Loading...
HomeMy WebLinkAboutRES2003-02830i J y� 5 )Qp - (JS w PREPARED 12/22/03, 6:52:14 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/22/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 303 CECILIA LOOP SUBDIV: EDELWEISS ESTATES PHS 13 CONTRACTOR : HUSFELD HOMES INC PHONE : (979) 696-4369 OWNER : INDIVISA CORP PHONE : PARCEL : 244000-1317-0020 APPL NUMBER: 03-00002830 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 9/29/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 9/29/03 AP 09/29/2003 04:02 PM GCARRILLO tie slab ground every 4' setback strings pulled slab ground back right B115 01 10/29/03 DS BLDG, FRAMING TIME: 17:00 10/29/03 AP 10/28/2003 02:14 PM GCARRILLO B130 01 10/29/03 CH BLDG, INSULATION TIME: 17:00 10/29/03 AP 10/29/2003 11:52 AM GCARRILLO late afternoon B125 JG1 12/ 2/03 B (EP BLDG, FINAL TIME: 17:00 1.), Q3. eC. 12/19/2003 10:56 AM GCARRILLO COMMENTS AND NOTES 3Lo CITY OF COLLEGE STATION WORK QUEST PAGE 1 REQ/JOB: WF0463339 / 001 PROJECT: REQUEST DATE: 9/25/03 PRINT DATE: 9/25/03 CREW: PRINT TIME: 9:..0:56 SCHSTA LOCATION: 303 CECILIA LOOP RT,DATES 9/25/03 77845 COMPLETION: 9/2_rg03 GEN. LOC: COLLEGE STATION LOC ID: 122450 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: HUSFELD HOMES INC ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE BUILDINC PERMIT "U COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002830 Date 9/11/03 Property Address . . . . . . 303 CECILIA LOOP Property ID . . 244000-1317-0020 R # . . . . . . . . . . . . . R102901 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS ESTATES PHS 13 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 183612 Owner Contractor ------------------------ INDIVISA CORP ------------------------ HUSFELD HOMES INC 2001 KIRBY DR STE 1001 DENNIS HUSFELD HOUSTON TX 770196033 3204 LONGMIRE COLLEGE STATION TX 77845 (979) 696-4369 ------ Structure Information SINGLE FAMILY HOME ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2782.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.50 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 244.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 712.00 Plan Check Fee .00 Issue Date . . . . 9/11/03 Valuation . . . . 183612 Expiration Date . . 3/10/04 Qty Unit Charge Per Extension BASE FEE 460.00 84.00 3.0000 THOU BLDG, VAL 100001-500000 252.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR BUILDING DEPT RE�ESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101•TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00002830 Date 9/11/03 ---------------------------------------------------------------------------- Special Notes and Comments TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI PROJECTIONS (OVERHANGS) BEYOND THE EXTERIOR WALL SHALL COMPLY WITH SECTION R302.1, 2000 IRC PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. Post permit card Omit glass block on zero lot line side of house or provide fire rating information for block (min. 45 minute rating required). PROVIDE ONE HOUR RATED CONSTRUCTION FOR ZERO LOT LINE WALL ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged ---------- Paid ---------- Credited -------------------- Due Permit Fee Total 712.00 712.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1462.00 1462.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002831 Date 9/11/03 Property Address . . . . . . 303 CECILIA LOOP Property ID . . . . . . . . . 244000-1317-0020 Application description . . . TEMP POLE Subdivision Name . . . . . . EDELWEISS ESTATES PHS 13 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 0 Owner Contractor ------------------------ INDIVISA CORP ------------------------ HUSFELD HOMES INC 2001 KIRBY DR STE 1001 DENNIS HUSFELD HOUSTON TX 770196033 3204 LONGMIRE COLLEGE STATION TX 77845 (979) 696-4369 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 9/11/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged --------------------------- Paid Credited -------------------- Due ---------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DE APPLICANT: CITY OF COLLEGE STATION WORK QUEST PAGE 1 REQ/JOB: WF0460418 / U01 PROJECT: REQUEST DATE: 9/11/03 PRINT DATE: 9/11/03 CREW: PRINT TIME: 13:10:30 DULE SCHSTAART.DATES LOCATION: 303 CECILIA LOOP 9/11/03 77845 COMPLETION: 9711/03 GEN. LOC: COLLEGE STATION LOC ID: 122450 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: HUSFELD HOMES INC ORIGIN: X&TH: WORK TYPE: CUSTOMER -WALK ROUTINE IN USER ID: 4" SEWER SSTANLEY SSTANLEY 3/4" WATER 4" SEWER 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WW W.CI.COLLEG E-STATION.TX.US C� For ofio. Use Only DATE: t 0 O APPLICATION # TEMP POLE # CJ B ADDRESS/LOCATION: n 3 eC�cC t�i1l �/ calms LOT 0- BLOCK 1 SUBDIVISION G of el f ,1e I Jr -r s VY!"1�l SEC/PH13 BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: (`y" ff"fM T-t c PHONE: CONTRACTOR ADDRESS: 3P,0 4.f ,i e Oe'. C , r, 77 8 Vf- ELECTRICIAN: r k." HVAC: PLUMBER: R fK �u s GOOD CENTS (Residential only): !4er CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION OVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: S , �'• ib , STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ �' /83, &Z TOTAL AREA::* HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM D-S'EWER TAP: R ViIATER TAP: OTHER TAP: M-fEMP POLE GARAGE TYPE: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: �Z INTERIOR WALL TYPE: EXTERIOR WALL TYPE: 13 a "C FOUNDATION TYPE: S 44 0-1— 2 "44 SIZE ROOF TYPE: L'O ti SINGLE OUBLE ET_ TRIPLE a ATTACHED I14_��,DI�ACHED a CARPORT F (It SIZE 7/-/- �r SIZE SIGNATURE OF APPLICANT: Official Use Only l�s Plans Examiner Zoning Official C nts: 7E0NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls 13 Insulation R value of ceiling 1 (flat areas) '3 C> Insulation R value of ceiling 2 (vaulted areas/no attic) 3 0 Glazing SHGC . 4f Glazing U-Factor R value of ductwork A/C SEER rating % o� �-{- RESclseck Compliance Certificate 2000 IECC REScheckSoflware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\Husfeld Arbuckle.rck TITLE: Arbuckle Residence CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 09/03/03 DATE OF PLANS: 9/03/03 PROJECT INFORMATION: Lot 2 Block 17 Edelweiss Estates Phase 13 COMPANY INFORMATION: Husfeld Homes, Inc 3204 Longmire College Station, TX 77845 Ph:979-696-4369 Fax: 979-764-7919 COMPLIANCE: Passes Maximum UA = 839 Your Home UA = 707 15.7% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window. 1: Metal Frame:Double Pane with Low-E SHGC: 0.36 Window 2: Other (vtL4sS 't1,LvUC- SHGC: 0.40 Door 1: Solid Door 3: Glass SHGC: 0.36 Wall 2: Wood Frame, 16" o.c. Door 2: Solid Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2782 30.0 0.0 97 13.0 5.4 103 ip 0.640 163 18 0.600 11 48 0.310 15 0.390 28 40 13.0 0.0 18 0.150 3 90 13.0 3.6 4 301 0.640 19 SHGC: 0.36 Floor 1: SlabOn-Grade:Unheated 236 0.0 246 Insulation depth: 2.0' COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 MCC requirements in REScheckVersion 3.3 Release lb (formerly MECchec4 and to comply with the mandatory regnrements listed in the REScheckbwection Clleelti& REScheck Inspection Checkk.. 2000 IECC REScheckSoRware Version 3.5 Release lb DATE: 09/03/03 TITLE: Arbuckle Residence Bldg. Dept. Use Ceilings: [ ] ( 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation I Comments: Above -Grade Walls: C l I 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-5.4 continuous insulation Comments: [ ] I 2. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation I Comments: [ ] I 3. Wall 3: Wood Frame, 16" o.c., R-13.0 cavity + R-3.6 continuous insulation Comments: I Windows: [ l I 1. Window 1: Metal Frame:Double Pane with Low-E, U factor: 0.640 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No I Comments: [ ] ( 2. Window 2: Other, U-factor: 0.600 I For windows without labeled U-factors, describe features: I # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] I 3. Window 3: Metal Frame:Double Pane with Low-E, U-factor. 0.640 I For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ) No Comments: I Doors: [ J I 1. Door 1: Solid, U-factor: 0.310 I Comments: C l I 2. Door 3: Glass, U-factor: 0.390 Comments: [ ] I 3. Door 2: Solid, U-factor: 0.150 I Comments: 1 Floors: [ ] I 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: I Solar Heat Gain Codficient: [ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air I leakage must be sealed [ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from com ble materials. If non -IC rated, the fixture in installed with a 3" clearance from insulation. I Materials Identification: [ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ l I Materials and equipment must be identified so that compliance can be determined [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating I equipment must be provided [ ] I Insulation R-values and glazing U factors must be clearly marked on the building plans or specifications. I I Duct Insulation: [ J I Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R 8.0. I Duct Construction: L l I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). L ] ( Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. ( ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] ( Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided Service Water Heating: ( ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: L l I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock I Heating and Cooling Piping Insulation: ( ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Nan -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to V Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range (F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Lot 2 Block 17 Edelweiss Estates Ph• 13 3 o 3 Cc c it) M 400 p Arbuckle Residence 01)