Loading...
HomeMy WebLinkAboutRES2003-02143PREPARED 2/04/04, 12:09:53 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/04/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 314 AGATE DR SUBDIV: STONE FOREST PH 2 CONTRACTOR H L C HOMES LLC PHONE (979) 696-9049 OWNER JOHNSON INVESTMENTS INC PHONE PARCEL 585200-0205-0050 APPL NUMBER: 03-00002143 RESIDENTIAL, 1 UNIT DETACHED NEW - ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/10/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 7/10/03 AP 07/10/2003 09:38 AM LLONG NO FOLDER W/INSPECTION SLAB GROUND BACK LEFT SIDE STRINGS ON SETBACKS OKAY 3115 01 8/15/03 TB BLDG, FRAMING TIME: 17:00 8/15/03 AP 08/15/2003 09:58 AM SSTANLEY B130 01 8/19/03 TB BLDG, INSULATION TIME: 17:00 8/19/03 AP 08/19/2003 10:42 AM SSTANLEY B125 01 2/04/0 BLDG, FINAL TIME: 17:00 •` � 02/04/2004 12:01 PM SSTANLEY -------------------------------------- COMMENTS AND NOTES ------------------------------------ - tl 03.3�5 CITY OF COLLEGE STATION WORK REQUEST PAGE 1 REQ/JOB: WF0434925 / 001 PROJECT: REQUEST DATE: 7/28/03 PRINT DATE: 7/28/03 CREW: PRINT TIME: 14:24:10 DULE SCHSTARRT:DATE�.28/03 LOCATION: 314 AGATE DR 77845 COMPLETION: 7/28/03 GEN. LOC: COLLEGE STATION LOC ID: 195080 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: H L C HOMES, INC ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE NIT DIMGPEP 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 ---------------------------------------------------------------------------- FAX: (979)764-3496 Application Number . . . . . 03-00002143 Date 7/03/03 Property Address . . . . . . 314 AGATE DR Property ID . . 585200-0205-0050 R # . . . . . . . . . . . . . R112557 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . STONE FOREST PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 165000 Owner Contractor ------------------------ JOHNSON INVESTMENTS ------------------------ INC H L C HOMES LLC PO BOX 800 LEON COUCH COLEMAN TX 768340800 11990 OLD WELLBORN ROAD COLLEGE STATION TX 77845 (979) 696-9049 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2497.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.50 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 252.00 ---------------------------------------------------------------------------- Permit BUILDING PERMIT Additional desc SS Permit Fee . . . . 655.00 Plan Check Fee .00 Issue Date . . . . 7/03/03 Valuation . . . . 165000 Expiration Date . . 12/30/03 Qty Unit Charge Per Extension BASE FEE 460.00 65.00 3.0000 THOU BLDG, VAL 100001-500000 195.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) -------------------------------------------- ---- ---------------------- BUILDING DEPT R ENTATIVE: APPLICANT: t7W'7', C� BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 03-00002143 Page 2 Date 7/03/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE Provide hearth in front of fireplace. TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 --------------------------i----------------------------------�--------------- BUILDING DEPT FAVRESENTATIVE: APPLICANT: 14 BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00002143 Date 7/03/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged Paid Credited Due -------------------- Permit Fee Total ---------- 655.00 ---------- 655.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1405.00 1405.00 .00 .00 ------------------- BUILDING DE APPLICANT: TEMPORARY POLE PERMIT © CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002144 Date 7/03/03 Property Address . . . . . . 314 AGATE DR Property ID . . . . . . . . . 585200-0205-0050 Application description . . . TEMP POLE Subdivision Name . . . . . . STONE FOREST PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ JOHNSON INVESTMENTS INC H L C HOMES LLC PO BOX 800 LEON COUCH COLEMAN TX 768340800 11990 OLD WELLBORN ROAD COLLEGE STATION TX 77845 (979) 696-9049 ---------------------------------------------------------------------------- Permit TEMP POLE PERMIT Additional desc SS Permit Fee . . . . 20.00 Issue Date . . . . 7/03/03 Valuation . . . . 0 Fee summary ----------------- Permit Fee Total Grand Total ------------------- BUILDING DE APPLICANT: Charged Paid -------------------- 20.00 20.00 20.00 20.00 Credited Due -------------------- .00 .00 .00 .00 CITY OF COLLEGE STATION WORK QUEST PAGE 1 REQ/JOB: WF0424013 / 001 PROJECT: REQUEST DATE: 7/03/PRINT 03 CREW: PRINT TIME: 10:41:18 SCHSTART.DATT/03/03 LOCATION: 314 AGATE DR 77845 COMPLETION: 7/03/03 GEN. LOC: COLLEGE STATION LOC ID: 195080 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: H L C HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 3/4" WATER 4" SEWER 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEk9-SfATIO N.TX.US For Office Use OWy DATE: ;7-021-0 APPLICATION # /Qf 2�'_0-(�- TEMP POLE # v /- 0- ( t ADDRESS/LOCATION: ci __1 t-1,0h It-, �r%JV-, �'C — LOT L5- BLOCK 5 SUBDIVISION 5 10"D6 pcge- < SEC/PH BUSINESS/OWNER NAME: \A � � c C / � PHONE:�`tJIO '9 CONTRACTOR/HOMEOWNER. ( � `� �`)(AC PHONE: CONTRACTOR ADDRESS: l�l 9 O L"'�� ELECTRICIAN: 11A >/ PLUMBER: MC(zLk & , HVAC: r00l2Cp_ IgA) GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: �' (� ©yy'►C STRUCTURE USE: Pi)E QAD . HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR. VALUATION: $ I C015, Doo TOTAL AREA: 3, i i C® (Cost of Labor and Materials) PUBLIC SEWER SEPTIC/TREATMENT SYSTEM 0< SEWER TAP: ® WATER TAP: OTHER TAP: `SIZE I SIZE NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: HEATED AREA: WE �/' �1 Mp —J SIZE TEMP POLE ROOF TYPE:14 GARAGE TYPE: SINGLE E] DOUBLE TRIPLE a / ATTACHED tK] DETAC D C RT SIGNATURE OF APPLICANT: Official Use Only Comments: YES or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating RB l� MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb TITLE: 314 Agate CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/01/03 DATE OF PLANS: July 1, 2003 COMPANY INFORMATION: IILC Homes, Inc. 11990 Old Wellborn Rd. Suite #3 College Station, Texas 77845 COMPLIANCE: Passes Maximum UA = 798 Your Home = 601 24.7% Better Than Code 0 � Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2497 0.0 30.0 77 ^- Wall 1: Wood Frame, 16" o.c. r 3416 0.0 13.0 293 Window 1: Metal Frame with Thermal Break, Double Pane — 337 0.640 216 Door 1: Glass 24 0.640 15 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations sub 'fled with �:= Ion. The proposed building has been designed to meet the 2000 IECC ements in 3.2 Release lb. Date i MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 07/01 /03 TITLE: 314 Agate Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 continuous insulation Comments: Windows: [ ] 1. Window 1: Metal Frame with Thermal Break, Double Pane, U-factor: 0.640 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Glass, U-factor: 0.640 # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -right assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordint to the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R-values and glazing U-values must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts l" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 L5 1.5 NOTES TO FIELD (Building Department Use Only)