HomeMy WebLinkAboutRES2003-02325PREPARED 11/25/03, 7:17:02 INSPECTION TICKET PAGE 6
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/25/03
------------------------------------------------------------------------------------------------
ADDRESS . : 2111 ROLLING ROCK PL SUBDIV: EMERALD FOREST #11
CONTRACTOR SUNSET HOMES PHONE (979) 680-1033
OWNER EMERALD FOREST JOINT VENTURE PHONE
PARCEL 249000-1120-0060
APPL NUMBER: 03-00002325 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/05/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
8/06/03 AP 08/05/2003 08:32 AM SSTANLEY
SETBACKS PER STRINGS - SLAB GROUND Q RIGHT FRONT SIDE.
B1 01 9/30/03 CH BLDG, FRAMING TIME: 17:00
9/30/03 AP 09/30/2003 09:25 AM SSTANLEY
10/01/2003 06:58 AM MALFORD JUST NEED TO ADD JOIST
HANGERS Q ATTIC ACCESS
B130 01 10/01/03 CH BLDG, INSULATION TIME: 17:00
10/01/03 AP 10/01/2003 08:32 AM MALFORD
B125 01 11/25/03 D BLDG, FINAL TIME: 17:00
l((aS710 Xr OCR 11/24/2003 04:27 PM MALFORD
-------------------------------------- COMMENTS AND NOTES -------------------------------- -----
rr� 2�►0✓, i S ► ns,[ Ie�
CITY OF COLLEGE STATION
WORK QUEST
PAGE
1
REQ/JOB:
WF0442662 / 001 PROJECT:
DATETE:-
REQUESTPRINT
•8/06/03
CREW:
PRINT TIME:
7:03:57
SCHSTART.DAT8/06/03
LOCATION:
2111 ROLLING ROCK PL
77845
COMPLETION:
8/06/03
GEN. LOC:
COLLEGE STATION LOC ID: 194842
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
SUNSET HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY WORK TYPE:
ROUTINE
TEMP POLE
PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
P
1101 TEXAS A
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number
Property Address
Property ID . . . . . .
R# . . . . . . .
Application description
Subdivision Name . . .
Property Use . . . . .
Property Zoning . . . .
Application valuation .
. . . 03-00002325 Date 7/18/03
. . . 2111 ROLLING ROCK PL
. . . 249000-1120-0060
. . . R112401
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
. . . EMERALD FOREST #11
. . . RESIDENTIAL
. . . UNKNOWN
. . . 198000
Owner Contractor
------------------------ ------------------------
EMERALD FOREST JOINT VENTURE OWNER
#1
PO BOX 70 eel
KURTEN TX 778620070 OV--- tn.) ��7
------ Structure Information SINGLE FAMILY HOME
-----
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
3000.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
3.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
SERIAL ZONES
259.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
SS
Permit Fee . . . .
754.00 Plan Check Fee
.00
Issue Date . . . .
7/18/03 Valuation . .
. . 198000
Expiration Date . .
1/15/04
Qty Unit Charge
Per
Extension
BASE FEE
460.00
98.00 3.0000
THOU BLDG, VAL 100001-500000
294.00
----------------------------------------------------------------------------
Special Notes and Comments
ADD SMOKE DETECTOR(S)
PER NOTES ON PLANS
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR
FOR GAS FIRED APPLI P
------------------------------------------------
-----------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: a '-a
BUILDING PERMIT
CITY OF COLLEGE STATIOI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 03-00002325 Date 7/18/03
----------------------------------------------------------------------------
Special Notes and Comments
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
POST PERMIT CARD ON JOB SITE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP
4" CITY INSTALL
350.00
WATER TAP
3/4" CITY INSTL
400.00
Fee summary
Charged
Paid
----------
Credited
--------------------
Due
-----------------
Permit Fee Total
----------
754.00
754.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1504.00
1504.00
.00
.00
------------------------------------------------- -
--------------- - - - - - -
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATIOT"
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00002326 Date 7/18/03
Property Address . . . . . . 2111 ROLLING ROCK PL
Property ID 249000-1120-0060
R # . . . . . . . . R112401
Application description . . . TEMP POLE
Subdivision Name . . . . . . EMERALD FOREST #11
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . UNKNOWN
Application valuation . . . . 0
Owner Contractor
EMERALD FOREST JOINT VENTURE OWNER
#1
PO BOX 70
KURTEN TX 778620070
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . SS
Permit Fee . . . . 20.00
Issue Date . . . . 7/18/03 Valuation . . . . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
Fee summary Charged
----------------- ----------
Permit Fee Total 20.00
Other Fee Total 45.00
Grand Total 65.00
Paid Credited Due
------------------------------
20.00 .00 .00
45.00 .00 .00
65.00 .00 .00
-------- ---- ---------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: C'-m ,n o. Q�1
Fa OTce use ony
Ar-PLICATION FOR BUILDING PERNn i
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WW W.CI.COLLEG ESTATION.TX.US
DATE
APPLICATIONX
TEMP POLE # P 5 e �`
ADDRESS/LOCATION:
LOT_ BLOCK 121 SUBDIVISION �g
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER:_PHONE:
CONTRACTOR ADDRESS:
ELECTRICIAN: PLUMBER:
HVAC: GOOD CENTS IResiden . only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK:j Er
STRUCTURE USE: AA
__1 41"m,
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (r6,% PROJECT REGISTRATION# EABPRJ
tw
VALUATION: $ oT0OTAL AREA: HEATED AREA:
( of Lab r and Materials) f�
PUBLIC SEWER NUMBER OF BEDROOMS: /
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
❑ SEWER TAP: INTERIOR WALL TYPE:,
SUE
WATER TAP: - EXTERIOR WALL TYPE: a�Sy fLer
S¢E /
OTHER TAP: FOUNDATION TYPE: ✓!
SIZE
EJ"TEMP POLE ROOF TYPE:
GARAGE TYPE: SINGLE a DOUBLE Ea- TRIPLE a
ATTACHED DETACHE CARPORT a
SIGNATURE OF APPLICANT:
Official Use O I
Co nts:
ES o NO
Plans Exam* er Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic) `-
Glazing SHGC `f
Glazing U-Factor . �n
R value of ductwork
A/C SEER rating
RESrheck Compliance Certificate
1995 MEC
REScheckSoftware Version 3.5 Release lc
Data filename: Untitled.rck
TITLE: Spec 3000X
CITY: Bryan (Brazos County)
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 07/16/03
DATE OF PLANS: 7-03
PROJECT INFORMATION:
2111 Rolling Rock Place, College Station, Tx.
COMPANY INFORMATION:
Sunset Homes
COMPLIANCE: Passes
Maximum UA = 699
Your Home UA = 545
22.0% Better Than Code (UA)
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low E
Door 1: Solid
Door 2: Glass
Door 3: Solid
Furnace 1: Forced Hot Air, 78 AFUE
Air Conditioner 1: Electric Central Air, 12 SEER
Permit Number
Checked By/Date
Gross
Glazing
Area or Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
3000 30.0
0.0
105
2630 13.0
3.2
152
408
0.670
273
18
0.150
3
12
0.390
5
18
0.390
7
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 NEC
requirements in ,eckVersio 5 Release lc (formerly IV1EC:hecli/ and to comply with the mandatory requirements listed in
the REScheckln�p�� Checkj st. )
Builder/Designer
Date
REScheck Inspection Checklist
1995 MEC
REScheckSoftware Version 3.5 Release lc
DATE: 07/16/03
TITLE: Spec 3000X
Bldg.
Dept.
Use I
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.2 continuous insulation
Comments:
Windows:
1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.670
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Solid, U-factor: 0.150
Comments:
2. Door 2: Glass, U-factor: 0.390
Comments:
3. Door 3: Solid, U-factor: 0.390
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided
Insulation R values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used
for fibrous ducts. Duct tape is not permitted
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Circulating Hot Water Systems:
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
All heated swimming pools must have an on/off heater switch and require a cover unless over 201/a
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
HVAC piping conveying fluids above 120 °F or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Wider PiPeS
Insulation Thickmess in Inches by Pipe
Sizes
Heated Water
Non -Circulating Runouts
Circulating Mains
and Runouts
Temperature ( F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressurc/ Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
CITY OF COLLEGE STATION
WOP REQUEST
PAGE
1
REQ/JOB:
WF0430384 / 001 PROJECT:
REQUEST DPRINT ATE:
7%21%03
CREW:
PRINT TIME:
13:02:34
SCHSTART.DATT/21/03
LOCATION:
2111 ROLLING ROCK PL
77845
COMPLETION:
7/21/03
GEN. LOC:
COLLEGE STATION LOC ID: 194842
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
SUNSET HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY WORK TYPE:
ROUTINE
4" SEWER
3/4" WATER
4" SEWER 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE