RES2003-02958 1732 HEATH DR BUILDING PERMIT
PREPARED 4/16/04, 7:59:32 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/16/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1732 HEATH DR SUBDIV: SPRING CREEK TOWNHOMES PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE : (979) 690-1222 OWNER CROWLEY, TIMOTHY J PHONE : PARCEL 582882-0104-0230 APPL NUMBER: 03-00002958 RESIDENTIAL, 1 UNIT ATTACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/23/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 10/24/03 AP 10/23/2003 08:14 AM GCARRILLO B115 01 1/28/04 OC BLDG, FRAMING TIME: 17:00 1/28/04 CA 01/28/2004 08:49 AM GCARRILLO cancelled per oscar/not ready B115 02 2/04/04 OC BLDG, FRAMING TIME: 17:00 2/04/04 AP 02/04/2004 09:40 AM MALFORD B130 01 2/06/04 TB BLDG, INSULATION TIME: 17:00 2/06/04 AP 02/05/2004 03:36 PM MALFORD B125 07. 4/16/04 B_I BLDG, FINAL TIME: 17:00 04/15/2004 04:45 PM SSTANLEY ----------------------------------- COMMENTS AND NOTES-------------------------------------- -- m-- I w Q m� LLJ I ------------ m �I En I � c) ao� u0 PROPOSED RFSInFNCF I •a d I TWO CAR GARAGE - -- — - --- -- - --- -- --- -- I 148, 1�� I 14a� 71,E - I C 4' I —20'REARB.L.' -------'---- 20'P_U_E_— '------y Y I I I , _ I PROPOSED / PROPOSED PROPOSED RFSInFNCE RESIDENCE RESIDENCE TWO CAR ` GARAGE TWO CAR GARAGE �a a a. a °. 146'-7" i ° ° Id a 4-° ° e 1736d a .1734� 17�2 Al SPRING CREEK TOWNHOMES HEATH DRIVE LOTS - 20,21,22,23,24,25 BLOCK - 4 PHASE-1 1 SITE PLAN BC F 115,1--0' ------------ I iC� PROPOSED PROPOSED RESIDENCE I RESIDENCE I � ' Z TWO CAR ' TWO CAR I j GARAG E GARAGE I - I --------=- ° 20' FRONT B.L. a a- °. 1730 1728 ` a AREA SUMMARY TOTAL A/C 0 SF COV. PORCH AREA 0 SF GARAGE 0 SF TOTAL FRAMED 0 SF PERIMETER 546'-7" TOTAL SLAB 7667 SF BUILDING PERMIT �QITY OF, OLLEGE STATIOM 1 �AVE- COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002958 Date 9/30/03 Property Address . . . . . . 1732 HEATH DR Property ID 444444-0104-0230 R # . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT ATTACHED NEW Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 105468 Owner Contractor ------------------------ CROWLEY, TIMOTHY J ------------------------ STYLECRAFT BUILDERS 1301 MCKINNEY ST STE 3500 RANDY FRENCH HOUSTON TX 770103034 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1598.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 2.00 SEWER TYPE PUBLIC SERIAL ZONES 294.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MR Permit Fee . . . . 478.00 Plan Check Fee .00 Issue Date . . . . 9/30/03 Valuation . . . . 105468 Expiration Date . . 3/29/04 Qty Unit Charge Per Extension BASE FEE 460.00 6.00 3.0000 THOU BLDG, VAL 100001-500000 18.00 ---------------------------------------------------------------------------- Special Notes and Comments refer to permit number 03-2954 for comments and plans ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 ----------------------------------- ----- -- ---------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00002958 Date 9/30/03 Fee summary ----------------- Charged ---------- Paid ---------- Credited ---------- Due ---------- Permit Fee Total 478.00 478.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1228.00 1228.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT:� �r TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002960 Date 9/30/03 Property Address . . . . . . 1732 HEATH DR Property ID . . 444444-0104-0230 R # . . . . . . . . . . . . . R***** Tenant nbr, name . . . . . . TEMP POLE Application description . . . TEMP POLE Subdivision Name . . . . . . Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ CROWLEY, TIMOTHY J ------------------------ STYLECRAFT BUILDERS 1301 MCKINNEY ST STE 3500 RANDY FRENCH HOUSTON TX 770103034 4090 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MR Permit Fee . . . . 20.00 Issue Date . . . . 9/30/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged --------------------------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 --------------------------- ---- - -- ------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: /� Tom,. CITY OF COLLEGE STATION WORK QUEST REQ/JOB: WF0464368 / U01 PROJECT: CREW: LOCATION: 1732 HEATH DR 77845 PAGE REQUEST DATE: PRINT DATE: PRINT TIME: SCHEDULE START: COMPLETION: 1 9�30�03 11:14:17 DATES 93003 9Z30/03 GEN. LOC: COLLEGE STATION LOC ID: 198274 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER D: MRODGERS AUTH: MRODGERS WORK TYPE: ROUTINE 3j4"WTR, 411SWR ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4"WTR, 4"SWR Category code . Task code: Facility ID Assigned Department: CS -CUSTOMER SERVICES SET UP NEW UTILITY ACCT OT-CUSTOMER SERVICE CSCS SET APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COL'LEGE-STATION.TX.US ADDRESS/LOCATION: 1-I 3 For Ofte Use Only DATE: Ct -9 ,3 _o3 APPLICATION # S TEMP POLE # LOT � 3 BLOCK 4 SUBDIVISION S,o ra !25 Ctc e K TUwa G,% P S PHASE BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framina STRUCTURE USE: Sinale Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: 1es TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ WA VALUATION: $ 10 s, 4 6 8 TOTAL AREA: 104� - HEATED AREA: S 9 9 (Cost of Labor and Materials) FX PUBLIC SEWER ❑ SEPTIC[TREATMENT SYSTEM OD 13QX SEWER TAP: 4e 010 too QX WATER TAP: ❑ OTHER TAP: L§� (5 QX TEMP POLE GARAGE TYPE: NZE 8Y4n SIZE SIZE SINGLE E] ATTACHED aX SIGNATURE OF APPLICANT: Plans Examiner NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE: DOUBLE DETACHED Official Use Only Sheet Rock Siding and/or Masonry Slab on Grade Composition TRIPLE Q CARPORT El Zoning Official Comments: YES or NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: S:\ACAD\REScheck\A-1_Spring Creek II.cck TITLE: Plan # Al Spring Creek R CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 09/19/03 DATE OF PLANS: 09-19-2003 PROJECT INFORMATION: Philips Spring Hill Drive College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: Passes Maximum UA = 1113 Your Home UA = 848 23.8% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 667 30.0 0.0 23 Ceiling 2: Cathedral Ceiling (no attic) 110 19.0 0.0 6 Wall 1: Wood Frame, 16" o.c. 25§5 13.0 0.0 190 Window 1: Metal Frame, Double Pane with Low-E A0 0.670 121 SHGC: 0.40 Door 1: Solid 3 0.500 19 Door 2: Glass 5 0.440 26 SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated 4414 0.0 463 Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, r v and other calculations submitted with the permit application. The roposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly ME heck and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date 7-lR-� 3 REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 09/19/03 TITLE: Plan # Al Spring Creek H Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor. 0.500 Comments: [ ] 2. Door 2: Glass, U-factor: 0.440 Comments: Floors: [ ] 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher Make and Model Number [ ] 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) 14 Area Calculator: Window Name =0 IMIMME=M Comments/ I Description Mee , Window Area Total: 179.99 09/19/0311:07:24 1 /1 Area Calculator: Description door m� ��■�■����� Door Area Total: 95.56 09/19/0311:07:25 1 /1 Area Calculator: v■�■���ME In �■�■�� ®■�■�� m■�■��� ®■�■�� m �■�■��� ®■�■�� m �■�■�� ® �■�■�� m �■�■�� Ceiling Area Total: 777.00 09/19/0311:07:25 1 /1 Area Calculator: Assembly Type �� ©• �� Comments/Description © ... I MEMO..■�■ „ . m �■�■�� m �■�■�� m �■�■�� ® �■�■�� m �■�■�� Exterior Wall Area Total: 2594.84 09/19/0311:07:26 1 /1 Area Calculator: Assembly Type■ Comments/Description All -Wood Joist/Truss, Over Unconditioned Space m■�■�■ ®■�■�■■ m■�■■�■ m■�■�■ Floor Area Total: 444.00 09/19/0311:07:27 1/1