Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-02040
PREPARED llj20/03, 7:41:12 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/20/03 ---------- ----------------------------------------------------------------------------------- ADDRE!;S . : 2082 RAVENSTONE-LOOP SUBDIV: CASTLEGATE SEC 1 PH 1 CONTRACTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER GREENS PRAIRIE INVESTORS LTD PHONE PARCEL 184200-1101-0050 APPL NUMBER: 03-00002040 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 7/23/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00� 7/23/03 AP 07/22/2003 02:08 PM KELMENDORF SLAB GROUND BACK LEFT SIDE. STRINGS ON SETBACKS OK. B O1 9/17/03 TB BLDG, FRAMING TIME: 17:00 r 9/18/03 AP 09/17/2003 11:35 AM MALFORD JB 01 9/29/03 TB BLDG, INSULATION TIME: 17:00 'v 9/29/03 AP 09/29/2003 10:11 AM SSTANLEY _ B125 01 11/18/03 BI BLDG, FINAL TIME: 17:00 } 11/18/03 CA 11/18/2003 01:24 PM GCARRILLO 13125?02 11/20/03 BI BLDG, FINAL TIME: 17:00 01 11/20/2003 07:40 AM GCARRILLO ' ----I---------------------------------- COMMENTS AND NOTES -------------------------------------- ;t �` Lam,✓ ��%5� � 5��� � - r� ,r N°r I �� 141, CITY OF COLLEGE STATION -. WORF EEQUEST PAGE 1 REQ/JOB: WF0421862 / 001 PROJECT: REQUEST DATE: 6/26/03 PRINT DATE-: 6/26/03 CREW: PRINT TIME: 12:57:58 SCHEDULE DATES' LOCATION: 2082 RAVENSTONE LOOP 77845 COMPLETION: 6/26/03 GEN. LOC: COLLEGE STATION LOC ID: 191030 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING (776-8266) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE CITY OF COLLEGE STATION WORF E-QUEST �''� PAGE 1 WF0422108 / 001_ PROJECT: _ REQUEST DATE: 6/27/03 PRINT DATE: - -6/27/03 CREW: PRINT TIME: 9:16:11 SCHEDULE LOCATION: 2082 RAVENSTONE LOOP STTART:DATES 6/27/03 77845 COMPLETION: 6/27/03 GEN. LOC: COLLEGE STATION LOC ID: 191030 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING (776-8266) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: ------------------------------------------------------------------------------- OT-CUSTOMER SERVICE �� `'•, ILDING IJER iT OLLEGE STATION_ "COLLEGE' STATION,- TX 77840 PHONE': (979Y764-3570 FAX: (979) 764-34 96 Application Number . . Property Address . . Property ID . . . . . . . R# . . . . . . . . . . Application description . Subdivision Name . . . . Property Use . . . . . . Property Zoning . . . . . ,Application valuation . . 03-00002040 2082 RAVENSTONE LOOP 184200-0101-0050 R109174 RESIDENTIAL, 1 UNIT CASTLEGATE SEC 1 RESIDENTIAL PLANNED DEVL HOUSING 137544 Date 6/26/03 DETACHED NEW Contractor Owner ---------- -------------- _ _ GREENS PRAIRIE INVESTORS LTD BUILDERS 4490 CASTLEGATE DR ED FROEHLING TX 778453388 3887 HIGHLONESOME RDCOLLEGE COLLEGE STATION ATION TX 77845 (979) 776-8266 *Structure Information ------------------------- -------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) RESIDENTIAL-SFR/DUPLEX Occupancy Type . . . Other struct info . . . . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 2084.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 249.00 ------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . LL/DANA 574.00 Plan Check Fee . .00 Permit Fee 6/26/03 Valuation 137544 Issue Date . . . . Expiration Date . . 12/23/03 Qty Unit Charge Per Extension 460.00 38.00 3.0000 BASE FEE THOU BLDG, VAL 100001-500000 114.00 -------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ______ _ _ - - -- C� ------------- -- BUILDING DEPT REPRESENT TIVE: APPLICANT: vim BUILDING PERMIT " - C y 60F,;OLLEGE STA`1'iUN 1101 TEXAS AVE COLLEGE STATION, TX 77840 a PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00002040 Page 2 Date 6/26/03 Special Notes and Comments PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE Electrical secondary conduit (feed) onto lot is in the left back corner. (see site plan) CS electrical division request that the meter be located on the shortest distance possible to the conduit. ----------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTAL 350.00 BUILDING DEPT REPRESENTATIVE: APPLICANT:iL�/e�� 7 W BUILDING PERMIT CITY OF COLLEGE STATION ` t 1101 TEXAS AVE - — — - - COLLEGE STATION,- TX 77840^ - PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------- --------------------------------- Page 3 Application Number . . . . . 03-00002040 Date 62 / / 03 -------- --------------------------------------------------------------- Other Fees . . . . . . . . . WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged_ Paid Credited --- Due ----------------- Permit Fee Total ---------- ---------- 574.00 574.00 .00 .00 Plan Check Total `_,.00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1324.00 1324.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: ��UAn L - - - APPLICATION -FOR-BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX7840 (979) 764-3570 (979) 766.�4'-3496 FAX E Fa 2T use oMy — - DATE: ��T�D� APPLICATION # TEMP POLE # WWW.CI.COLLEGE-STATION.TX.US y a ADDRESS/LOCATION: Z0,'20 Z pd' LOT BLOCK ( SUBDIVISION BUSINESS/OWNER NAME: -f I .— or CONTRACTOR/HOMEOWNER: CONTRACTOR ADDRESS: ELECTRICIAN: &t g e L ce-ye-!L �x HVAC: =SSA Iyp 0 VA-Ti v6►' S 2✓tGEs PHONE: PHONE: 7• 6Z66 r 77g.¢ j PLUMBER: r//L(PLE "S P1_&AjRw(; GOOD CENTS (Residential only): /(/ A 1) CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION `t. MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Rep) REMODEL/RENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE: 61A)6 L t< FA M li, y R-P,S/ pj,,��G j= HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPR. VALUATION: $ % 375.4 1 TOTAL AREA: Z883 (Cost of Labor and Materials) CfPUBLIC SEWER SEPTIC/TREATMENT SYSTEM © SEWER TAP: SIZE /WATER TAP: -3�1„ SIZE OTHER TAP: 7rTEMP POLE SIZE GARAGE TYPE: SINGLE AI ACHED N NUMBER OF BEDROOMS NUMBER OF BATHROOMS INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE � TRIPLE DETACHED F__1 CARPORT HEATED AREA: 08 SIGNATURE OF AP PLICANT: � ��,� / Official Use Only t�l Ej or NO Plans Examiner Zoning Official t t Energy Code Compliance khfbrmation t % Glazing of exterior walls Insulation R value of exterio fvalls Insulation R value of ceiling 1 (flat areas) Insulation R value of; oiling 2 (vaulted areas/no attic) Glazing SHGC a Glazing U-Factor ` R value of ductwork`�' A/C SEER rating 2 r] UUI141ONO 11LO &U L7 1(].] 7i8 VDU LUUt NW—UlL• W113111GGtlilt) L11L 1tvlulltl� inirui vvr vvv mod. to. P.44 tjby —" ILars f r-- I ,A.x SCOW 1 ` _ 20' 1 I 1 a-o' I Zot ac� Subdir�vn 1 .w - [nt s Lot 4 114 GS 1 1 n t, Ptk.,ena t t 3 ' Fmposed I I 7.5' , :9 Residlence 7.5' l 1 f �5' P.U.E. R=62a ooL =75 IS' Rawnslone Loop w, craw. w 24, fivmwnont s 461. 4354 Rg iss ACCIME"BHOMEE.RI, .9,1W • sai& ?63- Caller sSb7,f w, %s .rrlszf 69.y -?,ue REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: C:\Program Files\Check\REScheck\2082RL.rck, „y r TITLE: 2082 RAVENSTONE LOOP CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family J DATE: 06/23/03 DATE OF PLANS: JUNE 17, 2003 PROJECT INFORMATION: ` SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 661 t Your Home UA = 572 13.5% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.38 t. Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. , Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 i Bldg. faces 180 deg. from North; Comp. anent.: Front Projection factor: 0.19 Window 5: Metal Frame:Double Pane with Low-E SHGC: 0.40 "4 Bldg. faces 180 deg. from North; Comp. orient.: Front Projection factor: 0.85 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 y Bldg. faces 180 deg. from Norih; Comp. orient.: Left Side Projection factor: 0.27 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E _ 20P Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 2084 30.0 0.0 73 418 15.0 0.0 26 32 0.600 19 16 0.600 10 38 0.400 15 453 15.0 0.0 33 28 0.600 17 418 15.0 0.0 72 22 0.600 43 _ SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.23 Window 6: Metal Frame:Double Pane with Low-E 48 0.600 29 r SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 1.15 Door 2: Glass 18 0.580 10 SHGC: 0.78 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.81 J Wall 4: Wood Frame, 16" o.c. 453 15.0 0.0 32 Window 4: Metal Frame:Double Pane with Low-E 36 0.600 22 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Slab-On-Grade:Unheated 212 0.0 221 Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 10 SEER 1 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lb (formerly MECchec/ and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer �%�- 1— * Date 2 %O J �