Loading...
HomeMy WebLinkAboutRES2003-02250PREPARED 11/18/03, 7:26:41 INSPECTION TICKET PAGE 2 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/17/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 2017 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC 1 PH 2 CONTRACTOR WESTHERHEIM CUSTOM HOMES PHONE (979) 680-1655 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-2102-0380 APPL NUMBER: 03-00002250 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/28/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 7/29/03 AP 07/28/2003 09:04 AM MALFORD a SETBACKS PER STRINGS. SLAB GROUND @ LEFT BACK L O1 8/29/03 TB BLDG, FRAMING TIME: 17:00 8/29/03 AP 08/29/2003 11:12 AM MALFORD B124 01 1/1Q7/03 BLDG, FINAL TIME: 17:00 3 11/17/2003 12:45 PM GCARRILLO ---'---------------------------------- COMMENTS AND NOTES ------------------- - I w;c CITY OF COLLEGE STATION WORK (QUEST PAGE' 1 REQ/JOB: WF0429533 / 001 PROJECT: REQUEST DATE: 7/181PRINT 8/03 CREW: PRINT TIME: 13:32:05 SCHEDULE DATES LOCATION: 2017 RAVENSTONE LOOP START: 7/18/03 77845 COMPLETION: 7/18/03 GEN. LOC: COLLEGE STATION LOC ID: 193392 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: WESTHERHEIM CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE ,,, W C H .6 WESTERHEIM CUSTOM HOMES ,x...,V..�_-� August 28, 2003 To: City of College Station Development Services From: Brandon S. Westerheirn , Westerheim Custom Homes The Electrical Contractor for 2017 Ravenstone should be listed as College Station Electric. Thank you, Ed WUTR:�_O 200E 8Z 'E S9bZ b69 6Z6: 'ON Xdd S9WOH woisn0 WI3HdaiS9M: W06J 4 CITY OF COLLEGE STATION +� TZEQUEST�Aj PAGE 1 WOR- REQ/JOB: WF0426806 1 001 PROJECT: REQUEST DATE: 7/14/03 PRINT DATE: 7/14/03 CREW: PRINT TIME: 9:18:41 SCHSTART.DATT/14/03 LOCATION: 2017 RAVENSTONE LOOP 77845 COMPLETION: 7/14/03 GEN. LOC: COLLEGE STATION LOC ID: 193392 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: WESTERHEIM CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE 3/4" WATER 4" SEWER 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE tiUlLLllVli Y�KP/11'1' COLLEGE STATION, TX 77846 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . Property Address . . . Property ID R# . . . . . . . . . . Application description Subdivision Name . . . Property Use . . . . . Property Zoning . . . . Application valuation . . . . 03-00002250 Date 7/14/03 . . . 2017 RAVENSTONE LOOP 184200-2102-0380 R111220 . . . RESIDENTIAL, 1 UNIT DETACHED NEW . . . CASTLEGATE SEC 1 PH 2 . . . RESIDENTIAL . . . UNKNOWN . . . 146850 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD OWNER 4490 CASTLEGATE DR mS1-e.,rhuh-, cto6", Wowj-4-, COLLEGE STATION TX 778453388 k &Vhel m ------ Structure Information SINGLE FAMILY HOME ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2225.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KE Permit Fee . . . . 601.00 Plan Check Fee .00 Issue Date . . . . 7/14/03 Valuation . . . . 146850 Expiration Date . . 1/11/04 Qty Unit Charge Per Extension BASE FEE 460.00 47.00 3.0000 THOU BLDG, VAL 100001-500000 141.00 ---------------------------------------------------------------------------- Special Notes and Comments ADD SMOKE DETECTOR(S) PER NOTES ON PLANS ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) BUILDING DEPT $1PP&SEITATI /IE : APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIC 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00002250 Date 7/14/03 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. REQUIRED EXIT DOORS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE OF A KEY,TOOL OR SPECIAL KNOWLEDGE/EFFORT POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged ---------- Paid Credited -------------------- Due ----------------- Permit Fee Total ---------- 601.00 601.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1351.00 1351.00 .00 .00 ------------------- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . BUILDING DEPT IAPRF/rSENT�TI,VE APPLICANT: 03-00002250 Page 3 Date 7/14/03 ! 14 ------------------------- TEMPORARY POLE PERMIT CITY OF COLLEGE STATIO' 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID Application description Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . Application valuation . . 03-00002251 2017 RAVENSTONE LOOP 184200-2102-0380 TEMP POLE . CASTLEGATE SEC 1 PH 2 RESIDENTIAL UNKNOWN 0 Date 7/14/03 Owner Contractor ------------------------ ------------------------ GREENS PRAIRIE INVESTORS LTD OWNER 4490 CASTLEGATE DR COLLEGE STATION TX 778453388 --------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KE Permit Fee . . . . 20.00 Issue Date . . . . 7/14/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ----------------- ---------- Permit Fee Total 20.00 Other Fee Total 45.00 Grand Total 65.00 ------------------- BUILDING DE APPLICANT: Paid Credited Due ------------------------------ 20.00 .00 .00 45.00 .00 .00 65.00 .00 .00 APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US SS For Office Use Only "( DATE: _11_0 3 APPLICATION # �j03 ' RAS a TEMP POLE # ADDRESS/LOCATION: -LO17 RAVEN57,oN6 t—['>OP LOT � �� BLOCK 2- SUBDIVISION C A,5T`E6 ATE 5 E O 11, PH 2 BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: WE51ERVjEIM CUSTOM "o.AAEs PHONE: a761'575-8853 CONTRACTOR ADDRESS: 1660 SauTH wE5 t PKW`r A-402. ELECTRICIAN: FAVEL.r-A C►.6CM%C HVAC: SEI&F-P--' HEAnw& t At2 PLUMBER: BR v7'bs PLUM $ f N C- GOOD CENTS (Residential onyy CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (TotallPartial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) >< NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: S I Ma1-E FAMILY Dw F_"uN 6 HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 10 5.LWOa- O 1% SSD . TOTAL AREA: 1 5 3 HEATED AREA: -4 2-2-5 ,e�Labor and Materials) © PUBLIC SEWER SEPTIC/TREATMENT SYSTEM © SEWER TAP: ® WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE: SIZE 3/y " SIZE SIZE SINGLE ATTACHE SIGNATURE OF APPLICANT: NUMBER OF BEDROOMS: 3 NUMBER OF BATHROOMS: 2 INTERIOR WALL TYPE: 2 x� &_Xf! EXTERIOR WALL TYPE: g R I G ►G FOUNDATION TYPE: '5 I. -A R b N 6 RA Ds ROOF TYPE: CoMPos team S"tN&L.G 5 DOUBLE ® TRIPLE Official Use Only / l ents: (h ES r NO Plans Examiner Zoning Official a � � �, &�� tl-t (� vlZ- (3 �o SI�GC• •� �` C�sf O ON 4 O Cu Scala 1' — 30, m W N i 1s r/ Wash9heim Address 2017 Rovenstone Loop Sub: Costlegate Lot: vl,�, 3 Section: 1 CuStOMHOMOS Block: 2 Phase: 2 Permit Number REScheck Compliance Certificate Checked By/Date 1995 MEC RES checkSoftware Version 3.5 Release 1 d Data filename: C:\Program Files\Check\REScheck\2017 Ravenstone.rck PROJECT TITLE: 2017 Ravenstone Loop CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/06/03 DATE OF PLANS: July 6, 2003 PROJECT DESCRIPTION: Castlegate, Section 1, Phase 2 DESIGNER/CONTRACTOR: Westerheim Custom Homes COMPLIANCE: Passes Maximum UA = 906 Your Home UA = 710 21.6% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling l: Flat Ceiling or Scissor Truss 2225 30.0 0.0 78 Wall 1: Wood Frame, 16" o.c. 2224 13.0 3.6 127 Window 1: Metal Frame:Double Pane with Low-E 320 0.640 205 Door 1: Glass 45 0.310 14 Door 2: Solid 24 0.150 4 Floor 1: Slab -On -Grade: Unheated 271 0.0 282 Insulation depth: 2.0' Furnace 1: Forced Hot Air, 78 AFUE Boiler 1: Gas -Fired Steam, 75 AFUE Air Conditioner 1: Electric Central Air, 13 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 1995 MEC requirements in REScheckVersion 3.5 Release I (formerly MECchec� and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer Date