Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-02151
PREPARED 12/17/03, 12:21:19 INSPECTION TICKET PAGE 9 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/17/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 2086 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC 1 PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-1101-0030 APPL NUMBER: 03-00002151 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/16/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 7/17/03 AP 07/16/2003 09:05 AM LLONG ' SLAB GROUND BACK LEFT SIDE. STRINGS ON SETBACKS, OK. Bl__� 01 9/19/03 TB BLDG, FRAMING TIME: 17:00 9/22/03 AP 09/18/2003 01:18 PM GCARRILLO t ADD NAILS TO WINDBRACING ALONG REAR WALL ON MASTER BEDROOM AND CORNER OF KITCHEN. MAKE SURE EVERY CORNER GETS WINDBRACING. B130 01 9/24/03 TB BLDG, INSULATION TIME: 17:00 9/24/03 AP 09/24/2003 07:22 AM SSTANLEY B125 01 12/17/03 BLDG, FINAL TIME: 17:00 fz —1-7`8 3 12/17/2003 09:13 AM MALFORD 'N -------------------------------------- COMMENTS AND NOTES-------------------------------------- 4 L-Avili a)"�' f' JA f + c, ( t -J 09/19/2003 FRI 13:41 FAX 979 --- 0348 STYLECRAFT BUILDERS INC U 001/002 lJ1LDER5_ 11 FAX COVER SHEET DATE: 9 / l9 / 0 3 TO: S-ervi7<< 761�- 3M COMMENTS: Er PAGES: )' (Including cover) FROM: Eric Wivagg 4090 Highway 6 South College Station, Texas 77845 Phone: (979) 690-1222 ext. 20 Fax: (979) 690-0348 09/19/2003 FRI 13:41 FAX 979 P- 0348 STYLECRAFT BUILDERS INC 2 002/002 09/19/03 To Whom This May Concern: I'm am writing this letter on behalf of Styleeraft Builders, Inc, in order to inform you of a change on the Electrical permit of our job at 2086 Ravenstone. We originally listed Brazos Valley to do this project, and it has since been changed to College Station Electric. Please let me. know if there is anything further needed from me, and I am sorry for any inconvenience this may have caused. Thank you, Eric Wivagg Architectural Designer Stylecraft Builders, Tnc. CITY OF COLLEGE STATION WORK )UEST PAGE 1 REQ,/JOB: WF0429763 / 001 PROJECT: REQUESTPRINT DATE: 7%21%03 CREW: PRINT TIME: 7:59:46 SCHEDULE DATES' LOCATION: 2086 RAVENSTONE LOOP START: 03 77845 COMPLETION: 7%21%03 GEN. LOC: COLLEGE STATION LOC ID: 191026 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task cone: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE CITY OF COLLEGE STATION' $ WOR '.EQUEST PAGE 1 REQ/JOB: WF0425178 / 001 PROJECT: REQUEST DATE: 7/08/PRINT 03 CREW: PRINT TIME: 15:08:15 SCHSDART.DATT/08/03 LOCATION: 2086 RAVENSTONE LOOP 77845 COMPLETION: 7/08/03 GEN. LOC: COLLEGE STATION LOC ID: 191026 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BLDRS (690-1222) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE ... ,,BUILDING PERMIT _ g TY Ormrin =Icr 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002151 Date 7/07/03 Property Address . . . . . . 2086 RAVENSTONE LOOP Property ID 184200-0101-0030 R ## . . . . . . . R109172 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 140540 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS ------------------------ LTD STYLECRAFT BUILDERS 4490 CASTLEGATE DR RANDY FRENCH COLLEGE STATION TX 778453388 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE SIDING/MASONRY IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2129.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . LL Permit Fee . . . . 583.00 Plan Check Fee .00 Issue Date . . . . 7/07/03 Valuation . . . . 140540 Expiration Date . . 1/04/04 Qty Unit Charge Per Extension BASE FEE 460.00 41.00 3.0000 THOU BLDG, VAL 100001-500000 123.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIOP 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00002151 Page 2 Date 7/07/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIOT 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . 03-00002151 Date 7/07/03 Permit Fee Total 583.00 583.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1333.00 1333.00 .00 .00 - TEMPORARY POLE PERMIT CITY OF COLLEGE STATIOP' 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . Property Address . . . . Property ID . . . . . . . Application description . Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . Application valuation . . 03-00002152 2086 RAVENSTONE LOOP . 184200-0101-0030 . TEMP POLE CASTLEGATE SEC 1 RESIDENTIAL PLANNED DEVL HOUSING 0 Date 7/07/03 Owner Contractor ------------------------ GREENS PRAIRIE INVESTORS LTD ------------------------ STYLECRAFT BUILDERS 4490 CASTLEGATE DR RANDY FRENCH COLLEGE STATION TX 778453388 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . LL Permit Fee . . . . 20.00 Issue Date . . . . 7/07/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT:_ APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION ism 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX. US Fa OHke Use Only DATE: I '�l 3 APPLICATION # TEMP POLE # ADDRESS/LOCATION: Z_Un l U KU�I )e_/ )"� J ()) l SL 1 (;L) Y J LOT 3 BLOCK I SUBDIVISION PHASE BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Highway 6 South '�J r O ELECTRICIAN: Brazos Vallev Electric PLUMBER: Bass Plumbina HVAC: Control Temp GOOD CENTS (Residential only): No Ij�g CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Family Residence HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY� STANDARD (TAS) PROJECT REGISTRATION# EABPRJ N/A VALUATION: $ 1 q01514, oo TOTAL AREA: HEATED AREA: (Cost of Labor and Materials) ❑X PUBLIC SEWER SEPTIC/TREATMENT SYSTEM �X SEWER TAP: QX WATER TAP: ❑ OTHER TAP: �X TEMP POLE GARAGE TYPE 4" SIZE 9/ n SIZE SIZE SINGLE ATTACHED FX NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: Sheet Rock EXTERIOR WALL TYPE: Siding and/or Masonry FOUNDATION TYPE: Slab on Grade ROOF TYPE: Composition DOUBLE F—] TRIPLE DETACHED F__] CARPORT SIGNATURE OF APPLICANT: vuj For St lecraft Official Use Only Comments: 4tt_-� 3/45 YES or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls I -S % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: S:\ACAD\REScheck\2129-2086 Ravenstone.cck TITLE: Plan # 2129 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/02/03 DATE OF PLANS: 07-01-2003 PROJECT INFORMATION: Petty 2086 Ravenstone College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: Passes Maximum UA = 789 Your Home UA = 641 18.8% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 1: Solid Door 2: Glass SHGC: 0.40 Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Air Conditioner 2: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE a:� -5 Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1603 30.0 0.0 56 526 19.0 0.0 27 2060 13.0 0.0 144 249 0.670 167 38 0.500 19 18 0.440 8 211 0.0 220 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchecl and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer ( �—L) Date / G G REScheck Inspection Checklist 2000 IECC REScheckSoftware Version 3.5 Release la DATE: 07/02/03 TITLE: Plan # 2129 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.500 Comments: [ ] 2. Door 2: Glass, U-factor: 0.440 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) I Comments: Heating and Cooling Equipment: 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness forHVACPipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Add to Library Window Name Assembly Type Quantity Width x Height = Unit Area Total Area U-Factor SHGC Comments/ Description 1 3060 Twin Metal Frame, Do 2 6'-0" F-O" 36.00 72.00 ft2 0.670 2 3050 Twin Metal Frame, Do 1 6'-0" 5'-0" 30.00 30.00 ft2 0.670 3 1060 Metal Frame, Do 1 1'-0" 6'-0" 6.00 6.00 ft2 0.670 4 1 14416 Metal Frame, Do 1 4'-4" 1'-6" 6.50 6.50 ft2 0.670 5 1 11030 Metal Frame, Do 2 1'-0" 3'-0" 3.00 6.00 ft2 0.670 6 3030 Metal Frame, Do 1 T-0" 1 3'-0" 9.00 9.00 ft2 0.670 7 30 RT Metal Frame, Do 1 3'-0" 1'-6" 4.50 4.50 ft2 0.670 8 3060 Metal Frame, Do 4 3'-0" 6'-0" 18.00 72.00 ft2 0.670 9 3016 Metal Frame, Do 6 3'-0" 1'-6" 4.50 27.00 ft2 0.670 10 4040 Metal Frame, Do 1 4'-0" 4'-0" 16.00 16.00 ft2 0.670 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Window Area Total: 249.00 07/02/03 09:02:13 1/1 Area Calculator: Assembly Type Description Opaque door solid masonite Door Area Total: 55.56 07/02/03 09:02:14 1 /1 Area Calculator: ■ Assembly Type-� '©�0ffg�- M■Comments/Description © ..■�■ e Ceiling Area Total: 2129.00 07/02/03 09:02:14 1 /1 Area Calculator: -Assembly Type .. Exterior Wall Area Total: 2060.17 07/02/03 09:02:15 1/1 Area Calculator: Assembly Type :MIMI M... ME ®■�■�� ®■�■�� m■�■�� ®■�■�� m■�■�� Floor Area Total: 0.00 07/02/03 09:02:15 1/1