HomeMy WebLinkAboutRES2003-01966PREPARED 10/27/03, 12:12:00
INSPECTION TICKET PAGE 8
City of
College Station
INSPECTOR: BUILDING INSPECTOR DATE 10/27/03
------------------------------------------------------------------------------------------------
ADDRESS
. : 3709 SPRINGFIELD DR SUBDIV: WESTFIELD ADDITION PH 2A
CONTRACTOR MAIN STREET HOMES
PHONE (512) 690-9964
OWNER
•: MAIN STREET HOMES
CS LTD PHONE
PARCEL
650700-1201-0050
APPL NUMBER: 03-00001966 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
8/06/03 DS
BLDG, FOUNDATION -SLAB TIME: 17:00
8/06/03 DP
08/05/2003 04:19 PM KELMENDORF
NO SLAB GROUND. NO SLAB SURVEY
B: 02
8/07/03 DS
BLDG, FOUNDATION -SLAB TIME: 17:00
8/07/03 AP
08/07/2003 01:12 PM SSTANLEY
slab ground front left side
B115 01
9/05/03 DS
BLDG, FRAMING TIME: 17:00
9/08/03 DP
09/04/2003 02:22 PM SSTANLEY
Need to wrap OSB. Need to fix fire blocking knocked out.
Need to use sheetrock to fix stop around fireplace. Anchor
nuts loose.
B115 02
9/15/03 DS
BLDG, FRAMING TIME: 17:00
9/15/03 DP
09/12/2003 02:09 PM MALFORD
Afternoon Please on 9/15/03
09/15/2003 03:09 PM MALFORD
anchor nuts still loose , OSB not felted
B115 04
9/16/03 BI
BLDG, FRAMING TIME: 17:00
10/20/03 CA
09/16/2003 11:28 AM SSTANLEY
REINSPECT
B 03
9/16/03 OC
BLDG, FRAMING TIME: 17:00
9/16/03 AP
09/16/2003 08:22 AM MALFORD
B125 01
10/27 03 BI
BLDG, FINAL TIME: 17:00
[01?1 03 Af 0C-
10/27/2003 08:58 AM SSTANLEY
-------------------------------------- COMMENTS AND NOTES--------------------------------------
4rNo Stt,"4;on,
Mandi Alford- Insulation request insper result, 3709 Springfield, #0396 -16 Page 1
From: Brian Henry
To: Elmendorf, Katy
Date: 9/19/2003 11:07:47 AM
Subject: Insulation request inspection result, 3709 Springfield, #03-1966
Print for File
Inspected insulation, 3709 Springfield, #03-1966, Mainstreet, Homes, 9-19-03
Inspection result: Inspected OK for Code Only
CC: Alford, Mandi
CITY OF COLLEGE STATION
WORF 3QUEST
PAGE
1
REQ/JOB:
WF0421985 / 001 PROJECT:
REQUEST DATE:
6/26/03
PRINT DATE:
6/26/03
CREW:
PRINT TIME:
16:19:40
SCHSTAARRT.DATES
LOCATION:
3709 SPRINGFIELD DR
6/26/03
77845
COMPLETION:
6/26703
GEN. LOC:
COLLEGE STATION LOC ID: 196356
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
MAIN STREET HOMES ORIGIN:
CUSTOMER -WALK
IN
USER D:
LLONG AUTH: LLONG WORK TYPE:
ROUTINE
3I%4"WTR,4"SWR
3/4"WTR,4"SWR
Category
code CS -CUSTOMER SERVICES CSCS
Task code:
. SET UP NEW UTILITY ACCT SET
Facility
ID
Assigned Department: OT-CUSTOMER SERVICE
�, BU LDING PERMIT
GE . STAM
i 1 rO'l TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
• Application Number . . . . . 03-00001966 Date 6/26/03
r Property Address . . . . . . 3709 SPRINGFIELD DR
Property ID . . 650700-0201-0050
R # . . . . . . . . . . . . . R114101
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . . . . . WESTFIELD ADDITION PH 2
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 81840
Owner Contractor
------------------------ ------------------------
MAIN STREET HOMES CS LTD MAIN STREET HOMES
% MSH-CS INC RICK JENKINS PETER L DAVIS
7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150
AUSTIN TX 787464130 AUSTIN TX 78746
(512) 690-9964
------ Structure Information SINGLE FAMILY -----
Construction Type . . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info . . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1240.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.00
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 248.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING PERMIT
Additional desc . . MR
Permit Fee . . . . 388.00 Plan Check Fee .00
Issue Date . . . . 6/26/03 Valuation . . . . 81840
Expiration Date . . 12/23/03
Qty Unit Charge Per Extension
BASE FEE 260.00
32.00 4.0000 THOU BLDG, VAL 50001-100000 128.00
----------------------------------------------------------------------------
Special Notes and Comments
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR (S)
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
BUILDING DEPT REPRESENTATIVE:
A
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIC
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
2
Application Number . . . . . 03-00001966 Date
6/26/03
----------------------------------------------------------------------------
Special Notes and Comments
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 388.00 388.00 .00
.00
Plan Check Total .00 .00 .00
.00
Other Fee Total 750.00 750.00 .00
.00
Grand Total 1138.00 1138.00 .00
.00
----------------------------------------------------- ----- --------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
_, e
APr-LICATION FOR BUILDING PERM,
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
WW W.CI.COLLEGESTATION.TX.US
ADDRESS/LOCATION:
WJW!M
LOT !j BLOCK ' SUBDIVISION Westfield
BUSINESS/OWNER NAME:
CONTRACTOR/HOMEOWNER: Main Street Homes
/FarO toeruse Or*
DATE:
APPLICATION
TEMP PO E #
PHONE:
PHONE: (512) 327-8620
CONTRACTOR ADDRESS: 744g7 a66 6WE 2P ''1Z; 6571k,� . TX 7dr7s(6
ELECTRICIAN: Hillco Electric
HVAC: Barkers HVAC
PLUMBER: CP Plumbing
GOOD CENTS (Residential only): 96
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Construct Single Family Residence
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS))� PROJECT REGISTRATION# EABPRJ
VALUATION: $ Oj2a � R I S 11I1 OO TOTAL AREA: /(o O HEATED AREA: 1-?qO
(cost of Labor and Materials) 2
PUBLIC SEWER NUMBER OF BEDROOMS: 3
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: a
a SEWER TAP: Ott INTERIOR WALL TYPE: Wood / Sheetrock
SIZE
WATER TAP: 3 / 4" EXTERIOR WALL TYPE: —Wood/ Masonry
SIZE
❑ OTHER TAP:
FOUNDATION TYPE:
Post Tension on Grade
SIZE
❑ TEMP POLE
ROOF TYPE:
Asphalt
Shingles
GARAGE TYPE: SINGLE a
DOUBLE ® TRIPLE
a
ATTACHED ®
CARPORT
DETACH-E"D�
a
SIGNATURE OF APPLICANT:
_j
�C
Official Use Only
ants:
YE or NO
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
,76
ZZ
ITL
�.A",
REScheck Compliance Certificate
2000 IECC
REScheckSoflware Version 3.5 Release la
Data filename: F:\Root\Mainstreet\Share\Construction\MECcheck\1251-CS.cck
TITLE: 1251
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 06/17/03
COMPANY INFORMATION:
Main Street Homes, Ltd.
COMPLIANCE: Passes
Maximum UA = 327
Your Home UA = 253
22.6% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Ceiling 1: Cathedral Ceiling (no attic)
Ceiling 2: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane
SHGC: 0.36
Door 1: Solid
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 4: Electric Central Air, 12 SEER
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
169
22.0 0.0 8
1082
0.0 30.0 34
1232
15.0 0.0 77
168
0.640 108
58
0.450 26
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release la (formerly MECchec)� and to comply with the mandatory requirements listed in
the REScheckInspection Checklist.
Builder/Designer Date
-9
REScheck Inspection Checklist
2000 IECC
REScheckSoflware Version 3.5 Release la
DATE: 06/17/03
TITLE: 1251
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Cathedral Ceiling (no attic), R-22.0 cavity insulation
Comments:
[ ] 2. Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-15.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame, Double Pane, U-factor: 0.640
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Solid, U-factor: 0.450
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
[ ] 2. Air Conditioner 4: Electric Central Air, 12 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
1 3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided
[ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
i 4
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R 8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] ( Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
A 0 . c
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipet
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range F
2" Runouts
1" and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)