Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-02822
C7- co N G _ L�4 -03 \ 0 PREPARED 12/22/03, 12:34:41 INSPECTION TICKET PAGE 14 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/22/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 4512 SAPPHIRE CT SUBDIV: STONE FOREST PH 3 CONTRACTOR : ELEGANT LIVING HOMES PHONE (979) 823-0638 OWNER : JOHNSON INVESTMENTS INC PHONE PARCEL : 585200-0306-0290 APPL NUMBER: 03-00002822 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/02/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 10/02/03 AP 10/02/2003 08:53 AM MALFORD 10/03/2003 06:49 AM MALFORD set backs per stings -slab ground Q right back B115 01 10/23/03 TB BLDG, FRAMING TIME: 17:00 10/23/03 AP 10/23/2003 11:12 AM GCARRILLO B130 01 10/27/03 DS BLDG, INSULATION TIME: 17:00 10/28/03 AP 10/27/2003 09:04 AM SSTANLEY B125 01 12/22/03 I BLDG, FINAL TIME: 17:00 11 AD,r ©G 12/22/2003 10:46 AM SSTANLEY -------------------------------------- COMMENTS AND NOTES ---------------------------------- -- 8 D�, - 3�g I CITY OF COLLEGE STATION WORK QUEST PAGE 1 i- REQ/JOB: WF0463010 / 001 PROJECT: REQUEST DATE: 9/24;103 PRINT DATE: 9/24/03 CREW: PRINT TIME: 9:10:51 SCHEDULE LOCATION: 4512 SAPPHIRE CT START:DAT9/24/03 77845 COMPLETION: 9/24/03 GEN. LOC: COLLEGE STATION LOC ID: 198674 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE CITY OF COLLEGE STATION WORK ''QUEST PAGE 1 REQ/JOB: WF0462719 / 001 PROJECT: REQUEST DPRINT ATE: 23 9//03 CREW: PRINT TIME: 11:01:15 DUL SCHSTARRT LOCATION: 4512 SAPPHIRE CT :DATES 9/23/03 77845 COMPLETION: 9/23/03 GEN. LOC: COLLEGE STATION LOC ID: 198674 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ELEGANT LIVING HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- TAP AND 3/4" WATER TAP 4" SEWER TAP AND 3/4" WATER TAP Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE _ CITY OF CO GE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002822 Date 9/23/03 Property Address . . . . . . 4512 SAPPHIRE CT Property ID 585200-0306-0290 R # . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . STONE FOREST PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 158000 Owner Contractor ------------------------ JOHNSON INVESTMENTS INC ------------------------ ELEGANT LIVING HOMES PO BOX 800 WILLIAM C MORRIS COLEMAN TX 768340800 PO BOX 7063 BRYAN TX 77805 (979) 823-0638 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE CONCRETE NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2373.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 252.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MA Permit Fee . . . . 634.00 Plan Check Fee .00 Issue Date . . . . 9/23/03 Valuation . . . . 158000 Expiration Date . . 3/22/04 Qty Unit Charge Per Extension BASE FEE 460.00 58.00 3.0000 ---------------------------------------------------------------------------- THOU BLDG, VAL 100001-500000 174.00 Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ------------------- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00002822 Page 2 Date 9/23/03 Special Notes and Comments PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE Other Fees BUILDING DE APPLICANT: . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002822 Fee summary ----------------- Permit Fee Total Plan Check Total Other Fee Total Grand Total ------------------ BUILDING D APPLICANT: Charged Paid Credited 634.00 634.00 .00 .00 .00 .00 750.00 750.00 .00 1384.00 1384.00 .00 Page 3 Date 9/23/03 Due .00 .00 .00 .00 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002823 Date 9/23/03 Property Address . . . . . . 4512 SAPPHIRE CT Property ID . . . . . . . . . 585200-0306-0290 Application description . . . TEMP POLE Subdivision Name . . . . . . STONE FOREST PH 3 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ JOHNSON INVESTMENTS INC ------------------------ ELEGANT LIVING HOMES PO BOX 800 WILLIAM C MORRIS COLEMAN TX 768340800 PO BOX 7063 BRYAN TX 77805 (979) 823-0638 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . MA Permit Fee . . . . 20.00 Issue Date . . . . 9/23/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ----------------- Paid Credited Due ---------- Permit Fee Total 20.00 ------------------------------ 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DE APPLICANT: APPLICATION FOR BUILDING PERMIT �) CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3670 (979) 764-3496 FAX YYW W.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: 4+ S 1 Z. 5cxr�.n V-N -% ce. 0 Ou LOT 2Ci BLOCK (P SUBDIVISION For dike Use QMy s ceDATE APPLICATION # NL TEMP POLE #�T� �ay� 5+ '-�Lqvn BUSINESS/OWNER NAME: El gpaM UV;InG j4p* ca#'HONE CtiG-&Z3-p(03,T CONTRACTOR/HOMEOWNER:nr o�UAV--' �. PHONE: CONTRACTOR ADDRESS: 0.O - i� X. —j Olo3 i rw n , Tk ELECTRICIAN: C016Q CJ" >-u� O)n EIMI PLUMBER: t+a—A Pj u yy,-j0t T' ` HVAC: oo r-e S A" Cam' GOOD CENTS (Residenttal only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK:. 0-pAsiruc,+tA-n o� hm &nAke ��L ,..l� STRUCTURE USE: IULS \CL HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: �e-s TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 1 SS©OO . TOTAL AREA: 3 fl '7 HEATED AREA: 7-3 -%3 (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM 0 SEWER TAP: If Is © WATER TAP: SIZE 314 SME ❑ OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE a ATTACHED SIGNATURE .OF APPLICANT:(f_!1.. Plans Examiner NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE TRIPLE Sid / Sh C=c -rvCk- 6-iv\rA 15hcchm* / 9-rL t' �,O,nc..r-�e+e o� irmd +a� —�,am10051 ED Offdal Use Only Comments: YES or NO Zoning Official Anergy Code, Compliance, InjFormadon o % Glazing of exterior walls - Insulation R value of exterior- -walls InsulatiorfIR value of ceiling 1(flat areas) Insulation R value "of ceiiirlA 2 (vaulted areas/no attic) NA Glazing SHGC .�3. . Glazing ,U-Factor I7 value of ductwork A/C SEER, rating . MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release I TITLE: Plan 2338 The Gray Residence CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 09/03/03 DATE OF PLANS: Aug 03 PROJECT INFORMATION: 4512 Sapphire Court College Station, Texas 77845 COMPANY INFORMATION: ELH-Elegant Living Homes, Inc. P. O. Box 7063 Bryan, Texas 77805 NOTES: Please call when ready: Cindy 979-823-0638 or 777-0703 Bill 777-2045 COMPLIANCE: Passes Maximum UA = 536 Your Home = 413 22.9% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Exterior Wall 1: Wood Frame, 16" o.c. Window: 3070: Other Window: 3060: Other Window: 6020: Other Window: 6010: Other Window: 3050: Other Window: 3080: Other Window: 4040: Other Door: 3/0: Solid Door: 2/8: Solid Air Conditioner 1: Electric Central Air, 12 SEER Gross Area or Perimeter 2373 2003 84 108 12 6 30 72 16 20 36 03-a001;201 Permit Number Checked By/Date Glazing Cavity Cont. or Door R-Value R-Value U-Factor UA 0.0 30.0 13.0 0.0 74 133 0.600 50 0.600 65 0.600 7 0.600 4 0.600 18 0.600 43 0.600 10 0.170 3 0.170 6 COMPLIANCE STATEMENT: The proposed building desiIit described here is consistent with the building plans, specifications, and other calculations submitted with the permapplication. The proposed building has been designed to meet the 2000 IECC requirements in MECcheck rsion 3.2 Release lb. Builder/Designer Date ' 3 / 4 MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 09/03/03 TITLE: Plan 2338 The Gray Residence Bldg. Dept. Use I Ceilings: [ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: I Above -Grade Walls: [ ] I 1. Exterior Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: I Windows: [ ] I 1. Window: 3070: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 3' x T Window [ ] I 2. Window: 3060: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 3' x 6' Window [ ] I 3. Window: 6020: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 6' x 2' Eyebrow [ ] I 4. Window: 6010: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 6' x 1' Window [ ] I 5. Window: 3050: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Tx 5' Window [ ] I 6. Window: 3080: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 3' x 8' Window [ ] 7. Window: 4040: Other, U-factor: 0.600 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 4'x 4' OBSC SG I Doors: [ ] I 1. Door: 3/0: Solid, U-factor: 0.170 Comments: 3' x 6' 8" Fiberglass Door [ ] I 2. Door: 2/8: Solid, U-factor: 0.170 I Comments: 2'8" x 6'8" Door i Heating and Cooling Equipment: [ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordint to the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipet Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature (F) U to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts l" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)