HomeMy WebLinkAboutRES2003-02322PREPARED 10/16/03, 12:03:13 INSPECTION TICKET PAGE 16 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/16/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 1304 ROANOKE CT SUBDIV: SHENANDOAH PH 7 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER ED FROEHLING BUILDER INC PHONE PARCEL 569500-0727-0630 APPL NUMBER: 03-00002322 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------- PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/19/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 8/19/03 AP 08/18/2003 03:08 PM KELMENDORF 9:00 am if possible setback strings pulled B115 01 9/17/03 CH BLDG, FRAMING TIME: 17:00 9/17/03 AP 09/16/2003 04:03 PM GCARRILLO 09/17/2003 10:52 AM MALFORD DOUBLE JOISTS IN GARAGE WHERE HEADERED OFF , NEED DOUBLE STUDS JOISTS IN FRONT LEFT BEDROOM B130 01 9/18/03 CH BLDG, INSULATION TIME: 17:00 9/18/03 AP 09/17/2003 02:27 PM MALFORD B125 01 10/16/03 BI BLDG, FINAL TIME: 17:00 at 10/16/2003 10:57 AM MALFORDDL-) 10 ----------------------------�- CONTINUED ONTO NEXT PAGE ---------------------------- ------ City of College Station WORK ]QUEST PAGE 1 REQ/JOB: WF0456184 / 001 • .. PROJECT REQUEST DATE: 8/26/03 PRINT DATE: 8/26/03 CREW: PRINT TIME: 16:31:53 SCHEDULE DATES LOCATION: 1304 ROANOKE CT START: 8/26/03 77845 COMPLETION: 8/26/03 GEN. LOC: COLLEGE STATION LOC ID: 195180 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ed froehling builders ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE temp pole passed temp pole passed Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE BUILDING PERMIT CITY' _ =' '--'STA"T IWIM 01 Now .. COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002322 Date 7/21/03 Property Address . . . . . . 1304 ROANOKE CT Property ID 569500-0727-0630 R # . . . . . . R112787 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SHENANDOAH PH 7 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 100386 Owner Contractor ------------------------ ------------------------ ED FROEHLING BUILDER INC ED FROEHLING BUILDERS 3887 HIGH LONESOME ED FROEHLING COLLEGE STATION TX 778459443 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 ------ Structure Information SINGLE FAMILY RESIDENCE ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1521.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 463.00 Plan Check Fee .00 Issue Date . . . . 7/21/03 Valuation . . . . 100386 Expiration Date . . 1/18/04 Qty Unit Charge Per Extension BASE FEE 460.00 1.00 3.0000 THOU BLDG, VAL 100001-500000 3.00 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR BUILDING DEP1T ESENTATIVE: I A.. k APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIOT fTO1 TEXAS AVE ' COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00002322 Date 7/21/03 ---------------------------------------------------------------------------- Special Notes and Comments TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT POST PERMIT CARD ON JOB SITE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 463.00 463.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1213.00 1213.00 .00 .00 BUILDING D EPT REPRESENTATIVE: APPLICANT: CITY OF COLLEGE STATION WOR" '.EQUEST PAGE 1 REQ/JOB: WF0430737 / 001 PROJECT: REQUEST DATE: 7/21/03 PRINT DATE: 7/21/03 CREW: PRINT TIME: 16:37:28 SCHEDULE LOCATION: 1304 ROANOKE CT START:DAT7/21/03 77845 COMPLETION: 7/21/03 GEN. LOC: COLLEGE STATION LOC ID: 195180 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING BUILDER ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" SEWER 3/4" WATER 4" SEWER 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE For Office Uw OWy APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US DATE: .SvL. Y S ZOO APPLICATION # ©�� TEMP POLE # ADDRESS/LOCATION: 13 04 (LOA A1 o14 (-,': 0004--r LOT 63 BLOCK Z 7 SUBDIVISION 5 40,a 4.41 D04if SEC/PH 7. L3 BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: p MO O M L /.urn f301&yD60-. PHONE: % 76 • fZi!�C CONTRACTOR ADDRESS: 3 $ $ % If [ Lg lj L O,V£Sa11 e 2 0 ELECTRICIAN: PLUMBER: 7 IP1, E S ' PLV17131, 4 HVAC: (�M J.v.uD VA.7/ VE Sf.21/it,or !� GOOD CENTS (Residential only): CLASS OF ACCESSORY/STORAGE LOCAT ON ADDITION MOVIN DEMOLITION (Asbestos Survey) NEW O t DUPLEX (Landscape Plans REMO Req) DESCRIPTION OF WORK: STRUCTURE USE: 61, HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ /U 1A VALUATION: $ 100384 TOTAL AREA: Zo4?— HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM KSEWER TAP: ® WATER TAP: ❑ OTHER TAP: 4 lr IZE 3 ��I SIZE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: 3 8XIC1IL JIZE TEMP POLE ROOF TYPE: GOnPoS/>/o.✓ SiiJ�GL GARAGE TYPE: SINGLE a DOUBLE Fe] TRIPLE ATTACHED' DETACHED F--] CARPORT SIGNATURE OF APPLICANT: Plans Examiner Official Use Only Comments: Zoning Off WAND MUNsT L FEES DUE av Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating 2- 30 .40 ,6a --6 .12 $6 Permit Number REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\1304RK.rck TITLE: 1304 ROANOKE COURT CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/15/03 DATE OF PLANS: JULY 14, 2003 PROJECT INFORMATION: PALMER HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 576 Your Home UA = 500 13.2% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1521 30.0 0.0 53 Wall 1: Wood Frame, 16" o.c. 396 13.0 0.0 24 Window 1: Metal Frame:Double Pane with Low-E 63 0.600 38 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Front Projection factor: 0.19 Door 1: Solid 38 0.400 15 Wall 2: Wood Frame, 16" o.c. 374 13.0 0.0 30 Window 2: Metal Frame:Double Pane with Low-E 6 0.600 4 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Left Side Projection factor: 0.43 Wall 3: Wood Frame, 16" o.c. 396 13.0 0.0 22 Window 3: Metal Frame:Double Pane with Low-E 115 0.600 69 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.23 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame, 16" o.c. 374 13.0 0.0 30 Window 4: Metal Frame:Double Pane with Low-E 6 0.600 4 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Left Side Projection factor: 0.43 Floor 1: Slab-On-Grade:Unheated 193 0.0 201 Insulation depth: 0.0' COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lb (formerly MECchec)� and to comply with the mandatory requirements listed in the RES check Inspection Checklist. Builder/Designer k�� )4.ePQ.p,L_ Date O _r 1149,;fS *j MOUlurw 979 693-2S54 P.4 ROMOke Covrt so' ,ear: - 27' PROW110 iW. 4971, P# 157 @a" r :Qro' JV 4 52W'JV' £ - B.% W' S' P U.E. �. —4 -- •-- -. _ ..._ - ___. _ __.._._ L, N ;q P4 +wr i t I M � I ScoW 1 • Zp• p�a� W I N� 1/ O+ �vYl11M;f I %w or Fem woy Gwn1 irwr' [mad F•Mh�y VOL wi. 2 h i 7.5' i Zoe dU Aftd* SJhw►+onoi�oih P14�OMr 7—B l�A�(Gc.P` -- NM t i w at»°. 4 'lmin� Ar�in.na ►T� V- M� U - I" � 14° P,V.E. Vol. 4054, Pp. 135 - f ;04 ov' R. ap. ►• JI' Povo rt NcCt 1/REEtiGJNEEA�vG, INC • .twig 10.7 • Ca&70 SAFAM AMOS 17"5 • A91W W -W-V