HomeMy WebLinkAboutRES2003-02894 4205 DROGO CT BUILDING PERMITPREPARED 3/26/04, 12:08:00 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/26/04
------------------------------------------------------------------------------------------------
ADDRESS . .
CONTRACTOR :
OWNER
PARCEL .
APPL NUMBER:
4205 DROGO CT
EASTERLING HOMES
GREENS PRAIRIE INVESTORS LTD
184200-0102-0620
SUBDIV: CASTLEGATE SEC 10,11,12,13
PHONE : (979) 846-4909
PHONE :
03-00002894 RESIDENTIAL, 1 UNIT DETACHED NEW
-------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
10/16/03
TB
BLDG, FOUNDATION -SLAB TIME: 17:00
10/17/03
AP
10/16/2003 07:12 AM SSTANLEY
late afternoon.
STRINGS ON SETBACKS OK. FRONT & BACK RT. ON SLAB GROUND
BACK RT. CORNER.
B115 01
12/08/03
TB
BLDG, FRAMING TIME: 17:00
12/08/03
AP
12/08/2003 01:46 PM GCARRILLO
B125 01
3/17/04
BI
BLDG, FINAL TIME: 17:00
3/17/04
CA
03/17/2004 10:17 AM MALFORD
house will be open
03/17/2004 10:19 AM MALFORD
B125 02
3/23/04
DP
BLDG, FINAL TIME: 17:00
3/23/04
DP
03/22/2004 01:56 PM GCARRILLO
Combustion Air Needed For Utility Room
laundry room with gas does not meet combustion air require.
lights in master bath are not working.
B125 03
/26/04
BI
BLDG, FINAL TIME: 17:00
3
GAS LINE IN UTILITY ROOM HAS BEEN REMOVED. LIGHT IN MASTER
BATH - SWITCHES ON 45 WALL. MARTY EASTERLING 412-1755
i
----------------------------------
COMMENTS AND NOTES --------------------------------------
City of Colleqe Station
WORK REQUEST PAGE 1
REQ/JOB:
WF0467305 / 001
PROJECT: REQUEST DATE:
10/15/03
PRINT DATE:
10715703
CREW:
PRINT TIME:
b:15:32
SCHEDULE
LOCATION:
4205 DROGO CT
START:DATES
10/15/03
77845 COMPLETION:
107-15703
GEN. LOC:
COLLEGE STATION
LOC ID: 197962
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR:
EASTERLING HOMES
ORIGIN: CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH:
SSTANLEY WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE ,PASSED
Categorycode .
Task coe:
Facility ID .
Assigned Department:
CS -CUSTOMER SERVICES
SET UP NEW UTILITY ACCT
OT-CUSTOMER SERVICE
SES T
Mandi Alford -Insulation request inspection resuit�4205 Droo #03-2894 u__ Page,1
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 12/1112003 3:36:42 PM
Subject: Insulation request inspection result, 4205 Drogo, #03-2894
Print for File
Inspected insulation Drogo, #03-2894, Easterling Homes, 12-11-03
Inspection result: Inspected OK for Good Cents
CC: Alford, Mandi
BUILDING PERMIT
CITY OF C5hLF4E STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00002894 Date 3/29/04
Property Address . .
. . . . 4205 DROGO CT
Property ID
184200-0102-0620
R # . . . . . .
R115306
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CASTLEGATE SEC 10,11,12,13
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . PLANNED DEVL HOUSING
Application valuation
. . . . 105402
Owner
Contractor
------------------------ ------------------------
GREENS PRAIRIE INVESTORS LTD EASTERLING HOMES
4490 CASTLEGATE DR
MARTY EASTERLING
COLLEGE STATION
TX '78453388 P 0 BOX 6436
BRYAN TX 77805
(979) 846-4909
--------------------------
Structure Information -------------------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1597.00
INTERIOR WALL TYPE SR
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
MA
Permit Fee . . . .
478.00 Plan Check Fee .00
Issue Date . . . .
10/14/03 Valuation . . . . 105402
Expiration Date . .
6/21/04
Qty Unit Charge
Per Extension
BASE FEE 460.00
6.00 3.0000
THOU BLDG, VAL 100001-500000 18.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
----------------------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 03-00002894
Page 2
Date 3/29/04
Special Notes and Comments
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
Other Fees SEWER TAP 4"
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
350.00
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Page 3
Application Number
. . . . .
03-00002894
Date 3/29/04
----------------------------------------------------------------------------
Other Fees . `. . .
. . . . .
WATER TAP 3/4"
400.00
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
----------
Due
----------
Permit Fee Total
478.00
478.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1228.00
1228.00
.00
.00
----------------------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: