3 - lq6s 1� PREPARED 11/10/03, 7:01:58 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 11/10/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 1086 WINDMEADOWS DR SUBDIV: WESTFIELD VILLAGE PH 1 CONTRACTOR STYLECRAFT BUILDERS PHONE : (979) 690-1222 OWNER BCS DEVELOPMENT CO PHONE : PARCEL 650730-0102-0410 APPL NUMBER: 03-00001955 RESIDENTIAL, 1 UNIT DETACHED NEW PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS B100 01 6/26/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 6/27/03 AP 06/26/2003 09:22 AM SSTANLEY SLAB GROUND BACK LEFT. SETBACK STRINGS PULLED. B1__ 01 8/18/03 CH BLDG, FRAMING TIME: 17:00 8/18/03 AP 08/18/2003 09:12 AM KELMENDORF B130 01 8/20/03 CH BLDG, INSULATION TIME: 17:00 8/20/03 AP 08/19/2003 01:30 PM MALFORD B125 01 11/1 /03 BI BLDG, FINAL TIME: 17:00 G4, A(% AvL) S 11/07/2003 03:59 PM GCARRILLO ------------ 03------------ � ------ COMMENTS AND NOTES-------------------------------------- �-- CITY OF COLLEGE STATION WORK QUEST PAGE 1 REQ/JOB: WF0424059 / 001 PROJECT: REQUEST DATE: 1--17 3/03 PRINT DATE: 7/03/03 CREW: PRINT TIME: 11:53:57 SCHSTAARRT: DATES LOCATION: 1086 WINDMEADOWS DR 7)(03/03 77845 COMPLETION: 7/03/03 GEN. LOC: COLLEGE STATION LOC ID: 195866 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE 07/24/2003 THU 09:54 FAX. 979 690 0348 STYLECRAFT BUILDERS INC Q 002/002 L 07/24/03 To Whom This May Concern: I'm am writing this letter on behalf of Stylecraft Builders, Inc. in order to inform you of a change on the IIVAC permit of our job at 1086 Windmeadows. We originally listed Control Temp to do this project, and it has since been changed to Nacho Mosqueda. Please let me know if there is anything further needed from me, and I am sorry for any inconvenience this may have caused, Thank you, Eric Wivagg"` Architectural Designer Stylecraft Builders, Inc. CITY OF COLLEGE STATION WORK" �'EQUEST PAGE 1 REQ/JOB: WF0420125 , 01 PROJECTS REQUEST DATE: 6/23/03 PRINT DATE: 6/23/03 CREW: PRINT TIME: 10:33:21 SCHSTAARRT.DATES LOCATION: 1086 WINDMEADOWS DR 6/23/03 77845 COMPLETION: 6723703 GEN. LOC: COLLEGE STATION LOC ID: 195866 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: STYLECRAFT BLDRS (690-1222) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE y . a BUILDING PERMIT WY OF CO•LII.EGE. STATLON.. �Y� W �_ -AVE ..:.�... COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001955 Date 6/23/03 Property Address . . . . . . 1086 WINDMEADOWS DR Property ID . . . . . . . . . 650730-0102-0410 R # . . . • • . • . . . . . . R113358 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 86592 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ------ Structure Information SINGLE FAMILY ----- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 HEATED AREA 1312.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 248.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . LL Permit Fee . . . . 408.00 Plan Check Fee .00 Issue Date . . . . 6/23/03 Valuation . . . . 86592 Expiration Date . . 12/20/03 Qty Unit Charge Per Extension BASE FEE 260.00 37.00 4.0000 THOU BLDG, VAL 50001-100000 148.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT ----------------------------------------- ---- -- ------------------------- BUILDING DEPT REPRESENT^-ATIVE APPLICANT: �� / BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001955 Page 2 Date 6/23/03 Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR EXIT DOOR(S) MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS) PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. POST PERMIT CARD ON JOB SITE For residential applications with a glazing area that exceeds 15% of the gross area of exterior walls, R-8 duct insulation is required. As an alternative, R-6 duct insulation can be used if the a/c system has a SEER rating of 12 or more. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120 DEGREES ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES need to check with electrical department about service location Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited Due --------------------------------------------------------- Permit Fee Total 408.00 408.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 -------------------------------------- - - --------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: y BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Page 3 Application Number . . . . . 03-00001955 Date 6/23/03 Grand Total 1158.00 1158.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001956 Date 6/23/03 Property Address . . . . . . 1086 WINDMEADOWS DR Property ID 650730-0102-0410 R # . . . . . . . R113358 Application description . . . TEMP POLE Subdivision Name . . . . . . WESTFIELD VILLAGE PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ BCS DEVELOPMENT CO ------------------------ STYLECRAFT BUILDERS 4090 SH-6 S RANDY FRENCH COLLEGE STATION TX 77845 4060 SH 6 SOUTH COLLEGE STATION TX 77845 (979) 690-1222 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . LL Permit Fee . . . . 20.00 Issue Date . . . . 6/23/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged ---------- Paid Credited ------------------------------ Due ----------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: ��� ��— IPPA �om. u. o* APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW.CI.COLLEGE-STATION.TX.US _.TE: IO 1 -03 APPLICATION # v � TEMP POLE # IO45 ADDRESS/LOCATION: � � I ej a PHASE LOTj(�CK SUBDIVISION `�' BUSINESS/OWNER NAME: STYLECRAFT BUILDERS INC. PHONE: 690-1222 ext. 20 CONTRACTORIHOMEOWNER: STYLECRAFT BUILDERS INC. PHONE: 690-1222 ext. 20 CONTRACTOR ADDRESS: 4090 State Hi hwa 6 South ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plum bin HVAC: Control Temp GOOD CENTS (Residential on No CLASS OF WORK LOCATION RE -ROOF (Total/Partial) ACCESSORY/STORAGE ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) N NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req)REMODEURENOVATION F SWIMMING POOL DESCRIPTION OF WORK: Conventional Framing STRUCTURE USE: Single Family Residence HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROV WA TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 805q;?• 0() 1/ TOTAL AREA: 1-143q HEATED AREA: (Cost of Labor and Materials) QX PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: FX SEWER TAP: 4' INTERIOR WALL TYPE: Sheet Rock FX�WATER TAP: SIZE +° 3/ EXTERIOR WALL TYPE: Siding and/or Masonry OTHER TAP: SIZE FOUNDATION TYPE: Slab on Grade 5X1 TEMP POLE SIZE ROOF TYPE: Composition GARAGE TYPE: SINGLE r__j DOUBLE [:0 TRIPLE F7 ATTACHED FX DETACHED F__j CARPORT F7 SIGNATURE OF APPLICANT: Official Use Only ments: YES rN0 C_ rl Plans Examiner Zoning official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls R13 Insulation R value of ceiling 1 (flat areas) R30 Insulation R value of ceiling 2 (vaulted areas/no attic) R19 Glazing SHGC .40 Glazing U-Factor .65 R value of ductwork R6 A/C SEER rating 12 REScheck Compliance Certificate 2000 IECC REScheckSoftware Version 3.5 Release lc Data filename: S:\ACAD\REScheck\l320 Select.cck TITLE: PLAN #1320 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 06/17/03 DATE OF PLANS: 6/17/03 PROJECT INFORMATION: West Field Village 1086 Windmeadows College Station, Texas COMPANY INFORMATION: Stylecraft Builders, Inc. 4090 St. Hwy. 6 S. College Station, Texas 77845 COMPLIANCE: Passes Maximum UA = 483 Your Home UA = 416 13.9% Better Than Code (UA) Maximum SHGC = 0.40 Your SHGC = 0.40 Ceiling 1: Flat Ceiling or Scissor Truss Ceiling 2: Cathedral Ceiling (no attic) Wall 2: Wood Frame, 16" o.c. Window 4: Metal Frame, Double Pane with Low-E SHGC: 0.40 Door 3: Solid Door 4: Solid Door 5: Solid Floor 1: Slab-On-Grade:Unheated Insulation depth: 0.0' Air Conditioner 1: Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA 1030 30.0 0.0 36 290 19.0 0.0 15 1168 13.0 0.0 78 158 0.670 106 20 0.500 10 18 0.580 10 18 0.500 9 146 0.0 152 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with t] rmit application. The proposed building has designed to meet the 2000 IECC requirements in RES checkVersion 3.5 Release lc (formerly MECchec.� and to comply with the mandatory requirements listed in the RES checkInspection Checklist. Builder/Designer Date r REScheck Inspection Che--__st 2000 IECC REScheckSoftware Version 3.5 Release lc DATE: 06/17/03 TITLE: PLAN #1320 Bldg. I Dept. I Use I I I [ ] I I [ ] I I I I [ ] I I I i Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 2: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: Windows: 1. Window 4: Metal Frame, Double Pane with Low-E, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 3: Solid, U-factor: 0.500 Comments: 2. Door 4: Solid, U-factor: 0.580 Comments: 3. Door 5: Solid, U-factor: 0.500 Comments: Floors: 1. Floor 1: Slab-On-Grade:Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: Materials and equipment mus nstalled in accordance with the manufacturer tallation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. I Duct Insulation: [ ] I Ducts in unconditioned spaces must be insulated to R-5. I Ducts outside the building must be insulated to R-8.0. I I Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics I (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. I Exception: Continuously welded and locking -type longitudinal joints and seams on ducts I operating at less than 2 in. w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Circulating Hot Water Systems: [ ] I Insulate circulating hot water pipes to the levels in Table 1. I I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% 1 of the heating energy is from non-depletable sources. Pool pumps require a time clock. I I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the I levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) Area Calculator: Window- Name Comrr�ents/ Description Window Area Total: 157.67 06/17/03 09:58:38 1 /1 Area Calculator: =MImImffim=m Commentsi Description Opaque door solid Door Area Total: 55.56 06/17/03 09:58:40 1/1 Area Calculator: Assembly Type Mr. MIMMMMW�-, WMI © .. ,,, ■�M ,,,, Ceiling Area Total: 1320.00 06/17/03 09:58:41 1/1 Area Calculator: Assembly Type ME M-MEMMIMMMM, Comments/Description Exterior Wall Area Total: 1168.00 06/17/03 09:58:42 1/1 Area Calculator: Comments/Description Ism �■�■�� Floor Area Total: 0.00 06/17/03 09:58:42 1/1