Loading...
HomeMy WebLinkAboutRES2003-02256PREPARED 9/04/03, 10:29:37 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/04/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 900 BOUGAINVILLEA ST SUBDIV: SUN MEADOWS PH 2 CONTRACTOR K M CUSTOM HOMES PHONE (979) 589-3739 OWNER GRAHAM ROAD LTD PHONE PARCEL 589700-0207-0010 APPL NUMBER: 03-00002256 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 02 7/24/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 7/25/03 CA 07/24/2003 04:44 PM KELMENDORF afternoon between 4 and 5 r NOT READY FOR INSPECTION BI t.1'01 7/24/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 7/24/03 DP 07/24/2003 11:17 AM KELMENDORF between 4 ans 5 if possible was not ready B160 03 8/06/03 LS BLDG, FOUNDATION -SLAB TIME: 17:00 8/06/03 AP 08/06/2003 08:38 AM KELMENDORF B1t5 01 8/06/03 DS BLDG, FRAMING TIME: 17:00 8/07/03 DP 08/06/2003 10:28 AM KELMENDORF r. PERLIN BRACES NEED TO BE UNDER 2X6. ANCHOR NUTS LOOSE n THROUGH OUT HOUSE. JOIST HANGERS RETURN AIR. FIX HOLES IN ENERGY BOARD. B115 02 8/07/03 CH BLDG, FRAMING TIME: 17:00 8/07/03 DP 08/07/2003 11:32 AM MALFORD did not get okay to insulate cannot see energy board B3*- 03 9/04/03 LS BLDG, FRAMING TIME: 17:00 9/04/03 AP 09/04/2003 10:27 AM SSTANLEY SEE LANCE B125 01 9/,0 03 BB BLDG, FINAL TIME: 17:00 09/04/2003 10:29 AM SSTANLEY 0-------------'1------- f } ------------- - COMMENTS AND NOTES 4 UILDIERMIT - CITY 0 CO E S17TTT' V �. 117'1 T S AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002256 Date 7/17/03 Property Address . . . . . . 900 BOUGAINVILLEA ST Property ID 589700-0207-0010 R # . . . . . . R11174 9 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . SUN MEADOWS PH 2 Property Use . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 110000 Owner Contractor ------------------------ GRAHAM ROAD LTD ------------------------ K M CUSTOM HOMES 2508 RIVER FOREST DR KENNY MELESKY BRYAN TX 778022827 8778 OLD RELIANCE RD BRYAN TX 77808 (979) 589-3739 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1471.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 245.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 490.00 Plan Check Fee .00 Issue Date . . . . 7/17/03 Valuation . . . . 110000 Expiration Date . . 1/14/04 Qty Unit Charge Per Extension BASE FEE 460.00 10.00 3.0000 THOU BLDG, VAL 100001-500000 30.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) ------------- BUILDING DEPT PR ENire ---- ---- -- - APPLICANT: BUILDING •PERMIT CITY OF COLLEGE STATIO1 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00002256 Date 7/17/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 490.00 490.00 .00 .00 ------------------------Q--------------i---- /'--�---------------------------- BUILDING DEPT R39RESENTA APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIOP 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 03-00002256 Date 7/17/03 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1240.00 1240.00 .00 .00 BUILDING DEW REDRES APPLICANT: 1W'W�w CITY OF COLLEGE STATION WOR EQUEST PAGE 1 REQ/JOB: WF0428953 / 001 PROJECT: REQUEST DATE: 7/17/PRINT 03 CREW: PRINT TIME: 11:41:23 SCHSTART.DATT/17/03 LOCATION: 900 BOUGAINVILLEA ST 77845 COMPLETION: 7/17/03 GEN. LOC: COLLEGE STATION LOC ID: 194544 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: K M CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" SEWER 3/4" WATER 4" SEWER 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE Fa"OTroe UaOnly APPLICATION FOR BUILDING PER IT DATE:" 1 l'✓ �� CITY OF COLLEGE STATION � /} 3 /] APPLI ATION # �1 of 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP P LE # (979) 764-3570 (979) 764-3496 FAX W WW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: 1;00 '1�6Lmt^o' 1e5 LOT �_ BLOCK I SUBDIVISION �c�q �s SEC/PH BUSINESS/OWNER NAME: gm c4"IVw► 00"t S PHONE: S S 1 CONTRACTOR/HOMEOWNER: PHONE: CONTRACTOR ADDRESS: 10 05' (:"IA 2031 �� M c,.. r,;.CA 1 ? b ELECTRICIAN: �0.�� `« PLUMBER: -)l� HVAC: S� i GOOD CENTS (Residential only): ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION ING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) OJECT REGISTRATION# EABPRJ VALUATION: $ ) D 0 6 TOTAL AREA: 20 qL HEATED AREA: )T (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM EWER TAP: SIZE WATER TAP: SIZE OTHER TAP: SIZE TEMP POLE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE: ROOF TYPE GARAGE TYPE: SINGLE 0 DOUBLE �TRIPLE ATTACHED ®rDETACHED a 'CAYqOR SIGNATURE OF APPLICANT: >ircial Use Onlv � b Plans Exa finer Zoning Official C.,� co m )aftlnents: YE or NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls 1-3- Insulation R value of ceiling 1 (flat areas) 40 �U Insulation R value of ceiling 2 (vaulted areas/no attic) 30 Glazing SHGC ' Glazing U-Factor R value of ductwork A/C SEER rating 12-- I Ni I � I 25' REAR SETS K ! --------------- r---------- ., -------------� ; ; ; Y ' � � ' U m Y U ; ' ; ' ; w w ;� � to 0 s t0 ; '� I s --, / L o ---- ---- o- 25' B.S.L. I I I o I � .1 G' WIDE I I I I N CONC I I DRIVE I I lc) I L q'QC BOUGAINVILLEA ST. SUNMEADOWS PH-2 BLK-7 LOT -&I