HomeMy WebLinkAboutRES2003-02811PREPARED 7/30/04, 12:00:45
INSPECTION
TICKET
PAGE 2
City of
College Station
INSPECTOR:
BUILDING INSPECTOR
DATE 7/30/04
------------------------------------------------------------------------------------------------
ADDRESS
. : 2070 RAVENSTONE LOOP
SUBDIV: CASTLEGATE SEC 1
PH 1
CONTRACTOR : ED FROEHLING BUILDERS
PHONE : (979) 776-8266
OWNER
: GREENS PRAIRIE INVESTORS LTD
PHONE :
PARCEL
: 184200-1101-0110
APPL NUMBER: 03-00002811 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PEWIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
9/22/03 TB
BLDG, FOUNDATION -SLAB TIME: 17:00
9/22/03 AP
09/19/2003 12:07
PM SSTANLEY
STRINGS ON SETBACKS, OK. SLAB GROUND BACK RT.
CORNER.
B115 01
10/28/03 DS
BLDG, FRAMING TIME: 17:00
10/28/03 AP
10/27/2003 04:55
PM MALFORD
A30 01
11/03/03 TB
BLDG, INSULATION
TIME: 17:00
11/03/03 AP
11/03/2003 10:37
AM MALFORD
�125 01
7/30/04
BLDG, FINAL TIME:
17:00
-?0-0 Lf 'ieg
07/30/2004 11:05
AM GCARRILLO
---------------------------------
CONTINUED ONTO
NEXT PAGE -----------------------------------
0:s — 1:?> -7
CITY OF COLLEGE STATION
WORK REQUEST
REQ/JOB: WF0463456 / 001
CREW:
PAGE 1
PROJECT: REQUEST DATE: 9/25/03
PRINT DATE: 9/25703
PRINT TIME: 12:25:30
LOCATION: 2070 RAVENSTONE LOOP SCHSTAARRT.DATES 9425403
77845 COMPLETION: 9725/03
GEN. LOC: COLLEGE STATION LOC ID: 191042
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: ED FROEHLING BUILDERS ORIGIN: CUSTOMER -WALK IN
USER D: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
3�4" WATER 4" SEWER
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
CITY OF COLLEGE STATION
WORK REQUEST
PAGE
1
REQ/JOB:
WF0461031 / 001 PROJECT:
•+ REQUEST DATE:
9/16/03
PRINT DATE:
9/16/03
CREW:
PRINT 'TIME:
7:47:20
SCHSTAARR.T.DATES
LOCATION:
2070 RAVENSTONE LOOP
9/16/03
77845 COMPLETION:
9/16/03
GEN. LOC:
COLLEGE STATION
LOC
ID: 191042
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
ED FROEHLING BUILDERS
ORIGIN: CUSTOMER -WALK
IN
USER ID:
MALFORD AUTH: MALFORD
WORK TYPE: ROUTINE
TEMP POLE PASSED
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
B_UILDING PERMIT
CITY OF COLLEGE STATIO
i%i'`I'EXAS "AVMP- w'
COLLE1GEl STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00002811
Date 9/04/03
Property Address . . .
. . . 2070 RAVENSTONE LOOP
Property ID . . . . . .
. . . 184200-0101-0110
R # . . . . . . . . . .
. . . R109180
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . CASTLEGATE SEC 1
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . PLANNED DEVL HOUSING
Application valuation .
. . . 152658
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD ED FROEHLING BUILDERS
4490 CASTLEGATE DR
ED FROEHLING
COLLEGE STATION TX
778453388 3887 HIGH LONESOME RD
COLLEGE STATION
TX 77845
(979) 776-8266
-------------------------- Structure
Information -------------------------
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
NA
HEATED AREA
2313.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
SERIAL ZONES
249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . MA
Permit Fee . . . .
619.00 Plan Check Fee
.00
Issue Date . . . .
9/04/03 Valuation . .
. . 152658
Expiration Date . .
3/03/04
Qty Unit Charge Per Extension
BASE FEE 460.00
53.00 3.0000 THOU BLDG, VAL 100001-500000 159.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
------------------------------------------------- ---------------------
BUILDING DEPT REPRESENTATIVE:
AP PL I CANT :
BUILDING PERMIT
CITY OF COLLEGE STATIOP
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 03-00002811
Page 2
Date 9/04/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged Paid Credited Due
BUILDING DEPT REPRESENTATIVE:
APPLICANT: 0—k" Xlz�
BUILDING PERMIT
CITY OF COLLEGE STATIOT
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . .
Permit Fee Total 619.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1369.00
03-00002811
619.00 .00
.00 .00
750.00 .00
1369.00 .00
Page 3
Date 9/04/03
.00
.00
.00
.00
--------------------------------------------------- -----------------------
BUILDING DEPT REPRESENTAT VE:
APPLICANT:
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEGE-STATION.TX.US
For Office Use OF*
DATE: D i{
APPLICATION # 03.281
TEMP POLE #
ADDRESS/LOCATION: =A
V�N�Sj;jLr_ GCl�
LOT _BLOCK SUBDIVISION
i.Asy `y ;�g SEC/PH�_
BUSINESS/OWNER NAME:
PHONE:
CONTRACTOR/HOMEOWNER: L fl riZOEH
Lw& PHONE: 776 - S Ua
CONTRACTOR ADDRESS: 3$$ %
if I GN L►eaNeSo/-'�E it
ELECTRICIAN: 34--5 I.EGTrZtL.
PLUMBER: 'rpIPI-F ��5 P, _AG�.rJtw"'�4
HVAC: �,r 1A1N6)/_A-.n VF SERVK-LS
GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE
LOCATION
RE -ROOF (Total/Partial)
ADDITION
MOVING
SHELL ONLY
DEMOLITION (Asbestos Survey)
NEW CONSTRUCTION
SLAB ONLY
DUPLEX (Landscape Plans
REMODEURENOVATION
SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ &�,4
VALUATION: $ ,5'26_58
TOTAL AREA: 23& HEATED AREA: 23/3
(Cost of Labor and Materials)
30w
01'PUBLIC SEWER
NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS: �-
It
1 SEWER TAP: 4
INTERIOR WALL TYPE:
SIZE
O'WATERTAP: -3#9
EXTERIOR WALL TYPE: 3%LIGK
SIZE
OTHER TAP:
FOUNDATION TYPE: SL/-4 D/V ls�Q.4DE
SIZE
TEMP POLE
ROOF TYPE: r�LPO S� �ioN �OitX: 6
GARAGE TYPE: SINGLE
DOUBLE ® TRIPLE a
ATTACHED
DETACHED F7 CARPORT FJ
SIGNATURE OF APPLICANT:G...ri
Official Use Only
4U!L)
YE orrNNOlfql!!� O
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
R - I
Glazing SHGC , 40
Glazing U-Factor 0
R value of ductwork - 6
A/C SEER rating 1 d-;9fr1L
03 - a�/1
Permit Number
REScheck Compliance Certificate Checked By/Date
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: Untitled.rck
TITLE: 2070 RAVENSTONE LOOP
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 09/01/03
DATE OF PLANS: AUGUST 14, 2003
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 715
Your Home UA = 637
10.9% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.35
Gross
Glazing
Area or
Cavity
Cont. or Door
Perimeter R-Value
R-Value U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
2313
30.0
0.0
81
Wall 1: Wood Frame, 16" o.c.
456
13.0
0.0
28
Window 1: Metal Frame:Double Pane with Low-E
97
0.650
63
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Front
Projection factor: 0.19
Door 1: Solid
20
0.400
8
Wall 2: Wood Frame, 16" o.c.
477
13.0
0.0
38
Window 2: Metal Frame:Double Pane with Low-E
14
0.650
9
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
469
13.0
0.0
26
Window 3: Metal Frame:Double Pane with Low-E
131
0.650
85
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Door 2: Glass
18
0.580
10
SHOO: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Back
Projection factor. 1.19
Wall 4: Wood Frame,16" o.c. 482 13.0 0.0 38
Window 4: Metal Frame:Double Pane with Low-E 20 0.650 13
SHGC: 0.40
Bldg. faces 135 deg. from North; Comp. orient.: Right Side
Projection factor. 0.27
Floor 1: Slab-On-Grade:Unheated 228 0.0 - 238
Insulation depth: 0.0'
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RES checkVersion 3.5 Release lb (formerly MECchec4 and to comply with the mandatory requirements listed in
the RES checkInspectiont. Checklis
Builder/Designer tPJ4-- Date
08/27/2003 WED 13:56 FAX 979 693 N54 Kevin Iculure 444 menling, tawara
WJUUJ uu4
14' P.U.E.
1* "" Pw--M 1 1
j 7.W 7S
- i
1 1
to! 10 1 Lot .4 BA=k .1
scat V - 2W
tot 12
sboffm 1. phm if
PA*ws! ed f
1ftsfdonce i 1
1 , �.4
~ S' RUM
3►5M'13- W
1� �r
BeeYf!]rb
RG►m7stwo L.00P
ar maw.. - Zf' pbmwavt
Val. 4J% fg 164
39-11�0'tAwq
.�lcG`1(/JPEEXRiN,E�R1vVG, /MC• rlXX�llfybaidcGTiir� �ir3� »8• C::a/�e ��3vn, Ter,�sTi�+i ,! �.d'
2