HomeMy WebLinkAboutRES2003-02178WFJIJJR CITY OF COLLEGE STATION
Request number . . . . WF0426072 Open
4" SEWER AND 3/4" WATER
Facility ID . . . . . .
From node/to node . .
Customer ID . . . . . .
LM location ID . . . . .
General location . . . .
Requestor . . . . . . .
Requesting department
Request date/time . . .
Scheduled start date . .
Actual . . . . . . .
Requested completion .
Scheduled . . . . . .
Actual . . . . . . .
Close date . . . . . .
0 / 0
0
191080 2011 RAVENSTONE LOOP
CS COLLEGE STATION
HUSFELD HOMES (696-4369)
DEBI DE -BUILDING INSPECTION
July 10 2003 / 12:03:04
July 10 2003
July 10 2003
F3=Exit F5=More detail F7=AR customer F8=Contact F9=Charges
F10=Comments F12=Cancel F20=Customer functions F24=More keys
7/ 10/ 03
12:22:02
More...
.-C.ITY .OF ,COLLEGE STATI,
-,� 1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00002178
Date 7/10/03
Property Address . . .
. . . 2011 RAVENSTONE LOOP
Property ID
184200-0102-0460
R #
R109215
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . CASTLEGATE SEC 1
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . PLANNED DEVL HOUSING
Application valuation .
. . . 150000
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD HUSFELD HOMES INC
4490 CASTLEGATE DR
DENNIS HUSFELD
COLLEGE STATION TX
778453388 3204 LONGMIRE
COLLEGE STATION
TX 77845
(979) 696-4369
------ Structure Information
SINGLE FAMILY
-----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2943.00
INTERIOR WALL TYPE
1/2 SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
SERIAL ZONES
249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . LL
Permit Fee . . . .
610.00 Plan Check Fee
.00
Issue Date . . . .
7/10/03 Valuation . .
. . 150000
Expiration Date . .
1/07/04
Qty Unit Charge Per Extension
BASE FEE 460.00
50.00 3.0000 THOU BLDG, VAL 100001-500000 150.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
-
---------------------------------------------------- - --------------------
BUILDING DEPT rk
REP:
APPLICANT: l'�" \,
BUILDING PERMIT
CITY OF COLLEGE STATI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 03-00002178 Date 7/10/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR (S)
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
CITY INSTALL
350.00
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
Charged
Paid
Credited
--------------------
Due
-----------------
Permit Fee Total
----------
610.00
----------
610.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1360.00
1360.00
.00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT: ( V 11 �'
TEMPORARY POLE PERMI'v
CITY OF COLLEGE STATI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . .
Property Address . . . .
Property ID . . . . . . .
Application description .
Subdivision Name . . . .
Property Use . . . . . .
Property Zoning . . . . .
Application valuation . .
. 03-00002179
. 2011 RAVENSTONE LOOP
. 184200-0102-0460
TEMP POLE
CASTLEGATE SEC 1
RESIDENTIAL
PLANNED DEVL HOUSING
0
Date 7/10/03
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS LTD
------------------------
HUSFELD HOMES INC
4490 CASTLEGATE DR
DENNIS HUSFELD
COLLEGE STATION
TX 778453388
3204 LONGMIRE
COLLEGE STATION
TX 77845
(979) 696-4369
----------------------------------------------------------------------------
Permit . . . . .
. TEMP POLE
PERMIT
Additional desc . .
LL
Permit Fee . . . .
20.00
Issue Date . . . .
7/10/03
Valuation . . .
. 0
----------------------------------------------------------------------------
Other Fees . . . .
. . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary
Charged
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
----------
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT: (-� L
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.0 (.COLLEGE-STATION.TX. US
�Fa OTice UsON
DATE:
APPLICATION # 0 �_0� I
TEMP POLE # �� I
ADDRESS/LOCATION: 00d
LOTq� BLOCK a SUBDIVISION (ii��/F/� SEC/PH
BUSINESS/OWNER NAME: //(r PHONE: /,p
CONTRACTOR/HOMEOWNER: flasF&� (�65 PHONE: %L� q36R
CONTRACTOR ADDRESS: .32-cy %Lftre 47*7-ce7i l x
ELECTRICIAN: PLUMBER: j9P47V_S
HVAC: �l�%i9tti'iiLT GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION WVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK: /JFA.-3 C�`r�
STRUCTURE USE: R-05[ o epx-g-
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ )�,�n : TOTAL AREA: Zclti'1 HEATED AREA: 21'6-2-
(Cost of Labor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
F��S<EwFTAP: q
G/ INTERIOR WALL TYPE: ��2EfU%/�dtAC
SIZ It
WATER TAP: 3 EXTERIOR WALL TYPE:
SIZE
❑ OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE
ATTACHED
SIGNATURE OF APPLICANT:
FOUNDATION TYPE: rjLtAtq C-7-,j
ROOF TYPE: �� -((L Co-vp
OUBLE �RIPLE a
DETACHED a CARPORT a
Official Use Only
Plans Examiner
Zoning Official
mentS.
YES r NO
Energy Code Compliance Information
% Glazing of exterior walls - 13.9
Insulation R value of exterior walls k 3
Insulation R value of ceiling 1 (flat areas) 3 0
Insulation R value of ceiling 2 (vaulted areas/no attic) 101
Glazing SHGC i U7
Glazing U-Factor -2 1
R value of ductwork (;e
A/C SEER rating (, Z
Permft Number
MECcheck Compliance Report Checked By/Date
2000 IECC
MECcheck Software Version 3.3 Release lb
Data filename: C:\Pro$ram Fiies\Check\MECcheck12011 Ravenstone.cck
TITLE: 2011 Ravenstone
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: ,07/07/03
DATE OF PLANS: 7/7/03
COMPANY INFORMATION:
Husfeld Homes, Inc.
COMPLIANCE: Passes
Maximum UA = 6312
Your Home = 3678
41.7% Better Than Code
Gross
Glazing
Area or
Cavity
Pont,
or Door
Perim
R-Value
-Value
U-Factor
UA
Ceiling: Flat Ceiling or Scissor Truss
2182
0.0
30.-0
68
Walls; Wood Frame, }6" o.c.
17456
13.0
3.6
1181
Windows: Metal Frame, Double Pane with Low-E
281
0.490
138
Front Door: Solid
20
0.310
6
Back/Garage: Solid
36
0.310
11
Slab: Unheated Slab -On -Grade, -0.0' insui.
2182
0.0
2274
Furnace: Forced Hot Air, 78 AFUE
Air Conditioner: Electric Central Air, 12 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed to meet the 2000 IECC requirements in MECcheck Version 3.3 Release lb and to comply with the
m$ndatery requires 4istod in the MECcheck lnspection Checklist:
Builder/Designer Date
W
MECcheck Inspection Checklist
2000 JECC
MECcheck Software Version 3.3 Release lb
DATE: 07/07/03
TITLE: 2011 Ravenstone
Bldg. {
Dept. {
Use I
Ceilings:
[ ] { 1. Ceiling: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
{
Above-Gra#e Walls:
[ ] I 1. Walls: Wood Frame, 16" o.c., R-13.0 cavity + R-3.6 continuous insulation
I Comments:
{ Windows:
[ l { 1. Windows: Metal Frame, Double Pane 'Low-£, U-€aetor: -0.490
For widows without labeled U-factors, describe features;
{ # Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
I
Doors:
1. Front Door: Solid, U-factor: 0.310
Comments;
2. Back/Garage: Solid, U-factor: 0.310
Comments:
Floors:
1. Slab: Unheated Slab -On -Grade, R-0 (uninsulated)
Comments:
{ Heating and Cooling Equipment:
1. Furnace: Forced Hot Air, 78 AFUE or higher
Make and Model Number
{ 2. Air Conditioner: Electric Central Air, 12 SEER or higher
I Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakages
Joints, penetfations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be Type IC rated and installed with no penetrations, or Type IC or non -IC
rated installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible
materials and 3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions
[ ] I Materials and.equipment must be identified so that compliance can be determined.
[ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
I equipment mpst be provided.
[ ] I Insulation R values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
I the building plans or specifications.
I
{ Duct Insulation:
[ ] I Ducts in uncpnditioned spaces must be insulated to R-5,
I Ducts outside the building must be insulated to R-8.0.
I
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Cpntinuously welded and locking -type longitudinal joints and seams on ducts
I operating at Jess than 2 in. w.g. (500 Pa).
[ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] { The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to
I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
Service Water Heating:
[ ] I Water heatefs with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
I water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Circulating Hot Water Systems:
[ ] { Insulate circulating -hot water pipes to the levels in Table 1.
I
I Swimming l?ools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
I of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
Heating andCoolingPiping Insuladw.
[ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness
in Inches by Pipe
Sizes
Heated Water
Non -Circulating
Runouts
Circulating_
Mains and Runouts
Temperature ( F)
Up to 1„
Un to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
10
140-160
0.5
0.5
1.0
1.5
100-13Q
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Ran e F 2" Runouts 1" and Less 1.25" to 2" 2.5, to 4„
Heating Systems
Low Pressure./Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
OS
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Colall")
wu ,af ') ." .OU G�w sy-M cKX71 gNO-LGN3AVM IIOZ L °>,Dmig aZ - �1 '37`�
i D ff(-n—m a 11 USA I['13IGVHc! 'I N01173s1[ W °10-7 NVd IIIS
a b '� O6 �°'� ,�", � , 31793'119v7 now J,
ise't6