HomeMy WebLinkAboutRES2003-02884PREPARED 1/16/04, 7:22:09 INSPECTION TICKET PAGE 2
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/16/04
------------------------------------------------------------------------------------------------
ADDRESS . .
CONTRACTOR :
OWNER
PARCEL .
APPL NUMBER:
302 CANDLE STONE CT
M/W CONSTRUCTION
WOODLAND HILLS DEVELOPMENT LTD
671200-0102-0360
SUBDIV: WOODLAND HILLS PH 1
PHONE : (979) 694-3600
PHONE :
03-00002884 RESIDENTIAL, 1 UNIT DETACHED NEW
-------------------------------
PERNIIT: BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
10/09/03
TB
BLDG, FOUNDATION -SLAB TIME: 17:00
10/09/03
CA
10/09/2003 11:37 AM GCARRILLO
10/09/2003 03:53 PM MALFORD
canceled due to the rain per mark golden and terry
B100 03
10/10/03
TB
BLDG, FOUNDATION -SLAB TIME: 17:00
10/10/03
AP
10/10/2003 09:46 AM MALFORD
STRINGS ON SETBACKS OK. SLAB GROUND BACK RT. SIDE.
B100 02
10/10/03
TB
BLDG, FOUNDATION -SLAB TIME: 17:00
10/09/03
CA
10/09/2003 03:54 PM MALFORD
B115 01
11/03/03
TB
BLDG, FRAMING TIME: 17:00
11/04/03
DP
11/03/2003 10:49 AM MALFORD
joist hangers @ attic access
"
loose anchor bolt nuts, missing front left corner
need to block windbracing joints @ front window
sheetrock top of fireplace
need to fill holes on repair straps @ electrical
fire block along rear wall where porch ceiling is different
height & front porch
B115 02 11/05/03 TB BLDG, FRAMING TIME: 17:00
11/05/03 AP 11/04/2003 04:23 PM MALFORD
B125 01 1/16/04 BLDG, FINAL TIME: 17:00
-((o ov 01/15/2004 04:44 PM SSTANLEY
-------------------------------------- COMMENTS AND NOTES--------------------------------------
CITY OF COLLEGE STATION
WORK REQUEST
REQ/JOB: WF0462406 / 001
CREW:
LOCATION: 302 CANDLE STONE CT
GEN. LOC: COLLEGE STATION
PAGE 1
PROJECT: REQUEST DATE: 9/22/03
PRINT DATE: 9722/03
PRINT TIME: 12:2S:59
SCHEDULE DATES
START: 922/03
77845 COMPLETION: 9722703
LOC ID: 190724
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: M/W CONSTRUCTION ORIGIN: CUSTOMER -WALK IN
USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
TEMP POLE PASSED
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 11/6/200311:11:52 AM
Subject: Insulation request inspection result, 302 Candle Stone, #03-2884
Print for File
Inspected insulation, 302 Candle Stone, #03-2884, MW Const., 11-6-03
Inspection result: Inspected OK for Good Cents
Notes:
Tape around the hall bathe window.
CC: Alford, Mandl
4t BUILDING PERMIT _
t7I-Ty OF
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00002884 Date 9/16/03
Property Address . . . . . . 302 CANDLE STONE CT
Property ID 671200-0102-0360
R # . . . . . . R108759
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WOODLAND HILLS PH 1
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 149820
Owner Contractor
------------------------ ------------------------
WOODLAND HILLS DEVELOPMENT LTD M/W CONSTRUCTION
1700 BARAK LN MARK GOLDEN
BRYAN TX 778023311 2912 CAIN ROAD
COLLEGE STATION TX 77845
(979) 694-3600
-------------------------- Structure Information -------------------------
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 2270.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 253.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . SS
Permit Fee . . . . 610.00 Plan Check Fee .00
Issue Date . . . . 9/16/03 Valuation . . . . 149820
Expiration Date . . 3/15/04
Qty Unit Charge Per Extension
BASE FEE 460.00
50.00 3.0000 THOU BLDG, VAL 100001-500000 150.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
-------------------------- --------- --------'------------
BUILDING DEPT REP)&SPKTATW-
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE'STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 03-00002884
Page 2
Date 9/16/03
Special Notes and Comments
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
BUILDING DEPT RE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 03-00002884 Date 9/16/03
----------------------------------------------------------------------------
Special Notes and Comments
EQUIPMENT AND A PRESSURE REDUCING VALVE
provide hearth in front of fireplace
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged
Permit Fee Total 610.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1360.00
------------------------------
BUILDING DEPT REPRAE24
APPLICANT:
Paid Credited Due
------------------------------
610.00 .00 .00
.00 .00 .00
750.00 .00 .00
1360.00 .00 .00
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00002885 Date 9/16/03
Property Address . . . . . . 302 CANDLE STONE CT
Property ID . . 671200-0102-0360
R # . . . . . . . . . . . . . R108759
Application description . . . TEMP POLE
Subdivision Name . . . . . . WOODLAND HILLS PH 1
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
WOODLAND HILLS DEVELOPMENT LTD M/W CONSTRUCTION
1700 BARAK LN MARK GOLDEN
BRYAN TX 778023311 2912 CAIN ROAD
COLLEGE STATION TX 77845
(979) 694-3600
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . SS
Permit Fee . . . . 20.00
Issue Date . . . . 9/16/03 Valuation . . . . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
Fee summary
-----------------
Permit Fee Total
Other Fee Total
Grand Total
-------------------
BUILDING DE
APPLICANT:
Charged Paid
--------------------
20.00 20.00
45.00' 45.00
65.00 65.00
Credited Due
--------------------
.00 .00
.00 .00
.00 .00
CITY OF COLLEGE STATION
WOR; EQUEST
PAGE
1
REQ/JOB:
WF0461103 / 001 PROJECT:
REQUEST DATE:
9/16/03
PRINT DATE:
9/16/03
CREW:
PRINT TIME:
10:46:05
SCHEDULE
DATES
LOCATION:
302 CANDLE STONE CT
START:
9/16/03
77845 COMPLETION:
9716/03
GEN. LOC:
COLLEGE STATION LOC
ID: 190724
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
M/W CONSTRUCTION
ORIGIN: CUSTOMER -WALK
IN
USER D:
SSTANLEY AUTH: SSTANLEY
WORK TYPE: ROUTINE
3I%41' WATER 4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1-3 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WWW.CI.COLLEGE-STAT2 7 IO�I.TTX// .US /f
ADDRESS/LOCATION: 3OCam• `O 54,nr, C:f.
LOT 3�� BLOCK �c SUBDIVISION On.i
BUSINESS/OWNER NAME: d*4 ,. Mors
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS: wfla Ctc:r►
For Ofte Use only R OL
DATE: _1-03
APPLICATION #
TEMP POLE #
PHONE:
M PHONE:
SEC/PH
ELECTRICIAN: Y (e s PLUMBER: t 4,_40 ,/
HVAC: tdt •v GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE: 5/;
HOMEOWNER ASSOCIATION/AR&ITECTUAL OR ffIESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
6 X) x-4 VALUATION: $ 1 4Q ,'R1O TOTAL AREA: 2 3 A HEATED AREA: -2.2 790
(Cost of Labor and Materi.1.%
C, _ [3/PUBLIC SEWER
n SEPTIC/TREATMENT SYSTEM
2/SEWER TAP:
q
u WATER TAP:
SIZE
3/
SIZE
OTHER TAP:
Rf TEMP POLE
SIZE
GARAGE TYPE: SINGLE
ATTACHED
SIGNATURE OF APPLICANT:
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE F__� TRIPLE
DETACHED a CARPORT
41
zy
ACcokoc
Official Use Only
ql&l^
ents:
YE or NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
T-17
T- 3o
G ec../ C
A/C SEER rating _J2 �e e.-