Loading...
HomeMy WebLinkAboutRMDL2003-02845 SCOTT & WHITE MRI 1700 UNIVERSITY DR E BUIDING PERMITf COMMERCIAL CO GROUP Bridgette George Anthony Hamilton Fire Department Pete Garcia Lance Sims Email sent - Notes: Susan Stanley - Re: 1700 University Dr F oft and White MRI Page 1 From: Pete Garcia To: Susan Stanley Date: 1/7/2004 3:34:53 PM Subject: Re: 1700 University Dr E No issues found, everything OK Scott and White MRI >>> Susan Stanley 1/5/2004 12:21:44 PM >>> New MRI room. Calling for CO BP # 03-2845 Susan Stanley City of College Station CSR Development Services sstanlevCaD-cstx.aov 979-764-3741 CC: Anthony Hamilton; Bridgette George; Gina Carrillo; Mandi Alford; Susan Stanley Susan Stanley -1700 University Dr E Scc From: Susan Stanley To: commercial group Date: 1/5/200412:21:48 PM Subject: 1700 University Dr E Scott and White MRI New MRI room. Calling for CO BP # 03-2845 Susan Stanley City of College Station CSR Development Services sstanley@cstx.gov 979-764-3741 PREPARED 12/31/03, 12:10:54 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/31/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 1700 UNIVERSITY DR E SUBDIV: BELMONT PLACE #2 TENANT, NBR: SCOTT AND WHITE MRI CONTRACTOR BRITT RICE COMPANY PHONE : (979) 693-4076 OWNER PHONE : PARCEL - - APPL NUMBER: 03-00002845 COMMERCIAL, REMODEL/RENOVATION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 10/03/03 OC BLDG, FRAMING TIME: 17:00 10/06/03 AP 10/02/2003 03:32 PM MALFORD PARTIAL ULTRA SOUND IN TOILET AREA B1__ 02 10/10/03 OC BLDG, FRAMING TIME: 17:00 10/10/03 AP 10/10/2003 03:59 PM MALFORD partial in file room and full in reception area oscar to sign B120 01 11/19/03 OC BLDG, FRAMING -PARTIAL TIME: 17:00 11/20/03 AP 11/19/2003 09:25 AM GCARRILLO $115 03 12/05/03 OC BLDG, FRAMING TIME: 17:00 12/05/03 AP 12/05/2003 11:46 AM SSTANLEY MRI ROOM B125 01 12/31/03 / BI BLDG, FINAL TIME: 17:00 �SrQ' /jr 03 12/31/2003 11:09 AM SSTANLEY -------------------------------------- COMMENTS AND NOTES-------------------------------------- Gina Carrillo 'Re: Scott & White Remodel calling.for CO Page 1 From: Raymond Olson To: Gina Carrillo Date: 2/12/2004 8:00:59 AM Subject: Re: Scott & White Remodel calling for CO This is a true statement, let it go, let it go, let it go. >>> Gina Carrillo 02/11/04 02:33PM >>> Don Lys with Britt Rice Co., called and said that you had gone out and resolved the issues with the fire alarm system? Gina Carrillo - Re: Scott & White Remodel calling for CO Page 1 From: Raymond Olson To: Anthony Hamilton; Bridgette George; Eric Hurt; Gina Carrillo; Jerry Duffey; Lance Simms; Pete Garcia; Steve Smith Date: 1 /30/2004 11:11:25 AM Subject: Re: Scott & White Remodel calling for CO Steve Smith said that there was issues with the fire alarm system. >>> Gina Carrillo 01/30/04 10:48AM >>> BP # 03-2845 1700 University Dr E. First email was sent on 01/05/2004. Are there any outstanding issues with anyone? CC: Mandi Alford; Melissa Rodgers; Susan Stanley Gina Carrillo - Re: Scott & White Remodel calling for CO Page 1 From: Anthony Hamilton To: Gina Carrillo Date: 1 /30/2004 11:55:51 AM Subject: Re: Scott & White Remodel calling for CO It's OK >>> Gina Carrillo 01/30/2004 10:48:13 AM >>> BP # 03-2845 1700 University Dr E. First email was sent on 01/05/2004. Are there any outstanding issues with anyone? CC: Devel Service Front Counter; Peter G Garcia BUILDING PERMIT -L -TB COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002845 Date 9/09/03 Property Address . . . . . . 1700 UNIVERSITY DR E Property ID . . . . . . . . . - - R # .• Tenant nbr, name . . . . . . SCOTT AND WHITE MRI/� Application description . . . COMMERCIAL, HOSPITALS & INSTITUTIONS Subdivision Name . . . . . . BELMONT PLACE #2 Property Use . . . . . . . . Property Zoning . . . . . . . BUSINESS COMMERCIAL Application valuation . . . . 355737 Owner I Contractor ------------------------ ------------------------ BRITT RICE COMPANY DON LYS 3002 D LONGMIRE DRIVE COLLEGE STATION TX 77845 (979) 693-4076 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . **NEEDS TO BE ENTERED** Other struct info . . . . . EXTERIOR WALL TYPE NA IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE NA HEATED AREA .10 INTERIOR WALL TYPE SHEETROCK SEWER TYPE NA SERIAL ZONES 184.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 1228.00 Plan Check Fee .00 Issue Date . . . . 9/09/03 Valuation . . . . 355737 Expiration Date . . 3/08/04 Qty Unit Charge Per Extension BASE FEE 460.00 256.00 3.0000 THOU BLDG, VAL 100001-500000 768.00 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS POST PERMIT CARD ON JOB SITE see revise floor plan for dressing room. Fee summary Charged ----------------- ---------- ------- BUILDING DEPT RE RESFNT4 APPLICANT: Paid Credited Due ---------- ---------- ---------- E: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Page 2 Application Number . . . . . 03-00002845 Date 9/09/03 Permit Fee Total 1228.00 1228.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 1228.00 1228.00 .00 .00 ----------------------------------------- ;-- :;� 0"o ---- VAO� BUILDING DEPT REPRESENTATIVE: APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: P no �� ��SC'�-S l l' la ForOfficeUse0* DATE: O 1nQ �� S - 2 W APPLICATION # - 0�8 TEMP POLE # LOT BLOCK SUBDIVISION SEC/PH //PH BUSINESS/OWNER NAMES- cnoE -4 W 14M C- .dWic- PHONE: (jglI - 3�$� CONTRACTOR/HOMEOWNER: l 1t t c�,LC C� I�Pf)W PHONE: �o�. Jf LAO(# CONTRACTOR ADDRESS: `�O�Z _ Loi�CY'o ac-, DL k �w ELECTRICIAN --Ill 2kQ6 PLUMBER: tC - 7— STZGS HVAC ZC Q- ASI_ZXcs GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: ASV—\ _ I C_Lk% \ Ca HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 355 ] 6 - 60 TOTAL AREA: HEATED AREA: (Cost of Ldbor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE: RILE SIZE Sim SINGLE ATTACHED n SIGNATURE OF APPLICANT: Plans Examiner NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: TRIPLE a CARPORT Okla/ Usd Comments: YES or NO Zoning Official PI Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating Environmental Concerns Incorporated * Asbestos/Lead Management & Environmental Consulting ASBESTOS -CONTAINING BUILDING MATERIALS FINDINGS AND RECOMMENDATIONS REPORT SCOTT AND WHITE BC2 CLINIC 1700 UNIVERSITY DRIVE BRYAN-COLLEGE STATION, TEXAS I. INTRODUCTION On March 29, 2000, Environmental Concerns, Inc. (ECI) inspected the Scott and White BC2 Clinic (the Site) located at 1700 University Drive in Bryan -College Station, Texas, for asbestos - containing materials (ACM). ECI conducted this non-destructive inspection under an agreement with Mr. Schulyn Huston, construction manager for Scott and White Memorial Hospital in Temple, Texas. Texas Department of Health (TDH)-licensed Asbestos Inspectors Ron Hogan and Ray Hogan inspected the Site and collected bulk samples. II. METHODS AND SAMPLING STRATEGY ECI's Asbestos Inspectors viewed all accessible spaces at the Site and touched building materials to determine the location, condition, and friability of observed suspect ACM. The investigation began at the front entrance and progressed from there. ECI has had extensive experience with older buildings that have been abated during demolition or renovation projects. In almost every abatement project, demolition uncovered additional asbestos -containing materials behind concealing walls, floors, and ceilings. ECI is not responsible for omitting asbestos materials concealed by unknown false ceilings, walls, chases, inaccessible areas, etc. Samples of suspect ACM were collected from homogeneous areas. Homogeneous areas were determined to be material areas uniform in color and texture that were installed at the same time by the same contractor. The older the building and the more alterations that have occurred, the greater the number of small and irregular homogeneous areas. Conversely, homogeneous areas could extend through several buildings built at the same time. 6600 Sanger Avenue * Suite 5 * Waco, Texas 76710 * Tel (254) 772-2028 * Fax (254) 772-1726 Once homogeneous areas were determined, samples of suspect materials were collected in a random manner from representative areas, which would cause the least disturbance to the aesthetic and functional purpose of the material. The collected samples were sent to a licensed and accredited laboratory for analysis. All surfacing materials were considered suspect. All thermal system insulation that was a white paste, mud, powder, or pre -formed material was considered suspect. Specifically excluded from sample collection were the obvious non -asbestos -containing insulation such as fiberglass, foam rubber, styrofoam, and urathanes. All materials were searched for by inspecting each accessible room and space and by checking above ceilings -and below slabs. Only non-destructive searches were conducted There may be residual materials from previous insulations in wall chases and behind concealing plaster or brick that were not accessible by the inspectors. There was also a possibility that suspect materials contained within a "sandwich" of other materials were not found by the inspectors. The only alternative to this procedure was to core all materials "daylight -to -daylight", rip open wall chases and tear down concealing plaster and/or brick. ECI felt that destructive sampling was not in the Clinic's best interest and not in the spirit of the AHERA regulation. If at a later date, specific areas of demolition need to occur in association with renovation activities, further investigation of areas considered none accessible at the time of this inspection and possible confirmation sampling will need to take place. In the inspection process, only major components of construction and insulation were inspected and sampled. For instance, if the major component of a thermal system was fiberglass and all fittings sampled were non -asbestos -containing, each individual fitting was not inspected. There is a possibility that some selected individual fittings that were not sampled would be asbestos - containing, and it would not be detected. Conversely, if any fitting sampled came back asbestos - containing, all would be considered asbestos -containing, although there may be some that were not. Major fire/smoke stop materials used to seal penetrations in walls, floors and ceilings would be sampled if extensive; however, it would be cost prohibitive, if not impossible, to sample each sealant. Similar conditions exist with all minor patching materials throughout a building. All that were identifiable were sampled, but a possibility exists that some were overlooked. The inspection was performed in the spirit and the letter of the AHERA regulation. Due diligence was exercised by the inspectors and all suspect major building material components should have been identified and sampled. The possible exceptions include inaccessible areas or minor applications that may have been overlooked. If any material cannot be positively identified as non -asbestos -containing by this report, it should be treated as asbestos until a sample can be collected and analyzed by a licensed and accredited laboratory. III. ASBESTOS -CONTAINING MATERIALS ECI's Asbestos Inspectors discovered no materials containing 1% or more fibrous asbestos at the Site. 6600 Sanger Avenue o Suite 5 a Waco, Texas 76710 • Tel (254) 772-2028 + Fax (254) 772-1726 IV. NON ASBESTOS -CONTAINING MATERIALS The following products found at the Site contained less than 1% asbestos when analyzed by PLM: Texture on Sheetrock Joint Compound Lay -in Ceiling Tiles Sheetrock Cove Base Cove Base Mastic Penetration Mud Sink Coating Carpet Adhesive Exterior Plaster Mortar 12x12 Floor Tile Yellow Flooring Mastic Ceramic Tile Grout White Coating on Pipe/Duct Insulation V. IMMEDIATE HEALTH HAZARD CONSIDERATIONS Friability is the characteristic of a substance describing its ability to be crumbled, pulverized, or reduced to powder by hand pressure. When applied to asbestos -containing substances, friability describes the substance's fiber release potential. Since asbestos becomes a health hazard when inhaled or ingested, the more likely an asbestos -containing substance is to crumble when disturbed, the greater its hazard potential. The Owner should maintain any area open to air movement free of friable material. Broken or loose fibrous materials should be cleaned up and repaired if doing so will not produce more of a fiber release hazard than already exists. According to Texas law, repairs or other "intentional disturbance of any amount of asbestos -containing material" must be performed by an Abatement Contractor licensed by the Texas Department of Health. At the time of the inspection, ECIs' Asbestos Inspectors did not observe any material, which could pose an immediate asbestos health hazard to anyone entering the BC2 Clinic. VI. RECOMMENDATIONS Based on observations made at BC2 Clinic and results of bulk samples collected, ECI makes the following recommendations: 1. If any material cannot be positively identified as non -asbestos -containing by this report, it should be presumed to be asbestos -containing until samples can be collected by a TDH licensed asbestos inspector, and analyzed by a TDH licensed laboratory conducting Polarized Light Microscopy. Environm tall Concerns, Inc. R H gan TDH 1AC Lia#10-5376 6600 Sanger Avenue a Suite 5 o Waco, Texas 76710 a Tel (254) 772-2028 - Fax (254) 772-1726 PLM REPORT Steve Moody Micro Services, Inc. NVLAP Lab No. 102056 1510 Randolph, Suite 602 TDH License No. 30-0084 Carrollton, Texas 75006 (972) 446-9482 PAT ID # 102577 Client: Environmental Concerns, Inc. Lab Job No.: xOB-1256 Project : Scott & White, Bryan -College Station Clinic - BC2 Report Date: 03/31/2000 Project # : 122.63S / B0032901 Sample Date: 3/29100 Identification : Asbestos, Bulk Sample Analysis Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 40 CFR, Ch. 1, Pt. 763, Subpt. F, App. A Page 1 of 5 On 3/31/00, sixty-six (66) bulk material samples were submitted by Ray Hogan (TDH Lic. #10-5376) of Environmental Concerns, Inc. for asbestos analysis by PLM/DS. Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below: Sample Number Client Sample Description / Location Asbestos Content F4226 Lay -in Ceiling Tile (Fissure), Waiting Room C212, Ceiling None Detected F4227 Sheetrock, Waiting Room C212, Wall None Detected F4228 Joint Compound, Waiting Room C212, Wall None Detected F4229 White Coating on Pipe Insulation, Waiting Room C212, Ceiling None Detected F4230 Cove Base (Gray), Waiting Room C212, Wall None Detected F4231 Cove Base Mastic (Tan), Waiting Room C212, Wall None Detected F4232 Carpet Adhesive, Waiting Room C212, Floor None Detected F4233 Underneath Coating (Gray), Corridor C916A, Sink None Detected F4234 Texture on Sheetrock (Wavy), Stairwell C 160, Wall None Detected F4235 Penetration Mud (Pink), Stairwell C160, Wall None Detected F4236 Sheet Flooring (Gray Streak), Room C200, Floor None Detected F4237 Flooring Mastic (Yellow), Room C200, Floor None Detected F4238 12" x 12" Floor Tile (White w/ Black), Room C146, Floor None Detected F4239 Flooring Mastic (Yellow & Black), Room C146, Floor None Detected F4240 Sheet Flooring (Gray Streak), Room B218, Floor None Detected F4241 Flooring Mastic (Yellow), Room B218, Floor None Detected PLM REPORT Steve Moody Micro Services, Inc. NVLAP Lab No. 102056 1510 Randolph, Suite 602 TDH License No. 30-0084 Carrollton, Texas 75006 (972) 446-9482 PAT ID # 102577 Client: Environmental Concerns, Inc. Lab Job No.: xOB-1256 Project : Scott & White, Bryan -College Station Clinic - BC2 Report Date: 03/31/2000 Project # : 122.63S / BO032901 Sample Date : 3/29/00 Identification : Asbestos, Bulk Sample Analysis Test Method: Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 40 CFR, Ch. 1, Pt. 763, Subpt. F, App. A Page 2 of 5 On 3/31/00, sixty-six (66) bulk material samples were submitted by Ray Hogan (TDH Lie. #10-5376) of Environmental Concerns, Inc. for asbestos analysis by PLM/DS. Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below: Sample Number Client Sample Description / Location Asbestos Content F4242 Texture on Sheetrock (Wavy), Room B218, Wall None Detected F4243 Underneath Coating (Gray), Room B 174, Sink None Detected F4244 12" x 12" Floor Tile (White w/ Black), Room B164, Floor None Detected F4245 Flooring Mastic (Black), Room B 164, Floor None Detected F4246 Lay -in Ceiling Tile (Fissure), Corridor B 149, Ceiling None Detected F4247 Sheetrock, Corridor B149, Wall None Detected F4248 Joint Compound, Corridor B 149, Wall None Detected F4249 Cove Base (Gray), Corridor A116, Wall None Detected F4250 Cove Base Mastic (Tan), Corridor A116, Wall None Detected F4251 Carpet Adhesive / Floor Fill, Corridor A 116, Floor None Detected F4252 White Coating on Pipe Insulation, Corridor A116, Ceiling None Detected F4253 Penetration Mud (Pink), Mechanical Room A118, Floor None Detected F4254 Gray Mastic, Seams, Mechanical Room Al 18, Duct Work None Detected F4255 Gray Mastic, Scams, Mechanical Room B140, Duct Work None Detected F4256 Ceramic Tile Grout, Restroom A143, Wall None Detected F4257 Ceramic Tile Grout, Restroom A143, Floor None Detected 1 PLM REPORT Steve Moody Micro Services, Inc. NVLAP Lab No. 102056 1510 Randolph, Suite 602 TDH License No. 30-0084 Carrollton, Texas 75006 (972) 446-9482 PAT ID # 102577 Client: Environmental Concerns, Inc. Lab Job No.: xOB-1256 Project : Scott & White, Bryan -College Station Clinic - BC2 Report Date: 03/31/2000 Project # : 122.63S / B0032901 Sample Date: 3/29/00 Identification : Asbestos, Bulk Sample Analysis Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 40 CFR, Ch. 1, Pt. 763, Subpt. F, App. A Page 3 of 5 On 3/31/00, sixty-six (66) bulk material samples were submitted by Ray Hogan (TDH Lic. #10-5376) of Environmental Concerns, Inc. for asbestos analysis by PLM/DS. Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below: Sample Number Client Sample Description / Location Asbestos Content F4258 Ceramic Tile Grout, Restroom C102, Wall None Detected F4259 Ceramic Tile Grout, Restroom C102, Floor None Detected F4260 Lay -in Ceiling Tile (Fissure), Corridor D207, Ceiling None Detected F4261 Sheetrock, Corridor D207, Wall None Detected F4262 Joint Compound, Corridor D207, Wall None Detected F4263 White Coating on Pipe Insulation, Corridor D207, Ceiling None Detected F4264 Cove Base (Gray), Corridor D207, Wall None Detected F4265 Cove Base Mastic (Tan), Corridor D207, Wall None Detected F4266 Carpet Adhesive (Tan), Corridor D207, Floor None Detected F4267 Ceramic Tile Grout, Restroom D205, Wall None Detected F4268 Ceramic Tile Grout, Restroom D205, Floor None Detected F4269 Lay -in Ceiling Tile (BF), Room D207, Ceiling None Detected F4270 Lay -in Ceiling Tile (BF), Room D295, Ceiling None Detected F4271 Texture on Sheetrock (Wavy), Room D295, Wall None Detected F4272 12" x 12" Floor Tile (White w/ Gray), Room D295, Floor None Detected F4273 Flooring Mastic (Black), Room D295, Floor None Detected 1 PLM REPORT Steve Moody Micro Services, Inc. NVLAP Lab No. 102056 1510 Randolph, Suite 602 TDH License No. 30-0084 Carrollton, Texas 75006 (972) 446-9482 PAT ID # 102577 Client : Environmental Concerns, Inc. Lab Job No.: xOB-1256 Project : Scott & White, Bryan -College Station Clinic - BC2 Report Date: 03/31/2000 Project # : 122.63S / B0032901 Sample Date: 3/29/00 Identification : Asbestos, Bulk Sample Analysis Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 40 CFR, Ch. 1, Pt. 763, Subpt. F, App. A Page 4 of 5 On 3/31/00, sixty-six (66) bulk material samples were submitted by Ray Hogan (TDH Lic. #10-5376) of Environmental Concerns, Inc. for asbestos analysis by PLM/DS. Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below: Sample Number Client Sample Description / Location Asbestos Content F4274 12" x 12" Floor Tile (White w/ Gray), Corridor D298, Floor None Detected F4275 Flooring Mastic (Black), Corridor D298, Floor None Detected F4276 12" x 12" Floor Tile (White w/ Gray), Corridor D298, Floor None Detected F4277 Flooring Mastic (Black), Corridor D298, Floor None Detected F4278 12" x 12" Floor Tile (White w/ Black), Room D256, Floor None Detected F4279 Sheet Flooring (Blue), Room D257, Floor None Detected F4280 Sheet Flooring (Blue), Room D257, Floor None Detected F4281 Sheet Flooring (Blue), Room D247, Floor None Detected F4282 Underneath Coating (Gray), Room D257, Sink None Detected F4283 Gray Mastic, Seams, Mechanical Room D277, Duct Work None Detected F4284 Penetration Mud (Pink), Mechanical Room D277, Wall None Detected F4285 Sheet Flooring (Gray Streak), Room C124, Floor None Detected F4286 Plaster, Exterior Surface None Detected F4287 Mortar, Exterior Surface None Detected F4288 Plaster, Exterior Surface None Detected F4289 Mortar, Exterior Surface None Detected l -- PLM REPORT Steve Moody Micro Services, Inc. NVLAP Lab No. 102056 1510 Randolph, Suite 602 TDH License No. 30-0084 Carrollton, Texas 75006 (972) 446-9482 PAT ID # 102577 Client: Environmental Concerns, Inc. Lab Job No.: x0B-1256 Project : Scott & White, Bryan -College Station Clinic - BC2 Report Date: 03/31/2000 Project # : 122.63S / B0032901 Sample Date : 3/29/00 Identification : Asbestos, Bulk Sample Analysis Test Method : Polarized Light Microscopy / Dispersion Staining (PLM/DS) EPA Method 40 CFR, Ch. 1, Pt. 763, Subpt. F, App. A Page 5 of 5 On 3/31/00, sixty-six (66) bulk material samples were submitted by Ray Hogan (TDH Lie. #10-5376) of Environmental Concerns, Inc. for asbestos analysis by PLM/DS. Copies of the lab data sheets are attached; additional information may be found therein. The results are summarized below: Sample Number Client Sample Description / Location Asbestos Content F4290 Plaster, Exterior Surface None Detected F4291 Mortar, Exterior Surface None Detected These samples were analyzed by layers. The first percentage is the overall asbestos content for the sample. Specific layer or component asbestos content is indicated when relevant. These asbestos contents should be considered when establishing policy regarding these bulk materials. Quantification, unless otherwise noted, is performed by calibrated visual estimate. Results may not be reproduced except in full. This test report relates only to the samples tested. These test results do not imply endorsement by NVLAP or any agency of the U.S. Government �(j n f W 'v`L/rp=\J .nalyst : Heather Deines Lab Director: Steve Moody Approved Signatory: ----------------------------------- Thank you for choosing Steve Moody MicroServices ---------------------------------- Sep 08 03 09:06a p.I Fax CORGAN ASSOCIATES, INC. 501 ELM STREET SUITE 500 DALLAS, TX 75202 TEL 214 748 2000 FAX 214 653 8281 EMAIL CORGAN@CORGAN.COM Date S September 2003 To Carl Warren With City Planner - College Station, Texas Fax 979.764.349E From Alain Bcaini Project 02191.0000-Scott&White College Station MP/MR1 Re Dressing Room C104 Carl, Here is the plan correction per your comment for the new MR.1 suite at the Scott & White Clinic. After reviewing it with the owner, it was decided that we would leave the door location and swing it out of the room. This resolves the issue of the door swinging into the turning space. Please let me know if any other issues need to be resolved. Thank you, Alain Beaini 214.757,1675 2 page(s), including cover sheer. GAD00\02191 \0000\00000\as\CA100035_rAx.%va I m