Loading...
HomeMy WebLinkAboutRES2003-01964PREPAJZED 11/12/03, 12:01:31 INSPECTION TICKET PAGE 6 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/12/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 3706 SPRINGFIELD DR SUBDIV: WESTFIELD ADDITION PH 2 CONTRACTOR MAIN STREET HOMES PHONE : (512) 690-9964 OWNER MAIN STREET HOMES CS LTD PHONE : PARCEL : 650700-0204-0040 APPL NUMBER: 03-00001964 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIET REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/26/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 8/28/03 AP 08/26/2003 08:26 AM SSTANLEY B bl 10/07/03 DS BLDG, FRAMING TIME: 17:00 10/07/03 AP 10/07/2003 08:06 AM SSTANLEY B125 01 11/12/03 B BLDG, FINAL TIME: 17:00 11/12/2003 08:14 AM MALFORD ------------p 3---------------� -------------------------------------- ------ COMMENTS AND NOTES fya Mandi Alford - Insulation request inspectii ;suit, 3706 Springfield, #03-1964 Page 1 From: Brian Henry To: Elmendorf, Katy Date: 10/8/2003 4:19:13 PM Subject: Insulation request inspection result, 3706 Springfield, #03-1964 Print for File Inspected insulation, 3706 Springfield, #03-1964, Mainstreet Homes, 10-8-03 Inspection result: Inspected OK for Good Cents CC: Alford, Mandi CITY OF COLLEGE STATION,, WORF ;QUEST PAGE 1 REQ/JOB: WF0421981 / u01 PROJECT: REQUEST DATE: DATE:03 6�26�PRINT CREW: PRINT TIME: 16:15:30 SCHSTAR.DAT ES LOCATION: 3706 SPRINGFIELD DR T6/26/03 77845 COMPLETION: 6726703 GEN. LOC: COLLEGE STATION LOC ID: 196376 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: MAIN STREET HOMES ORIGIN: CUSTOMER -WALK IN USER D: LLONG AUTH: LLONG WORK TYPE: ROUTINE 3I%4"WTR,4"SWR ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 3/4"WTR,4"SWR Category code CS -CUSTOMER SERVICES CSCS Task code: . SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE il MY] c 4PF COLL GE STATIC 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001964 Date 6/26/03 Property Address . . . . . . 3706 SPRINGFIELD DR Property ID . . 650700-0204-0040 R # . . . . . . . . . . . . . R114125 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD ADDITION PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 96294 Owner Contractor ------------------------ MAIN STREET HOMES ------------------------ CS LTD MAIN STREET HOMES o MSH-CS INC RICK JENKINS PETER L DAVIS 7447 BEE CAVES RD STE 150 7447 BEE CAVE ROAD #150 AUSTIN TX 787464130 AUSTIN TX 78746 (512) 690-9964 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1459.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . MR Permit Fee . . . . 448.00 Plan Check Fee .00 Issue Date . . . . 6/26/03 Valuation . . . . 96294 Expiration Date . . 12/23/03 Qty Unit Charge Per Extension BASE FEE 260.00 47.00 4.0000 THOU BLDG, VAL 50001-100000 188.00 ---------------------------------------------------------------------------- Special Notes and Comments PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR (S) IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED IOR BUILDING DEPT REPRESENTATIVE: APPLICANT: w -BUILDING PERMIT OF COLLEGE STATIC 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 2 Application Number . . . . . 03-00001964 Date 6/26/03 ---------------------------------------------------------------------------- Special Notes and Comments TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Permit Fee Total 448.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1198.00 Paid Credited Due --------------------------- 448.00 .00 .00 .00 .00 .00 750.00 .00 .00 1198.00 .00 .00 --------------------------------- ---------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: ADDRESS/LOCA LOT q ✓ AJ?P1LaIQAT1ON FOR BUILDING PERMI I CITY OF�COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US 1�- 3704 5 �.� ►rJ6 fit= �� BLOCK v SUBDIVISION BUSINESS/OWNER NAME: CONTRACTOR/HOMEOWNER: Main Street Homes CONTRACTOR ADDRESS: Westfield For O fw My UUse O DATE & ' b ' 0 (—�5 APPUCATI a = 01 �✓ TEMP P # e . PHONE: PHONE: (512) 327-8620 7447 Bee Cave Rd., Austin, TX 78746 ELECTRICIAN: Hillco Electric HVAC: Barkers HVAC PLUMBER: CP Plumbing GOOD CENTS (Residendal only): 90 CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: Construct Single Family Residence STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJ CT REGISTRATION# EABPRJ VALUATION: $ O (I TOTAL AREA: 9 S HEATED AREA: I�/S ( bor and dais) PUBLIC SEWER NUMBER OF BEDROOMS: 3 SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: 1.91 ® SEWER TAP: 4" INTERIOR WALL TYPE: Wood / Sheetrock S¢E X� WATER TAP: 3/4" EXTERIOR WALL TYPE: Wood/ Masonry SME OTHER TAP: FOUNDATION TYPE: Post Tension on Grade SIZE TEMP POLE ROOF TYPE: Asphalt Shingles GARAGE TYPE: SINGLE F_� DOUBLE ® TRIPLE a ATTACHED ® DETACHED F__j CARPORT a SIGNATURE OF APPLICANT., Of#vial Use Only ments: I n1 d 3 YES or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls R �� Insulation R value of ceiling 1 (flat areas) R 30 Insulation R value of ceiling 2 (vaulted areas/no attic) Q` 2 Z- Glazing SHGC r U Glazing U-Factor Zq R value of ductwork A/C SEER rating 2 REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release la Data filename: F:\Root\Mainstreet\Share\Construction\MECcheck\1459-CS.cck TIME: 1459 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 06/17/03 COMPANY INFORMATION: Main Street Homes, Ltd COMPLIANCE: Passes Maximum UA = 425 Your Home UA = 284 33.2% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.36 Ceiling 1: Cathedral Ceiling (no attic) Ceiling 2: Flat Ceiling or Scissor Truss Wall 1: Wood Frame, 16" o.c. Window 1: Metal Frame, Double Pane SHGC: 0.36 Door 1: Solid Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air,12 SEER Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 149 22.0 0.0 7 1459 0.0 30.0 45 1600 15.0 0.0 107 155 0.640 99 58 0.450 26 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 MCC requirements in REScheckVersion 3.5 Release la (formerly MECchec4 and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date REScheck Inspection Checklist G 2000 IECC REScheckSoflware Version 3.5 Release la DATE: 06/17/03 TITLE: 1459 Bldg. Dept. Use Ceilings: [ ] 1. Ceiling 1: Cathedral Ceiling (no attic), R-22.0 cavity insulation Comments: [ ] 2. Ceiling 2: Flat Ceiling or Scissor Truss, R-30.0 continuous insulation I Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R-15.0 cavity insulation Comments: Windows: 1. Window 1: Metal Frame, Double Pane, U-factor. 0.640 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: [ ] 1. Door 1: Solid, U-factor. 0.450 Comments: Heating and Cooling Equipment: [ ] 1. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number [ ] 2. Air Conditioner 1: Electric Central Air,12 SEER or higher Make and Model Number Solar Heat Gain Coefficient: [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed [ ] Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordance with the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined [ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided [ ] Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must -be insulated to R 5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 T or chilled fluids below 55 T must be insulated to the I levels in Table 2. • , f Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature Low Temperature Steam Condensate (for feed water) Cooling Systems Chilled Water, Refrigerant, and Brine 201-250 1.0 1.5 1.5 2.0 120-200 0.5 1.0 1.0 1.5 Any 1.0 1.0 1.5 2.0 40-55 0.5 0.5 0.75 1.0 Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)