Loading...
HomeMy WebLinkAboutRES2003-02909 3923 SPRINGMIST DR BUILDING PERMITPREPARED 1/08/04, 11:59:42 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/08/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 3923 SPRINGMIST DR SUBDIV: WESTFIELD VILLAGE PH 1 CONTRACTOR : STYLECRAFT BUILDERS PHONE : (979) 690-1222 OWNER : BCS DEVELOPMENT CO PHONE : PARCEL : 650730-0101-0400 APPL NUMBER: 03-00002909 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/02/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 10/02/03 AP 10/02/2003 10:00 AM GCARRILLO 10/03/2003 08:52 AM MALFORD slab ground back left side , strings on set backs ok B115 01 10/31/03 DS BLDG, FRAMING TIME: 17:00 11/03/03 AP 10/31/2003 08:31 AM GCARRILLO B130 01 11/04/03 CW BLDG, INSULATION TIME: 17:00 11/05/03 AP 11/04/2003 08:12 AM MALFORD B125'O1 1/08/04 BI BLDG, FINAL TIME: 17:00 O1/08/2004 08:50 AM GCARRILLO --------------'------------------------ COMMENTS AND NOTES ---------- --------------------------- y CITY OF COLLEGE STATION r WORK REQUEST PAGE 1 REQ/JOB: WF0462081 / 001 PROJECT: REQUEST DATE: F 9/19,PRINT /03 CREW: PRINT TIME: 11:03:20 SCHSTART.DATES LOCATION: 3923 SPRINGMIST DR 9/19/03 77845 COMPLETION: 9/19/03 GEN. LOC: COLLEGE STATION LOO ID: 195726 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS . Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- BUILDING PERMIT- Itbl °ISEXAS`` COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002909 Date 9/18/03 Property Address . . . . . . 3923 SPRINGMIST DR Property ID 650730-0101-0400 R # R113321 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 86592 Owner Contractor ------------------------ ------------------------ BCS DEVELOPMENT CO STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1312.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 408.00 Plan Check Fee .00 Issue Date . . . . 9/18/03, Valuation . . . . 86592 04 Expiration Date . . 3 17 P / / Qty Unit Charge Per Extension BASE FEE 260.00 37.00 4.0000 THOU BLDG, VAL 50001-100000 148.00 -------------------------- Special Notes and Com ments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER (S ) ---------------------------- - -- ----------------------- - BUILDING DEPT REPRESENTATIVE: _ w APPLICANT: Ir'� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 03-00002909 Page 2 Date 9/18/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER T 4" CITY INSTALL 350.00 BUILDING DEPT REPRESEENNTATIVE: APPLICANT: % �/r BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00002909 Date 9/18/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 408.00 408.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1158.00 1158.00 .00 .00 ----- -------------------��--�\- ------------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: = %vP-0 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002910 Date 9/18/03 Property Address . . . . . . 3923 SPRINGMIST DR Property ID 650730-0101-0400 R # . . . . . . R113321 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 9/18/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged --------------------------- Paid Credited ------------------------------ Due Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ---------------------------------------- ------------- ----------- BUILDING DEPT REPRESENTATIVE: APPLICANT: ��•j CITY OF COLLEGE STATION WORF ;QUEST PAGE 1 REQ/JOB: WF0461691 / 001 PROJECT: REQUEST DATE: 9/18/03 PRINT DATE: 9/18/03 CREW: PRINT TIME: 8:53:47 DULLOCATION: SCHSTARRT.DAT9/18/03 3923 SPRINGMIST DR 77845 COMPLETION: 9718703 GEN. LOC: COLLEGE STATION LOC ID: 195726 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER D: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3 4" WATER 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: I-)F n i tuy 1 11 S For�OMe Use Omy or` DATE: - / $ - o �3 APPLICATION # O 6021 TEMP POLE # O �"' • I b LOT 4" BLOCK I SUBDMSION 9 �►P It I t �V`�I PHASE I BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Hi-ghway 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbina HVAC: Control Temp GOOD CENTS (Residential only): No If] WF•*3e7 &Yto7 fl ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Sinale Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ WA VALUATION: $ &lp, <�-)01a • co TOTAL AREA: HEATED AREA: (Cost of Labor and Materials) 1-70 I FX PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM ❑X SEWER TAP: M WATER TAP: OTHER TAP: ❑X TEMP POLE 4° SIZE 3/4■ SIZE SIZE GARAGE TYPE: SINGLE ATTACHED EX SIGNATURE OF APPLICANT: a'j Plans Examiner NUMBER OF BATHROOMS: INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition DOUBLE F—� TRIPLE a DETACHED E-1 CARPORT ❑ Official Use Only Zoning Official m ents: Y rN0 Energy Code Compliance Information % Glazing of exterior walls 12-)% Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 K .- RE5check Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lc Data filename: S:WCAD\REScheck\1320 Select.cck TITLE: PLAN # 1320 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 09/12/03 DATE OF PLANS: 9/12/03 PROJECT INFORMATION: West Field Village 3923 Springmist College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 L, CO]VIPLIANCE: Passes Maximum UA = 468 Your Home UA = 416 11.1 % Better -Than Code-(UA) - Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 2: Wood Frame, 16" o.c. Window 4: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 3: Solid Door 4: Solid Door 5: Solid Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 11 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1030 30.0 0.0 36 290 19.0 0.0 15 1168 13.0 0.0 78 158 0.670 106 20 0.500 10 18 0.580 10 18 0.500 9 146 0.0 152 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release lc (formerly M ECchec4 and to comply with the mandatory requirements listed in the RESchecklnspection Checklist. Builder/Designer Date REScheck Inspection Checklist 200O IECC REScheckSoftware Version 3.5 Release lc DATE: 09/12/03 TITLE: PLAN #1320 Bldg. Dept. Use I Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 4: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 3: Solid, U-factor: 0.500 Comments: 2. Door 4: Solid, U-factor: 0.580 Comments: 3. Door 5: Solid, U-factor: 0.500 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 11 SEER or higher Make and Model Number 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's mstallation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ J The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] ( Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: = Window Name Assembly Type _, ==jMj�K,3M== EmsEll Comments/ Description Window Area Total: 157.67 09/15/03 08:35:24 1/1 Area Calculator: Descdptlon Opaque door solid Door Area Total: 55.56 09/15/03 08:35:25 1/1 Area Calculator: m■�■�� ®■�■�� m �■�■�� Ceiling Area Total: 1320.00 09/15/03 08:35:26 1/1 Area Calculator: Exterior Wall Area Total: 1168.00 09/15/03 08:35:27 1/1 Area Calculator: M Assembly Type -AM, MDEEMCWW "MMM Comments/Description m ®■�■�� m■�■�� ®■�■�� m �■�■�� Floor Area Total: 0.00 09/15/03 08:35:28 1/1