HomeMy WebLinkAboutRES2003-02323PREPARED
10/31/03,
7:32:56
INSPECTION TICKET PAGE 12
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 10/31/03
------------------------------------------------------------------------------------------------
ADDRESS
. : 2109 ROLLING
ROCK
PL SUBDIV: EMERALD FOREST #11
CONTRACTOR SUNSET
HOMES
PHONE (979) 680-1033
OWNER
EMERALD
FOREST JOINT VENTURE PHONE
PARCEL
249000-1120-0050
APPL NUMBER: 03-00002323
------------------------------------------------------------------------------------------------
RESIDENTIAL, 1 UNIT DETACHED NEW
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED
INSP
DESCRIPTION
TYP/SQ
COMPLETED
RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
8/04/03
OC
BLDG, FOUNDATION -SLAB TIME: 17:00
8/04/03
AP
08/04/2003 08:12 AM MALFORD
THIS AFTERNOON PLEASE
setbacks per strings
slab ground @ right back
B115 01
9/02/03
CH
BLDG, FRAMING TIME: 17:00
9/02/03
AP
09/02/2003 08:46 AM SSTANLEY
09/03/2003 07:18 AM MALFORD
fireblock above areches and fireplace
max. window sill height 44" in bedroom
B130 01
9/05/03
OC
BLDG, INSULATION TIME: 17:00
9/08/03
AP
09/05/2003 08:14 AM SSTANLEY
B125 01
10/31/03
BI
BLDG, FINAL TIME: 17:00
fI>/31(03
4? OL
10/30/2003 03:10 PM MALFORD
------------------------- COMMENTS AND NOTES---------------------------------------------------
r
%-,3 -3?1
CITY OF COLLEGE STATION
WORK 7QUEST PAGE 1
REQ/JOB: WF0431134 / U01 PROJECT: REQUEST
DATE: 7/2PRINT 2/03
CREW: PRINT TIME: 11:30:47
LOCATION: 2109 ROLLING ROCK PL SCHEDULE
START:DATE/22/03
77845 COMPLETION: 7f22/03
GEN. LOC: COLLEGE STATION LOC ID: 194840
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: SUNSET HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
' W-1 10*1
WTEWAV
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00002323 Date 7/18/03
Property Address . . . . . . 2109 ROLLING ROCK PL
Property ID . . 249000-1120-0050
R # . . . . . . . . . . . . . R112400
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . EMERALD FOREST #11
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . UNKNOWN
Application valuation . . . . 176550
Owner Contractor
--------------------
EMERALD FOREST JOINT VENTURE OWNER oC ' AAomQ-
#1
PO BOX 70
KURTEN TX 778620070 V
------ Structure Information SINGLE FAMILY HOME -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2675.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 259.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . SS
Permit Fee . . . . 691.00 Plan Check Fee .00
Issue Date . . . . 7/18/03 Valuation . . . . 176550
Expiration Date . . 1/15/04
Qty Unit Charge Per Extension
BASE FEE 460.00
77.00 3.0000 THOU BLDG, VAL 100001-500000 231.00
----------------------------------------------------------------------------
Special Notes and Comments
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
-
--------------- ----- -------------------------------- ---------------
BUILDING DEPT DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CXTY.OF COLLEGE STATIOT
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page
2
Application Number . . . . . 03-00002323 Date
7/18/03
----------------------------------------------------------------------------
Special Notes and Comments
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT
POST PERMIT CARD ON JOB SITE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
Larger windows in BR #2 and dining room may have to be
tempered glass due to size if bottom is less that 18" AFF
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 691.00 691.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1441.00 1441.00 .00
.00
--------------------------------------------------- -7- - --------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATIOD
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . .
Property Address . . . . .
Property ID
R# . . . . . . .
Application description .
Subdivision Name . . . . .
Property Use . . . . . . .
Property Zoning . . . . . .
Application valuation . . .
03-00002324
2109 ROLLING ROCK PL
249000-1120-0050
R112400
TEMP POLE
EMERALD FOREST #11
RESIDENTIAL
UNKNOWN
0
Owner Contractor
EMERALD FOREST JOINT VENTURE OWNER
#1
PO BOX 70
KURTEN TX 778620070
Date 7/18/03
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . SS
Permit Fee . . . . 20.00
Issue Date . . . . 7/18/03 Valuation . . . . 0
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 20.00 20.00 .00 .00
Grand Total 20.00 20.00 .00 .00
---------------------------------------------------- - L --------------------------
BUILDING DEPT REPRESENTATIVE: _:;-?L
APPLICANT:
CITY OF COLLEGE STATION
WOR EQUEST
PAGE
1
REQ/JOB:
WF0430368 / 001 PROJECT:
REQUEST DATE:
7/21/03
PRINT DATE:
7/21/03
CREW:
PRINT TIME:
12:53:34
SCHSTART.DATE/21/03
DULLOCATION:
2109 ROLLING ROCK PL
77845
COMPLETION:
7/21/03
GEN. LOC:
COLLEGE STATION LOC ID: 194840
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
SUNSET HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY WORK TYPE:
ROUTINE
4" SEWER
3/4" WATER
4" SEWER
3/4" WATER
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID
Assigned Department:
OT-CUSTOMER SERVICE
Af-PLICATION FOR BUILDING PERMS
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG ESTATION.TX.US
ADDRESS/LOCATION: KA///Av/_ !IAAK
far Office Use Only
DATE:
TEMP POLE # V , 3
LOT BLOCK SUBDIVISIONdF
'FjT/��P�
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: �/y/�� PHONE:
CONTRACTOR ADDRESS:
ELECTRICIAN:
HVAC:
GOOD CENTS
CLASS OF WORK
only): iS/i� 1�
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATI i SWIMMINGPOOL
DESCRIPTION OF WORK: /
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARn (TAm PROJECT �f�GISTRATION# EABPRJ
VALUATION: $ 1l �_ A�I(p��7"1"OTAL AREA.-5� HEATED AREA:
(C91ffL5b6r dndMaterials)
dPUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
SEWER TAP:
SUE
1dWATER TAP: 3 ��
OTHER TAP:
TEMP POLE
GARAGE TYPE:
SUE
SINGLE
ATTACHED
SIGNATURE OF APPLICANT:
Plans Examiner
NUMBER OF BEDROOMS: 4
NUMBER OF BATHROOMS:
s
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
Energy Code Compliance Information
% Glazing of exterior walls leto
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor , �o 7
R value of ductwork
A/C SEER rating 12
M
REScheck Compliance Certificate
1995 MEC
REScheckSoftware Version 3.5 Release lc
Data filename: Untitledrek
TITLE: 2675
CITY: Bryan (Brazos County)
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 07/16/03
DATE OF PLANS: 7-03
PROJECT INFORMATION:
2109 Rolling Rock Place, College Station, Tx.
COMPANY INFORMATION:
Sunset Homes
COMPLIANCE: Passes
Maximum UA = 631
Your Home UA = 507
19.7% Better Than Code (UA)
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low E
Door 1: Solid
Door 2: Glass
Door 3: Solid
Furnace 1: Forced Hot Air, 78 AFUE
Air Conditioner 1: Electric Central Air, 12 SEER
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U Factor UA
2675 30.0 0.0
94
2374 13.0 3.2
135
392
0.670
263
18
0.150
3
12
0.390
5
18
0.390
7
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations sMEubmitted with the permit application. The proposed building has been designed to meet the 1995 MEC
requirements inckVersion 3.5 Release lc (formerly Cchec4 and to comply with the mandatory requirements listed in
the REScheckIt ES ohCheckh . )
Builder/Designer
Date
REScheck Inspection Checklist
1995 MEC
REScheckSofiware Version 3.5 Release lc
DATE: 07/16/03
TITLE: 2675
Bldg.
Dept.
Use
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.2 continuous insulation
Comments:
Windows:
1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.670
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Solid, U-factor: 0.150
Comments:
2. Door 2: Glass, U-factor: 0.390
Comments:
3. Door 3: Solid, U-factor: 0.390
Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
L I I All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used
for fibrous ducts. Duct tape is not permitted.
[ ] I The 1 VAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to
I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided
I
Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Swimini. g Pools:
[ ] I All heated swimming pools must have an onloff heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating and Cooling Piping Insulation:
[ ] I HVAC piping conveying fluids above 120 OF or chilled fluids below 55 IF must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe
Sizes
Heated Water
Non -Circulating Runouts
Circulating Mains
and Runouts
Temperature ( F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range ( F)
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressurc) Temperatum
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)