HomeMy WebLinkAboutRES2003-02184• CITY OF COLLEGE STATION
WORK F TJEST... --- . _ ,e....... -
�PAGE
-.�pRQINTSDATETE:
1
RO
REQ/JOB: WF0442592 / (?ul - PJE'TLr"
8f05%03
CREW:
PRINT TIME:
16:18:37
SCHSTART.DAT8/05/03
LOCATION: 4211 COLCHESTER CT
77845
COMPLETION:
8/05/03
GEN. LOC: COLLEGE STATION LOC ID:
198020
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR: DUSTY PHILLIPS
ORIGIN: CUSTOMER -WALK
IN
USER ID: KELMENDORF AUTH: KELMENDORF WORK
TYPE: ROUTINE
3/4" WATER 4" SEWER
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES
ACCT
CSCS
SET
Task code: SET UP NEW UTILITY
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
PREPARED
4/27/04, 7:39:21
INSPECTION TICKET
PAGE 3
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 4/27/04
------------------------------------------------------------------------------------------------
ADBRESS
. : 4211 COLCHESTER CT
SUBDIV: CASTLEGATE
SEC 10,11,12,13
CONTRACTOR DUSTY PHILLIPS CONSTRUCTION PHONE (979) 229-4850
OWNER
GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL
184200-0102-0910
FPPL NUMBER: 03-00002184 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
8/12/03 TB
BLDG, FOUNDATION -SLAB TIME: 17:00
8/13/03 AP
08/12/2003 02:40 PM SSTANLEY
TERRY TO SIGN
STRINGS ON SETBACKS, OK. SLAB GROUND
BACK LEFT CORNER.
B115 01
9/09/03 TB
BLDG, FRAMING TIME: 17:00
9/09/03 AP
09/08/2003 02:32 PM GCARRILLO
OK
B130 01
9/10/03 TB
BLDG, INSULATION TIME: 17:00
10/20/03 CA
09/09/2003 04:21 PM GCARRILLO
1st am/was supposed to have been done
on tuesday pm
10/20/2003 02:51 PM MALFORD
good cents home
B125 01
4/27/04 I
BLDG, FINAL TIME: 17:00
7710t{
04/26/2004 03:21 PM MALFORD
ok
-{------------------------------------
COMMENTS AND NOTES --------------------------------------
is r nsi� l(pc11 �� —7
Mandi Alford - Insulation request inspection result, 4211 Colchester, #03-2184 Page 1
From: Brian Henry
To: Elmendorf, Katy
Date: 9/9/2003 4:34:16 PM
Subject: Insulation request inspection result, 4211 Colchester, #03-2184
Print for File
Inspected insulation, 4211 Colchester, #03-2184, Dusty Phillips, 9-9-03
Inspection result: Inspected OK for Good Cents
Notes:
Seal around A/C freon lines at the sheathing.
CC: Alford, Mandi
CITY OF COLLEGE STATION
. •
WORK, 'gUEST
PAGE
11
a
REQ/JOB:
WF0445194 / 001 PROJECT:
REQUEST DATE:
8/08/03
PRINT DATE:
8/08/03
CREW:
PRINT TIME:
15:19:27
SCHSTART.DAT8/08/03
LOCATION:
4211 COLCHESTER CT
77845
COMPLETION:
8/08/03
GEN. LOC:
COLLEGE STATION LOC ID: 198020
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
DUSTY PHILLIPS CONSTRUCTION ORIGIN:
CUSTOMER -WALK
IN
USER ID:
KELMENDORF AUTH: KELMENDORF WORK TYPE:
ROUTINE
TEMP POLE
APPROVED
TEMP POLE
APPROVED
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID .
Assigned Department:
OT-CUSTOMER SERVICE
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEGE-STATION.TX.US
For Office Use Only
DATE:
APPLICATION #
TEMP POLE # C)
ADDRESS/LOC�4TION: 4/al C�Iesfier-
LOT �_ BLOCK __R__ SUBDIVISION CaSfi��04-2 Cnynkn"w44e.$ SEC/PH i C)
BUSINESS/OWNER NAME: QUts ��,;Ij, (clis(aezG «�, (ems PHONE:(5'1
CONTRACTOR/HOMEOWNER: 1, )USIc, h�nilli,ns PHONE:
CONTRACTOR ADDRESS:
ELECTRICIAN: PLUMBER:
HVAC: C(rw,'IE V(C'54'S GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) V NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEL/RENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK:
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUXL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PF�OJECT REGISTRATION# EABPRJ
VALUATION: $ 1 LPi. OtOO TOTAL AREA: RL41OL9 HEATED AREA: ('''% 3
(Cost of Labor and Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
❑ SEWER TAP: Li
SIZE
WATER TAP: 3 /y
SIZE
❑ OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE
ATTACHED
SIGNATURE OF APPLICANT: vL+�I
NUMBER OF BEDROOMS: L4
NUMBER OF BATHROOMS: a
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
DOUBLE � TRIPLE
DETACHED F] CARPORT
Official Use Only
i1 on -Vents:
1-! 119163 YES r NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
la•q
13
Ra LO
,7.'
A/C SEER rating i0
to Gee,( d
DE,,.'RIPTION OF MATERIAi.�
ON PROPOSED CONSTRUCTION
Property Location 4211 Colchester City College Station State TX
Mortgage
(Name) (Address)
Contractor or Builder Dusty Phillips Construction 4490 Castlegate Dr. College Station, TX 77845
(Name) (Address)
INSTRUCTIONS
1. Describe all materials and
2. equipment to be used, whether or not shown on the drawings. by 4.
Include no alternates, "or equal' phrases, or contradictory items.
marking an X in each appropriate check -box and entering the
(Consideration of a request for acceptance of substitute materials
information called for in each space. If space in inadequate, enter
or equipment is not thereby precluded.)
"See misc." and describe under item 27 or on an attached sheet. 5.
Include signatures required at the end of this form.
3. Work not specifically described or shown will not be considered 6.
The construction shall be completed
for value.
7. in compliance with the related drawings and specifications, as amended during processing.
1. EXCAVATION:
Bearing soil, type Topsoil over rock
2. FOUNDATIONS: Per Plan
Footings: concrete mix ; strength psi
Reinforcing
Foundation wall: material
Reinforcing
Piers: material and reinforcing
Sills: material
Waterproofing
Termite protection
Special foundations
Additional information
3. CHIMNEYS:
Material metal Prefabricated (stake and .st_e) heat-a-lator or equal 36"
Additional information
4. FIREPLACES:
Type: ®wood burning; Mgas-burning; Mcirculator (make and size) Ash dump and clean out N/A
Fireplace: Facing S/R ; lining metal , hearth tile ; mantel wood
Additional information
5. EXTERIOR WALLS:
Wood frame: wood grade, and species #2 Y.P.
MCorner bracing. Building paper or felt
Brick veneer $285/mo
type
Stone veneer N/A
Sheathing 1/2" ; thickness ; width
; Msolid: ❑spaced
" o.c.; ❑diagonal:
Siding N/A ;grade ; type
; size
: exposure "; fastening
Shingles N/A ;grade ; type
; size
; exposure "; fastening
Stucco N/A ;_thickness
"; Lath
; weight Ib.
Sills Lintels
Base flashing
Masonry: ❑ solid M faced ❑ stuccoed; total wall thickness 9
"; facing thickness 5 1/2
"; facing material brick
Backup material sil-a-tex
; thickness 112"
": bonding nail
Door sills brick Window sills brick
Lintels iron
Base flashing galvanized
Interior surfaces: dampproofing, coats of
:furring
Additional information:
Exterior painting: material prime oil finish 100% actylic latex
; Number of coats I & 1
Gable wall construction: M same as main walls, ❑ other construction
8. FLOOR FRAMING:
Joists; wood, grade, and species ; other ; bridging ; anchors
Concrete slab: M basement floor; ❑ first floor; M ground supported; ❑ self-supporting: mix 3000psi ; thickness 4 1/2
reinforcing rebar ; insulation N/A ; membrane poly
Fill under slab: material sand ; thickness varies ": Additional information:
9. FINISH FLOORING: (Wood only, Describe other finish flooring under Item 20
Location
Rooms
Grade
Species
Thickness Width
BI d. Paper
Finish
First floor
Second floor
Attic floor
s . ft.
Additional information:
Form 2930 (Rev. 2/78)
8. PARTITION FRAMING:
Studs: wood, grade, and species Y.P. #2 size -and spacing 2 x 4 16" o.c. Other
Additional information
9.
CEILING FRAMING:
Joists: wood, grade, and species #2 Y.P. 2 x 6 16" o.c.
Other
Bridging
Additional information
10.
ROOF FRAMING:
Rafters: Wood, grade, and species #2 Y.P. 2 x 6 24" o.c.
Roof trusses (see detail):
grade and species N/A
Additional information
10.
ROOFING:
Sheathing: wood, grade, and species 9/16 O.S.B
; ® solid: ❑spaced "o.c.
Roofing: composition ; grade A
; size 12 x 36
; type fiberglass
Underlay: felt
; weight or thickness I - 5
; size 36" ; fastening nail
Built-up roofing: N/A
; number of plies
; surfacing material
Flashing: material: galvanized
; gage or weight
: ❑ gravel stops: ❑ snow guards
Additional information:
12.
GUTTERS AND DOWNSPOUTS:
Gutters: material N/A
Downspouts: material
13.
INTERIOR WALLS:
Dry -wall ® walls. ® ceilings: material S/R
; thickness 1/2
; finish Stoop & Drag
Lath ❑ walls, ❑ ceilings: material N/A
; weight or thickness
: Plaster coats ;finish
Joint treatment tape, float twice, sand & texture
14.
DECORATING: (Paint, wallpaper, paneling, etc.)
Rooms
Wall Finish Material and Application
Ceiling Finish Material and Application
Kitchen
Bath
Bedrooms
Den
L/R — D/R
15. INTERIOR DOORS AND TRIM:
Doors: type masonite 6 panel ; material ; thickness 1 3/8
Door trim: type C-I I ; material pine ; Base: type B-1 I ; material pine ; size
Finish: doors: painted ; trim
Other trim (item, type and location): crown 4 1/4"
Additional information:
16. WINDOWS:
Windows: type aluminum ; make Alenco : material
Weatherstripping: type ; material
Screens: ❑ full; ® half: type ; number : screen cloth material
Special windows: per plan
Additional information:
17. ENTRANCES AND EXTERIOR DETAIL:
Main entrance door: material metal ; width 36 ; thickness 1 3/4 ". Frame material pine ; thicknessl 1/2 "
Other entrance doors: material metal ; width 32 ; thickness 1 3/4 ". Frame material pine ; thicknessl 1/2 "
Head flashing galvanized Weatherstripping: type mag. , saddles
Screens doors: thickness N/A "; number ; screen cloth material Storm doors: thickness ; number
Combination storm and screen doors: thickness N/A": number ; screen cloth material
Shutters ❑ hinged: ❑ fixed. Railings N/A Attic louvers
Exterior millwork: grade and species: walminized pine & fir Paint oil & latex ; number coats I &
Additional information:
18. CABINETS AND INTERIOR DETAIL:
Kitchen cabinets, wall units: material oak or birch : lineal feet of shelves : shelf width
Base units: material ; counter top ; edging
Back and end splash formica Finish of cabinets Stain or painted ; number coats
Medicine cabinets: make N/A ; model
Other cabinets and built-in furniture
Additional information:
19. STAIRS:
Stair
Treads
Risers
Strings
Handrail
Balusters
Material
Thickness
Material
Thickness
Material
Size
Material
Size
Material
Size
Basement
Main
Attic
Disappearing: make and model number:
Additional information:
20. SPECIAL FLOORS AND WAINSCOT: (Carpet, tile, linoleum):
F
Location
Material, Color, Border, Sizes, Gage, Ete.
Quality and Grade
Wall Base
Underfloor Material
I
or Allowances
Material
o
o
Kitchen
Tile
5.50
wood
N/A
r
Bath & Entry
Tile
5.50
wood
N/A
s
Bedrooms
Carpet
16.00
wood
N/A
Den
Carpet
16.00
wood
N/A
L/R — D/R
Carpet
16.00
wood
N/A
it
Location
Material, Color, Border, Sizes, Gage, Etc.
Height
Height Over
Height in Showers
Tub
From Floor
n
Baths
Bathroom accessories: ❑ Recessed: material
Additional information
21. PLUMBING:
number ;❑Attached: material ; number
Fixture
Number
Location
Make
Mfr's Fixture Identification No.
Size
Color
Sink
I
kitchen
S.S.
Lavatory4
R.R.
B owner
Water Closet
2
R.R.
White
Bathtub
1
R.R.
B Owner
Shower over tub
I
R.R.
By Owner
Stall shower
I
R.R.
By Owner
Laundry trays
®Curtain rod ® Door ® Shower pan: material marble
Water supply: ® public: ❑ community system; ❑ individual (private) system
Sewage disposal: ® public: ❑ community system; ❑ individual (private) system
*Show and describe individual system in complete detail in separate drawings and specifications according to requirements.
House drain (inside): ❑ cast iron: ❑ tile: ® other PVC I louse sewer outside
galvanized steel; (outside): ❑cast iron: ❑tile: ®other PVC
Water
piping: ❑ g ® copper tubing; ❑ other Sill cocks, number 3
Domestic water heater: type Gas : make and model O.A. Smith ; heating capacity
aph 100' rise. Storage tank: material : capacity 40gallons
Gas service: ® utility company; ❑ liq. pet. gas: ❑ other Gas piping:
Footingdrains connected to: P P g ❑cooking: ❑house heating.
El sewer: El sewer: ❑dry well.
22. HEATING:
Warm air: ❑ Gravity. ® Forced. Type of system Lenox or equal
Duct material: supply ; return Insulation thickness ❑ Outside air intake.
Furnace: make and model Input : Btub: output
Additional information: per A/C contractor
❑ Space heater: ❑ floor furnace; ❑ wall heater. Input Btub.; output Btub: number units
Make, Model Additional information:
Controls: make and types:
Additional information:
Fuel: ❑ Coal; ❑ oil; ❑ gas; ❑ liq. pet. gas; ❑ electric; ❑ other ; storage capacity
Additional information:
Electric heating system: type Input watts: at volts: output Btub.
Additional information:
Ventilating equipment: attic fan, make and model:
Other heating, ventilating, or cooling equipment:
23. AIR CONDITIONING: Per A/C contractor
Central air: make
Type and size ducts
❑ cooling tower: ❑ electric; ❑ gas.
❑ Window units: make ; number of units
❑ Evaporator cooler: make ; number of units _
Other
24. ELECTRIC WIRING:
B.T.U. capacity
Service: ❑ overhead; ® underground. Panel: ❑ fuse box: ® circuit -breaker; make
Wiring: ❑ conduit: ❑ armored cable; ❑ nonmetallic cable; ❑ Knob and tube: ❑ Other
Special outlets: ❑ range; ❑ water heater; ❑ other
® Doorbell, ® chimes, Push-button locations Additional Information:
B.T.U. capacity of each unit
cu. 1i. rating
AMP's No. circuits
LIGHTING FIXTURES:
Total number of fixtures Total allowance for fixtures, typical installation. $ $1200.00
Non -typical installation
Additional information: per plan
25. INSULATION:
Location
Thickness
Material, Type, and Method of Installation
Vapor Barrier
Roof
R-19
Ceiling
R-30
Wall
R-13
Floor
HARDWARE: (make, material, finish, or allowance.) 800.00
SPECIAL EQUIPMENT: (State material or make, model and quantity. Do not include items which, by established custom, are supplied by
occupant and removed when he vacates premises or chattels prohibited by law from becoming reality.) allow:$1,200.00
Built-in range and oven ❑ ; make
Model
Built-in refrigerator ❑ ; make
Cu. Ft.
Ice Maker ❑ : make
Model
Garbage disposal ❑ ; make
Model
Dishwasher ❑ ; make
Model
Venthood
Model
Other:
26. MISCELLANEOUS: (Describe any main dwelling materials, equipment, or construction items not shown elsewhere: or use to provide additional
information where the space provided was inadequate. Always reference by item number to correspond to numbering used on this form.)
Sprinkler yard allow $1,600.00
Grass & plants allow $2,000.00
Cedar fence back & side w/one gate
PORCHES:
per plan
TERRACES:
GARAGES:
per blan
WALKS AND DRIVEWAYS: per plot plan
Driveway: width ;base material ; thickness "; surfacing material ; thickness
Front walk: width ; material ; thickness ; Service walk: width ; material ; thickness
Steps: Material
OTHER ONSITE IMPROVEMENTS:
(Specify all exterior onsite improvements not described elsewhere, including items such as unusual grading, drainage structures, retaining walls,
fence, railings, and accessory structures.)
LANDSCAPING, PLANTING, AND FINISH GRADING:
Topsoil " thick: ® front yard; ® side yards; ® rear yard to feet behind main building.
Lawns (seeded, sodded, or sprigged): ® front yard sodded : ® side yards sodded ; ® rear yard sodded
Planting: ❑ as specified and shown on drawings; ❑ as follows:
Shade Trees, deciduous, " caliper. Evergreen trees: to B & B
Low flowering trees, deciduous, to Evergreen shrubs: to B & B
Hi -growing shrubs, deciduous, to Vines, 2-year
Medium -growing shrubs, deciduous, to
Low -growing shrubs, deciduous, to
IDENTIFICATION. This exhibit shall be identified by the signature of the builder and mortgagor.
Date July 3, 2003 Signatu
Contract Price $169,900.00 Signatu
Contractor or Builder
Land Owner
ENE GODS SPECFCAiIONS
GROSS WALL SQ. FT.: 1,868.3113 PERCENTAGE OF FENESTRATION
FENESTRATION SQ. FT.: 240.9111 TO WALL RATIO: 12.9%
IN ACCORDANCE WITH CHAPTER 5 OF THE INTERNATIONAL ENERGY
CONSERVATION CODE, AND BASED ON THE PRESCRIPTIVE BUILDING
ENVELOPE REQUIREMENTS FOR THE BRYAN/COLLEGE STATION AREA,
THE FOLLOWING SPECIFICATIONS WILL APPLY:
TABLE 502.2.4(3), MAX 15% RATIO
MAXIMUM GLAZING U FACTOR: 0.75
MINIMUM EXTERIOR WALL R—VALUE: R-13
MINIMUM CEILING R—VALUE: R-2(o
MINIMUM HVAC SEER VALUE: 10 SEER s
ENERGY CODE SPECS CALCULATED FOR:
DUSTY PHILLIPS CONSTRUCTION
DATED: 06/20/03
i
ol SITE PLAN 0
renesw�eo ►ioru sw a 1•-W-o' Mom
INaNk
-Pbo,
LOT s 91
BLOCKi 02
SUBDIVISIONt
CASTLEGATE
SECTION 10
COLLEGE STATION, TEXAS
BRAZOS COUNTY
COLCHESTER
,- . COURT
PROPERTY LINE,
L - 97.07'
B - N 6I'41'01' W
R - 50.0'
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00002184
Date 8/05/03
Property Address . . .
. . . 4211 COLCHESTER CT
Property ID
184200-1002-0910
R # . . . . . . . .
R*****
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . CASTLEGATE SEC 10
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . PLANNED DEVL HOUSING
Application valuation .
. . . 169900
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD DUSTY PHILLIPS CONSTRUCTION
4490 CASTLEGATE DR
DUSTY PHILLIPS
COLLEGE STATION TX
778453388 4490 CASTLEGATE
DRIVE
COLLEGE STATION
TX 77845
(979) 229-4850
------ Structure Information
SINGLE FAMILY
-----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
HEATED AREA
1843.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
SERIAL ZONES
249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . KE
Permit Fee . . . .
670.00 Plan Check Fee
.00
Issue Date . . . .
8/05/03 Valuation . .
. . 169900
Expiration Date . .
2/02/04
Qty Unit Charge Per Extension
BASE FEE 460.00
70.00 3.0000 THOU BLDG, VAL 100001-500000 210.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number
03-00002184
Page 2
Date 8/05/03
Special Notes and Comments
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR (S)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS-18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . .
. . . . . . SEWER TAP
4" CITY INSTALL
350.00
WATER TAP
3/4" CITY INSTL
400.00
Fee summary
Charged Paid
--------------------
Credited
--------------------
Due
-----------------
Permit Fee Total
670.00 670.00
.00
.00
Plan Check Total
.00 .00
.00
.00
Other Fee Total
750.00 750.00
.00
.00
BUILDING DEPT EPRESENTATIVE:
APPLICANT: �1 �%
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 3
Application Number . . . . . 03-00002184 Date 8/05/03
Grand Total 1420.00 1420.00 .00 .00
BUILDING DEPT EPRESENTATIVE :
AP PL I CANT :141�71-414�
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . .
Property Address . . . .
Property ID
R # .
Application description .
Subdivision Name . . . .
Property Use . . . . . .
Property Zoning . . . . .
Application valuation . .
03-00002185
4211 COLCHESTER CT
184200-1002-0910
. R*****
TEMP POLE
CASTLEGATE SEC 10
RESIDENTIAL
PLANNED DEVL HOUSING
0
Date 8/05/03
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
DUSTY PHILLIPS CONSTRUCTION
4490 CASTLEGATE DR
DUSTY PHILLIPS
COLLEGE STATION
TX 778453388
4490 CASTLEGATE DRIVE
COLLEGE STATION
TX 77845
(979) 229 -4 850
----------------------------------------------------------------------------
Permit . . . . . .
TEMP POLE
PERMIT
Additional desc . .
KE
Permit Fee . . . .
20.00
Issue Date . . .
. 8/05/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT: Lxx:741��-