HomeMy WebLinkAboutRES2003-02135PREPARED 1/14/04, 7:27:39 INSPECTION TICKET PAGE 4
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/14/04
------------------------------------------------------------------------------------------------
ADDRESS . : 1110 COEBURN CT SUBDIV: ALEXANDRIA PH 5
CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266
OWNER ED FROEHLING BUILDER INC PHONE
PARCEL 106500-0505-0620
APPL NUMBER: 03-00002135 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/15/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
8/15/03 AP 08/15/2003 10:21 AM KELMENDORF
set backs per strings, slab ground at back right
B115 01 9/26/03 CH BLDG, FRAMING TIME: 17:00
10/01/03 AP 10/02/2003 06:57 AM MALFORD
4 fill holes in sheetrock around fireplace flue
B130 01 10/24/03 OC BLDG, INSULATION TIME: 17:00
10/24/03 AP 10/23/2003 04:11 PM SSTANLEY
B125 01 1/14/04 BI BLDG, FINAL TIME: 17:00
01/13/2p04 01:45 PM GCARRILLO
- �-=--------------------------------- COMMENTS AND NOTES------------------------------------
BUILDING PERMIT r
MIPWCITY OF'AOLL'EGE STATIr
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
Property Address . . .
Property ID
R## . . . . . . . . . .
Application description
Subdivision Name . . .
Property Use . . . . .
Property Zoning . . . .
Application valuation .
. . . 03-00002135 Date 7/15/03
. . . 1110 COEBURN CT
. . 106500-0505-0620
. . . R114166
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
. . . ALEXANDRIA PH 5
. . . RESIDENTIAL
. . . SINGLE FAMILY RESIDENTIAL
. . . 111210
Owner Contractor
ED FROEHLING BUILDER INC ED FROEHLING BUILDERS
3887 HIGH LONESOME ED FROEHLING
COLLEGE STATION TX 778459443 3887 HIGH LONESOME RD
COLLEGE STATION TX 77845
(979) 776-8266
------ Structure Information SFR
-----
Construction Type .
. . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . .
. . . . RESIDENTIAL-SFR/DUPLEX
Other struct info .
. . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
HEATED AREA
1685.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
SERIAL ZONES
248.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
LL/DANA
Permit Fee . . . .
496.00 Plan Check Fee
.00
Issue Date . . . .
7/15/03 Valuation . .
. . 111210
Expiration Date . .
1/12/04
Qty Unit Charge Per Extension
BASE FEE 460.00
12.00 3.0000 THOU BLDG, VAL 100001-500000 36.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL E UIPMENT
BUILDING DEPT REPRESENTATIVE:
APPLICANT: 37�/ jy_z_, _
BUILDING PERMIT
} CITY OF COLLEGE STATI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 2
Application Number . . . . . 03-00002135 Date 7/15/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
POST PERMIT CARD ON JOB SITE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary
-----------------
Charged
--------------------
Paid
Credited
--------------------
Due
Permit Fee Total
496.00
496.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1246.00
1246.00
.00
.00
BUILDING DEPT
REPRESENTATIVE:
APPLICANT:
'9&jlal,�
BUILDING PERMIT
CITY OF COLLEGE STATI
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00002135
BUILDING DEPT REPRESENTATIVE:
APPLICANT: /�,�
Page 3
Date 7/15/03
CITY OF COLLEGE STATION
WOR: EQUEST
PAGE
1
REQ/JOB:
WF0427706 / 001 PROJECT:
REQUEST DATE:PRINT
DATE:
7/15/03
CREW:
PRINT TIME:
11:44:57
SCHSTART.DATT/15/03
DULELOCATION:
1110 COEBURN CT
77845
COMPLETION:
7/15/03
GEN. LOC:
COLLEGE STATION LOC ID: 196482
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
ED FROEHLING BLDRS (776-8266) ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG WORK TYPE:
ROUTINE
4" SEWER AND 3/4" WATER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
4" SEWER
AND 3/4" WATER
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
SET UP NEW UTILITY ACCT SET
Facility
ID .
Assigned Department: OT-CUSTOMER SERVICE
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
E3 1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI. COLLEG E-STATI ON.TX. US
ADDRESS/LOCATION: 1110 4-0e t3L)Ac) r✓OU (z�%
LOT Z_ BLOCK S SUBDIVISION ,dL��I'
/ Fa Office Use,OgNyQ
DATE:
APPLICATION#
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: � j�lLoe�L�,✓4 v! (/PHONE: ��� •826�
CONTRACTOR ADDRESS: .5687 1114#1_414.?0 Sorl 95- Al)
ELECTRICIAN: ��-—GEGTjG PLUMBER:
HVAC: S�4& 5 GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK:
STRUCTURE USE: 51d41-E 10,4.N4/Ly
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR.,
VALUATION: $ 14Z r V TOTAL AREA: ZSI
(Cost of L6Wr and Materials)
rjl*,P,-UBLIC SEWER NUMBER OF BEDROOMS:
SEPTICITREATMENT SYSTEM NUMBER OF BATHROOMS:
R SEWER TAP:
WATER TAP:
OTHER TAP:
-1 to
SIZE
3 r1
S fZE
SIZE
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
HEATED AREA: 168.5
3
Z
s��'� rRoGK
,9W _4 8 oA) ,i:A D16
TEMP POLE ROOF TYPE: GOMPDS/T/O✓ 5#1-044 G 4
GARAGE TYPE: SINGLE a DOUBLE ® TRIPLE
ATTACHED a )DETACHED F-1 a CARPORT
/
SIGNATURE OF APPLICANT:
rr II Official Use Only
014,d�OJI� WoreNO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls Z .
Insulation R value of exterior walls 1�- I3
Insulation R value of ceiling 1 (flat areas) (Z_ 30
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor .(0
R value of ductwork �-
A/C SEER rating /D 5�A rZ
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lb
Data filename: C:\Program Files\Check\REScheck\I I IOCC.rck
TITLE: 1110 COEBURN COURT
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 06/28/03
DATE OF PLANS: JUNE 17, 2003
PROJECT INFORMATION:
SPEC HOME
COMPANY INFORMATION:
ED FROEHLING BUILDER, INC
COMPLIANCE: Passes
Maximum UA = 605
Your Home UA = 514
15.0% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.33
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Front
Projection factor: 0.19
Door I: Solid
Wall 2: Wood Frame, 16" o.c.
Window 2: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Left Side
Projection factor: 0.27
Wall 3: Wood Frame, 16" o.c.
Window 3: Metal Frame:Double Pane with Low-E
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Back
Projection factor: 0.23
Wall 4: Wood Frame, 16" o.c.
y - ,035
Permit Number
Checked By/Date
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
1685
30.0
0.0
59
428
15.0
0.0
27
44
0.600 26
38 0.400 15
383 15.0 0.0 29
1 0.600 1
418 15.0 0.0 27
68 0.600 41
383 15.0 0.0 22
Window 4: Metal Frame:Double Pane with Low-E 82 0.600 49
SHGC: 0.40
Bldg. faces 180 deg. from North; Comp. orient.: Right Side
Projection factor: 1.00
Door 2: Glass 18 0.580 10
SHGC: 0.78
Bldg. faces 180 deg. from North; Comp. orient.: Right Side
Projection factor: 0.81
Floor 1: Slab-On-Grade:Unheated 200 0.0 208
Insulation depth: 0.0'
Air Conditioner 1: Electric Central Air, 10 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in RES checkVersion 3.5 Release lb (formerly MECchec� and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer ��.� Date d3
CURVE Ti& F
CURVE DELTA RAOWs UDOTH yAN0ENT
c1 48'50'52' 50,00' 42AX 22.71'
G O'c vu p) Court J
50' ..0W.
Vol, 5063, Pg. 74 o IF
cl Scale: 1Now or Fumledy
• •• °w
J
N � \
Edward Frp*Wimq
Val. 2485. Pg. 201
Iva
'-Proposad
Now or Fora-w w Rdwi(fance \
Edworcf Fresh
i �1 \.
Vol. 2>a8Q Pq. 20t `7
m sa 6 2;
20' RUZ
Now or rm
Foerly
Edrard F"h jng Now pr'rOmwrly
Vol. 29aa. Pa. 201 Edward FroehMq Y1
o1. 29 20
31-76b05.dwp
de'i'CL Z1WEiVG1NEER1NG, /rR�C • 1B 6�ondcr►Rr�7rivQ Serit� 9r?3' Cv/tea SJbliar�, Texas TT • 09?`��
WO -r(--
��� ; 7AX5