Loading...
HomeMy WebLinkAboutRES2003-02323PREPARED 10/31/03, 7:32:56 INSPECTION TICKET PAGE 12 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/31/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 2109 ROLLING ROCK PL SUBDIV: EMERALD FOREST #11 CONTRACTOR SUNSET HOMES PHONE (979) 680-1033 OWNER EMERALD FOREST JOINT VENTURE PHONE PARCEL 249000-1120-0050 APPL NUMBER: 03-00002323 ------------------------------------------------------------------------------------------------ RESIDENTIAL, 1 UNIT DETACHED NEW PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/04/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 8/04/03 AP 08/04/2003 08:12 AM MALFORD THIS AFTERNOON PLEASE setbacks per strings slab ground @ right back B115 01 9/02/03 CH BLDG, FRAMING TIME: 17:00 9/02/03 AP 09/02/2003 08:46 AM SSTANLEY 09/03/2003 07:18 AM MALFORD fireblock above areches and fireplace max. window sill height 44" in bedroom B130 01 9/05/03 OC BLDG, INSULATION TIME: 17:00 9/08/03 AP 09/05/2003 08:14 AM SSTANLEY B125 01 10/31/03 BI BLDG, FINAL TIME: 17:00 fI>/31(03 4? OL 10/30/2003 03:10 PM MALFORD ------------------------- COMMENTS AND NOTES--------------------------------------------------- r %-,3 -3?1 CITY OF COLLEGE STATION WORK 7QUEST PAGE 1 REQ/JOB: WF0431134 / U01 PROJECT: REQUEST DATE: 7/2PRINT 2/03 CREW: PRINT TIME: 11:30:47 LOCATION: 2109 ROLLING ROCK PL SCHEDULE START:DATE/22/03 77845 COMPLETION: 7f22/03 GEN. LOC: COLLEGE STATION LOC ID: 194840 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: SUNSET HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE ' W-1 10*1 WTEWAV COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002323 Date 7/18/03 Property Address . . . . . . 2109 ROLLING ROCK PL Property ID . . 249000-1120-0050 R # . . . . . . . . . . . . . R112400 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EMERALD FOREST #11 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 176550 Owner Contractor -------------------- EMERALD FOREST JOINT VENTURE OWNER oC ' AAomQ- #1 PO BOX 70 KURTEN TX 778620070 V ------ Structure Information SINGLE FAMILY HOME ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2675.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 259.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 691.00 Plan Check Fee .00 Issue Date . . . . 7/18/03 Valuation . . . . 176550 Expiration Date . . 1/15/04 Qty Unit Charge Per Extension BASE FEE 460.00 77.00 3.0000 THOU BLDG, VAL 100001-500000 231.00 ---------------------------------------------------------------------------- Special Notes and Comments ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER - --------------- ----- -------------------------------- --------------- BUILDING DEPT DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CXTY.OF COLLEGE STATIOT 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00002323 Date 7/18/03 ---------------------------------------------------------------------------- Special Notes and Comments CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT POST PERMIT CARD ON JOB SITE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. Larger windows in BR #2 and dining room may have to be tempered glass due to size if bottom is less that 18" AFF ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due ------------------------------ --------------------------- Permit Fee Total 691.00 691.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1441.00 1441.00 .00 .00 --------------------------------------------------- -7- - -------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATIOD 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . Property Address . . . . . Property ID R# . . . . . . . Application description . Subdivision Name . . . . . Property Use . . . . . . . Property Zoning . . . . . . Application valuation . . . 03-00002324 2109 ROLLING ROCK PL 249000-1120-0050 R112400 TEMP POLE EMERALD FOREST #11 RESIDENTIAL UNKNOWN 0 Owner Contractor EMERALD FOREST JOINT VENTURE OWNER #1 PO BOX 70 KURTEN TX 778620070 Date 7/18/03 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 7/18/03 Valuation . . . . 0 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 20.00 20.00 .00 .00 Grand Total 20.00 20.00 .00 .00 ---------------------------------------------------- - L -------------------------- BUILDING DEPT REPRESENTATIVE: _:;-?L APPLICANT: CITY OF COLLEGE STATION WOR EQUEST PAGE 1 REQ/JOB: WF0430368 / 001 PROJECT: REQUEST DATE: 7/21/03 PRINT DATE: 7/21/03 CREW: PRINT TIME: 12:53:34 SCHSTART.DATE/21/03 DULLOCATION: 2109 ROLLING ROCK PL 77845 COMPLETION: 7/21/03 GEN. LOC: COLLEGE STATION LOC ID: 194840 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: SUNSET HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" SEWER 3/4" WATER 4" SEWER 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE Af-PLICATION FOR BUILDING PERMS CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG ESTATION.TX.US ADDRESS/LOCATION: KA///Av/_ !IAAK far Office Use Only DATE: TEMP POLE # V , 3 LOT BLOCK SUBDIVISIONdF 'FjT/��P� BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: �/y/�� PHONE: CONTRACTOR ADDRESS: ELECTRICIAN: HVAC: GOOD CENTS CLASS OF WORK only): iS/i� 1� ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATI i SWIMMINGPOOL DESCRIPTION OF WORK: / STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARn (TAm PROJECT �f�GISTRATION# EABPRJ VALUATION: $ 1l �_ A�I(p��7"1"OTAL AREA.-5� HEATED AREA: (C91ffL5b6r dndMaterials) dPUBLIC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: SUE 1dWATER TAP: 3 �� OTHER TAP: TEMP POLE GARAGE TYPE: SUE SINGLE ATTACHED SIGNATURE OF APPLICANT: Plans Examiner NUMBER OF BEDROOMS: 4 NUMBER OF BATHROOMS: s INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: Energy Code Compliance Information % Glazing of exterior walls leto Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor , �o 7 R value of ductwork A/C SEER rating 12 M REScheck Compliance Certificate 1995 MEC REScheckSoftware Version 3.5 Release lc Data filename: Untitledrek TITLE: 2675 CITY: Bryan (Brazos County) STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/16/03 DATE OF PLANS: 7-03 PROJECT INFORMATION: 2109 Rolling Rock Place, College Station, Tx. COMPANY INFORMATION: Sunset Homes COMPLIANCE: Passes Maximum UA = 631 Your Home UA = 507 19.7% Better Than Code (UA) Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low E Door 1: Solid Door 2: Glass Door 3: Solid Furnace 1: Forced Hot Air, 78 AFUE Air Conditioner 1: Electric Central Air, 12 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U Factor UA 2675 30.0 0.0 94 2374 13.0 3.2 135 392 0.670 263 18 0.150 3 12 0.390 5 18 0.390 7 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations sMEubmitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements inckVersion 3.5 Release lc (formerly Cchec4 and to comply with the mandatory requirements listed in the REScheckIt ES ohCheckh . ) Builder/Designer Date REScheck Inspection Checklist 1995 MEC REScheckSofiware Version 3.5 Release lc DATE: 07/16/03 TITLE: 2675 Bldg. Dept. Use Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity + R-3.2 continuous insulation Comments: Windows: 1. Window 1: Metal Frame:Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.150 Comments: 2. Door 2: Glass, U-factor: 0.390 Comments: 3. Door 3: Solid, U-factor: 0.390 Comments: Heating and Cooling Equipment: 1. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: L I I All ducts must be sealed with mastic and fibrous backing tape. Pressure -sensitive tape may be used for fibrous ducts. Duct tape is not permitted. [ ] I The 1 VAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimini. g Pools: [ ] I All heated swimming pools must have an onloff heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 120 OF or chilled fluids below 55 IF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressurc) Temperatum 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)