Loading...
HomeMy WebLinkAboutRES2003-02983 3721 SPRINGFIELD DR BUILDING PERMITPREPARED 1/28/04, 7:31:55 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/28/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3721 SPRINGFIELD DR SUBDIV: WESTFIELD ADDITION PH 2 CONTRACTOR : MAIN STREET HOMES PHONE : (979) OWNER : MAIN STREET HOMES CS LTD PHONE : PARCEL : 650700-0201-0110 APPL NUMBER: 03-00002983 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ P$RMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 11/03/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 11/03/03 DP 11/03/2003 08:04 AM MALFORD 11/03/2003 03:46 PM MALFORD NEEDS SLAB SURVEY OR STRINGS ON PROPERTY SETBACKS , NEEDS TP FIT GLASTIC ON PADS , STIR UPS CAN NOT EARTH MAKE CONTACT WITH � B100 02 11/04/03 CW BLDG, FOUNDATION -SLAB TIME: 17:00 11/04/03 AP 11/03/2003 04:17 PM MALFORD V B115 01 11/24/03 OC BLDG, FRAMING TIME: 17:00 11/26/03 AP 11/24/2003 10:03 AM MALFORD B125 01 1/28/04 BI BLDG, FINAL TIME: 17:00 COMMENTS AND NOTES Y Mandi Alford- Insulation request ins ec result 3721 Springfeld, #03-2983_._y.__ Ps I From: 'Brian Henry To: Carrillo, Gina; Stanley, Susan Date: 1 12/8/2003 10:39:33 AM _ Subject: Insuiation request inspection result, 3721 Springfield�-#03-2983 Print for File Inspected insulation, 3721 Springfield, #03-2983, Mainstreet Homes, 12-8-03 Inspection result: Inspected for Code Only CC: Alford, Mandl BUIL?'qNG PERMITI r COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002983 Date 10/01/03 Property Address . . . . . . 3721 SPRINGFIELD DR Property ID 650700-1201-0110 R # . . . . . . . R114107 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD ADDITION PH 2A Property Use . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 81840 Owner Contractor ------------------------ MAIN STREET HOMES ------------------------ CS LTD MAIN STREET HOMES % MSH-CS INC RICK JENKINS PETER L DAVIS 7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150 AUSTIN TX 787464130 AUSTIN TX 78746 (979) -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1240.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 388.00 Plan Check Fee .00 Issue Date . . . . 10/01/03 Valuation . . . . 81840 Expiration Date . . 3/30/04 Qty Unit Charge Per Extension BASE FEE 260.00 32.00 4.0000 THOU BLDG, VAL 50001-100000 128.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER (S ) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT -------------------------------------------------- BUILDING DEPT REPRESENTATIVE: - APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00002983 Page 2 Date 10/01/03 Special Notes and Comments PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited / Due ------------------------------------------------------ ------------------ BUILDING DEPT REPRESFDTZATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Permit Fee Total 388.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1138.00 03-00002983 388.00 .00 .00 .00 750.00 .00 1138.00 .00 Page 3 Date 10/01/03 .00 .00 .00 .00 ----------------------------------------------------- - ------------------- BUILDING DEPT REPRESENTAT . APPLICANT: �� City of College Station WORK QUEST PAGE 1 REQ/JOB: WF0464804 / U01 PROJECT: REQUESTPRINT DATE: 10�01f03 CREW: PRINT TIME: 14:35:55 SCHEDULE DATES LOCATION: 3721 SPRINGFIELD DR START: 77845 COMPLETION: 10// 0103 GEN. LOC: COLLEGE STATION LOC ID: 196368 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN USER TD: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3 4"WTR, 4"SWR ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4"WTR, 411SWR Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE APPLICATION FOR BUILDING PERM[ CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: � � S Ad,.II-� F1 E:L.•N LOT I I BLOCK J SUBDIVISION Westf ield BUSINESS/OWNER NAME: � Fm o fiee use 0* DATE: - / jJ,,c'1 03 APPLICATION # _ !aq TEMP POLE # PHONE: CONTRACTOR/HOMEOWNER: Main Street Homes PHONE: (512) 327-8620 CONTRACTOR ADDRESS: 7447 Bee Cave Rd., Austin, TX 78746 ELECTRICIAN: Hillco Electric HVAC: Barkers HVAC PLUMBER: CP Plumbing GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Construct Single Family Residence `STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: m� TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ . VALUATION: $ 5'l?q_Q TOTAL AREA: I 19TA HEATED AREA: q6 (Cost of Labor and Materlals) ® PUBLIC SEWER NUMBER OF BEDROOMS: 3 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: ® SEWER TAP: 4" INTERIOR WALL TYPE: Wood / Sheetrock SIZE yQd �� Xa WATER TAP: 3/4" EXTERIOR WALL TYPE: Wood/ Masonry SIZE OTHER TAP: TEMP POLE GARAGE TYPE: SIZE SINGLE a ATTACHED SIGNATURE OF APPLICANT: FOUNDATION TYPE: Post Tension on Grade ROOF TYPE: DOUBLE DETACHED a Asphalt Shingles TRIPLE ED CARPORT a Official Use Only ants: �r NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating /5- 3a