacks per strings, slab ground Q right back
B115 01 12/18/03 TB BLDG, FRAMING TIME: 17:00
12/18/03 AP 12/17/2003 12:43 PM SSTANLEY
B130 01 12/29/03 CH BLDG, INSULATION TIME: 17:00
12/29/03 AP 12/29/2003 09:01 AM GCARRILLO
seal corners
seal corners
B125 01 10/ 9/04 BI BLDG, FINAL TIME: 17:00
O fqq roq Alp 001 10/28/2004 04:55 PM SSTANLEY
-------------------------------------- COMMENTS AND NOTES-----------------------------------
��^ 1 n
Ski E+ cY
BUILDING PERMIT
►�-��' 1101 TEXAS AVE '
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00002992
Date 10/02/03
Property Address . . .
. . . 2019 RAVENSTONE LOOP
Property ID
184200-2102-0370
R # . . . . . . .
R111219
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . CASTLEGATE.SEC 1 PH 2
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . PLANNED DEVL HOUSING
Application valuation .
. . . 168564
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD ED FROEHLING BUILDERS
4490 CASTLEGATE DR
ED FROEHLING
COLLEGE STATION TX
778453388 3887 HIGH LONESOME RD
COLLEGE STATION
TX 77845
(979) 776-8266
------ Structure Information
SINGLE FAMILY
----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2554.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
5.00
SEWER TYPE
PUBLIC
SERIAL ZONES
249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . SS
Permit Fee . . . .
667.00 Plan Check Fee
.00
Issue Date . . . . 10/02/03
Valuation . .
. . 168564
Expiration Date . .
3/31/04
Qty Unit Charge Per Extension
BASE FEE 460.00
69.00 3.0000 THOU BLDG, VAL 100001-500000 207.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
BUILDING DE�ftkkj
PT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 03-00002992
Page 2
Date 10/02/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . . . . . . . .
Fee summary Charged
SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Paid Credited Due
Permit Fee Total 667.00 667.00 .00 .00
Plan Check Total .00 .00 0 .00
BUILDING DEPT REPRESENTATIVE:
APPLICANT: NAqWK,)
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00002992
Other Fee Total 750.00 750.00
Grand Total 1417.00 1417.00
BUILDING DE9WWxkj
PTREPRESENTATIVE:
APPLICANT:
Page 3
Date 10/02/03
.00 .00
.00 .00
City
of College Station
WORK QUEST
PAGE
1
REQ/JOB:
WF0465079 / u01 PROJECT:
REQUEST DATE:
10/02/03
PRINT DATE:
10/02/03
CREW:
PRINT TIME:
14:06:01
SCHEDULE
LOCATION:
2019 RAVENSTONE LOOP
START:DATES
10/02/03
77845 COMPLETION:
10/02/03
GEN. LOC:
COLLEGE STATION LOC
ID: 193390
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
ED FROEHLING
ORIGIN: CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY
WORK TYPE: ROUTINE
3/4" WATER 4" SEWER
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
For O?iae use Onf i1 \
APPLICATION FOR BUILDING PERMIT ATE: q,
CITY OF COLLEGE STATION PLICATION #
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEM OLE #
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX.US
ADDRESS/L CATION l_D C.vo
LOT BLOCK Z SUBDIVISION_( .�j'7G z��fL / SEC/PH�
BUSIN61 OWNER NAME:
PHONE:
CONTRACTOR/HOMEOWNER: 15p PHONE:�76 •49aC
CONTRACTOR ADDRESS: 399Z *te3N L.Q& s ue' /21a
ELECTRICIAN: 84--s f T/�lc. PLUMBER: 17RIpi'l4 S" ,PLU/?713Y,v4r
HVAC: �'� I aAAQy-AV GOOD CENTS (Residentlal only): 6lA
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) EW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE: 6 )N4 t+6
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) P OJECT REGISTRATION# EABPRJ f 44=
VALUATION: $_ _ ) 6 g STOTAL AREA: ZZ
Lilbor
HEATED AREA: Z55
(Cost of and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
3
SEWER TAP: INTERIOR WALL TYPE:
SIZE �t
WATER TAP: 3c EXTERIOR WALL TYPE:
13&16104
SIZE
OTHER TAP: FOUNDATION TYPE:
.5L-A wr! Ct m4 AAf
SIZE
TEMP POLE ROOF TYPE:
: 6 L6-
GARAGE TYPE: SINGLE a DOUBLE TRIPLE
a
ATTACHED �rDETACHED a CARPORT
a
SIGNATURE OF APPLICANT:
Official Use OnlyCN �0 �
163
oil ents:
YES r NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls 2,6t—
Insulation R value of exterior walls Z 13
Insulation R value of ceiling 1 (flat areas) �, • 3d
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGCD
Glazing U-Factor `f
R value of ductwork 9-4
A/C SEER rating /L
1 Z 5ee,/
(19i13/2003 THL 8;53 FAX 979 693 255d McClure Engineering inc. 4-).4 F.roehlin.g> Edwar 2006/46
I `
�'
:lost 47, BJmk 2
I �Gas�r�a�7+ote Sribabi�xs�ov�
5whr. 30'
Sir
Lot I
I t
I
n
I
(
Prropowd
I
RdWA2Wnca
S 6$'•f?"Q9' W — A V'✓
/Iwk of Curb
Rownstone Loop
W' R.d#.. — 24' rr&vf
Vol 4", PA Sl
W-Wbaz aw
Atafl'E'MWINANWM,INC•fAVJWbOdyr * ' MY- COAeSAWOV,.rRXwMAV-11N)6MUM
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: Untitledrek
TITLE: 2019 RAVENSTONE LOOP
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 09/18/03
DATE OF PLANS: SEPTEMBER 18, 2003
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 798
Your Home UA = 697
12.7% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.38
Gross
Glazing
Area or
Cavity
Cont. or Door
Perimeter R-Value
R-Value U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
2554
30.0
0.0
89
Wall 1: Wood Frame, 16" o.c.
433
13.0
0.0
26
Window 1: Metal Frame:Double Pane with Low-E
83
0.640
53
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Front
Projection factor: 0.19
Door 1: Solid
38
0.400
15
Wall 2: Wood Frame, 16" o.c.
649
13.0
0.0
48
Window 2:
Metal Frame with Thermal Break:Double Pane with Low-E
43
0.640
28
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Door 3: Solid
18
0.400
7
Wall 3: Wood Frame, 16" o.c.
419
13.0
0.0
27
Window 3: Metal Frame:Double Pane with Low-E
70
0.640
45
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 0.27
Door 2: Glass
18 0.580 10
SHGC: 0.78
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 1.23
Wall 4: Wood Frame, 16" o.c.
649 13.0 0.0 47
Window 4: Metal Frame:Double Pane with Low-E
73 0.640 47
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Right Side
Projection factor: 0.23
Floor 1: Slab-On-Grade:Unheated
245 0.0 255
Insulation depth: 0.0'
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RES checkVersion 3.5 Release lb (formerly MECchec,� and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer—'a, 4" Date