Loading...
HomeMy WebLinkAboutRES2003-02184• CITY OF COLLEGE STATION WORK F TJEST... --- . _ ,e....... - �PAGE -.�pRQINTSDATETE: 1 RO REQ/JOB: WF0442592 / (?ul - PJE'TLr" 8f05%03 CREW: PRINT TIME: 16:18:37 SCHSTART.DAT8/05/03 LOCATION: 4211 COLCHESTER CT 77845 COMPLETION: 8/05/03 GEN. LOC: COLLEGE STATION LOC ID: 198020 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: DUSTY PHILLIPS ORIGIN: CUSTOMER -WALK IN USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE 3/4" WATER 4" SEWER 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES ACCT CSCS SET Task code: SET UP NEW UTILITY Facility ID . Assigned Department: OT-CUSTOMER SERVICE PREPARED 4/27/04, 7:39:21 INSPECTION TICKET PAGE 3 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/27/04 ------------------------------------------------------------------------------------------------ ADBRESS . : 4211 COLCHESTER CT SUBDIV: CASTLEGATE SEC 10,11,12,13 CONTRACTOR DUSTY PHILLIPS CONSTRUCTION PHONE (979) 229-4850 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-0102-0910 FPPL NUMBER: 03-00002184 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/12/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 8/13/03 AP 08/12/2003 02:40 PM SSTANLEY TERRY TO SIGN STRINGS ON SETBACKS, OK. SLAB GROUND BACK LEFT CORNER. B115 01 9/09/03 TB BLDG, FRAMING TIME: 17:00 9/09/03 AP 09/08/2003 02:32 PM GCARRILLO OK B130 01 9/10/03 TB BLDG, INSULATION TIME: 17:00 10/20/03 CA 09/09/2003 04:21 PM GCARRILLO 1st am/was supposed to have been done on tuesday pm 10/20/2003 02:51 PM MALFORD good cents home B125 01 4/27/04 I BLDG, FINAL TIME: 17:00 7710t{ 04/26/2004 03:21 PM MALFORD ok -{------------------------------------ COMMENTS AND NOTES -------------------------------------- is r nsi� l(pc11 �� —7 Mandi Alford - Insulation request inspection result, 4211 Colchester, #03-2184 Page 1 From: Brian Henry To: Elmendorf, Katy Date: 9/9/2003 4:34:16 PM Subject: Insulation request inspection result, 4211 Colchester, #03-2184 Print for File Inspected insulation, 4211 Colchester, #03-2184, Dusty Phillips, 9-9-03 Inspection result: Inspected OK for Good Cents Notes: Seal around A/C freon lines at the sheathing. CC: Alford, Mandi CITY OF COLLEGE STATION . • WORK, 'gUEST PAGE 11 a REQ/JOB: WF0445194 / 001 PROJECT: REQUEST DATE: 8/08/03 PRINT DATE: 8/08/03 CREW: PRINT TIME: 15:19:27 SCHSTART.DAT8/08/03 LOCATION: 4211 COLCHESTER CT 77845 COMPLETION: 8/08/03 GEN. LOC: COLLEGE STATION LOC ID: 198020 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: DUSTY PHILLIPS CONSTRUCTION ORIGIN: CUSTOMER -WALK IN USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE TEMP POLE APPROVED TEMP POLE APPROVED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US For Office Use Only DATE: APPLICATION # TEMP POLE # C) ADDRESS/LOC�4TION: 4/al C�Iesfier- LOT �_ BLOCK __R__ SUBDIVISION CaSfi��04-2 Cnynkn"w44e.$ SEC/PH i C) BUSINESS/OWNER NAME: QUts ��,;Ij, (clis(aezG «�, (ems PHONE:(5'1 CONTRACTOR/HOMEOWNER: 1, )USIc, h�nilli,ns PHONE: CONTRACTOR ADDRESS: ELECTRICIAN: PLUMBER: HVAC: C(rw,'IE V(C'54'S GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) V NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUXL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PF�OJECT REGISTRATION# EABPRJ VALUATION: $ 1 LPi. OtOO TOTAL AREA: RL41OL9 HEATED AREA: ('''% 3 (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM ❑ SEWER TAP: Li SIZE WATER TAP: 3 /y SIZE ❑ OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE ATTACHED SIGNATURE OF APPLICANT: vL+�I NUMBER OF BEDROOMS: L4 NUMBER OF BATHROOMS: a INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE � TRIPLE DETACHED F] CARPORT Official Use Only i1 on -Vents: 1-! 119163 YES r NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork la•q 13 Ra LO ,7.' A/C SEER rating i0 to Gee,( d DE,,.'RIPTION OF MATERIAi.� ON PROPOSED CONSTRUCTION Property Location 4211 Colchester City College Station State TX Mortgage (Name) (Address) Contractor or Builder Dusty Phillips Construction 4490 Castlegate Dr. College Station, TX 77845 (Name) (Address) INSTRUCTIONS 1. Describe all materials and 2. equipment to be used, whether or not shown on the drawings. by 4. Include no alternates, "or equal' phrases, or contradictory items. marking an X in each appropriate check -box and entering the (Consideration of a request for acceptance of substitute materials information called for in each space. If space in inadequate, enter or equipment is not thereby precluded.) "See misc." and describe under item 27 or on an attached sheet. 5. Include signatures required at the end of this form. 3. Work not specifically described or shown will not be considered 6. The construction shall be completed for value. 7. in compliance with the related drawings and specifications, as amended during processing. 1. EXCAVATION: Bearing soil, type Topsoil over rock 2. FOUNDATIONS: Per Plan Footings: concrete mix ; strength psi Reinforcing Foundation wall: material Reinforcing Piers: material and reinforcing Sills: material Waterproofing Termite protection Special foundations Additional information 3. CHIMNEYS: Material metal Prefabricated (stake and .st_e) heat-a-lator or equal 36" Additional information 4. FIREPLACES: Type: ®wood burning; Mgas-burning; Mcirculator (make and size) Ash dump and clean out N/A Fireplace: Facing S/R ; lining metal , hearth tile ; mantel wood Additional information 5. EXTERIOR WALLS: Wood frame: wood grade, and species #2 Y.P. MCorner bracing. Building paper or felt Brick veneer $285/mo type Stone veneer N/A Sheathing 1/2" ; thickness ; width ; Msolid: ❑spaced " o.c.; ❑diagonal: Siding N/A ;grade ; type ; size : exposure "; fastening Shingles N/A ;grade ; type ; size ; exposure "; fastening Stucco N/A ;_thickness "; Lath ; weight Ib. Sills Lintels Base flashing Masonry: ❑ solid M faced ❑ stuccoed; total wall thickness 9 "; facing thickness 5 1/2 "; facing material brick Backup material sil-a-tex ; thickness 112" ": bonding nail Door sills brick Window sills brick Lintels iron Base flashing galvanized Interior surfaces: dampproofing, coats of :furring Additional information: Exterior painting: material prime oil finish 100% actylic latex ; Number of coats I & 1 Gable wall construction: M same as main walls, ❑ other construction 8. FLOOR FRAMING: Joists; wood, grade, and species ; other ; bridging ; anchors Concrete slab: M basement floor; ❑ first floor; M ground supported; ❑ self-supporting: mix 3000psi ; thickness 4 1/2 reinforcing rebar ; insulation N/A ; membrane poly Fill under slab: material sand ; thickness varies ": Additional information: 9. FINISH FLOORING: (Wood only, Describe other finish flooring under Item 20 Location Rooms Grade Species Thickness Width BI d. Paper Finish First floor Second floor Attic floor s . ft. Additional information: Form 2930 (Rev. 2/78) 8. PARTITION FRAMING: Studs: wood, grade, and species Y.P. #2 size -and spacing 2 x 4 16" o.c. Other Additional information 9. CEILING FRAMING: Joists: wood, grade, and species #2 Y.P. 2 x 6 16" o.c. Other Bridging Additional information 10. ROOF FRAMING: Rafters: Wood, grade, and species #2 Y.P. 2 x 6 24" o.c. Roof trusses (see detail): grade and species N/A Additional information 10. ROOFING: Sheathing: wood, grade, and species 9/16 O.S.B ; ® solid: ❑spaced "o.c. Roofing: composition ; grade A ; size 12 x 36 ; type fiberglass Underlay: felt ; weight or thickness I - 5 ; size 36" ; fastening nail Built-up roofing: N/A ; number of plies ; surfacing material Flashing: material: galvanized ; gage or weight : ❑ gravel stops: ❑ snow guards Additional information: 12. GUTTERS AND DOWNSPOUTS: Gutters: material N/A Downspouts: material 13. INTERIOR WALLS: Dry -wall ® walls. ® ceilings: material S/R ; thickness 1/2 ; finish Stoop & Drag Lath ❑ walls, ❑ ceilings: material N/A ; weight or thickness : Plaster coats ;finish Joint treatment tape, float twice, sand & texture 14. DECORATING: (Paint, wallpaper, paneling, etc.) Rooms Wall Finish Material and Application Ceiling Finish Material and Application Kitchen Bath Bedrooms Den L/R — D/R 15. INTERIOR DOORS AND TRIM: Doors: type masonite 6 panel ; material ; thickness 1 3/8 Door trim: type C-I I ; material pine ; Base: type B-1 I ; material pine ; size Finish: doors: painted ; trim Other trim (item, type and location): crown 4 1/4" Additional information: 16. WINDOWS: Windows: type aluminum ; make Alenco : material Weatherstripping: type ; material Screens: ❑ full; ® half: type ; number : screen cloth material Special windows: per plan Additional information: 17. ENTRANCES AND EXTERIOR DETAIL: Main entrance door: material metal ; width 36 ; thickness 1 3/4 ". Frame material pine ; thicknessl 1/2 " Other entrance doors: material metal ; width 32 ; thickness 1 3/4 ". Frame material pine ; thicknessl 1/2 " Head flashing galvanized Weatherstripping: type mag. , saddles Screens doors: thickness N/A "; number ; screen cloth material Storm doors: thickness ; number Combination storm and screen doors: thickness N/A": number ; screen cloth material Shutters ❑ hinged: ❑ fixed. Railings N/A Attic louvers Exterior millwork: grade and species: walminized pine & fir Paint oil & latex ; number coats I & Additional information: 18. CABINETS AND INTERIOR DETAIL: Kitchen cabinets, wall units: material oak or birch : lineal feet of shelves : shelf width Base units: material ; counter top ; edging Back and end splash formica Finish of cabinets Stain or painted ; number coats Medicine cabinets: make N/A ; model Other cabinets and built-in furniture Additional information: 19. STAIRS: Stair Treads Risers Strings Handrail Balusters Material Thickness Material Thickness Material Size Material Size Material Size Basement Main Attic Disappearing: make and model number: Additional information: 20. SPECIAL FLOORS AND WAINSCOT: (Carpet, tile, linoleum): F Location Material, Color, Border, Sizes, Gage, Ete. Quality and Grade Wall Base Underfloor Material I or Allowances Material o o Kitchen Tile 5.50 wood N/A r Bath & Entry Tile 5.50 wood N/A s Bedrooms Carpet 16.00 wood N/A Den Carpet 16.00 wood N/A L/R — D/R Carpet 16.00 wood N/A it Location Material, Color, Border, Sizes, Gage, Etc. Height Height Over Height in Showers Tub From Floor n Baths Bathroom accessories: ❑ Recessed: material Additional information 21. PLUMBING: number ;❑Attached: material ; number Fixture Number Location Make Mfr's Fixture Identification No. Size Color Sink I kitchen S.S. Lavatory4 R.R. B owner Water Closet 2 R.R. White Bathtub 1 R.R. B Owner Shower over tub I R.R. By Owner Stall shower I R.R. By Owner Laundry trays ®Curtain rod ® Door ® Shower pan: material marble Water supply: ® public: ❑ community system; ❑ individual (private) system Sewage disposal: ® public: ❑ community system; ❑ individual (private) system *Show and describe individual system in complete detail in separate drawings and specifications according to requirements. House drain (inside): ❑ cast iron: ❑ tile: ® other PVC I louse sewer outside galvanized steel; (outside): ❑cast iron: ❑tile: ®other PVC Water piping: ❑ g ® copper tubing; ❑ other Sill cocks, number 3 Domestic water heater: type Gas : make and model O.A. Smith ; heating capacity aph 100' rise. Storage tank: material : capacity 40gallons Gas service: ® utility company; ❑ liq. pet. gas: ❑ other Gas piping: Footingdrains connected to: P P g ❑cooking: ❑house heating. El sewer: El sewer: ❑dry well. 22. HEATING: Warm air: ❑ Gravity. ® Forced. Type of system Lenox or equal Duct material: supply ; return Insulation thickness ❑ Outside air intake. Furnace: make and model Input : Btub: output Additional information: per A/C contractor ❑ Space heater: ❑ floor furnace; ❑ wall heater. Input Btub.; output Btub: number units Make, Model Additional information: Controls: make and types: Additional information: Fuel: ❑ Coal; ❑ oil; ❑ gas; ❑ liq. pet. gas; ❑ electric; ❑ other ; storage capacity Additional information: Electric heating system: type Input watts: at volts: output Btub. Additional information: Ventilating equipment: attic fan, make and model: Other heating, ventilating, or cooling equipment: 23. AIR CONDITIONING: Per A/C contractor Central air: make Type and size ducts ❑ cooling tower: ❑ electric; ❑ gas. ❑ Window units: make ; number of units ❑ Evaporator cooler: make ; number of units _ Other 24. ELECTRIC WIRING: B.T.U. capacity Service: ❑ overhead; ® underground. Panel: ❑ fuse box: ® circuit -breaker; make Wiring: ❑ conduit: ❑ armored cable; ❑ nonmetallic cable; ❑ Knob and tube: ❑ Other Special outlets: ❑ range; ❑ water heater; ❑ other ® Doorbell, ® chimes, Push-button locations Additional Information: B.T.U. capacity of each unit cu. 1i. rating AMP's No. circuits LIGHTING FIXTURES: Total number of fixtures Total allowance for fixtures, typical installation. $ $1200.00 Non -typical installation Additional information: per plan 25. INSULATION: Location Thickness Material, Type, and Method of Installation Vapor Barrier Roof R-19 Ceiling R-30 Wall R-13 Floor HARDWARE: (make, material, finish, or allowance.) 800.00 SPECIAL EQUIPMENT: (State material or make, model and quantity. Do not include items which, by established custom, are supplied by occupant and removed when he vacates premises or chattels prohibited by law from becoming reality.) allow:$1,200.00 Built-in range and oven ❑ ; make Model Built-in refrigerator ❑ ; make Cu. Ft. Ice Maker ❑ : make Model Garbage disposal ❑ ; make Model Dishwasher ❑ ; make Model Venthood Model Other: 26. MISCELLANEOUS: (Describe any main dwelling materials, equipment, or construction items not shown elsewhere: or use to provide additional information where the space provided was inadequate. Always reference by item number to correspond to numbering used on this form.) Sprinkler yard allow $1,600.00 Grass & plants allow $2,000.00 Cedar fence back & side w/one gate PORCHES: per plan TERRACES: GARAGES: per blan WALKS AND DRIVEWAYS: per plot plan Driveway: width ;base material ; thickness "; surfacing material ; thickness Front walk: width ; material ; thickness ; Service walk: width ; material ; thickness Steps: Material OTHER ONSITE IMPROVEMENTS: (Specify all exterior onsite improvements not described elsewhere, including items such as unusual grading, drainage structures, retaining walls, fence, railings, and accessory structures.) LANDSCAPING, PLANTING, AND FINISH GRADING: Topsoil " thick: ® front yard; ® side yards; ® rear yard to feet behind main building. Lawns (seeded, sodded, or sprigged): ® front yard sodded : ® side yards sodded ; ® rear yard sodded Planting: ❑ as specified and shown on drawings; ❑ as follows: Shade Trees, deciduous, " caliper. Evergreen trees: to B & B Low flowering trees, deciduous, to Evergreen shrubs: to B & B Hi -growing shrubs, deciduous, to Vines, 2-year Medium -growing shrubs, deciduous, to Low -growing shrubs, deciduous, to IDENTIFICATION. This exhibit shall be identified by the signature of the builder and mortgagor. Date July 3, 2003 Signatu Contract Price $169,900.00 Signatu Contractor or Builder Land Owner ENE GODS SPECFCAiIONS GROSS WALL SQ. FT.: 1,868.3113 PERCENTAGE OF FENESTRATION FENESTRATION SQ. FT.: 240.9111 TO WALL RATIO: 12.9% IN ACCORDANCE WITH CHAPTER 5 OF THE INTERNATIONAL ENERGY CONSERVATION CODE, AND BASED ON THE PRESCRIPTIVE BUILDING ENVELOPE REQUIREMENTS FOR THE BRYAN/COLLEGE STATION AREA, THE FOLLOWING SPECIFICATIONS WILL APPLY: TABLE 502.2.4(3), MAX 15% RATIO MAXIMUM GLAZING U FACTOR: 0.75 MINIMUM EXTERIOR WALL R—VALUE: R-13 MINIMUM CEILING R—VALUE: R-2(o MINIMUM HVAC SEER VALUE: 10 SEER s ENERGY CODE SPECS CALCULATED FOR: DUSTY PHILLIPS CONSTRUCTION DATED: 06/20/03 i ol SITE PLAN 0 renesw�eo ►ioru sw a 1•-W-o' Mom INaNk -Pbo, LOT s 91 BLOCKi 02 SUBDIVISIONt CASTLEGATE SECTION 10 COLLEGE STATION, TEXAS BRAZOS COUNTY COLCHESTER ,- . COURT PROPERTY LINE, L - 97.07' B - N 6I'41'01' W R - 50.0' BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002184 Date 8/05/03 Property Address . . . . . . 4211 COLCHESTER CT Property ID 184200-1002-0910 R # . . . . . . . . R***** Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 10 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 169900 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS ------------------------ LTD DUSTY PHILLIPS CONSTRUCTION 4490 CASTLEGATE DR DUSTY PHILLIPS COLLEGE STATION TX 778453388 4490 CASTLEGATE DRIVE COLLEGE STATION TX 77845 (979) 229-4850 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1843.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KE Permit Fee . . . . 670.00 Plan Check Fee .00 Issue Date . . . . 8/05/03 Valuation . . . . 169900 Expiration Date . . 2/02/04 Qty Unit Charge Per Extension BASE FEE 460.00 70.00 3.0000 THOU BLDG, VAL 100001-500000 210.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number 03-00002184 Page 2 Date 8/05/03 Special Notes and Comments PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S) ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS-18" ABOVE THE FLOOR IN PRIVATE GARAGES Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid -------------------- Credited -------------------- Due ----------------- Permit Fee Total 670.00 670.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 BUILDING DEPT EPRESENTATIVE: APPLICANT: �1 �% BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 03-00002184 Date 8/05/03 Grand Total 1420.00 1420.00 .00 .00 BUILDING DEPT EPRESENTATIVE : AP PL I CANT :141�71-414� TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID R # . Application description . Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . Application valuation . . 03-00002185 4211 COLCHESTER CT 184200-1002-0910 . R***** TEMP POLE CASTLEGATE SEC 10 RESIDENTIAL PLANNED DEVL HOUSING 0 Date 8/05/03 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ DUSTY PHILLIPS CONSTRUCTION 4490 CASTLEGATE DR DUSTY PHILLIPS COLLEGE STATION TX 778453388 4490 CASTLEGATE DRIVE COLLEGE STATION TX 77845 (979) 229 -4 850 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KE Permit Fee . . . . 20.00 Issue Date . . . . 8/05/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: Lxx:741��-