HomeMy WebLinkAboutRES2003-02820City of College Station
WORK REQUEST
REQ/JOB: WF0468230 / 001_- PROJECT:_
CREW:
PAGE
1
REQUEST DATE:
l D/ 21 / 0 _1
PRINT DATE:
PRINT TIME:
10/21/03'
7:31:28)-
SCHEDULE
DATES
LOCATION: 4417 EDINBURGH PL START:
77845 COMPLT ON: 1OA21403
GEN. LOC: COLLEGE STATION LOC ID: 193262
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: J D B CONTRACTING ORIGIN: CUSTOMER -WALK IN
USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
J' BUILDING PERMIT ip
l -ES
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00002820 Date 9/25/03
Property Address . . .
. . . 4417 EDINBURGH PL
Property ID
. . 184200-2101-0230
R # . . . . . . . . . .
. . . R111146
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . CASTLEGATE SEC 1 PH 2
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . PLANNED DEVL HOUSING
Application valuation .
. . . 170000
Owner
Contractor
------------------------
WELCH ' LEONARD W &
------------------------
J D B CONTRACTING
MELISSA MOEHLMAN WELCH
BUBBA BISHOP
3722 SHIRLEY DR
2116 FOUNTAIN AVE.
BRYAN TX
778080957 BRYAN
TX 77801
(979) 822-6317
--------------------------
Structure Information -------------------------
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
CONCRETE
NUMBER OF GARAGE BAYS
3.00
HEATED AREA
2204.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
SERIAL ZONES
249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . GC
Permit Fee . . . .
670.00 Plan Check Fee
.00
Issue Date . . . .
9/25/03 Valuation . . .
. 170000
Expiration Date . .
3/24/04
Qty Unit Charge Per Extension
BASE FEE 460.00
70.00 3.0000 THOU BLDG, VAL 100001-500000 210.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ADDRESS ON BUILDING: FRONT - 5" HIGH NUMBERS
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
BUILDING DEP REPRESEN IVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIO]
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00002820 Date 9/25/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR
BUILDING DEA"I' REPRESENTATIVE:.
l./ In • n i%
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIO.
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 03-00002820 Date 9/25/03
----------------------------------------------------------------------------
Special Notes and Comments
SECTION 1003.3.3 (2000 IBC) AS APPROPRIATE
(stairs as drawed on plan is incorrect, narrow edge
of steps shall be a min. of )(") (!"
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees
Fee summary Charged
Permit Fee Total 670.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1420.00
SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Paid Credited Due
---------- ---------- ----------
670.00
.00
.00
.00
.00
.00
750.00
.00
.00
1420.00
.00
.00
-------------------------------------------------
BUILDING DEIT REPRESENT FIVE:
QD
APPLICANT: .�/li(.c� i► i
CITY OF COLLEGE STATION
WOKI EQUEST
PAGE
1
REQ/JOB: WF0463450 / 001 PROJECT:
REQUEST DPRINT ATE:
9f25f03
CREW:
PRINT TIME:
11:58:18
SCHSTARRT.DATES
DULLOCATION:
4417 EDINBURGH PL
9/25/03
77845
COMPLETION:
9/25/03
GEN. LOC: COLLEGE STATION LOC ID: 193262
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR: JDG CONTRACTING ORIGIN:
CUSTOMER -WALK
IN
USER D: GCARRILLO AUTH: GCARRILLO WORK TYPE:
ROUTINE
32%4" WATER 4" SEWER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID
Assigned Department: OT-CUSTOMER SERVICE
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX.0 S
ADDRESS/LOCATION: 44 1 —7 ed
LOT BLOCK �_ SUBDIVISIONS
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWN
CONTRACTOR ADDRESS:
ELECTRICIAN: l /)gsoh;
HVAC: /'CnGi&�50n
M C)i
`W PLUME
GOOD
For W" Use Only M
DATE: M_ 05 - ®1-d
APPLICATION # O3 `af5 a V
TEMP POLE # -
v SEC/PH
PHONE: 04A A -& 31r 7
% PHONE:
B- 7 9 c� 1
(Residential only):
CLASS OF WOE k
ACCESSORY/STORAG� �r LOCATION RE -ROOF (Total/Partial)
ADDITION % MOVING- SHELL ONLY
DEMOLITION (Asbestos �P' y) NEW,C /6NSTRUCTION SLAB ONLY
DUPLEX (Landscape lans REMODEURENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WO K: neco harne, CA czpi crv*�
STRUCTURE USE: 1 * i 1 ram; d on
HOMEOWNER ASSOCIAT ON/ ITEC AL Oft IGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIPILITY TAN ARD (TAS) PROJECT RE( STRATION# EABPRJ
VALUATION: TOTAL -ARL� r85� HEATED AREA 2_ C�
(Cost o bq and Materials) `
PUBLIC SEWER / / NUMBER OF BE6F2
SEPTIC/TREATMENTSYSTEM NUMBER OF BATHROOMSS'
❑ SEWER TAP: �- ' INTERIOR WALL TYPE:
SIZE �J
WATER TAP: i4 EXTERIOR WALL TYPE: ,-�Yt%�c lL -_'
IZE
VER TAP: FOUNDATION TYPE: (;oncree. 5l 4b
SIZE
P POLE ROOF TYPE:
GARAGE TYPE: SINGLE F_� DOUBLE a TRIPLE
ATTACHED V_�-�ETACHED a CARPORT F1
SIGNATURE OF APPLICANT: -" 1341
Official Use Only ents:
in YES r NO
Plans Examiner Zoning Official
•
Energy Code Compliance Information
-% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing,SUGC
Glazing U-Factor
• 157"
R value of ductwork
A/C SEER rating
Sep-04-03 11:15A JDB antracting 97S-226318
r
Permit Number
REScheck Compliance Certificate Chedwd By/Date
2000 IECC
REScheckSoftware Version 3.5 Release id
Data filename: C:1Program Files\Check\REScheck\Weleh.rek
PROJECT TITLE: Leonard and Melissa Welch
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 09/04/03
DATE OF PLANS: July 7, 2003
PROJECT DESCRIPTION:
Section 1, Block 1, lot 23
4417 Edinburgh Place
Coilcp Station, Texas 77845
DESIGNMVCONTRACTOR:
JDB Contracting
Bubba Bishop
2116 Fountain Ave
Bryan, Texas 77801
979-822-6317
COMPLIANCE: Passes
Maximum UA = 3917
Your Home UA - 3240
15.1 % Better Than Code (UA)
Maximum SHOC = 0.40
Your SHGC = 0.40
Gross
Glazing
Area or
Cavity
Cont,
or Doan
Perimeter
R-Value
R Value U Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
1601
26.0
0.0
62
Ceiling 2: Flat Coiling or Scissor Truss
603
26.0
0.0
24
Wall 1: Wood Frame, 16" o.c.
2850
13.0
0.0
198
Window 1: Metal Frame:Double Pane with Low E
252
0.750
189
SHGC: 0.40
Door 1: Solid
182
0.350
64
Floor 1: Slab-On-Grade:Unheated
2594
0.0
2703
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 14 SEER
P.02
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the hermit atmlieation. The moosed building has been designed to meet the 2000 IECC
Sap-04-03 11:15A JDE ontracting 97 3226318 P.03
4
requirements in RESckeckVcrsioq 3.5 Role=1d (formerly i1r FUhec4 and to comply with the mandatory requirements listed in
the REScheeklnspoction ChecUst.
Buildcr/Designer Date 5� O
Sep-04-03 11:15A JDB-ontracting 97- 8226318 P.04
REScheck Inspeetlion Checklist
2000 IECC
RESchecraoftware Version 3.5 Release Id
DATE: 09/04/03
PROJECT TITLE: Leonard and Melissa Welch
Bldg. I
Dept• I
Use I
I Ceiling¢:
[ ] 1 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-20A cavity insulation
1 Comments:
( ] 1 2. Ceiling 2: Flat Ceiling or Scissor Truss, R-26.0 cavity insulation
1 Comments:
I
1 Above -Grade Walls:
[ ] 1 1, Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
I Comments:
I
1 Windows:
[ ] ! 1. Window L. Metal Frame -Double, Pane with Low-E, U-factor: 0.750
I For windows without labeled U-factors, describe features:
1 # Panes 11ramc "Type _ Thermal Break? [ ] Yes [ ] No
1 Comments:
I
Doors:
[ ] 1 1. Door 1: Solid, U-factor: 0.350
I Comments:
I
1 Floorw
[ ] I 1, Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulare )
I Comments;
I
I Heating and Cooling Equipment:
[ ] I 1- Air Conditioner 1: Electric Central Air, 14 SEER or higher
1 Make and Model Number
I
1 Solar Heat Gala Coeicient:
[ ] I Tk area weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHOC
values must be determined in accordance with the NFRC test procedure or taken Corp the default table.
I
I Air Leakage:
L ! I Joints, penetrations, and all other such openings in the building envelope that are sauu+ces of air
1 kakagc must be sealed
l ] I Rammed lights must be 1) Type IC rated, or 2) installed inside an appropriate airtight assembly
I with a 0.5" clearaum from combustible materials. If non -IC =14 the fixture must be installed with a
I 3" clearance from insulation.
I
Mai+erials identweadon:
[ ] f Materials and equipment must be installed in accordance with the mamdactumes installation instructions•
l l I Materials and equipment must be identified so that compliance can be determined.
[ ] J Manufacturer manuals for all installed heating and cooling equipment and servicc water heating
I cquipment must be provided.
[ 1 I Insulation R-values, glazing U-t'actors, and cooling equipment d iciency must be clearly marked on
I the building plans or specifications.
Sep-04-03 11:16A JDr-ontvacting 97 3226318 P.O5
i
Duet insuiation:
[ l I Mcts in unconditioned spaces must be insulated to R-5.
I Ducts outside the building must be insulated to R-8.0.
I
)Duct CoN*nK ion:
[ 1 I All joints, scams, and connections must be securely fastened with welds, gaskets. mastics
(ad1), c-plusembedded-fabric, or tapes. Duct tape is not permitted.
I Exception_ Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] I Duds shall be supported every 10 tea or in accordance with the manufactureis instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ j ( Air filters arc inquired in the return air system,
[ 1 I The HVAC system must provide a means for balancing air and water systems.
I
I Temperature Controls:
[ } I Thermostats are requited for each separate HVAC system A manual or automatic means to
I partially restrict or shut off the heating and/or cooling input to each Torre or floor shall be provided.
I Service water Heating:
[ 1 I Water heaters with vertical pipe risers must have a heat trap on both the inletand outlet unless the
I water heater has an integral heat trap or is part of a circulating system.
[ J ( Insulate circulating but water pipes to the levels in Table 1.
I
I Cimukwns not Water Systems:
[ l ( Insulate circulating hot water pipes to the levels in Table 1.
I
i Swimming Pools;
[ l i All heated swimming pools must have an On/off heater switch and require a cover unless over 20%
I of the heating ene& is from non-deplemble sour. Pool pumps require a time clock.
I
I Heating and Cooling Piping Insulation:
[ l I HVAC piping conveying fluids above 105 V or chilled fluids below 55 OF must be insulated to the
I levels in Table 2,
Sep-04-03 11:16A JOB "ontvacting 97- 8226318 P.06
Table 1: Mb hmm !Insulation ?Thickness for Ckodadng Rot Water Pipes
Insulation Thickness in Inches by Five
Sizes
Heated Water
Non-cinvlatina
Rnnouts
gEMMM Mains
end Runouts
Tem rB9M
U» to I"
Un to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Mlnunum Insulation ThicMom far RVAC. PIpem
Fluid Ten.
Insulation Thickness in inches'bv
Five W
Hof=S s elm ; es ,
RLaM. (D
2 Runants
1" and Less
1.25"
to 2" 2.5" to 4"
Rewfis Syftems
Low Presorci 'emperaume
201-250
1.0
I.5
1.5
2.0
LOW Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed Water)
Any
1.0
1.0
1.5
2.0
Cooling Symms
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Bri=
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Sep-04-03 11:15A JDI ontvaotinq 97 3226318 P.01
FAX COVER SHEET
JD8 Contracting
2116 Fountain Avenue
Bryan, Texas 77801
97"22-W17
979422-M8 (fax)
Send to: City of College Station From: Subbe Bishop
Attention: Cart Date: September 4, 2003
OMoe location: College Station, Texas OW40 location. -
Fax number: 979.7" 3496 Phone number. 979-822-6317
U UrBent .J R*ply ASAP 17 PIa*se comment U Please revive For your Information
Total pages, Including cover. 5