Loading...
HomeMy WebLinkAboutRES2003-01966PREPARED 10/27/03, 12:12:00 INSPECTION TICKET PAGE 8 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/27/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 3709 SPRINGFIELD DR SUBDIV: WESTFIELD ADDITION PH 2A CONTRACTOR MAIN STREET HOMES PHONE (512) 690-9964 OWNER •: MAIN STREET HOMES CS LTD PHONE PARCEL 650700-1201-0050 APPL NUMBER: 03-00001966 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/06/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 8/06/03 DP 08/05/2003 04:19 PM KELMENDORF NO SLAB GROUND. NO SLAB SURVEY B: 02 8/07/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 8/07/03 AP 08/07/2003 01:12 PM SSTANLEY slab ground front left side B115 01 9/05/03 DS BLDG, FRAMING TIME: 17:00 9/08/03 DP 09/04/2003 02:22 PM SSTANLEY Need to wrap OSB. Need to fix fire blocking knocked out. Need to use sheetrock to fix stop around fireplace. Anchor nuts loose. B115 02 9/15/03 DS BLDG, FRAMING TIME: 17:00 9/15/03 DP 09/12/2003 02:09 PM MALFORD Afternoon Please on 9/15/03 09/15/2003 03:09 PM MALFORD anchor nuts still loose , OSB not felted B115 04 9/16/03 BI BLDG, FRAMING TIME: 17:00 10/20/03 CA 09/16/2003 11:28 AM SSTANLEY REINSPECT B 03 9/16/03 OC BLDG, FRAMING TIME: 17:00 9/16/03 AP 09/16/2003 08:22 AM MALFORD B125 01 10/27 03 BI BLDG, FINAL TIME: 17:00 [01?1 03 Af 0C- 10/27/2003 08:58 AM SSTANLEY -------------------------------------- COMMENTS AND NOTES-------------------------------------- 4rNo Stt,"4;on, Mandi Alford- Insulation request insper result, 3709 Springfield, #0396 -16 Page 1 From: Brian Henry To: Elmendorf, Katy Date: 9/19/2003 11:07:47 AM Subject: Insulation request inspection result, 3709 Springfield, #03-1966 Print for File Inspected insulation, 3709 Springfield, #03-1966, Mainstreet, Homes, 9-19-03 Inspection result: Inspected OK for Code Only CC: Alford, Mandi CITY OF COLLEGE STATION WORF 3QUEST PAGE 1 REQ/JOB: WF0421985 / 001 PROJECT: REQUEST DATE: 6/26/03 PRINT DATE: 6/26/03 CREW: PRINT TIME: 16:19:40 SCHSTAARRT.DATES LOCATION: 3709 SPRINGFIELD DR 6/26/03 77845 COMPLETION: 6/26703 GEN. LOC: COLLEGE STATION LOC ID: 196356 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN USER D: LLONG AUTH: LLONG WORK TYPE: ROUTINE 3I%4"WTR,4"SWR 3/4"WTR,4"SWR Category code CS -CUSTOMER SERVICES CSCS Task code: . SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE �, BU LDING PERMIT GE . STAM i 1 rO'l TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- • Application Number . . . . . 03-00001966 Date 6/26/03 r Property Address . . . . . . 3709 SPRINGFIELD DR Property ID . . 650700-0201-0050 R # . . . . . . . . . . . . . R114101 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD ADDITION PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 81840 Owner Contractor ------------------------ ------------------------ MAIN STREET HOMES CS LTD MAIN STREET HOMES % MSH-CS INC RICK JENKINS PETER L DAVIS 7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150 AUSTIN TX 787464130 AUSTIN TX 78746 (512) 690-9964 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1240.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MR Permit Fee . . . . 388.00 Plan Check Fee .00 Issue Date . . . . 6/26/03 Valuation . . . . 81840 Expiration Date . . 12/23/03 Qty Unit Charge Per Extension BASE FEE 260.00 32.00 4.0000 THOU BLDG, VAL 50001-100000 128.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S) IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR BUILDING DEPT REPRESENTATIVE: A APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIC 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00001966 Date 6/26/03 ---------------------------------------------------------------------------- Special Notes and Comments TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 388.00 388.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1138.00 1138.00 .00 .00 ----------------------------------------------------- ----- -------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: _, e APr-LICATION FOR BUILDING PERM, CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WW W.CI.COLLEGESTATION.TX.US ADDRESS/LOCATION: WJW!M LOT !j BLOCK ' SUBDIVISION Westfield BUSINESS/OWNER NAME: CONTRACTOR/HOMEOWNER: Main Street Homes /FarO toeruse Or* DATE: APPLICATION TEMP PO E # PHONE: PHONE: (512) 327-8620 CONTRACTOR ADDRESS: 744g7 a66 6WE 2P ''1Z; 6571k,� . TX 7dr7s(6 ELECTRICIAN: Hillco Electric HVAC: Barkers HVAC PLUMBER: CP Plumbing GOOD CENTS (Residential only): 96 CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Construct Single Family Residence STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS))� PROJECT REGISTRATION# EABPRJ VALUATION: $ Oj2a � R I S 11I1 OO TOTAL AREA: /(o O HEATED AREA: 1-?qO (cost of Labor and Materials) 2 PUBLIC SEWER NUMBER OF BEDROOMS: 3 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: a a SEWER TAP: Ott INTERIOR WALL TYPE: Wood / Sheetrock SIZE WATER TAP: 3 / 4" EXTERIOR WALL TYPE: —Wood/ Masonry SIZE ❑ OTHER TAP: FOUNDATION TYPE: Post Tension on Grade SIZE ❑ TEMP POLE ROOF TYPE: Asphalt Shingles GARAGE TYPE: SINGLE a DOUBLE ® TRIPLE a ATTACHED ® CARPORT DETACH-E"D� a SIGNATURE OF APPLICANT: _j �C Official Use Only ants: YE or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating ,76 ZZ ITL �.A", REScheck Compliance Certificate 2000 IECC REScheckSoflware Version 3.5 Release la Data filename: F:\Root\Mainstreet\Share\Construction\MECcheck\1251-CS.cck TITLE: 1251 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 06/17/03 COMPANY INFORMATION: Main Street Homes, Ltd. COMPLIANCE: Passes Maximum UA = 327 Your Home UA = 253 22.6% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Ceiling 1: Cathedral Ceiling (no attic) Ceiling 2: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane SHGC: 0.36 Door 1: Solid Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 4: Electric Central Air, 12 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 169 22.0 0.0 8 1082 0.0 30.0 34 1232 15.0 0.0 77 168 0.640 108 58 0.450 26 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheckVersion 3.5 Release la (formerly MECchec)� and to comply with the mandatory requirements listed in the REScheckInspection Checklist. Builder/Designer Date -9 REScheck Inspection Checklist 2000 IECC REScheckSoflware Version 3.5 Release la DATE: 06/17/03 TITLE: 1251 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Cathedral Ceiling (no attic), R-22.0 cavity insulation Comments: [ ] 2. Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation Comments: Above -Grade Walls: [ ] 1. Wall 1: Wood Frame, 16" o.c., R-15.0 cavity insulation Comments: Windows: [ ] 1. Window 1: Metal Frame, Double Pane, U-factor: 0.640 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor: 0.450 Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number [ ] 2. Air Conditioner 4: Electric Central Air, 12 SEER or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 1 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: i 4 [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R 8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] ( Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. A 0 . c Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipet Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)