MEMORANDUM
August 18, 2003
TO: Steve Arden, Edelweiss Gartens Venture, Via fax 846.0652
FROM: Bridgette George, Assistant Development Manager
SUBJECT: EDELWIESS GARTENS PH 5 (FP) — Construction Documents
Staff reviewed the above - mentioned engineering documents as requested. The
following page is a list of staff review comments detailing items that need to be
addressed. Please address the comments and submit the following information
for further staff review and approval of the plans:
Two (2) sets of revised construction documents.
If you have any questions or need additional information, please call Spencer
Thompson at 764.3570.
Attachments: Staff Review Comments
Cc: Michael McClure, McClure Engineering Inc., Via fax 693.2554 ✓
Case file no. 03- 00500176
Home of Texas ABM University
r
ENGINEERING REVIEW
COMMENTS No. 1
1. All public utilities must be in a PUE. PUE must be submitted to the City for
plans approval.
2. Sheet 7: Storm Drain Sta. 20 +90.19 does not meet Drainage Policy and
Design Standards (DPDS) § VI, B, 3.
3. Sheet 7: SD -J and SD -I. Riprap in channel as shown constitutes modification
to natural water course. When placing riprap in lieu of energy dissipation
structure, you must show that velocities are reduced before entering natural
channel.
4. Sheet 10: Manholes required at end of sewer line per TNRCC 317.
5. Sheet 10: Remove 6" stub at MH 5.
6. Sheet 11: Manhole 9 is in handicap ramp slope area.
7. Sheet 11: 12" sewer line is less than required 42" burial depth.
8. Sheet 12: Manhole 13 is in handicap ramp slope area.
9. Sheet 13: Manhole 18 does not comply with TNRCC 317. Tops of different
size pipes must be aligned.
10. Sheet 14: End of sewer line does not meet TNRCC 317.
11. Sheet 14: 3 -36" culverts do not appear anywhere else in plan set. Remove.
12. Sheet 17: Inset A. Change to 6 "x8" tee and 8" valve.
13. Sheet 19. Remove "Future Reinforced Concrete Flume ".
14. Sheet S1: 2" sand cushion required on sidewalk detail.
Reviewed by: Spencer Thompson Date: August 14, 2003
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must
be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on
these plans that have not been pointed out to the City of College Station will constitute a
completely new review.
Page 2 of 2
CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
College Station, Texas 77842
COLLEGE STATION Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
August 4, 2003
TO: Steve Arden, Edelweiss Gartens Venture, Via fax 846.0652 -
FROM: Bridgette George, Assistant Development Manager
SUBJECT: EDELWIESS GARTENS, PHASE 5 (FP) - Final Plat
Staff reviewed the above - mentioned final plat as requested but had to stop review due
to an incomplete submittal. The following page is a preliminary list of staff review
comments detailing items that need to be addressed. Please address the comments
and submit the following information by an established deadline to be scheduled for a
future Planning & Zoning Commission meeting:
Two (2) copies of the revised final plat.
If you have any questions or need additional information, please call Spencer
Thompson or myself at 764.3570.
Attachments: Staff review comments
cc: Michael McClure, McClure Engineering Inc., Via fax 693.2554 ✓
Case file #03- 00500176
Home of Texas AB&M University
STAFF REVIEW COMMENTS NO. 1
Project: EDELWIESS GARTENS, PHASE 5 (FP) - 03- 00500176
Stop Review for incomplete items.
ENGINEERING
1. This phase of Edelweiss is dependent on public sewer service from the Westfield
Development. However, the sewer must be in an easement. In order to obtain Final
Plat approval, on off -site easement must be dedicated.
2. The Final Plat does not match the approved Preliminary Plat. An 8" waterline
connection to Victoria through Phase VI is not shown on the submitted plans.
Reviewed by: Spencer Thompson Date: July 31, 2003
ELECTRICAL
1. Developer installs conduit per city specs and design.
2. Developer provides 30' of #4 rigid conduit for riser poles. Developer installs
first 10'. City installs remainder.
3. Developer installs street lighting per city specs and design.
4. Developer installs pull boxes as per city specs and design.(pull boxes
provided by the city.
5. Developer provides digital AutoCAD 2000i version of plat and /or site plan.
email to rbolinAcstx.gov
6. Developer provides temporary blanket easement for construction
purposes.
7. Developer provides easements for electric infrastructure as installed for
electric lines (including street lights).
Reviewed by: Ronnie Bolin Date: 7 -30 -03
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must be explained in your
next transmittal letter and "bubbled" on your plans. Any additional changes on these plans that have not been pointed out
to the City, will constitute a completely new review.
Page 2 of 2
a ,
CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
COLLEGE STATION College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
August 26, 2003
TO: Steve Arden, Edelweiss Gartens Venture, Via fax 846.0652 ✓
FROM: Bridgette George, Assistant Development Manager
SUBJECT: EDELWEISS GARTENS PH 5 (FP) - Final Plat
Staff reviewed the above - mentioned final plat as requested. The following page is a list
of staff review comments detailing items that need to be addressed. Please address
the comments and submit the following information by Monday, September 8, 10:00
a.m. to be placed on the next available Planning and Zoning Commission meeting
scheduled for Thursday, September 18, 2003, 7:00 p.m. in the City Hall Council
Chambers, 1101 Texas Avenue.
Two (2) copies of the revised final plat; and,
One (1) Mylar original with the appropriate signatures.
If you have any questions or need additional information, please call me at 764 -3570.
Attachments: Staff review comments
cc: Michael McClure, McClure Engineering Inc., Via fax 693.2554
Case file #03- 00500176
Home of Texas A &M University
1
STAFF REVIEW COMMENTS NO. 2
Project: EDELWEISS GARTENS PH 5 (FP) - 03- 00500176
ENGINEERING
1. Final Plat does not conform to the Approved Preliminary Plat. The property line
along the south boundary has shifted. Please refer to Preliminary Plat approved by
P &Z in June of this year.
2. Show all off -site easements for this plat.
3. Change P &Z Certification to be signed by Chairman only. Remove "ATTEST ".
Reviewed by: Spencer Thompson Date: August 21, 2003
NOTE: Any changes made to the plans, that have not been requested by the City of College Station,
must be explained in your next transmittal letter and "bubbled" on your plans. Any additional
changes on these plans that have not been pointed out to the City, will constitute a completely
new review.
2 of 2
CITY OF COLLEGE STATION
DEVELOPMENT SERVICES
1101 Texas Avenue South, PO Box 9960
COLLEGE STATION College Station, Texas 77842
Phone 979.764.3570 / Fax 979.764.3496
MEMORANDUM
September 16, 2003
TO: Steve Arden, Edelweiss Gartens Venture, Via fax 846.0652
FROM: Bridgette George, Assistant Development Manager
SUBJECT: EDELWEISS GARTENS PH 5 (FP)
Staff reviewed the above - mentioned engineering documents as requested and is
ready to stamp the plans. Please submit the following information for the plans to
be stamped approved:
One (1) set of construction documents.
Thank you.
Attachments: Staff Review Comments
Cc: Michael McClure, McClure Engineering Inc., Via fax 693.2554
Case file no. 03- 00500176
Home of Texas A&M University
EDELWEISS GARTENS PH 5 (FP) (03- 00500176)
ENGINEERING REVIEW
COMMENTS No. 2
1. Please submit additional plan sets to be stamped. The City currently has 2
sets. The City needs one additional set for its use. Submit additional sets
needed for your use.
2. The Development Permit will need to be signed by the property owner or
contractor in order to pick -up stamped plans.
Reviewed by: Spencer Thompson Date: September 15, 2003
NOTE: Any changes made to the plans, that have not been requested by the City of College Station, must
be explained in your next transmittal letter and "bubbled" on your plans. Any additional changes on
these plans that have not been pointed out to the City of College Station will constitute a
completely new review.
Page 2 of 2