HomeMy WebLinkAboutRES2003-02839PREPARED 12/16/03, 12:09:46 INSPECTION TICKET PAGE 17
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/16/03
------------------------------------------------------------------------------------------------
ADDRESS . : 2322 KENDAL GREEN CIR SUBDIV: CASTLEGATE SEC 4 PH 2
CONTRACTOR : 5 STAR HOMES PHONE : (979) 696-0335
OWNER : CHARLES THOMAS HOMES INC PHONE :
PARCEL : 184200-2402-0610
APPL NUMBER: 03-00002839 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 10/16/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
10/16/03 AP 10/15/2003 02:34 PM SSTANLEY
set back per strings. slab ground Q left back corner
B O1 10/31/03 DS BLDG, FRAMING TIME: 17:00
11/03/03 10/30/2003 02:07 PM MALFORD
B125 01 12/16/03 BLDG, FINAL TIME: 17:00
12/16/2003 09:58 AM MALFORD
-------------------------------------- COMMENTS AND NOTES----------------------------------
Mandi Alford -Insulation request insperesultG 2322 Kendal Green #032839r �� Page 14
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 11/3/2003 3:28:39 PM
Subject: Insulation request inspection result, 2322 Kendal Green, #03-2839
Print for File
Inspected insulation, 2322 Kendal Green, #03-2839, 5 Star Homes, 11-3-03
Inspection result: Inspected OK for Good Cents
Notes:
Damper missing from hall bath exhaust fan.
CC: Alford, Mandl
City
of College S`-�tion
WORK
9QUEST
PAGE
1
REQ/JOB:
WF0468229 /
001 PROJECT:
REQUEST DATE:
10 1/03
PRINT DATE:
10/2 /03
CREW:
PRINT TIME:
7:3 -23
SCHEDULE
DATES
LOCATION:
2322 KENDAL
GREEN CIR
START:
10/21/03
77845
COMPLETION:
10/21/03
GEN. LOC:
COLLEGE STATION LOC ID: 192804
REF NBR:
REQ DEPT:
DE -BUILDING
INSPECTION PRIORITY:
NORMAL
RE UESTOR:
5 STAR HOMES
ORIGIN:
CUSTOMER -WALK
IN
US R ID:
MALFORD
AUTH: MALFORD WORK TYPE:
ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Tasko cde: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
City of College Station
WORK QUEST
REQ/JOB: WF0466885 / 001 PROJECT:
CREW:
LOCATION: 2322 KENDAL GREEN CIR
77845
GEN. LOC: COLLEGE STATION LOC ID:
PAGE 1
13/03
PRQINTST DATE: DATTE:-0%13%03
PRINT TIME: 11:1q:17
SCHSTAARR.T.DA10/13/03
COMPLETION: 10/13/03
192804
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: 5 STAR HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE
3/4"WTR, 411SWR
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4"WTR, 411SWR
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
I
,T N
i 1101 TEXA"�` ._
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00002839 Date 10/13/03
Property Address . . . . . . 2322 KENDAL GREEN CIR
Property ID 184200-2402-0610
R # . . . . . . . . R110968
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . CASTLEGATE SEC 4 PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . PLANNED DEVI, HOUSING
Application valuation . . . . 101508
Owner Contractor
------------------------ ------------------------
CHARLES THOMAS HOMES INC 5 STAR HOMES
PO BOX 10106 RUSSELL ERICKSON
COLLEGE STATION TX 778420106 PO BOX 9229
COLLEGE STATION TX 77842
(979) 696-0335
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE CONCRETE
NUMBER OF GARAGE BAYS 2.00
HEATED AREA 1538.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . MR
Permit Fee . . . . 466.00 Plan Check Fee .00
Issue Date . . . . 10/13/03 Valuation . . . . 101508
Expiration Date . . 4/11/04
Qty Unit Charge Per Extension
BASE FEE 460.00
2.00 3.0000 THOU BLDG, VAL 100001-500000 6.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00002839
Page 2
Date 10/13/03
Special Notes and Comments
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . . . . . . . .
Fee summary Charged
BUILDING DE
APPLICANT:
SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Paid Credited Due
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number
03-00002839
Date 10/13/03
Permit Fee Total
466.00
466.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1216.00
1216.00
.00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . .
Property Address . . . .
Property ID . . . . . . .
Application description .
Subdivision Name . . . .
Property Use . . . . . .
Property Zoning . . . . .
Application valuation . .
. 03-00002840
. 2322 KENDAL GREEN CIR
. 184200-2402-0610
. TEMP POLE
CASTLEGATE SEC 4 PH 2
. RESIDENTIAL
PLANNED DEVL HOUSING
. 0
Date 10/13/03
Owner Contractor
------------------------ ------------------------
CHARLES THOMAS HOMES INC 5 STAR HOMES
PO BOX 10106 RUSSELL ERICKSON
COLLEGE STATION TX 778420106 PO BOX 9229
COLLEGE STATION TX 77842
(979) 696-0335
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . MR
Permit Fee . . . . 20.00
Issue Date . . . . 10/13/03 Valuation . . . . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
Fee summary Charged
----------------- ----------
Permit Fee Total 20.00
Other Fee Total 45.00
Grand Total 65.00
Paid Credited Due
------------------------------
20.00 .00 .00
45.00 .00 .00
65.00 .00 .00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: `Z
For Office Use OMy2
DATE: V q- D S- fly� J
APPLICATION # - 11'��
TEMP POLE # _(J 8
in -,J--
LOT BLOCK SUBDIVISION G�as�f� _ SEC/PH
BUSINESS/OWNER NAME: `�f�..a�'r�� ��.i..1��s�,•-, PHONE:��
CONTRACTOR/HOMEOWNER: j `Zro --+�5 PHONE:
CONTRACTOR ADDRESS: ��l�o}C I l t 3 Cm �l II�.�. ZZ.
/ Z.
ELECTRICIAN: �vc 'r�� . PLUMBER:
HVAC: G,_-oA.t V A/- GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) EW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHRIECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECTjREGISTRATION# EABPR.,
VALUATION: $ /0%5C� TOTAL AREA: `_2I22
(Cost of Labor and Materials)
2raPUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
El"SEWER TAP:
INTERIOR WALL TYPE:
�ATER TAP:
SIZE
// EXTERIOR WALL TYPE:
SIZE
HEATED AREA: /�53.9'
OTHER TAP: FOUNDATION TYPE:^]<
SIZE
TEMP POLE ROOF TYPE: J�_
�k.
GARAGE TYPE: SINGLE F__j DOUBLE TRIPLE F7
ATTACHED �ETACHED a CARPORT a
SIGNATURE OF APPLICANT:
Official Use Only
CHJqJ63
Plans Examiner
Zoning Official
ents:
(YOES' r NO
Energy Code Compliance Information
m%
% Glazing of exterior walls 1
Insulation R value of exterior walls'' _S
Insulation R value of ceiling 1 (flat areas) q1369
Insulation R value of ceiling 2 (vaulted areas/no attic) 10A
Glazing SHGC , 4 DC, 1 Q5S
Glazing U-Factor
R value of ductwork l
A/C SEER rating 1�J
:0
Permit Number
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb Checked By/Date
TITLE: Gehring Residence
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 09/04/03
DATE OF PLANS: May 03
PROJECT INFORMATION:
New home
COMPANY INFORMATION:
5 Star Homes
NOTES:
3 Bed room 2 Bath 2 Car garage 1538 Total heated area
COMPLIANCE: Passes
A= 48
our Home 1.5%
e
Than Code
Gross
Glazing
Area or Cavity
Cont.
or Door
Perimeter R Value
R Value U Factor
UA
f
Ceiling 1: Flat Ceiling or Scissor Truss
1538 30.0
0.0
54
Wall 1: Wood Frame, 16" o.c.
1764 13.0
2.8
107
Window 1: Vinyl Frame, Double Pane with Low E
203
0.370
75
Window 2: Vinyl Frame, Double Pane
13
0.500
7
Door 1: Solid
20
0.170
3
Door 2: Solid
19
0.040
1
Door 3: Glass
19
0.170
3
Slab 1: Unheated, 0.0' insul.
2122
0.0
2211
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 13 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed to meet the 2000 IECCCCC requirements in MECcheck Version 3.2 Release lb.
Builder/Designer� /%���''� Date �3
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 09/04/03
TITLE: Gehring Residence
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R 30.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R 13.0 cavity+ R 2.8 continuous insulation
Comments:
Windows:
[ ] 1. Window 1: Vinyl Frame, Double Pane with Low E, U-factor: 0.370
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
[ ] 2. Window 2: Vinyl Frame, Double Pane, U-factor: 0.500
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
I Comments:
Doors:
1. Door 1: Solid, U-factor: 0.170
Comments:
2. Door 2: Solid, U factor: 0.040
Comments:
3. Door 3: Glass, U factor: 0.170
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Slab -On -Grade Floors:
1. Slab 1: Unheated, R 0 (uninsulated)
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 13 SEER or higher
Make and Model Number
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] I Recessed lights must be type IC rated and installed with no penetrations or installed inside an
appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
I
Materials Identification:
[ ] I Materials and equipment must be installed in accordint to the manu&cturer's installation
instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R values, glazing U-values, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
L l I Ducts in unconditioned spaces must be insulated to R 5.
Ducts outside the building must be insulated to R 8.0.
I
Duct Construction:
L l I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
I (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
L ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
I l I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to
I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
Service Water Heating:
[ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
I water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
I of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating and Cooling Piping Insulation:
[ ] I HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Uu to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Plpes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping SystTypes Ran a 2" Runouts l" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)