HomeMy WebLinkAboutRES2003-02176CITY OF COLLEGE STATION
WORK QUEST
PAGE
1
REQ/JOB:
WF0435278 / 001 PROJECT:
REQUEST DATE:
7/29/03
PRINT DATE:
7/29/03
CREW:
PRINT TIME:
7,1Q:01
SCHSTART:EDULEDA
LOCATION:
2009 RAVENSTONE LOOP
7 "2 /03
77845
COMPLETION:
7/29/03
GEN. LOC:
COLLEGE STATION LOC ID: 191082
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
HUSFELD HOMES, INC ORIGIN:
CUSTOMER -WALK
IN
USER ID:
SSTANLEY AUTH: SSTANLEY WORK TYPE:
ROUTINE
TEMP POLE
PASSED
TEMP POLE
PASSED
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID .
Assigned Department:
OT-CUSTOMER SERVICE
CITY OF COLLEGE STATION
WORT 'EQUEST
PAGE
1
REQ/JOB:
WF0426069 / 001 PROJECT:
REQUEST DATE:
7/10/03
PRINT DATE:
7/10/03
CREW:
PRINT TIME:
11:59:11
SCHEDULE
ES
LOCATION:
2009 RAVENSTONE LOOP
START:DAT7/10/03
77845
COMPLETION:
7/10/03
GEN. LOC:
COLLEGE STATION LOC ID: 191082
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
HUSFELD HOMES (696-4369) ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG WORK TYPE:
ROUTINE
4" SEWER
AND 3/4" WATER
4" SEWER
AND 3/4" WATER
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID .
Assigned Department:
OT-CUSTOMER SERVICE
BUILDING PERMIT
!p �;; COLLEGE __STATI(
1101 EXAS AVE'-'-
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00002176
Date 7/10/03
Property Address . . .
. . . 2009 RAVENSTONE LOOP
Property ID
. . 184200-0102-0470
R # . . . . . . . . . .
. . . R109216
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . CASTLEGATE SEC 1
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . PLANNED DEVL HOUSING
Application valuation .
. . . 150000
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD HUSFELD HOMES INC
4490 CASTLEGATE DR
DENNIS HUSFELD
COLLEGE STATION TX
778453388 3204 LONGMIRE
COLLEGE STATION
TX 77845
(979) 696-4369
------ Structure Information
SINGLE FAMILY
-----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
2025.00
INTERIOR WALL TYPE
1/2 SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
4.00
SEWER TYPE
PUBLIC
SERIAL ZONES
249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . LL
Permit Fee . . . .
610.00 Plan Check Fee
.00
Issue Date . . . .
7/10/03 Valuation . .
. . 150000
Expiration Date . .
1/07/04
Qty Unit Charge Per Extension
BASE FEE 460.00
50.00 3.0000 THOU BLDG, VAL 100001-500000 150.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
BUILDING DEPT REEPRESENTATIVE:
APPLICANT: 0
BUILDING PERMIT
CITY OF COLLEGE STATI,
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 03-00002176 Date 7/10/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged Paid Credited Due
---------------------------------------------------------
Permit Fee Total 610.00 610.00 .00 .00
Plan Check Total .00 .00 .00 .00
Other Fee Total 750.00 750.00 .00 .00
Grand Total 1360.00 1360.00 .00 .00
-
--------------------------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: ( t"-
BUILDING PERMIT
CITY OF COLLEGE STATI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00002176
BUILDING DEPT REPRESENTATIVE: /
o
APPLICANT:
Page 3
Date 7/10/03
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATI,
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . .
Property Address . . . .
Property ID
R # .
Application description
Subdivision Name . . . .
Property Use . . . . . .
Property Zoning . . . . .
Application valuation . .
03-00002177
2009 RAVENSTONE LOOP
184200-0102-0470
R109216
TEMP POLE
CASTLEGATE SEC 1
RESIDENTIAL
PLANNED DEVL HOUSING
0
Date 7/10/03
Owner Contractor
------------------------ ------------------------
GREENS PRAIRIE INVESTORS LTD HUSFELD HOMES INC
4490 CASTLEGATE DR DENNIS HUSFELD
COLLEGE STATION TX 778453388 3204 LONGMIRE
COLLEGE STATION TX 77845
(979) 696-4369
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . LL
Permit Fee . . . . 20.00
Issue Date . . . . 7/10/03 Valuation . . . . 0
----------------------------------------------------------------------------
Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00
Fee summary
-----------------
Permit Fee Total
Other Fee Total
Grand Total
Charged Paid
--------------------
20.00 20.00
45.00 45.00
65.00 65.00
Credited Due
--------------------
.00 .00
.00 .00
.00 .00
-- --'-------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: C��\\6' r
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W WW.CI.COLLEGE-STATION.TX.US
office Use only ---
DATE: it 01J1 -10-3
APPLICATION # ® I
TEMP POLE #
ADDRESS/LOCATION: L� AVCM6Tor� (gyp
LOT? BLOCK Z- SUBDIVISION SEC/PH
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: ` 5r-5u_) ArvwES / PHONE: (� q& — q3&5
CONTRACTOR ADDRESS: 32-0q LCTJGPh19f-__ 1 c, Cat ma Z T"P, /, `l s
ELECTRICIAN: G v j
HVAC: 61 e& e—fer
PLUMBER: (3j2,I.AT`wS
GOOD CENTS (Residential only): t/
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION Y_PvSHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL
Req)
DESCRIPTION OF WORK: R101AJ 6-Cr-157X.1T10_1"J
STRUCTURE USE: e—fe't1s
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) P JECT REGISTRATION# EABPRJ
SIZE
ROOF TYPE: 3i� y� Cxs
GARAGE TYPE: SINGLE a DETACHED � CARPORT a OUBLE � TRIPLE El
ATTACHED
VALUATION: $ / -,�`D ,CT� yTOTAL AREA: 7
ZqY�
HEATED AREA: ZOzS
(Cost of Labor and Materials)
PUBLIC SEWER
NUMBER OF BEDROOMS:
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
r(
SEWER TAP: G/
INTERIOR WALL TYPE:
l/
SIZE
WATER TAP: 3I�r /(
EXTERIOR WALL TYPE:
SIZE
SIGNATURE OF APPLICANT:
Official Use Only
C N111103
Plans Examiner
Zoning Official
ments.
YES r NO
Energy Code Compliance Information
% Glazing of exterior walls - I c,I,Gj
Insulation R value of exterior walls 0�
Insulation R value of ceiling 1 (flat areas) �D
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork 6
A/C SEER rating it
i
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.3 Release lb
Data filename: C:\Pro$ram Files\Check\MECcheck\2009 Ravenstone.cck
TITLE: 2009 Ravenstpne
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: D7/07/03
DATE OF PLANS: 7/7/03
COMPANY INFORMATION:
Husfeld Homes, Inc.
COMPLIANCE: Passes
Maximum UA = 3889
Your Home = 1677
56.9% Better Than Code
Ceiling: Flat Ceiling or Scissor Truss
Wall: Wood Frame, 10" o.c.
Window: Metal Framg, Double Pane with Low-E
Front Door: Solid
Back/Garage Door: Solid
Floor: Unheated Slab -On -Grade, 0.0' insul.
Air Conditioner_ 1: Eloctric Central Air, 12 SEER
Furnace 1: Forced Hot Air, 78 AFUE
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
P rimet
R-Value
-Value
U-Fa or
UA
2025
30.0
0.0
71
16192
13.0
3.6
1094
299
0.790
236
20
0.310
6
18
0.310
6
253
0.0
264
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed to meet the 2000 IECC requirements in MECcheck Version 3.3 Release lb and to comply with the
mandatory requirements -listed in the MECcheck inspection Cheeldist.
uilder/DesignCK�— -�DateBer
r
o
MECcheck Inspection Checklist
2000 �ECC
MECcheck Software Version 3.3 Release lb
DATE: 07/07/03
TITLE: 2009 Ravenstope
Bldg.
Dept. I
Use I
Ceilings:
[ ] I 1. Ceiling: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
I Comments:
1
Above -Graft Walls:
[ ] I 1. Wall: Wood Frame, 16" o.c., R-13.0 cavity + R-3.6 continuous insulation
I Comments: -
I
Windows:
[ ] I 1. Window: Metal Frame, Double Pane with Low E, U-factor: 0.790
I For windows without labeled U-factors, describe features:
I # Panes Frame Type Thermal Break? [ ] Yes [ ] No
I Comments:
I
Doors:
[ ] { 1. Front Door: Solid, U factor: 0.310
Comments:
[ ] I 2. Back/Garage Door: Solid, U-factor: 0.310
I Comments:
I Floors:
( ] I 1. Floor: Unheated Slab -On -tirade, R-0 .(uninsulated)
Comments:
I
Beating and Cooling Equipment:
[ ] I 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
I Make and Model Number
[ ] I 2. Furnace 1: Forced Hot Air, 78 AF[JE or higher
I Make pnd Model Number
I
Solar Heat Gain Coefficient:
( ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
I values must be determined in accordance with the NFRC test procedure or taken from the default table.
I
Air Leakagg:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] I Recessed lights must be Type IC rated and installed with no penetrations, or Type IC or non -IC
I rated installed inside an appropriate air -right assembly with a 0.5" clearance from combustible
materials and 3" clearance from insulation.
{
A-Uterials Identification:
[ ] I Materials and equipment must be installed in accordance with the manufacturer's installation instructions
I
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R values, glazing U-factors, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
I Duct Insulation:
[ ] I Ducts in unconditioned spaces must be insulated to R-5.
Ducts outsicg the building must be insulated to R-8.0.
I
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
I (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception. Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to
I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
I Service Watyr Reating:
[ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
Circulating Hot Water Systems:
[ ] j Insulate circulating hot water pipes to the levels in Table 1.
I Swimming )Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 200/a
I of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I ideating and CoofiWF4ft Insulatlea:
[ ] I HVAC piping conveying fluids above 105 'F or chilled fluids below 55 'F must be insulated to the
I levels in Table 2.
0-0 . .
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water Non -Circulating Runouts Circulating Mains and Runouts
Temperature (F) Up to III Up to 1.25" 1.5" to 2.0" Over 2"
170-180 0.5 1.0 1.5 2.0
140-160 0.5 0.5 1.0 1.5
100-130 0.5 0.5 0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Tvpes Range 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
73.56 ,
0
0
N
6/ol7b3