Loading...
HomeMy WebLinkAboutRES2003-02911 3917 SPRINGMIST DR BUILDING PERMITPREPARED 5/28/04, 12:00:46 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 5/28/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3917 SPRINGMIST DR SUBDIV: WESTFIELD VILLAGE PH 1 CONTRACTOR : STYLECRAFT BUILDERS PHONE : (979) 690-1222 OWNER : BCS DEVELOPMENT CO PHONE : PARCEL : 650730-0101-0370 APPL NUMBER: 03-00002911 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 9/26/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 9/26/03 AP 09/26/2003 08:41 AM MALFORD 09/26/2003 04:11 PM MALFORD SETBACK STRINGS PULLED , SLAB GROUND BACK B115 01 10/23/03 CH BLDG, FRAMING TIME: 17:00 10/23/03 AP 10/23/2003 09:08 AM MALFORD 11.30 01 10/24/03 DS BLDG, INSULATION TIME: 17:00 10/24/03 AP 10/24/2003 11:26 AM SSTANLEY B125 01 4/07/04 DP BLDG, FINAL TIME: 17:00 4/08/04 DA 04/07/2004 11:37 AM SSTANLEY House Locked J125 02 5/28/04 BI BLDG, FINAL TIME: 17:00 05/28/2004 11:16 AM GCARRILLO i CALL BEFORE YOU GO OUT 412-5002 TIM -J--------------------------------- CONTINUED ONTO C NEXT PAGE ----------------------------------- 0j�r CITY OF COLLEGE STATION WORK REQUEST PAGE 1 REQ/JOB: WF0462598 / 001 PROJECT: REQUEST DATE: 9/23/03 PRINT DATE: 9/23/03 CREW: PRINT TIME: 7.36:18 SCHSTART LOCATION: 3917 SPRINGMIST DR :DATE 9/ 3/03 77845 COMPLETION: 9/2 03 GEN. LOC: COLLEGE STATION LOC ID: 195720 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE Y � 10/13/2003 MON 11:13 FAa 979 690 0348 STYLECRAFT BUILDERS INC IM002/002 V /03 To Whom This May Concern. - I'm am writing this letter on behalf of Stylecraft Builders, Inc. in order to inform you of a change on the HVAC permit of our job at 3917 Springmist, We originally listed Control Temp to do this project, and it has since been changed to Nacho Mosqueda. Please let me know if there is anything further needed from me, and I am sorry for any inconvenience this may have caused, Thank you, Eric Wivagg Architectural Designer Stylecraft Builders, Inc. 10/13/2003 MON 11:13 FAa 979 690 0348 STYLECRAFT BUILDERS INC 10 0 001/002 A_S' FAX COVER SHEET DATE: k / 13 / 63 COMMENTS: PAGES: 2- (Including cover) FROM: Eric Wivagg 4090 Highway 6 South College Station, Texas 77845 Phone: (979) 690-1222 ext. 20 Fax: (979) 690-0348 BUILDING PERMIT COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------- -------------------------------- Application Number . . Property Address . . . Property ID R# . . . . . . . . . . Application description Subdivision Name . . . Property Use . . . . . Property Zoning . . . . Application valuation . . . . 03-00002911 Date 9/18/03 . 3917 SPRINGMIST DR 650730-0101-0370 . . . R113318 . . . RESIDENTIAL, 1 UNIT DETACHED NEW . . . WESTFIELD VILLAGE PH 1 . . . RESIDENTIAL . . . UNKNOWN . . . 80190 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1215.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 384.00 Plan Check Fee .00 Issue Date . . . . 9/18/03 Valuation . . . . 80190 Expiration Date . . 3/17/04 Qty Unit Charge Per Extension BASE FEE 260.00 31.00 4.0000 THOU BLDG, VAL 50001-100000 124.00 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER (S ) ------------------------------- --- ------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT:�'��i•+� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 03-00002911 Page 2 Date 9/18/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES Other Fees . . . . . . . . . Fee summary Charged SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Paid Credited Due ---------------------------- -- �- ------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: � BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . 03-00002911 Date 9/18/03 Permit Fee Total 384.00 384.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1134.00 1134.00 .00 .00 ----------------------- --- -------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: �g��" TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002912 Date 9/18/03 Property Address . . . . . . 3917 SPRINGMIST DR Property ID . . . . . . . . . 650730-0101-0370 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 9/18/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged --------------------------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ----------------------- - - -------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT:/—'""' CITY OF COLLEGE STATION WORK iQUEST PAGE 1 REQ/JOB: WF0461694 / 001 PROJECT: REQUEST DATE: PRINT 18 9///03 CREW: PRINT TIME: 8:55:06 SCHSTART.DATES LOCATION: 3917 SPRINGMIST DR 9/18/03 77845 COMPLETION: 9/18/03 GEN. LOC: COLLEGE STATION LOC ID: 195720 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER D: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 32%4" WATER 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: LOT 3� BLOCK 1 SUBDIVISION f Far ofte Use only DATE: R- 15- 9 3 APPLICATION # /j ✓ d 3 °Z C1 1 1 TEMP POLE # '�C' -' 1 PHASE I BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTORIHOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Hlahway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbina HVAC: Control Temg GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framina STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ WA VALUATION: $ FC yt� Iq1... 001 TOTAL AREA: 0 HEATED AREA: a %5 (Cost of Labor and Materials) ❑X PUBLIC SEWER SEPTIC/TREATMENT SYSTEM ❑X SEWER TAP: _25L� ❑X WATER TAP: OTHER TAP: O� X TEMP POLE GARAGE TYPE: SIZE 3/4n SIZE SIZE SINGLE El ATTACHED SIGNATURE OF APPLICANT: K,t = Plans Examiner NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE F__j TRIPLE DETACHED ED CARPORT Official Use Only Zoning Official Siding and/or Masonry Slab on Grade Composition ED &7ents: Eor NO Energy Code Compliance Information % Glazing of exterior walls 1 0 % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 Area Calculator: Window Name Comments/ Description Window Area Total: 157.67 09/15/03 08:38:05 1/1 Area Calculator: 10=10� Assembly Type MIMIwMM=M Description Opaque door solid Door Area Total: 55.56 09/15/03 08:38:06 1/1 Area Calculator: © .. ,,, ■�■ ,,„© In m ��■�■�� dim �■�■�� ® © �■�■�� m■�■�� Ceiling Area Total: 1320.00 09/15/03 08:38:07 1/1 Area Calculator: Assembly Type Comments/Description Exterior Wall Area Total: 1168.00 09/15/03 08:38:08 1/1 Area Calculator: Assembly Comments/Description m �■�■�� ®■�■�� m■�■�� ®■�■�� m �■�■�� Floor Area Total: 0.00 09/15/03 08:38:09 1/1 REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lc Data filename: S:\ACAD\REScheck\1226-1215-1053 Windmeadows.cck TITLE: PLAN #1226-1215 Porch CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 09/12/03 DATE OF PLANS: 9/15/03 PROJECT INFORMATION: spec 3917 Springmist College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 1'OMPLtANCE:-Passes Maximum UA = 547 Your Home UA = 461 15.7% Better Than Code (UA)_ Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 2: Wood Frame, 16" o.c. Window 4: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 3: Solid Door 5: Glass SHGC: 0.40 Floor 1: Unheated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, I 1 SEER Furnace 1: Forced Hot Air, 80 AFUE U 3 --a9/r Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 864 30.0 0.0 30 380 19.0 0.0 20 1376 13.0 0.0 96 150 0.670 101 38 0.500 19 18 0.440 8 179 0.0 187 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lc (formerly MECchec4 and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date ' a REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release lc DATE: 09/12/03 TITLE: PLAN #1226-1215 Porch Bldg. Dept. Use [ ] [l [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Wails: 1. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 4: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] I 1. Door 3: Solid, U-factor: 0.500 Comments: [ ] I 2. Door 5: Glass, U-factor: 0.440 Comments: I Floors: [ j I 1. Floor 1: Unheated, R-0 (uninsulated) Comments: I Heating and Cooling Equipment: [ ] I 1. Air Conditioner 1: Electric Central Air, 11 SEER or higher Make and Model Number [ ] I 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number I Solar Heat Gain Coefficient: [ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ) I Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)