HomeMy WebLinkAboutRES2003-02870PREPARED 11/17/03, 12:11:36 INSPECTION TICKET PAGE 13
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/17/03
------------------------------------------------------------------------------------------------
ADDRESS . : 1014 BOUGAINVILLEA ST SUBDIV: SUN MEADOWS PH 2
CONTRACTOR K M CUSTOM HOMES PHONE : (979) 589-3739
OWNER KM CUSTOM HOMES INC PHONE :
PARCEL 589700-0210-0070
APPL NUMBER: 03-00002870 RESIDENTIAL, 1 UNIT DETACHED NEW
-------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 9/30/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00
9/30/03 AP 09/30/2003 12:42 PM SSTANLEY
10/01/2003 06:59 AM MALFORD
SETBACK STRINGS PULLED, SLAB GROUND BACK RIGHT
B115 01 10/15/03 CH BLDG, FRAMING TIME: 17:00
10/17/03 AP 10/15/2003 10:17 AM MALFORD
B125 01 11/17/03 BI BLDG, FINAL TIME: 17:00
P 11/17/2003 08:47 AM SSTANLEY
v Qj_>�
----------------------------------- CONTINUED ONTO NEXT PAGE ----------- - ------
r
ro �jf► 0r
City of College S" -ion
WORK QUEST PAGE 1
REQ/JOB: WF0465792 / 001 PROJECT: REQUEST DATE: 10/0 /03
PRINT DATE: 10/0 /03
CREW: PRINT TIME: 13:24.53
SCHEDULE DATES
LOCATION: 1014 BOUGAINVILLEA ST START:
/
77845 COMPLETION: 10/0703
GEN. LOC: COLLEGE STATION LOC ID: 194642
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: KM CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: GCARRILLO AUTH: GCARRILLO WORK TYPE: ROUTINE
TEMP POLE APPROVED
TEMP POLE APPROVED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
IµSusan Stanley -Insulation Inspection_ _.__ __ •_ __µ• _ _ Page 1;
From: Jane Sayers D
To: Alford, Mandi; Stanley, Susan
Date: 10/22/2003 4:49:05 PM
Subject: Insulation Inspection
I need to report an insulation inspection at 1014 Bougainvillea for KM Custom Homes completed on
10-17-03. There were no exceptions.
Jane
BUILDING PERMIT
t TY bF COLLEGE' STATION
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number
. . . . . 03-00002870 Date 9/24/03
Property Address
. . . . . . 1014 BOUGAINVILLEA ST
Property ID
. . 589700-0210-0070
R # . . . . . .
. . . . R111799
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
. . . . . . SUN MEADOWS PH 2
Property Use . .
. . . . . RESIDENTIAL
Property Zoning .
. . . . . . UNKNOWN
Application valuation
. . . . 116000
Owner
Contractor
------------------------
KM CUSTOM HOMES INC
------------------------
K M CUSTOM HOMES
10485 S FM 2038
KENNY MELESKY
BRYAN
TX 778089195 10485 FM 2038
BRYAN
TX 77808
(979) 589-3739
--------------------------
Structure Information -------------------------
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1633.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
SERIAL ZONES
245.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. SS
Permit Fee . . .
. 508.00 Plan Check Fee
.00
Issue Date . . .
. 9/24/03 Valuation . . .
. 116000
Expiration Date .
. 3/23/04
Qty Unit Charge
Per
Extension
BASE FEE
460.00
16.00 3.0000
THOU BLDG, VAL 100001-500000
48.00
----------------------------------------------------------------------------
Special Notes and
Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
-------------------------------------------- ---- -----
BUILDING DEPT RE S�VE:
---------------
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 03-00002870
Page 2
Date 9/24/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
Other Fees . . . . . . . . .
Fee summary Charged
SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Paid Credited Due
---------------------------------------------------------
--------------------------------
44-
------------------ ------
BUILDING DEPT REPRE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Page
3
Application Number
03-00002870
Date
9/24/03
Permit Fee Total
508.00
508.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1258.00
1258.00
.00
.00
-------------------- --- - -- .--------- -- - - -- --------------- - - --
BUILDING DEPT REP SEN-4�E /
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE Q J
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEGE-STATION.TX.US
For Oft@ Use only 1 DATE: _ 9 "O 3_
APPLICATION # /DA -p2� D
�/ TEMP POLE # 3 - 42t q I
ADDRESS/LOCATION: 1 Oly_duhc�v�.►'���h
LOT BLOCK I v SUBDIVISION SUPI RegJ`)Wj SEC/PH
BUSINESS/OWNER NAME: _T'fL PHONE:
CONTRACTOR/HOMEOWNER:PHONE:
CONTRACTOR ADDRESS:
ELECTRICIAN: k
HVAC: SI�11' T
PLUMBER:P'`�
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Req) 1
DESCRIPTION OF WORK:�� I� �e<✓ �.QS
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ rr
VALUATION: $ I I �o 000 TOTAL AREA: 2-ZB� HEATED AREA: I b
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
[9-16�E'WER TAP:
EJ,VGATER TAP:
OTHER TAP:
TEMP POLE
GARAGE TYPE:
SIZE
SIZE
SIZE
SINGLE ED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE 10/ TRIPLE
ATTACHED 12J DETACHED a
SIGNATURE OF APPLICANT:
Plans Examiner
Official Use Only
Zoning Official
Z.Y. y Ineet1u �(
QDAP
a
ents:
YE or NO
Energy Code Compliance Information
% Glazing of exterior walls - 1� 1 5
Insulation R value of exterior walls 3
Insulation R value of ceiling 1 (flat areas) �J
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating 1 Z
CITY OF COLLEGE STATION
WORK s-QUEST PAGE 1
REQ/JOB: WF0463024 / u01 PROJECT: REQUEST DATE: 9/24/03
PRINT DATE: 9/24/03
CREW: PRINT TIME: 9:42:57
LOCATION: 1014 BOUGAINVILLEA ST SCHSTAARR.T.DATES 9/24/03
77845 COMPLETION: 9/24/03
GEN. LOC: COLLEGE STATION LOC ID: 194642
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: KM CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN
USER D: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
3I/4" WATER 4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------