HomeMy WebLinkAboutRES2003-0196503--Iq(0.5 I
r
PREPARED 12/18/03, 12:09:20 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 12/18/03
------------------------------------------------------------------------------------------------
ADDRESS . : 3716 SPRINGFIELD DR SUBDIV: WESTFIELD ADDITION PH 2
CONTRACTOR MAIN STREET HOMES PHONE (512) 690-9964
OWNER MAIN STREET HOMES CS LTD PHONE
PARCEL 650700-0204-0090
APPL NUMBER: 03-00001965 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/26/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00
8/28/03 DP 08/26/2003 08:27 AM SSTANLEY
w NO SLAB GROUND. NEED STIRUPS (NOT RODS DRIVEN INTO
GROUND). REMOVE WATER. FIX PLASTIC
B100 02 9/08/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00
9/08/03 DP 09/05/2003 04:00 PM MALFORD
r
None of the things on 1st red tag. Plus beams caved in.
B100'03 9/11/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00
9/11/03 AP 09/10/2003 02:45 PM GCARRILLO
B130 01 9/11/03 BI BLDG, INSULATION TIME: 17:00
9/11/03 CA 09/10/2003 02:45 PM GCARRILLO
B115 01 10/20/03 BI BLDG, FRAMING TIME: 17:00
10/22/03 DP 10/20/2003 10:34 AM GCARRILLO
NEED ELECTRIC PERMIT, MECH ROUGH IN
10/22/2003 06:51 AM MALFORD
needs just hangers on ceiling over stairs (by light box)
needs to sheetrock fireplace between floors
B115.02 10/23/03 TB BLDG, FRAMING TIME: 17:00
10/23/03 AP 10/22/2003 12:43 PM SSTANLEY
B: 011 12/18/03 /CBI BLDG, FINAL TIME: 17:00
1), It(O3 A-'P OC- 12/18/2003 09:36 AM SSTANLEY
V
--------------------------T---------- COMMENTS AND NOTES --------------------------------------
�%� �rr�������
Mandl Alford -Insulation request inspection result, 3716 Springfield, #03-1965
r
From: Brian Henry
To: Carrillo, Gina; Stanley, Susan
Date: 10/29/2003 10:19:24 AM
Subject: Insulation request inspection result, 3716 Springfield, #03-1965
Print for File
Inspected Insulation, 3716 Springfield, #03-1965, Mainstreet Homes, 10-29-03
Inspection result: Inspected for Code Only
CC: Alford, Mandl
CITY OF COLLEGE STATION
WORT i"QUEST
REQ/JOB: WF0421987 / 001 PROJECT:
CREW:
LOCATION: 3716 SPRINGFIELD DR
77845
PAGE 1
PRQINTST DATE: DATTE: 6%26%03
PRINT TIME: 16:20:24
SCHEDULE DATES
START: 6/26/03
COMPLETION: 6726703
GEN. LOC: COLLEGE STATION LOC ID: 196386
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN
USER D: LLONG AUTH: LLONG WORK TYPE: ROUTINE
3/4"WTR,4"SWR
3/4"WTR,4"SWR
Category code .
Task code:
Facility ID
Assigned Department:
CS -CUSTOMER SERVICES
SET UP NEW UTILITY ACCT
OT-CUSTOMER SERVICE
CSCS
SET
f
7
BUILDING PERMIT,
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00001965 Date 6/26/03
Property Address
. . . . . . 3716 SPRINGFIELD DR
Property ID
. . 650700-0204-0090
R # . . . . . . .
. . . . . . R114130
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
. . . . . . WESTFIELD ADDITION PH 2
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 151272
Owner
Contractor
------------------------
MAIN STREET HOMES
------------------------
CS LTD MAIN STREET HOMES
o MSH-CS INC RICK
JENKINS PETER L DAVIS
7447 BEE CAVES RD
STE 150 7447 BEE CAVE ROAD #150
AUSTIN
TX 787464130 AUSTIN TX 78746
(512) 690-9964
------ Structure Information SINGLE FAMILY -----
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 2292.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 5.00
SEWER TYPE PUBLIC
SERIAL ZONES 248.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. MR
Permit Fee . . .
. 616.00 Plan Check Fee .00
Issue Date . . .
. 6/26/03 Valuation . . . . 151272
Expiration Date .
. 12/23/03
Qty Unit Charge Per Extension
BASE FEE 460.00
52.00 3.0000 THOU BLDG, VAL 100001-500000 156.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT C7CUIT
INTERRUPTER (S )
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
r
BUILDING PERMIT
CITY OF COLLEGE STATIC
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00001965
Page 2
Date 6/26/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
EXIT DOOR(S)
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 15% of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) OR SECTION
1003.3.3 (2000 IBC) AS APPROPRIATE
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
----------------------------------------------------------------------------
Other Fees . . .
. . . . . .
SEWER TAP 4"
CITY INSTALL
350.00
WATER TAP 3/4"
CITY INSTL
400.00
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
--------------------
Due
Permit Fee Total
616.00
616.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1366.00
1366.00
.00
.00
---------------------------------------------------- - - -- ----------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
•,!
APrLICATION FOR BUILDING PERMI I
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION:
LOT BLOCK SUBDIVISION
BUSINESS/OWNER NAME:
371
CONTRACTOR/HOMEOWNER: Main Street Homes
Westfield
warm uSO 0*
DATE. (- I 0 -Q
APPucAnoN -3_'��'
TEMP PoL(#
PHONE:
PHONE: (512) 327-8620
CONTRACTOR ADDRESS: 7dy1 G4uc g�.IS�, �c.c$( r� , Jac {'��(o
ELECTRICIAN: Hillco Electric
HVAC: Barkers HVAC
PLUMBER: CP Plumbing
GOOD CENTS (Resideneal only): O
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Construct Single Family Residence
STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT EGISTRATION# EABPRJ
VALUATION: $ 79,,- D--' TOTAL AREA: 7& 9 HEATED AREA:9�
(Ckgfioftabor and teria )
X❑ PUBLIC SEWER
SEPTIC/TREATMENT SYSTEM
a SEWER TAP: 4"
Size
X I WATER TAP: 3 / 4"
SIZE
OTHER TAP:
SIZE
TEMP POLE
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE:
Wood / Sheetrock
Wood/ Masonry
Post Tension on Grade
Asphalt Shingles
GARAGE TYPE: SINGLE F__j DOUBLE ® TRIPLE a
ATTACHED ® DETACHED a CARPORT
SIGNATURE OF APPLICANT:
Official Use Only
ants:
YES r NO
Plans Examiner Zoning Official
Z ��
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
ti . ,'W %1
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release la
Data filename: F:\Root\Mainstreet\Share\Construction\UECcheck\2292-CS.cck
TITLE: 2292
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 06/13/03
COMPANY INFORMATION:
Main Street Homes, Ltd.
COMPLIANCE: Passes
Maximum UA = 634
Your Home UA = 506
20.2% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.36
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1: Cathedral Ceiling (no attic)
272
22.0
0.0
13
Ceiling 2: Flat Ceiling or Scissor Truss
1315
0.0
30.0
41
Wall 1: Wood Frame, 16" o.c.
2400
15.0
0.0
161
Window 1: Metal Frame, Double Pane
255
0.640 163
SHGC: 0.36
Door 1: Solid
58
0.450 26
Floor 1: All -Wood Joist/Truss:Over Unconditioned Space
411
0.0
0.0
102
Furnace 1: Forced Hot Air, 80 AFUE
Air Conditioner 1: Electric Central Air, 12 SEER
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
requirements in REScheckVersion 3.5 Release la (formerly MECchec4 and to comply with the mandatory requirements listed in
the REScheckInspection Checklist.
Builder/Designer Date
i
REScheck Inspection Checklist
2000 IECC
REScheckSoflware Version 3.5 Release la
DATE: 06/13/03
TITLE: 2292
Bldg.
Dept.
Use
Ceilings:
[ ] 1. Ceiling 1: Cathedral Ceiling (no attic), R-22.0 cavity insulation
Comments:
[ ] 2. Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation
Comments:
Above -Grade Walls:
[ ] 1. Wall 1: Wood Frame, 16" o.c., R-15.0 cavity insulation
Comments:
Windows:
[ ] 1. Window 1: Metal Frame, Double Pane, U-factor: 0.640
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
[ ] 1. Door 1: Solid, U-factor: 0.450
Comments:
Floors:
[ ] 1. Floor 1: All -Wood JoistlTruss:Over Unconditioned Space, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
[ ] 1. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
[ ] 2. Air Conditioner 1: Electric Central Air,12 SEER or higher
Make and Model Number
Solar Heat Gain Coefficient:
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing L-xactors, and heating and cooling equipment efficiLency must be clearly
marked on the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
operating at less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
Low Temperature
Steam Condensate (for feed water)
Cooling Systems
Chilled Water, Refrigerant,
and Brine
201-250
1.0
1.5
1.5
2.0
120-200
0.5
1.0
1.0
1.5
Any
1.0
1.0
1.5
2.0
40-55
0.5
0.5
0.75
1.0
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)