HomeMy WebLinkAboutRES2003-02309PREPARED 12/16/03, 12:09:46 INSPECTION TICKET PAGE 11
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/16/03
------------------------------------------------------------------------------------------------
ADDRESS . : 4214 DROGO CT SUBDIV: CASTLEGATE SEC 10 & 13
CONTRACTOR BENCHMARK HOMES PHONE (979) 690-7117
OWNER GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL 184200-0102-0520
APPL NUMBER: 03-00002309 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 7/23/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00
7/24/03 AP 07/23/2003 11:32 AM KELMENDORF
last thing if possible
SLAB GROUND BACK LEFT SIDE. STRINGS ON SETBACKS, OK.
B115 01 8/27/03 TB BLDG, FRAMING TIME: 17:00
8/28/03 AP 08/27/2003 08:12 AM MALFORD
B125 01 12/16/03 BLDG, FINAL TIME: 17:00
L�(r. 12/16/2003 09:40 AM MALFORD
-------------------------------------- COMMENTS AND NOTES--------------------------------------
4'LA-w,j r &4A'5 � � � y s'4e,- rA/,PA l(,W
Mandi Alford - Insulation request insper result, 4214 Drogo, #03-2309 Page 1
From: Brian Henry
To: Elmendorf, Katy
Date: 8/28/03 3:57PM
Subject: Insulation request inspection result, 4214 Drogo, #03-2309
Print for File
Inspected insulation, 4214 Drogo, #03-2309 Benchmark Homes, 8-28-03
Inspection result: Inspected OK for Good Cents
Notes:
Duct out bath exhaust fans
CC: Alford, Mandi
CITY OF COLLEGE STATION
WORK ,,QUEST
PAGE
1
REQ/JOB:
WF0433539 / 001 PROJECT:
DATE
REQUESTPRINT
7%25%03
CREW:
PRINT TIME:
12:14:52
SCHSTARRT.DAT7/25/03
DULELOCATION:
4214 DROGO CT
77845 COMPLETION:
7/25/03
GEN. LOC:
COLLEGE STATION LOC
ID: 197942
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
BENCHMARK HOMES
ORIGIN: CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY
WORK TYPE: ROUTINE
TEMP POLE
PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
BUILDING PERMIT
' T
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00002309
Date 7/16/03
Property Address . .
. . . . 4214 DROGO CT
Property ID
. . 184200-1002-0520
R# . . . . . . . . .
. . . . R*****
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . CASTLEGATE SEC 10
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . PLANNED DEVL HOUSING
Application valuation
. . . . 106128
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD BENCHMARK HOMES
4490 CASTLEGATE DR
GLENN THOMAS
COLLEGE STATION
TX 778453388 1110 12TH MAN COURT
COLLEGE STATION
TX 77845
(979) 690-7117
------ Structure Information
SINGLE FAMILY HOME
-----
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1608.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
SERIAL ZONES
249.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
SAS
Permit Fee . . . .
481.00 Plan Check Fee
.00
Issue Date . . . .
7/16/03 Valuation . .
. . 106128
Expiration Date . .
1/13/04
Qty Unit Charge
Per
Extension
BASE FEE
460.00
7.00 3.0000
THOU BLDG, VAL 100001-500000
21.00
----------------------------------------------------------------------------
Special Notes and Comments
ADD SMOKE DETECTOR(S)
PER NOTES ON PLANS
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE COMBUSTION AIR
FOR GAS FIRED APPLIANCES PER
BUILDING DEPT PRESENTAW
APPLICANT:
BUILDING PERMIT
CITY_OF COLLEGE STATIOI
101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
2
Application Number . . . . .
03-00002309 Date
7/16/03
----------------------------------------------------------------------------
Special Notes and Comments
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ALL FRAMING SHALL COMPLY WITH
2O00 INTERNATIONAL RESIDENTIAL
CODE
IF LAWN SPRINKLER IS PROVIDED,
PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
REQUIRED EXIT DOORS SHALL BE
OPENABLE FROM THE INSIDE
WITHOUT THE USE OF A KEY,TOOL
OR SPECIAL KNOWLEDGE/EFFORT
POST PERMIT CARD ON JOB SITE
PROVIDE FIRE EXTINGUISHER(S)
- VERIFY LOCATION AND PLACEMENT
WITH THE FIRE MARSHALL'S
OFFICE (MIN. 2A10BC)
PROVIDE STRING LINES FOR ALL
BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION
INSPECTION.
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4" CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged
Paid Credited Due
------------------------------
---------------------------
Permit Fee Total 481.00
481.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1231.00
1231.00 .00
.00
--------------------------------------------------7,-
---------------------
BUILDING DEPT REPEWENTATIVE p
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATIO?
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
03-00002310 Date
7/16/03
Property Address . . . . . .
4214 DROGO CT
Property ID . .
184200-1002-0520
R # . . . . . . . . . . . . .
R*****
Application description . . .
TEMP POLE
Subdivision Name . . . . . .
CASTLEGATE SEC 10
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
PLANNED DEVL HOUSING
Application valuation . . . .
0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
BENCHMARK HOMES
4490 CASTLEGATE DR
GLENN THOMAS
COLLEGE STATION TX 778453388
1110 12TH MAN COURT
COLLEGE STATION
TX 77845
(979) 690-7117
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . SAS
Permit Fee . . . . 20.00
Issue Date . . . . 7/16/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
Paid Credited
--------------------
Due
---------------------------
Permit Fee Total 20.00
----------
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
BUILDING DEPT REESENTATIVF6.�
APPLICANT:
�----1 - ''PLICATION FOR BUILDING PE— ` 11T DATE*
.Y OF COLLEGE STATION APP"7M 0
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE # D 3 3 D
(979) 764-3570 (979) 764-3496 FAX
W W W.CLCOLLEGE4TATION.TX.US
ADDRESS/LOCATION: .4Z-14 e-n r, n t
LOT BLOCK SUBDIVISION
BUSINESS/OWNER NAME: MIA 11o"k � PHONE:
CONTRACTOR/HOMEOWNER: PHONE: 41Z !U'%1 C.5-1
CONTRACTOR ADDRESS: -WO QAA5i1l ( 1
ELECTRICIAN: _ L-7, 16 to u PLUMBER:
HVAC: F GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE: - te) i
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL.
TEXAS ACCESSIBILITY STANDARD (T-AS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 1 , r' /0 b,rTOTAL AREA: HEATED AREA:
(CffZ
st of LaW and Matte)
►�1
❑ SEPTIC/TREATMENT SYSTEM
SEWER TAP: I I
SME
�] WATER TAP: 3 I I
SIZE
❑ OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE:
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
ExTERioR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
SINGLE ❑ DOUBLE � TRIPLE
ATTACHED E�Q rNgETACHED �D �ARAOR
SIGNATURE OF APPLICANT:
Plans Examiner
O>flder use Only
ts:
YES NO
Zoning Offidai
I dq
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
1301
v
Permit Number
MECcheck Compliance Report Checked By/Date
2000 IECC
MECcheckSoftware Version 3.4 Release la
Data filename: C:\Program Files\Check\IM ECcheck\MecCheck Docs\246BM.cck
TITLE: Benchmark Homes Job 246
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 07/14/03
DATE OF PLANS: July 15,2003
PROJECT INFORMATION:
Benchmark Homes
Job 246
Lot 52 Block 2 Castlegate 10
College Station, Tx 77845
COMPANY INFORMATION:
Benchmark Homes
1110 12th Man Court
College Station, TX 77845
NOTES:
1608-A (Like 4210 Conway Court)
COMPLIANCE: Passes
Maximum UA = 447
Your Home = 315
29.5% Better Than Code
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
Ceiling 1: Flat Ceiling or Scissor Truss
1608
30.0
0.0
56
Wall 1: Wood Frame, 16" o.c.
1701
13.0
0.0
120
Window l: Metal Frame:Double Pane with Low-E
162
0.570
92
Door 1: Solid
20
0.630
13
Door 2: Glass
54
0.630
34
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 12 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in MECcheckVersion 3.4 Release la and to comply with the mandatory requirements listed in the MEC check
Inspection Checklist. I—fi \�,
Builder/Designer A Q A �►,1 Date 1— I `7�3
A , 1 .
MECcheck Inspection Checklist
2000 IECC
MECcheckSoftware Version 3.4 Release la
DATE: 07/14/03
TITLE: Benchmark Homes Job 246
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
I Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Doors:
[ ] 1. Door 1: Solid, U-factor: 0.630
1 Comments:
Heating and Cooling Equipment:
1. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
2. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe
Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to i„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2.- Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Jul 16 03 02339p G- n Thomas 979,-07118 p.l
-59. ze"O,"
b 24 �� 4. COO&?4
4 tick" (k NVIA-cs
'SL a 4
CITY OF COLLEGE STATION
WOR. ]QUEST
PAGE
1
REQ/JOB:
WF0428800 / 001 PROJECT:
REQUEST DATE:
7/17/03
PRINT DATE:
7/17/03
CREW:
PRINT TIME:
8:48:04
DULLOCATION:
SCHSTARE•DAT7/17/03
4214 DROGO CT
77845
COMPLETION:
7/17/03
GEN. LOC:
COLLEGE STATION LOC ID: 197942
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
BENCHMARK HOMES (690-7117) ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSMITH AUTH: SSMITH WORK TYPE:
ROUTINE
4" SEWER;
3/4" WATER
4" SEWER; 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .