Loading...
HomeMy WebLinkAboutRES2003-02325PREPARED 11/25/03, 7:17:02 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/25/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 2111 ROLLING ROCK PL SUBDIV: EMERALD FOREST #11 CONTRACTOR SUNSET HOMES PHONE (979) 680-1033 OWNER EMERALD FOREST JOINT VENTURE PHONE PARCEL 249000-1120-0060 APPL NUMBER: 03-00002325 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/05/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 8/06/03 AP 08/05/2003 08:32 AM SSTANLEY SETBACKS PER STRINGS - SLAB GROUND Q RIGHT FRONT SIDE. B1 01 9/30/03 CH BLDG, FRAMING TIME: 17:00 9/30/03 AP 09/30/2003 09:25 AM SSTANLEY 10/01/2003 06:58 AM MALFORD JUST NEED TO ADD JOIST HANGERS Q ATTIC ACCESS B130 01 10/01/03 CH BLDG, INSULATION TIME: 17:00 10/01/03 AP 10/01/2003 08:32 AM MALFORD B125 01 11/25/03 D BLDG, FINAL TIME: 17:00 l((aS710 Xr OCR 11/24/2003 04:27 PM MALFORD -------------------------------------- COMMENTS AND NOTES -------------------------------- ----- rr� 2�►0✓, i S ► ns,[ Ie� CITY OF COLLEGE STATION WORK QUEST PAGE 1 REQ/JOB: WF0442662 / 001 PROJECT: DATETE:- REQUESTPRINT •8/06/03 CREW: PRINT TIME: 7:03:57 SCHSTART.DAT8/06/03 LOCATION: 2111 ROLLING ROCK PL 77845 COMPLETION: 8/06/03 GEN. LOC: COLLEGE STATION LOC ID: 194842 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: SUNSET HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE P 1101 TEXAS A COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number Property Address Property ID . . . . . . R# . . . . . . . Application description Subdivision Name . . . Property Use . . . . . Property Zoning . . . . Application valuation . . . . 03-00002325 Date 7/18/03 . . . 2111 ROLLING ROCK PL . . . 249000-1120-0060 . . . R112401 . . . RESIDENTIAL, 1 UNIT DETACHED NEW . . . EMERALD FOREST #11 . . . RESIDENTIAL . . . UNKNOWN . . . 198000 Owner Contractor ------------------------ ------------------------ EMERALD FOREST JOINT VENTURE OWNER #1 PO BOX 70 eel KURTEN TX 778620070 OV--- tn.) ��7 ------ Structure Information SINGLE FAMILY HOME ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 3000.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 259.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 754.00 Plan Check Fee .00 Issue Date . . . . 7/18/03 Valuation . . . . 198000 Expiration Date . . 1/15/04 Qty Unit Charge Per Extension BASE FEE 460.00 98.00 3.0000 THOU BLDG, VAL 100001-500000 294.00 ---------------------------------------------------------------------------- Special Notes and Comments ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE COMBUSTION AIR FOR GAS FIRED APPLI P ------------------------------------------------ ----------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: a '-a BUILDING PERMIT CITY OF COLLEGE STATIOI 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00002325 Date 7/18/03 ---------------------------------------------------------------------------- Special Notes and Comments CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT POST PERMIT CARD ON JOB SITE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total ---------- 754.00 754.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1504.00 1504.00 .00 .00 ------------------------------------------------- - --------------- - - - - - - BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATIOT" 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002326 Date 7/18/03 Property Address . . . . . . 2111 ROLLING ROCK PL Property ID 249000-1120-0060 R # . . . . . . . . R112401 Application description . . . TEMP POLE Subdivision Name . . . . . . EMERALD FOREST #11 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 0 Owner Contractor EMERALD FOREST JOINT VENTURE OWNER #1 PO BOX 70 KURTEN TX 778620070 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 7/18/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ----------------- ---------- Permit Fee Total 20.00 Other Fee Total 45.00 Grand Total 65.00 Paid Credited Due ------------------------------ 20.00 .00 .00 45.00 .00 .00 65.00 .00 .00 -------- ---- --------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: C'-m ,n o. Q�1 Fa OTce use ony Ar-PLICATION FOR BUILDING PERNn i CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WW W.CI.COLLEG ESTATION.TX.US DATE APPLICATIONX TEMP POLE # P 5 e �` ADDRESS/LOCATION: LOT_ BLOCK 121 SUBDIVISION �g BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER:_PHONE: CONTRACTOR ADDRESS: ELECTRICIAN: PLUMBER: HVAC: GOOD CENTS IResiden . only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK:j Er STRUCTURE USE: AA __1 41"m, HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (r6,% PROJECT REGISTRATION# EABPRJ tw VALUATION: $ oT0OTAL AREA: HEATED AREA: ( of Lab r and Materials) f� PUBLIC SEWER NUMBER OF BEDROOMS: / SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: ❑ SEWER TAP: INTERIOR WALL TYPE:, SUE WATER TAP: - EXTERIOR WALL TYPE: a�Sy fLer S¢E / OTHER TAP: FOUNDATION TYPE: ✓! SIZE EJ"TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE a DOUBLE Ea- TRIPLE a ATTACHED DETACHE CARPORT a SIGNATURE OF APPLICANT: Official Use O I Co nts: ES o NO Plans Exam* er Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) `- Glazing SHGC `f Glazing U-Factor . �n R value of ductwork A/C SEER rating RESrheck Compliance Certificate 1995 MEC REScheckSoftware Version 3.5 Release lc Data filename: Untitled.rck TITLE: Spec 3000X CITY: Bryan (Brazos County) STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/16/03 DATE OF PLANS: 7-03 PROJECT INFORMATION: 2111 Rolling Rock Place, College Station, Tx. COMPANY INFORMATION: Sunset Homes COMPLIANCE: Passes Maximum UA = 699 Your Home UA = 545 22.0% Better Than Code (UA) Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low E Door 1: Solid Door 2: Glass Door 3: Solid Furnace 1: Forced Hot Air, 78 AFUE Air Conditioner 1: Electric Central Air, 12 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 3000 30.0 0.0 105 2630 13.0 3.2 152 408 0.670 273 18 0.150 3 12 0.390 5 18 0.390 7 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 NEC requirements in ,eckVersio 5 Release lc (formerly IV1EC:hecli/ and to comply with the mandatory requirements listed in the REScheckln�p�� Checkj st. ) Builder/Designer Date REScheck Inspection Checklist 1995 MEC REScheckSoftware Version 3.5 Release lc DATE: 07/16/03 TITLE: Spec 3000X Bldg. Dept. Use I Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.2 continuous insulation Comments: Windows: 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.150 Comments: 2. Door 2: Glass, U-factor: 0.390 Comments: 3. Door 3: Solid, U-factor: 0.390 Comments: Heating and Cooling Equipment: 1. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided Insulation R values, glazing U-factors, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used for fibrous ducts. Duct tape is not permitted The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 201/a of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: HVAC piping conveying fluids above 120 °F or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Wider PiPeS Insulation Thickmess in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressurc/ Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) CITY OF COLLEGE STATION WOP REQUEST PAGE 1 REQ/JOB: WF0430384 / 001 PROJECT: REQUEST DPRINT ATE: 7%21%03 CREW: PRINT TIME: 13:02:34 SCHSTART.DATT/21/03 LOCATION: 2111 ROLLING ROCK PL 77845 COMPLETION: 7/21/03 GEN. LOC: COLLEGE STATION LOC ID: 194842 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: SUNSET HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" SEWER 3/4" WATER 4" SEWER 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE