Loading...
HomeMy WebLinkAboutRMDL2003-02002 1211 KING ARTHUR CIR BUILDING PERMITPREPARED 9/16/03, 7:01:48 INSPECTION TICKET PAGE 8 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/16/03 ------------------------------------------------------------------------------------------------- ADDRESS . : 1211 KING ARTHUR CIR SUBDIV: CAMELOT #1 TENANT, NBR: PATIO COVER REPAIR CONTRACTOR LONE STAR BUILDERS PHONE (979) 690-6377 OWNER BROOKS, ROBERT D & KATHLEEN P PHONE PARCEL 175000-0102-0050 APPL NUMBER: 03-00002002 RESIDENTIAL, REMODEL & RENOVATION ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B115 01 8/13/03 CH BLDG, FRAMING TIME: 17:00 8/13/03 AP 08/13/2003 09:46 AM KELMENDORF 01 9/16/03 I BLDG, FINAL TIME: 17:00 6q lie/o3 0 C 09/15/2003 01:55 PM GCARRILLO / I L -------------------------------------- COMMENTS AND NOTES ----------------------- ri 0 f l� r --BUILDING PERMIT ITY OF COLLEGE STATION 110 S AVE 4, 4' 'COLLEG , --TX 7 7 8-, .PHONE: (979)764-3570 FAX: (979)764-3496 ' ----------------------------------------------------------------------------- Application Number . . . . . 03-00002002 Date 6/23/03 Property Address . . . . . . 1211 KING ARTHUR CIR Property ID . . . . . . . . . 175000-0102-0050 R # • • • • . . . . . . . R20762 Tenant nbr, name . . . . . . PATIO COVER REPAIR Application description . . . RESIDENTIAL, REMODEL & RENOVATION Subdivision Name . . . . . . CAMELOT #1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . UNKNOWN Application valuation . . . . 5000 Owner Contractor ------------------------ ------------------------ BROOKS, ROBERT D & KATHLEEN P LONE STAR BUILDERS 1211 KING ARTHUR CIR 6020 STRAUB ROAD COLLEGE STATION TX 778404827 COLLEGE STATION TX 77845 (979) 690-6377 -------------------------- Structure Information ------------------------- Construction Type . . . . . **NEEDS TO BE ENTERED** Occupancy Type . . . . . . **NEEDS TO BE ENTERED** Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA 1.00 INTERIOR WALL TYPE NA NUMBER OF BATHROOMS .00 NUMBER OF BEDROOMS .00 SEWER TYPE PUBLIC SERIAL ZONES 199.00 ----------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SAS Permit Fee . . . . 35.00 Plan Check Fee .00 Issue Date . . . . 6/23/03 Valuation . . . . 5000 Expiration Date . . 12/20/03 Qty Unit Charge Per Extension BASE FEE 15.00 4.00 5.0000 THOU BLDG, VAL 1001-50000 20.00 ---------------------------------------------------------------------------- Special Notes and Comments POST PERMIT CARD ON JOB SITE Fee summary Charged Paid Credited ------------------------------ Due ----------------- Permit Fee Total ---------- 35.00 35.00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total 35.00 35.00 .00 .00 r BUILDING DE APPLICANT: -BUILDING PERMIT gITY OF COLLEGE STATION 1101 TEXAS AVE a COLLEGE -tfW 'ION, TX 778, PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00002002 ------------------- BUILDING DE APPLICANT: Page 2 Date 6/23/03 Far Ofte Ux 0* E3APPa_iCATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE ' COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US ' ADDRESS/LOCATION: 12` �-� �.->��� , ,� �" [C LOT BLOCK SUBDIVISION Ca "&�o SEC/PH BUSINESS/OWNER NAME: Ir, m�I� S PHONE: CONTRACTOR/HOMEOWNER: —giyNc �]�. 5Act . 6-5 PHONE: cL-KtZ CONTRACTOR ADDRESS: ELECTRICIAN: PLUMBER: HVAC: GOOD CENTS (Residential only): + CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans EMODEURENOVATION SWIMMING POOL Req ) DESCRIPTION OF WORK:�c,�r--}— STRUCTURE USE: HOMEOWNER ASSOC IATION/ARCH ITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 51noo . cpn TOTAL AREA: HEATED AREA: s (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: SEWER TAP: INTERIOR WALL TYPE: SIZE ❑ WATER TAP: EXTERIOR WALL TYPE: SIZE ❑ OTHER TAP: FOUNDATION TYPE: SIZE ` ❑ TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE F__] DOUBLE F—] TRIPLE F ATTACHED F] DETACHED CARPORT a SIGNATURE OF APPLICANT: -1-22 Official Use Only Comments: YES or NO Plans Examiner Zoning Official Energy .Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) 1 Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating s � c 'b. BASE LINE IS NU I L11 W I i ry •/ 6. RESTRICTIONS IN 290/522 & 785/137, IRF \ 7. BLS SET IN 289/553 & 290/522. tt ' \ 8. EASEMENTS PER PLAT. J PLAIN FLOOD l� O 9. LOCATI❑N OF 100 YR FLOOD PL ET \,�� OBTAINED GRAF9ICALLY FROM c FEMA'S FIRM MAP # 48041CO144 C. ,�� �� C/TV y \ S 100-YR. FLOOD s c� r� ��k- SCALE ,' PLAIN ��*/ ss SO � ., V - 25 APPROX EDGE OF ` EH L00-YP.. FLOOD L/2' /p f .0 �� PLAIN IRF y°j \i 1`) O Ord. C/TV' CI SZ� j. ��E � �* \% • • ..� �' Spy � V SOP �aG \ CO 9'c X\ iC' Pal. =]/2• �O'QJ j �\i LEGEND yQ` j \ ,,i ��G� *q �0 •Zo �X' c��y.J IRF O �O IR =IRON ROD S D * O�G,4'? �' + / IP = IRON PIPE O- Qti 1 CM - CONCRETE MARKER 1*• �`�RO �,l s �R�v� `O . / MOC = MARK ON CONCRETE S/F =SET OR FOUND i FP = FENCE POST FC = FENCE CORNER AC S •�� (3 _ ROW = RIGHT OF WAY )) BB• = BACK TO BACK OF CURB BL = BUILDING LINE PUBLIC UTILITY EASMT. EEE = ELECTRICAL EASEMENT L�P\F�"�G� DE = DRAINAGE EASEMENT AE = ACCESS EASEMENT O A PAE = PARKING/ACCESS EASMT. �0 �* �s ` EM = ELECTRIC METER N , OO ET = ELECTRIC TRANSFORMER / 1 1 E/ P/L = ELECTRICAL/POLE/LIGHT MH = MANHOLE WM �4, \�- CO = CLEAN OUT v WM = WATER METER I� / 1/2, 1 W/V = WATER/VALVE IRF ��� 2 SS = SANITARY SEWER , FH = FIRE HYDRANT GM = GAS METER T/B = TELEPHONE PEDESTAL ( O u C/TV CABLE TV \i \`, Lh AC = AIR CONDITIONER OH =OVERHANG ( M > = MEASURED C ( R > = RECORDCD _J This is to certify that on November 20, 1995, a survey was completed on the ground of the property legally described as Lot 5, Block ?r, Camelot Addition Section One, an addition to the City of College Station, Brazos County, Texas, according to the plat recorded in Volume 289, Page 553, Deed Records, Brazos County, Texas, and that this plat Is true with that survey. This also certifies that, to the best of my knowledge based on the Information currently avallable to me, there are no building structures, building structures intrusions or protrusions, apparent conflicts or visible evidence of easements other than what is shown hereon. Furthermore, as evidenced -in -FENWs- R R"ap-# 48044COI 44 C for Brazos County, Texas, dated July 2, 1992, part of this property appears to Ile within an identified 100-year flood plain-: CHRISTIAN A. GAUNDO, P.E. # 53425, R.P.LS. # 4473 November 21, 1995 Lone StagAuilders and Air C._nditioning P. O. Box 9724, College Station, Tx. 77842 (979) 694-7922 / (979) 695-1928 fax Email: osandman@msn.com PROPOSAL #: 03-05061 DATE OF PROPOSAL: 05/13/03 4ri PROPOSAL SUBMITTED TO: WORK TO BE PERFORMED AT: Bob and Kathleen Brooks 1211 King Arthur Circle 1211 King Arthur Circle College Station, Tx. College Station, Tx. 77840 (979) 693-0614 / email: brooks@tamu.edu WE HEREBY PROPOSE TO FURNISH THE MATERIALS AND PERFORM THE LABOR NECESSARY FOR THE COMPLETION OF: Scope of work includes using owner's supplied materials and some additional materials. Temporary bracing of original roof to support new roof extension: install 12' 2x6 purling over -north hall wall;•install-10' 2x6 purling over kitchen wall; install 20' 2x6 "A" frame stiffener over living area from hallway,wall to-kitchen/living area wall; install 24 collar ties. Rebuild porch beam: install 3 posts in anchored bases; remove existing porch soffit; install, tern porari braci6g,to, support roof allowing removal and replacement of north side porch beam using double 2x12 and 3/16" x 10" steel header plate. Joist out back porch and stiff back: install 32 joists; install dead wood; install stiff back; frame access door: '1 Permanent roof brace off: Build purlings over porch every 10'; install king post under,ridge; stud -gable wall and install( stiffener; install roof braces over original roof; sister all rafter scabs on, beam. Wall: Gear back wall of house and install %' foam insulate board; fur out back wall of fl6use for-T411 install brick frieze. Cornice: install soffit in porch area; install T-111 brick frieze on. back walls fur header plate for finish wrap; install T-111 siding on north wall of porch and on north side of dining area; dress out beam; trim out inside of porch area;,replace 110' fascia and shingle mold with 1x6 and 1x2 fingerjoint redwood $-5893.43--o. Install sub -panel next to exterior main; dig trench from main to right rear corner of green house; install conduit and 12 gauge 3-wire line from greenhouse to sub -panel; install 15 amp g.f.c.i. breaker in sub -panel; fill in trench; connect to existing electrical wiring in greenhouse at junction box 611.33 Install switch in greenhouse; dig trench 24' to proposed pond location; run 12 gauge wire and conduit from switch to pond location; install g.f.c.i. outlet in weatherproof case; fill trench 333.14 Install "T" at back porch hose bib; run surface mount pvc; %" pipe along house; dig trench from rear right corner of house to greenhouse; install pipe in trench and stub -up at greenhouse wall; install hose bib; fill trench 208.96 Rewire back porch area and mount four owner supplied fans on back porch 250.00 Patch sheetrock at breaker panel in garage 75.00 Extend heater flue through roof, install cap, jack and storm collar 154.95 Extend auxiliary a/c condensate drain pan pipe to exterior of new porch 62.98 Remove window on back porch; cut out brick; install lentel and french door; build wood return to cover where brick is cut out (does not include painting) 1275.80 Blow 4" cellulose insulation over heated attic space 1020.00 Re -weave in two valleys on roof where improperly installed (price includes materials and labor) 650.00 Remove third switch from left side of patio door; re -wire to adjacent 2 switch box; install double switch to replace one of the single switches; install blank cover plate over 3 switch box; install matching cover plate on 3 switch box 50.53 ALL MATERIALS ARE GUARANTEED TO BE AS SPECIFIED AND THE ABOVE WORK TO BE PERFORMED IN ACCORDANCE WITH THE DRAWINGS AND SPECIFICATIONS SUBMITTED FOR ABOVE WORK AND COMPLETED FOR THE SUM OF: Ten thousand five hundred eighty-six dollars and 12/100 WITH PAYMENTS TO BE MADE AS FOLLOWS: 25% due upon acceptance of proposal - $2,646.53 25% due upon completion of rebracing - $2,646.53 25% due upon completion of electrical - $2,646.53 25% due upon completion of job - $2,646.53 10, 586.12) ANY ALTERATIONS OR DEVIATIONS FROM ABOVE SPECIFICATIONS INVOLVING EXTRA COSTS WILL BE EXECUTED ONLY UPON WRITTEN ORDERS AND WILL BECOME AN EXTRA CHARGE OVER AND ABOVE THE ESTIMATE. ALL AGREEMENTS CONTINGENT UPON STRIKES, ACCIDENTS OR DELAYS BEYOND OUR CONTROL. OWNER TO CARRY FIRE, TORNADO OR OTHER NECESSARY IINSURANCE UPON ABOVE WORK RESPECTFULLY SUBMITTED: PER MANAGER, LONE STAR BUILDERS AND AIR CONDITIONING