HomeMy WebLinkAboutRES2003-02890PREPARED
1/27/04,
7:28:03
INSPECTION TICKET
PAGE 3
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 1/27/04
------------------------------------------------------------------------------------------------
ADDRESS
. : 3711 MEADOW VIEW DR SUBDIV: WESTFIELD ADDITION
PH 2
CONTRACTOR MAIN STREET HOMES
PHONE (979)
OWNER
MAIN STREET HOMES
CS LTD PHONE
PARCEL
650700-0211-0060
APPL NUMBER: 03-00002890 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
10/14/03
DS
BLDG, FOUNDATION -SLAB TIME: 17:00
10/14/03
DP
10/13/2003 12:43 PM GCARRILLO
NO SLAB SURVEY. BEAM STELL UNDER MUD AND WATER.
HAS DOWEL
RODS HOLDING UP STEEL ( CAN NOT BE IN CONTACT WITH EARTH
REMOVE WATER FROM BEAMS) FIX PLASTIC ON PADS.
B100 02
10/15/03
DS
BLDG, FOUNDATION -SLAB TIME: 17:00
10/15/03
DP
10/15/2003 09:41 AM SSTANLEY
only thing fixed from above list is form survey
B100 05
10/16/03
CH
BLDG, FOUNDATION -SLAB TIME: 17:00
10/17/03
DP
10/16/2003 02:08 PM SSTANLEY
REPAIR POLY. REMOVE WATER AND DIRT FROM BOTTOM
OF BEAMS.
B100 04
10/16/03
DS
BLDG, FOUNDATION -SLAB TIME: 17:00
10/16/03
CA
10/16/2003 10:38 AM MALFORD
afternoon please 10/16/03
still not fixed 10;00am
B100 03
10/16/03
DS
BLDG, FOUNDATION -SLAB TIME: 17:00
10/16/03
DP
10/16/2003 08:16 AM SSTANLEY
B100 06
10/17/03
DS
BLDG, FOUNDATION -SLAB TIME: 17:00
10/17/03
AP
10/17/2003 11:33 AM SSTANLEY REINSPECTION ='
B115 01
11/18/03
OC
BLDG, FRAMING TIME: 17:00
11/26/03
AP
11/18/2003 09:46 AM GCARRILLO
B125 01
1/23/04
DS
BLDG, FINAL TIME: 17:00 '.
`
1/23/04
DP
O1/23/2004 09:12 AM GCARRILLO
Need Address = r
B125 02 1/27/04 BI BLDG, FINAL TIME: 17:009
O1/26/2004 12:12 PM MALFORD
-------------------------------------- COMMENTS AND NOTES ------------------------------------- I X
-
Mandi,Alford -insulation request inspection result, 3711 Meadow View, #03-2890 _ , _ , _. .._.___ _ ..,, _ , Pale 1 i
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 12/2/2003 2:12:11 PM
Subject: Insulation request inspection result, 3711 Meadow View, #03-2890
Print for File
Inspected insulation, 3711 Meadow View, #03-2890, Mainstreet Homes 12-2-03
Inspection result: Inspected OK for Code Only
CC: Alford, Mandi
BUILDING PERMIT -
CITY_ OF+E� COLLEGE STATION
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 - FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00002890 Date 9/18/03
Property Address . .
. . . . 3711 MEADOW VIEW DR
Property ID
650700-2201-0060
R # . . . . . .
R*****
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . WESTFIELD ADDITION PH 2B
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 96294
Owner
Contractor
------------------------
MAIN STREET HOMES CS
------------------------
LTD MAIN STREET HOMES
% MSH-CS INC RICK JENKINS PETER L DAVIS
7447 BEE CAVES RD,STE
150 7447 BEE CAVE ROAD #150
AUSTIN
TX 787464130 AUSTIN TX 78746
(979)
--------------------------
Structure Information -------------------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID N
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1459.00
INTERIOR WALL TYPE S/R
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 248.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
SS
Permit Fee . . . .
448.00 Plan Check Fee .00
Issue Date . . . .
9/18/03 Valuation . . . . 96294
Expiration Date . .
3/17/04
Qty Unit Charge
Per Extension
BASE FEE 260.00
47.00 4.0000
THOU BLDG, VAL 50001-100000 188.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
-------------------------------------- - ---------------------------------
BUILDING DEPT JR23ygSENTATIVE.
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
ft 1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00002890
Page 2
Date 9/18/03
Special Notes and Comments
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
Other Fees . . . . . . . . .
Fee summary Charged
APPLICANT:
SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Paid Credited Due
.. ti i
�7ft 1 Li p 1111111110
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
----------------- ----------
Permit Fee Total 448.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1198.00
03-00002890
448.00 .00
.00 .00
750.00 .00
1198.00 .00
Page 3
Date 9/18/03
.00
.00
.00
.00
----------------------------------------------------------------------------
BUILDING DEPT ESENTATIVE: YYi�f
APPLICANT:
CITY OF COLLEGE STATION
WORK UEST
PAGE
1
REQ/JOB: WF0462015 / 001 PROJECT:
REQUEST DATE:
9/19/03
PRINT DATE:
9/19/03
CREW:
PRINT TIME:
8:24:21
SCHSTARRT.DATES
DULLOCATION:
3711 MEADOW VIEW DR
9/19/03
77845
COMPLETION:
9/19703
GEN. LOC: COLLEGE STATION LOC ID: 198302
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR: MAIN STREET HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE:
ROUTINE
3/4" WATER 4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
.
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764.3570 (979) 764-3496 FAX
W W W.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: A / I e' rAWC":. Q 1 Eck
LOT (4 BLOCK SUBDIVISION Westfield
BUSINESS/OWNER NAME:
F« MIN use%�onq
DATE' ' I 10 J
APPLICATION N
0-5-289
TEMP POLE 8
PHONE:
CONTRACTOR/HOMEOWNER: Main Street Homes PHONE: (512) 327-8620
CONTRACTOR ADDRESS: 7447 Bee Cave Rd., Austin, TX 78746
ELECTRICIAN: Hillco Electric
HVAC: Barkers HVAC
PLUMBER: CP Plumbing
GOOD CENTS (Residendal only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Construct Single Family Residence
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ ( : _ 7nn� TOTAL AREA: ;?CC4,v HEATED AREA:
(Cost of Labor and Materials)
M PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
® SEWER TAP:
WATER TAP:
4"
SIZE
3/4"
SIZE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS: a
INTERIOR WALL TYPE:
EXTERIOR WALLTYPE:
OTHER TAP: FOUNDATION TYPE:
SIZE
TEMP POLE ROOF TYPE:
GARAGE TYPE: SINGLE a DOUBLE ® TRIPLE
ATTACHED ® DET HED R
SIGNATURE OF APPLICANT:
Wood / Sheetrock
Wood/ Masonry
Post Tension on Grade
Asphalt Shingles
0
0
Off/cia/ Use Only
oke-G-) 1f3 _ Y;Sr NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls g
Insulation R value of exterior walls 1 S
Insulation R value of ceiling 1 (flat areas) <3c>
Insulation R value of ceiling 2 (vaulted areas/no attic) a_
Glazing SHGC -ace
Glazing U-Factor . & 4
R value of ductwork (o
A/C SEER rating /�2