HomeMy WebLinkAboutRES2003-02069PREPARED
4/15/04, 7:58:36
INSPECTION TICKET
PAGE 1
#ity of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 4/15/04
ADDRESS
. : 2047 RAVENSTONE LOOP SUBDIV: CASTLEGATE SEC
1 PH 2
CONTRACTOR T C CUSTOM HOMES
PHONE (%979) 774-1110
OWNER
GREENS PRAIRIE INVESTORS LTD PHONE
PARCEL
184200-2102-0230
APPL NUMBER: 03-00002069 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
7/24/03 TB
BLDG, FOUNDATION -SLAB TIME: 17:00
7/25/03 DP
07/24/2003 08:33 AM SSTANLEY
NO MAT STEEL, NOT READY.
B: 02
7/25/03 TB
BLDG, FOUNDATION -SLAB TIME: 17:00
7/25/03 AP
07/25/2003 09:21 AM SSTANLEY
terry to sign
STRINGS ON SETBACKS, OK. SLAB GROUND BACK
RT. SIDE.
B115 01
9/02/03 TB
BLDG, FRAMING TIME: 17:00
9/09/03 AP
09/02/2003 08:25 AM SSTANLEY
B125 01
4/15/04 BI
BLDG, FINAL TIME: 17:00
04/14/2004 03:53 PM MALFORD
-------------------------------------- COMMENTS AND NOTES--------------------------------------
L
CITY OF COLLEGE STATION
WOF REQUEST
PAGE
1
REQ/JOB:
WF0425175 / 001 PROJECT:
REQUEST DATE:
7/080PRINT
8/03
CREW:
PRINT TIME:
15:03:15
SCHEDULE
DATES
LOCATION:
2047 RAVENSTONE LOOP
03
77845
COMPLETION:
7/08/03
GEN. LOC:
COLLEGE STATION LOC ID: 193360
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
TC CUSTOM HOMES (693-7835 ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG — WORK TYPE:
ROUTINE
4" SEWER
AND 3/4" WATER
4" SEWER
AND 3/4" WATER
Category
code CS -CUSTOMER SERVICES CSCS
Task cone:
SET UP NEW UTILITY ACCT SET
Facility
ID
Assigned Department:
OT-CUSTOMER SERVICE
BUILDING PERMIT
CIT�Y OF STATIOY
3 "`
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00002069 Date 7/07/03
Property Address . . .
. . . 2047 RAVENSTONE LOOP
Property ID
184200-2102-0230
R # . . . . . .
R111204
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . CASTLEGATE SEC 1 PH 2
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . PLANNED DEVL HOUSING
Application valuation .
. . . 132594
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
------------------------
LTD T C CUSTOM HOMES
4490 CASTLEGATE DR
TODD CARNES
COLLEGE STATION TX
778453388 P 0 BOX 11092
COLLEGE STATION TX 77840
(979) 774-1110
-------------------------- Structure
Information -------------------------
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
a Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
+
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2009.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 249.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . LL
Permit Fee . . . .
559.00 Plan Check Fee .00
Issue Date . . . .
7/07/03 Valuation . . . . 132594
Expiration Date . .
1/04/04
Qty Unit Charge Per
Extension
BASE FEE 460.00
33.00 3.0000 THOU
BLDG, VAL 100001-500000 99.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT
SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE
PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER(S)
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
�• BUILDING PERMIT
CITY OF COLLEGE STATIOP
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Page 2
Application Number . . . . . 03-00002069 Date 7/07/03
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
PROVIDE,SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . . . . . . . .
Fee summary Charged
----------------- ----------
SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Paid Credited Due
---------- ---------- ----------
Permit Fee Total 559.00 559.00 .00 .00
Plan Check Total .00 .00 .00 .00
BUILDING DEPT RE(P�RESENTATIV,EE I
APPLICANT:yL—
BUILDING PERMIT
CITY OF COLLEGE STATIOP
1101 TEXAS AVE
14
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00002069
Other Fee Total 750.00 750.00
Grand Total 1309.00 1309.00
BUILDING DEPT
APPLICANT:
ESENTA;iIVE :
Page 3
Date 7/07/03
.00 .00
.00 .00
._� • TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . .
03-00002070
Date 7/07/03
Property Address . . .
. . .
2047 RAVENSTONE LOOP
Property ID . . . . . .
. . .
184200-2102-0230
Application description
. . .
TEMP POLE
Subdivision Name . . .
. . .
CASTLEGATE SEC 1 PH 2
Property Use . . . . .
. . .
RESIDENTIAL
Property Zoning . . . .
. . .
PLANNED DEVL HOUSING
Application valuation
0
Owner
Contractor
------------------------
GREENS PRAIRIE INVESTORS
LTD
------------------------
T C CUSTOM HOMES
4490 CASTLEGATE DR
TODD CARNES
COLLEGE STATION TX
778453388
P 0 BOX 11092
COLLEGE STATION
TX 77840
(979) 774-1110
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . LL
Permit Fee . . . .
20.00
Issue Date . . . .
7/07/03
Valuation . .
. . 0
----------------------------------------------------------------------------
Other Fees . . . . . .
. . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
Paid Credited
--------------------
Due
----------
---------------------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
--------------------------------------------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
Fp aror U- o,�
APPLICATION FOR BUILDING PERMIT DATE: I �l// f (/
CITY OF COLLEGE STATION APPLICAnON
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840 TEMP POLE # 0,3 - o / o
(979)_764-3570 (979) 764-3496 FAX
WWW.CI.COLLE P1STATION.TX.US:
ADDRESS/LOCATION:_ c�O�I1�,//Ra�ns�o�nR.
Cus c
LOT a3 le
BLOCK a SUBDIVISION
BUSINESS/OWNER NAME: CUKYiQS PHONE:
CONTRACTOR/HOMEOWNER: , C _ 5;1�ml HaynQ,S PHONE: UC13 -7%?jS
CONTRACTOR ADDRESS: 2w SpV{M s� Pkwq , CGL-sy
ELECTRICIAN: gt g -wc PLUMBER: CP. PW Wbti
HVAC: CY16YUux\ PCI C, GOOD CENTS (Residential only): S
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: V\AW Vy jw,
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:_
TEXAS ACCESSIBILITY STANDARD (TAS) PROJ T REGISTRATION# EABPRJ
VALUATION: $ I I Sri TOTAL AREA: a1y HEATED AREA: 2.uoq
(Cost oft1bor ana Materials)
PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
dSEWER TAP: t(
SIZE
dWATER TAP: 3
SIZE
OTHER TAP:
Eg/TEMP POLE
GARAGE TYPE:
SINGLE a
ATTACHED
SIGNATURE OF APPLICANT:
NUMBER,OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE
3
C
gR
ii V, C_Y-,
slab
ROOF TYPE:
DOUBLE [S?f TRIPLE a
IETACHED.-F] CARPORT a
Official Use Only
IJ nts:
,� YES r NO
Plans Examiner Zoning Official
Energy Code Compliance. Information
•n
/o
o �D
Glazing of exterior walls 1
Insulation R value of exterior walls �3
Insulation R value of ceiling 1 (flat areas) 3
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor tO�
R value of ductwork 12�
A/C SEER rating f 2-
s d
CASTLEGATE
t�
lw
ly
N
co
' IZ
i
i Ii
i_25" FRONT B.L.
sl
P.U.E.
LOT-23
BRICK
IW CON
BLK-2
MAIL -BOX
DRIVE
PH-2
SECA
RAVENSTONE
1 SITE PLAN
SCALIt
T.C. Mwr
Custom Homes R.A.I. A-1
PLAN# 2009A DRAFT DESIGN CONSULT M:
ONE
(979) 693-7835 (979) 690-3396 a�
02-25-03
4
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: plan #2009A
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 08/27/02
DATE OF PLANS: 08-26-02
COMPANY INFORMATION:
T.C. Custom Homes
(979)693-7835
NOTES:
This MecCheck report was generated by R.A.I.:
John Rhodes
P.O. Box 9389
College Station, Texas 77842
(979)412-5066
D -3 -9,06 C(
Permit Number
Checked By/Date
COMPLIANCE: Passes
Maximum UA = 778
Your Home = 677
13.0% Better Than Code
Gross
Glazing
Area or
Cavity
Cont.
or Door
Perimeter
R-Value
R-Value
U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss
1881
30.0
0.0
66
Ceiling 2: Cathedral Ceiling (no attic)
128
19.0
0.0
7
Wall 1: Wood Frame, 16" o.c.
1919
13.0
0.0
128
Window 1: Metal Frame, Double Pane with Low-E
287
0.670
192
Door 1: Solid
38
0.580
22
Door 2: Glass
36
0.500
18
Slab 1: Unheated, 0.0' insul.
234
0.0
244
Air Conditioner 1: Electric Central Air, 12 SEER
Furnace 1: Forced Hot Air, 80 AFUE
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been
designed to meet the 2000 ECC requirements in MECcheck Version 3.2 Release lb.
Builder/Designer Date Ir- a 6- 0,4,
,.v...r_.r. .._............�„1.._,.1... ..,a.......r7�c.:vr,....-,+N ...-.w,,,n,o.,w. .. - ...-... ,.... . w-.-:.ranowTv.a ::,cccat:.Ks.J�azc,�::.:t-�%.: •.. .•-= - --
0
MECcheck Inspection Checklist
2000.IECC
MECcheck Software Version 3.2 Release lb
DATE: 08/27/02
TITLE: plan #2009A
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
[ ] 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670
y For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Solid, U-factor: 0.580
Comments:
[ ] 2. Door 2: Glass, U-factor: 0.500
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Slab -On -Grade Floors:
[ ] 1. Slab l: Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
[ ] l . Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
[ ] 2. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
Materials Identification:
_.. .�.._�.. .. � --... --�.: __ ._._.r-w.,..v.:�14�[._.,......�_�_. -...____�__..:..:w.r_--.''�n.•Kf_ri*:G:!7�LNti?`r_�'iti�-Ir�rv.,r...-_. _.._
y,
Materials and equipment must be installed in accordant to the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R-values, glazing U-values, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
Cooling ducts with exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
.... _ .... __... _ _ ..._._ _.... .�-...�.,_n_,1 _...........�..�..._ ......... ._..- \..�....vr�.sr..r::t�?Li:r��i:1i2:'+4�I�•i�lY.etLS'i.rx'.:.-:C-.... �....� 1:�F:i
{
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Ding System Types
Ran e F
2" Runouts
V and Less
1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Area CalculatorMindows:tc2009a
Window Area Total: 287.13
08/27/02 09:59:48 1/1
Area Calculator:Doors:tc2009a
Door Area Total: 55.56
08/27/02 09:59:48 1/1
Area Calculator:Ceilings:tc2009a
Assembly Type
Comments/Description
Ceiling Area Total: 2009.00
08/27/02 09:59:49 1/1
Area Calculator:Walls:tc2009a
M
Assembly Type
Comments/D—
Exterior Wall Area Total: 1919.33
08/27/02 09:59:49 1/1
Area Calculator:Slab Floors:tc2009a
Assembly Type
Perimeter
Comments/Description
1
Unheated
234. 00
ft
2
0.00
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
_
20
21
22
23
24
25
26
Slab Area Total: 234.00
08/27/02 09:59:49 1/1