Loading...
HomeMy WebLinkAboutRES2003-02127PREPARED 11/18/03, 12:02:51 INSPECTION TICKET PAGE 7 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/18/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 1033 WINDMEADOWS DR SUBDIV: WESTFIELD VILLAGE PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE PARCEL 650730-0101-0110 APPL NUMBER: 03-00002127 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/25/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 7/25/03 AP 07/24/2003 04:05 PM SSTANLEY SETBACKS STRINGS PULLED. SLAB GROUND BACK LEFT B7 01 9/22/03 CH BLDG, FRAMING TIME: 17:00 9/23/03 AP 09/22/2003 08:11 AM SSTANLEY NEED HANGERS IN MASTER BEDROOM WHERE BRACES MEET JOISTS. NEED REPAIR STRAP ON TOPPLATE @ GAS PIPE FOR FIREPLACE. B130 01 9/24/03 CH BLDG, INSULATION TIME: 17:00 ! 9/25/03 AP 09/24/2003 08:07 AM GCARRILLO B125 01 11/18/03 BI BLDG, FINAL TIME: 17:00 I((1g10 3 Y,n� p 0 C 11/18/2003 08:45 AM GCARRILLO -------------------------------------- COMMENTS AND NOTES --------------------------' c i 0Q Z rr,g2.i-io,- r ! City of College Station WORK 7QUEST PAGE 1 REQ/JOB: WF0450786 / U01 PROJECT: REQUEST DATE: 8/15/03 R PRINT DATE: 8/15/03 CREW: PRINT TIME: 14:25:25 ES LOCATION: 1033 WINDMEADOWS DR SCHEDULE START:DAT8/15/03 77845 COMPLETION: 8/15/03 GEN. LOC: COLLEGE STATION LOC ID: 195762 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE CITY OF COLLEGE STATION EQUEST =' PAGE 1 REQ/J OB: WF0425177 /�001 PROJECT: REQUEST DATE: 7/08/03 " PRINT DATE: 7/08/03 CREW: PRINT TIME: 15:05:43 SCHEDULE DATES LOCATION: 1033 WINDMEADOWS DR 03 77845 COMPLETION: 7/08/03 GEN. LOC: COLLEGE STATION LOC ID: 195762 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BLDRS (690-1222) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE �► 1L ING PERMIT 7 �CYE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002127 Date 7/07/03 Property Address . . . . . . 1033 WINDMEADOWS DR Property ID . . 650730-0101-0110 R # . . . . . . . . . . . . . R113292 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 99792 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1512.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . LL Permit Fee . . . . 460.00 Plan Check Fee .00 Issue Date . . . . 7/07/03 Valuation . . . . 99792 Expiration Date . . 1/04/04 Qty Unit Charge Per Extension BASE FEE 260.00 50.00 4.0000 THOU BLDG, VAL 50001-100000 200.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER(S) BUILDING DEPT REPRESENTATIVE: APPLICANT: 7 BUILDING PERMIT CITY OF COLLEGE STATIOI 110 e' TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00002127 Page 2 Date 7/07/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due BUILDING DEPT REPRESENTATIVE: 5�2� APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIOI 'f 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . Permit Fee Total 460.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1210.00 03-00002127 BUILDING DEPT REPRESENTATIVE: APPLICANT: �� 460.00 .00 .00 .00 750.00 .00 1210.00 .00 Page 3 Date 7/07/03 .00 .00 .00 .00 TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00002128 Date 7/07/03 Property Address . . . . . . 1033 WINDMEADOWS DR Property ID 650730-0101-0110 R # . . . . . . R113292 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVI, HOUSING Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . TEMP POLE PERMIT Additional desc . LL Permit Fee . . . . 20.00 Issue Date . . . . 7/07/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: 4�— Far Office Use Only APPLICATION FOR BUILDING PERMIT DATE: Y7- I-O CITY OF COLLEGE STATION APPLICATION # 3- eraid 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 TEMP POLE # 05 _91 oZ (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: l i)33 w i nd meadm S LOT Y BLOCK SUBDIVISION r CI ld 11 II(JLUC� PHASE BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 f.;. �0' CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20 �4VO CONTRACTOR ADDRESS: 4090 State Highway 6 South � ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing HVAC: Control Temp GOOD CENTS (Residential only): No CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Family Residence HOMEOWNER ASSOC IATI ON/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ NIA LIn VALUATION: $ vl q I r% l ooQ o 0— TOTAL AREA: 20M HEATED AREA: E (Cost of Labor and Materials) �X PUBLIC SEWER SEPTIC/TREATMENT SYSTEM �X SEWER TAP: XX WATER TAP: ❑ OTHER TAP: �X TEMP POLE GARAGE TYPE: 4" SIZE 3/4 ^ SIZE JIZE SINGLE ATTACHED EX SIGNATURE OF APPLICANT: a4 �� zh/ice Plans Examiner NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE FOUNDATION TYPE ROOF TYPE DOUBLE DETACHED a Official Use Only TRIPLE CARPORT Zoning Official Sheet Rock Siding and/or Masonry Slab on Grade Composition Co ents: - NO I Energy Code Compliance Information % Glazing of exterior walls /� % Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 L 1 f REScheck Compliance Certificate 2000 IECC RES check Software Version 3.5 Release lc Data filename: S:\ACAD\REScheck\1472-1514—Porch.eck TITLE: Plan #1472-1514 Front Porch Series CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 07/01 /03 DATE OF PLANS: 7/1/03 PROJECT INFORMATION: SPEC 1033 Windmeadows College Station, Texas COMPANY INFORMATION: Stylecraft Builders Inc. 4090 State Hwy. 6 South College Station, Texas 77845 COMPLIANCE: Passes `' Maximum UA = 609 Your Home UA = 520 ^I4 6% Better Than Code (UA) _] Maximum SHGC = 0.40 Your SHGC = 0.40 Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1392 30.0 0.0 49 Ceiling 2: Cathedral Ceiling (no attic) 356 19.0 0.0 19 Wall 1: Wood Frame, 16" o.c. 1464 13.0 0.0 99 Window 1: Metal Frame, Double Pane with Low-E 198 0.670 133 SHGC: 0.40 Door 1: Solid 38 0.500 19 } Door 2: Glass 18 0.580 10 SHGC: 0.40 Floor 1: S lab -On- Grade: Unheated 183 0.0 191 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 12 SEER Furnace 2: Forced Hot Air, 80 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release Ic (formerly MECchecl) and to comply with the mandatory requirements listed in the RES check Inspection Checklist. Builder/Designer ` REScheck Inspection Checklist 2000 IECC RES check Software Version 3.5 Release lc DATE: 07/01 /03 TITLE: Plan #1472-1514 Front Porch Series Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.500 Comments: 2. Door 2: Glass, U-factor: 0.580 Comments: Floors: 1. Floor 1: Slab -On -Grade: Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 2: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating I equipment must be provided. [ ] I Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly I marked on the building plans or specifications. I I Duct Insulation: [ ] I Ducts in unconditioned spaces must be insulated to R-5. I Ducts outside the building must be insulated to R-8.0. I I Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics I (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. I Exception: Continuously welded and locking -type longitudinal joints and seams on ducts I operating at less than 2 in. w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. I I Temperature Controls: [ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. I I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% 1 of the heating energy is from non-depletable sources. Pool pumps require a time clock. I I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ( F) 2" Runouts V and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Comments/ I Description Ian , , - O�■�■ • „ • „ ® , . , � �I-1 .., - Off■ . , ■ „ „ ® , . , �� Window Area Total: 215.00 07/01/03 08:24:56 1/1 Area Calculator: Assembly Type CO Description Door Area Total: 37.78 07/01 /03 08:24:58 1 /1 Area Calculator: Assembly Type Comments/Description Mflat Ceilinor Scissor Tru s ©Cathedral.attic) ■�■ Ceiling Area Total: 1509.00 07/01/03 08:24:59 1/1 Area Calculator: AssemblyType Comments/Description Exterior Wall Area Total: 1456.00 07/01/03 08:25:00 1/1 Area Calculator: Comments/Description Floor Area Total: 0.00 07/01 /03 08:25:00 1 /1