Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-02193
PREPARED 1/08/04, 11:59:42 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/08/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 1077 WINDMEADOWS DR SUBDIV: WESTFIELD VILLAGE PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER STYLECRAFT BUILDERS INC PHONE PARCEL 650730-0101-0320 APPL NUMBER: 03-00002193 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/22/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 7/23/03 AP 07/22/2003 09:03 AM SSTANLEY RAISE STEEL OFF PLUMBING PIPES IN BEAMS. SLAB GROUND BACK LEFT. SETBACK STRINGS PULLED. B115 O1 9/18/03 CH BLDG, FRAMING TIME: 17:00 9/18/03 AP 09/18/2003 08:24 AM GCARRILLO B130 01 9/22/03 CH BLDG, INSULATION TIME: 17:00 9/23/03 AP 09/22/2003 08:12 AM SSTANLEY B125 01 1/08/04 BI BLDG, FINAL TIME: 17:00 O1/08/2004 08:50 AM GCARRILLO ---:----------------------------------- COMMENTS AND NOTES -------------------------------------- 'i. bf CITY OF COLLEGE STATION ` WORK REQUEST PAGE 1 REQ/JOB: WF0429630 / 001 PROJECT: ° REQUEST DATE: 7/18/03 PRINT DATE: 7/18/03 CREW: PRINT TIME: 15:01:49 SCHSTART.DATE/18/03 LOCATION: 1077 WINDMEADOWS DR 77845 COMPLETION: 7/18/03 GEN. LOC: COLLEGE STATION LOC ID: 195804 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BLDRS (690-1222) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE UI DZNG PERMIT 11 T, COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002193 Date 7/15/03 Property Address . . . . . . 1077 WINDMEADOWS DR Property ID 650730-0101-0320 R # . . . . . . R113313 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 108900 Owner Contractor ------------------------ STYLECRAFT BUILDERS INC ------------------------ STYLECRAFT BUILDERS 4112 SH-6 S RANDY FRENCH COLLEGE STATION TX 778458964 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ------ Structure Information SINGLE FAMILY RESIDENCE ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE SIDING IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1650.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 487.00 Plan Check Fee .00 Issue Date . . . . 7/15/03 Valuation . . . . 108900 Expiration Date . . 1/12/04 Qty Unit Charge Per Extension BASE FEE 460.00 9.00 3.0000 THOU BLDG, VAL 100001-500000 27.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT q: BUILDING DEPT REPRESENTATIVE: �" APPLICANT: JLL" ( �P -% test& BUILDING PERMIT CITY OF COLLEGE STATIOT llbl TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 2 Application Number . . . . . 03-00002193 Date 7/15/03 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 487.00 487.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 ------------------------------------------------- -- �?- - ------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIOF 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 03-00002193 Date 7/15/03 Grand Total 1237.00 1237.00 .00 .00 -------- ---- BUILDING DEPT --------------- REPRESENTATIVE: APPLICANT: — �`� S�ppy (e Ci47Y TEMPORARY POLE PERMIT CITY OF COLLEGE STATIOY 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002194 Date 7/15/03 Property Address . . . . . . 1077 WINDMEADOWS DR Property ID . . . . . . . . . 650730-0101-0320 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ STYLECRAFT BUILDERS INC ------------------------ STYLECRAFT BUILDERS 4112 SH-6 S RANDY FRENCH COLLEGE STATION TX 778458964 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 7/15/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 --------------------------------------------------- 1-1 -- -- ----------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: CITY OF COLLEGE STATION WOR] EQUEST PAGE 1 REQ/JOB: WF0428122 / 001 PROJECT: REQUEST DATE: 7/16/03 PRINT DATE: 7/16/03 CREW: PRINT TIME: 8:21:13 DULS SCHSTARE.DATE/16/03 LOCATION: 1077 WINDMEADOWS DR 77845 COMPLETION: 7/16/03 GEN. LOC: COLLEGE STATION LOC ID: 195804 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" SEWER 3/4" WATER 4" SEWER 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE L APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WW W.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: _ LOT BLOCK DATE: I r K -n 3 APPLICATION # 03 TEMP POLE # 0 3 I q4- SUBDIVISION l 1 �, �I I PHASE BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Hiahwav 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Familv Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS $ ACCESSIBILITY�o STANDARD (TAS) PRO IeTOTAL AREA:al -15 RJ VA UATION:HEATED AREA: kasQ (Cosh of La or and Materials) If PUBLIC SEWER SEPTIC/TREATMENT SYSTEM 0 SEWER TAP: 0 WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE 4" SIZE g/ n SIZE SIZE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition SINGLE F] DOUBLE F__] TRIPLE ATTACHED SIGNATURE OF APPLICANT: Plans Examiner DETACHED. F__] CARPORT Official Use Only Zoning Official ents: YESfir NO Energy Code Compliance Information % Glazing of exterior walls r� % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 b 0 REScheck Compliance Certificate 2000 IECC RES check Software Version 3.5 Release lc Data filename: S:\ACAD\REScheck\1700-1650_1704 Kingsagte.cck TITLE: PLAN #1700-1650 Front Porch Series CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/08/03 DATE OF PLANS: 03-21-03 PROJECT INFORMATION: SPEC 1077 Windmeadows College Station, TX COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: Passes Maximum UA = 621 Your Home UA = 557 10.3% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall l: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 3: Solid Door 2: Glass SHGC: 0.40 Floor 1: Unheated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1333 30.0 0.0 47 338 19.0 0.0 18 1504 13.0 0.0 97 262 0.650 170 18 0.500 9 20 0.500 10 18 0.580 10 188 0.0 196 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lc (formerly MECchecl) and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date REScheck Inspection Checklist 2000 IECC RES check Software Version 3.5 Release lc DATE: 07/08/03 TITLE: PLAN #1700-1650 Front Porch Series Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.650 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.500 Comments: 2. Door 3: Solid, U-factor: 0.500 Comments: 3. Door 2: Glass, U-factor: 0.580 Comments: Floors: 1. Floor 1: Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. I Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. I Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics I (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. I Exception: Continuously welded and locking -type longitudinal joints and seams on ducts I operating at less than 2 in. w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. i Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% 1 of the heating energy is from non-depletable sources. Pool pumps require a time clock. I I Heating and Cooling Piping Insulation: I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. a Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to V Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Assembly Type Comments/ Description Imp ��■�■����� Imp ��■�■����� Window Area Total: 254.17 07/08/03 08:07:08 1 /1 Area Calculator: Assembly Type Description Door Area Total: 37.78 07/08/03 08:07:09 1/1 Area Calculator: E Assembly Type Comments/Description ® IMOM■ ® IMEM■�■�� m IMEM■�■�� Ceiling Area Total: 1671.00 07/08/03 08:07:11 1/1 Area Calculator: Assembly 11=111©11=11INECT."T"EMComments/Description ... Frame, 16".■�■ Exterior Wall Area Total: 1504.00 07/08/03 08:07:11 1/1 Area Calculator: M-Assembly Type Comm ents/Description Floor Area Total: 0.00 07/08/03 08:07:12 1 /1