HomeMy WebLinkAboutRES2003-01985PREPARED 2/09/04, 7:38:57 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/09/04 ------ ---------------------------------------------------------------------------------------- ADDRE2076 RAVENSTONE LOOP SUBDIV- CASTLEGATE SEC 1 PH 1 CONTFPCTOR ED FROEHLING BUILDERS PHONE (979) 776-8266 OWNER . . GREENS PRAIRIE INVESTORS LTD PHONE PARCEL'. . 184200-I101-0080 APPL NUMBER: 03-00001985 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT • REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS .,.:--------------------------------------------------------------------------------------------- 1700 01 7/25/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 _ 7/25/03 AP 07/24/2003 01:26 PM SSTANLEY STRINGS ON SETBACKS OK. SLAB GROUND BACK LEFT SIDE. 'B115 01 9/10/03 TB BLDG, FRAMING TIME: 17:00 9/10/03 AP 09/09/2003 12:45 PM SSTANLEY Add joist hangers Q attic access. B130 01 9/16/03 TB BLDG, INSULATION TIME: 17:00 9/16/03 AP 09/15/2003 02:19 PM SSTANLEY B125 01 2/09/04 B BLDG, FINAL TIME: 17:00 02/06/2004 02:02 PM SSTANLEY ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- LAw#j i � ywfi �w r CITY OF COLLEGE STATION WORK 'BEQUEST PAGE 1 REQ/JOB: WF0420839 , 11 PROJECT: REQUEST DATE: 6/24/03 'PRINT DATE: 6/24/03 CREW: PRINT TIME: 15:46:17 SCHSTAARRT.DATES LOCATION: 2076 RAVENSTONE LOOP 6/24/03 77845 COMPLETION: 6724703 GEN. LOC: COLLEGE STATION LOC ID: 191036 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: ED FROEHLING BLDRS (776-8266) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: . SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- OT-CUSTOMER SERVICE T BUILDING PERMIT, CITY OF COLLEGE STATIO' 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 --=------------------------------------------------------------------------- Application Number . . . . . 03-00001985 Date 6/24/03 Property Address . . . . . . 2076 RAVENSTONE LOOP Property ID . . 184200-0101-0080 R # • • . . . . . . . R109177 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . CASTLEGATE SEC 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . PLANNED DEVL HOUSING Application valuation . . . . 138666 Owner Contractor - ------------------------ ----------------------- GREENS PRAIRIE INVESTORS LTD ED FROEHLING BUILDERS 4490 CASTLEGATE DR ED FROEHLING COLLEGE STATION TX 778453388 3887 HIGH LONESOME RD COLLEGE STATION TX 77845 (979) 776-8266 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 2101.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLI SERIAL ZONES 249.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc LL Permit Fee 577.00 Plan Check Fee .00 Issue Date . . . . 6/24/03 Valuation . . . . 138666 Expiration Date . . 12/21/03 Qty Unit Charge Per Extension BASE FEE 460.00 39.00 3.0000 THOU BLDG, VAL 100001-500000 117.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) BUILDING DEPT REPRESENTATIVEAPPLICANT: M6i) BUILDING PERMIT CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001985 Page 2 Date 6/24/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid ---------- Credited -------------------- Due ----------------- Permit Fee Total ---------- 577.00 577.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1327.00 1327.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT a CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001985 BUILDING DEPT REPRESENTATIVE: h..(1T -, _ . APPLICANT: Page 3 Date 6/24/03 For office Use day ...,.} 4v + t APrLICATION,, FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG E-STATION.TX.US DATE: V LJIV = f O APPLICATION # 03 l 019 TEMP POLE # ADDRESS/LOCATION: ZO 76 Aj/6,&4g?o ,C 1g00 LOT BLOCK I SUBDIVISION 6,A571L-F Te BUSINESS/OWNER NAME: PHONE: CONTRACTOR/HOMEOWNER: J�j> tCn of az-wG, gy m raa PHONE: 77.1 • SZ96 CONTRACTOR ADDRESS: 5861 R-149 L.oA/ti sAME AD 40u_e4E S7A4ny,! 7"X 7784j .01 ELECTRICIAN: St g p_-LEGT/�!� PLUMBER: -rAIPLS "S PLyn r' w4 HVAC: ,'SCa Iym o VA-7ryE S952Vi4E5 GOOD CENTS (Residential only): /i/A CLASS OF WORK ACCESSORY/STOkAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: STRUCTURE USE:' S1,U6 L. j!5 F.A. M IL, y __ _ ��/ fyw HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 138666 TOTAL AREA: 2-939 HEATED AREA: ZI 0 I (Cost of Labor and Materials) ePUBLIC SEWER NUMBER OF BEDROOMS: _ F] SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: LJ SEWER TAP: 14 of INTERIOR WALL TYPE: 3A 1466 % rQ c- /�- SVE %WATER TAP: 3�_' It EXTERIOR WALL TYPE: 13j&[LJ< SME OTHER TAP: TEMP POLE GARAGE TYPE: SIZE SINGLE El ATTACHED SIGNATURE OF APPLICANT: FOUNDATION TYPE: 6414. M D,tJ 40A ROOF TYPE: DOUBLE Eff DETACHED a LQAPDSI?/yA% 5fi A)Q-E TRIPLE a CARPORT Ofcial Use Only - ents: YE or NO Plans Examiner Zoning Official I t n � \ s Energy Code Compliance Information %r G1Azing of exterior' walls Insulation R value of exterior walls( • Insulation R value of ceiling 1 (flat areas) f--3o Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC n Glazing U-Factor R value of ductwork A/C SEER rating JR 'sp. 0 TL a P. • e REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lb Data filename: Untitled.rck TITLE: 2076 RAVENSTONE LOOP CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 06/18/03 DATE OF PLANS: JUNE 17, 2003 PROJECT INFORMATION: SPEC HOME COMPANY INFORMATION: ED FROEHLING BUILDER, INC COMPLIANCE: Passes Maximum UA = 627 Your Home UA = 544 13.2% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.39 Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Front Projection factor: 0.18 Door 1: Solid Wall 2: Wood Frame, 16" o.c. Window 2: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Left Side Projection factor: 0.18 Wall 3: Wood Frame, 16" o.c. Window 3: Metal Frame:Double Pane with Low-E SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.27 Door 2: Glass i G Permit Number' Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R Value U-Factor UA 2101 30.0 0.0 74 423 15.0 0.0 26 50 0.600 30 38 490 15.0 0.0 38 0.400 15 35 0.600 23 376 15.0 0.0 21 84 0.600 50 18 0.580 10 SHGC: 0.78 Bldg. faces 180 deg. from North; Comp. orient.: Back Projection factor: 0.81 Wall 4: Wood Frame,16" o.c. 392 15.0 0.0 26 Window 4: Metal Frame with Thermal Break:Double Pane with Low-E 56 0.600 34 SHGC: 0.40 Bldg. faces 180 deg. from North; Comp. orient.: Right Side Projection factor: 0.27 Floor 1: Slab-On-Grade:Unheated 192 0.0 200 Insulation depth: 0.0' COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lb (formerly MECchec4 and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer 1�' Date R O 06/18/2003 WED 23:30 WX 979 693 2554 McClure Engineering Inc. 443 Froehling, Edw+ar 005/006 • SAM 1• �pi iL� ---- - AI 7'f?' E -r 81.4r _ .s- top P.U. r by U26 PC" 1 i 47.V t j Lot } ■ �.1 1,1 1 a 2Cr A . � I Lot 7 i � f � Pita mcf �1 R.s 12li 4 Q' � i� � 5 p.U.E. d-71J'2a" ~20t00' 1-7& � Ra►vrznstom Loop W 4M4 PA 164 �-aebo� air By&viva Aw, fawjvawbvk*Aft .s&.* tar• t ea�if� v Amr rii, raw;7w- f.,Povj AqmAw