HomeMy WebLinkAboutRES2003-01953CITY OF COLLEGE STATION
WORK VEQUEST
r PAGE
1
REQ/JOB:
a
WF0420129 01.
.REQUEST DATE:
6/23/03
i
.PRINT DATE:
6/23703
CREW:
PRINT TIME:
10:37:55
SCHSTART.DATES
LOCATION:
3915 SPRINGMIST DR
6/23/03
77845
COMPLETION:
6723703
GEN. LOC:
COLLEGE STATION LOC ID: 195718
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
STYLECRAFT BLDRS (690-1222) ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG WORK TYPE:
ROUTINE
4" SEWER
AND 3/4" WATER
4" SEWER AND 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
PREPARED 2/23/04, 12:06:19 INSPECTION TICKET PAGE 4
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 2/23/04
------------------------------------------------------------------------------------------------
ADDRESS . : 3915 SPRINGMIST DR SUBDIV: WESTFIELD VILLAGE PH 1
CONTRACTOR : STYLECRAFT BUILDERS PHONE (979) 690-1222
OWNER : BCS DEVELOPMENT CO PHONE
PARCEL : 650730-0101-0360
APPL NUMBER: 03-00001953 RESIDENTIAL, 1 UNIT DETACHED NEW
-------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 7/03/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00
7/03/03 AP 07/02/2003 03:53 PM KELMENDORF
missed yesterday, please do as quickly as possible
SLAB GROUND RIGHT SIDE. SETBACK STRINGS PULLED
B115 01 8/20/03 CH BLDG, FRAMING TIME: 17:00
8/21/03 AP 08/20/2003 03:49 PM KELMENDORF
fireblock wall between kitchen and living room
fireblock above fireplace
BlA1 8/22/03 CH BLDG, INSULATION TIME: 17:00
8/25/03 AP 08/22/2003 11:16 AM KELMENDORF
B1 2 2 /04 BI BLDG, FINAL TIME: 17:00 ( yj
02/23/2004 08:07 AM GCARRILLO
-- _ all Oul, bgPI AP
_
------------------------------ COMMENTS AND NOTES --------------------------------------
08/11/2003 MON 12:16 FAX. 979 690 0348 STYLECRAFT BUILDERS INC
I2 002/002
08/11/03
To Whom This May Concem:
I'm am writing this letter on behalf of Stylecraft Builders, Inc. in order to inform
you of a change on the HVAC permit of ourjob at 3905 Springmist. We originally listed
Control Temp to do this project, and it has since been changed to Nacho Mosqueda.
Please let me know if there is anything further needed from me, and I am sorry for any
inconvenience this may have caused.
Thank yyou,
Eric Wivagg
Architectural Designer
Stylecraft Builders, Inc,
CITY OF COLLEGE STATION
WORK REQUEST
REQ/JOB: WF0424057 / 00,1 PROJECT:
CREW:
LOCATION: 3915 SPRINGMIST DR
PAGE 1
- REQUEST DATE: 7/03/03
PRINT DATE: 7/03/03
PRINT TIME: - 11 :-5.2 : 2 6
SCHEDULE DATES
START: 7/03/03
77845 COMPLETION: 7703703
GEN. LOC: COLLEGE STATION LOC ID: 195718
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: STYLECRAFT BUILDERS ORIGIN: CUSTOMER -WALK IN
USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
Li
BUILDING PERMIT
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00001953
Date 6/23/03
Property Address . . .
. . . 3915 SPRINGMIST DR
Property ID
. . 650730-0101-0360
R # . . . . . . . . . .
. . . R113317
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . WESTFIELD VILLAGE PH 1
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . SINGLE FAMILY RESIDENTIAL
Application valuation .
. . . 101970
Owner
Contractor
------------------------
BCS DEVELOPMENT CO
------------------------
STYLECRAFT BUILDERS
4090 SH-6 S
RANDY FRENCH
COLLEGE STATION TX
77845 4060 SH 6 SOUTH
COLLEGE STATION
TX 77845
(979) 690-1222
------ Structure Information
SINGLE FAMILY
-----
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
HEATED AREA
1545.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
SERIAL ZONES
248.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . LL
Permit Fee . . . .
466.00 Plan Check Fee
.00
Issue Date . . . .
6/23/03 Valuation . .
. . 101970
Expiration Date . . 12/20/03
Qty Unit Charge Per Extension
BASE FEE 460.00
2.00 3.0000 THOU BLDG, VAL 100001-500000 6.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE EXTERIOR LANDING LEVEL WITH THE INTERIOR FLOOR FOR
BUILDING DEPT REPRESENTATIVE:
APPLICANT: jam`
BUILDING PERMIT
». CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00001953
Page 2
Date 6/23/03
Special Notes and Comments
EXIT DOOR (S)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
POST PERMIT CARD ON JOB SITE
For residential applications with a glazing area that
exceeds 150 of the gross area of exterior walls, R-8 duct
insulation is required. As an alternative, R-6 duct
insulation can be used if the a/c system has a SEER rating
of 12 or more.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH
AN ANTI -SCALD VALVE THAT LIMITS WATER TEMPERATURE TO 120
DEGREES
ALL SILLS AND BOTTOM PLATES IN CONTACT WITH CONRETE MUST BE
TREATED OR NATURALLY RESISTANT TO INSECTS AND DECAY
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED
SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN
PRIVATE GARAGES
Other Fees . . .
. . . . . .
SEWER TAP
4" CITY INSTALL
350.00
WATER TAP
3/4" CITY INSTL
400.00
Fee summary
-----------------
Charged
----------
Paid
----------
Credited
--------------------
Due
Permit Fee Total
466.00
466.00
.00
.00
Plan Check Total
.00
.00
.00
.00
Other Fee Total
750.00
750.00
.00
.00
Grand Total
1216.00
1216.00
.00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT:
TEMPORARY POLE PERMIT
' CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . .
. . .
03-00001954 Date
6/23/03
Property Address . . .
. . .
3915 SPRINGMIST DR
Property ID
650730-0101-0360
R # . . . . . . .
R113317
Application description
. . .
TEMP POLE
Subdivision Name . . .
. . .
WESTFIELD VILLAGE PH 1
Property Use . . . . .
. . .
RESIDENTIAL
Property Zoning . . . .
. . .
SINGLE FAMILY RESIDENTIAL
Application valuation .
. . .
0
Owner
Contractor
------------------------
BCS DEVELOPMENT CO
------------------------
STYLECRAFT BUILDERS
4090 SH-6 S
RANDY FRENCH
COLLEGE STATION TX
77845
4060 SH 6 SOUTH
COLLEGE STATION
TX 77845
(979) 690-1222
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . LL
Permit Fee . . . .
20.00
Issue Date . . . .
6/23/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . .
. . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
----------
Paid Credited
------------------------------
Due
-----------------
Permit Fee Total
20.00
20.00 .00
.00
Other Fee Total
45.00
45.00 .00
.00
Grand Total
65.00
65.00 .00
.00
BUILDING DEPT REEP-RREESENTATIVE:
APPLICANT: �L%
At!
APPLICATION FOR BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEGE-STATION.TX.US
Fbr ofte Uw ony
DATE: (0 - 11-03
APPLICATION # D J _ I -1 63
TEMP POLE # o ,3 I R5q
ADDRESS/LO�ATION:3 L5 'S ICY)I sT Di • l,D11eQe S ► T 7 I �`1
LOT 3kO ,BLOCK SUBDIVISION V ]CS 1 Ptri PHASE
BUSINESS/OWNER NAME: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20
CONTRACTOR/HOMEOWNER: STYLECRAFT BUILDERS, INC. PHONE: 690-1222 ext. 20
CONTRACTOR ADDRESS: 4090 State Hiahwav 6 South
ELECTRICIAN: Brazos Valley Electric PLUMBER: Bass Plumbing
HVAC: Control Temp GOOD CENTS (Residential only): No
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) X NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Conventional Framing
STRUCTURE USE: Sinale Family Residence
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (_T%AS) PROJECT REGISTRATION# EABPRJ N/A
VALUATION: $ 101 A 70- UO v TOTAL AREA:DD 3 HEATED AREAJ G45
(Cost of Labor and Materials)
QX PUBLIC SEWER
❑ SEPTIC/TREATMENT SYSTEM
QX
SEWER TAP:
4"
SIZE
QX
WATER TAP:
Y4"
SIZE
OTHER TAP:
SIZE
QX
TEMP POLE
GARAGE TYPE:
SINGLE
ATTACHED
SIGNATURE OF APPLICANT:
Plans Examiner
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
ROOF TYPE
3
Sheet Rock
Siding and/or Masonry
Slab on Grade
Composition
DOUBLE [Z TRIPLE a
FX DETACHED F-1 CARPORT
Official Use Only
Zoning Official
m ents:
YES r NO
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls R13
Insulation R value of ceiling 1 (flat areas) R30
Insulation R value of ceiling 2 (vaulted areas/no attic) R19
Glazing SHGC .40
Glazing U-Factor .65
R value of ductwork R6
A/C SEER rating 12
1 sill
REScheck Compliance Certificate
2000 IECC
REScheckSoftware Version 3.5 Release lc
Data filename: S:\ACAD\REScheck\1545—Porch.eck
TITLE: Plan # 1545 Porch
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 06/17/03
DATE OF PLANS: 6/17/03
PROJECT INFORMATION:
spec
3815 Springmist
College Station, TX 77845
COMPANY INFORMATION:
Stylecraft Builders, Inc.
4090 St. Hwy. 6 S.
College Station, Texas 77845
COMPLIANCE: Passes
Maximum UA = 611
Your Home UA = 526
13.9% Better Than Code (UA)
Maximum SHGC = 0.40
Your SHGC = 0.40
Ceiling 1: Flat Ceiling or Scissor Truss
Ceiling 2: Cathedral Ceiling (no attic)
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane with Low-E
SHGC: 0.40
Door 1: Solid
Door 2: Glass
SHGC: 0.40
Floor 1: Unheated
Insulation depth: 0.0'
Air Conditioner 2: Electric Central Air, 12 SEER
Furnace 2: Forced Hot Air, 80 AFUE
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
1067
30.0 0.0
37
466
19.0 0.0
24
1455
13.0 0.0
98
201
0.670 135
38
0.500 19
18
0.580 10
195
0.0
203
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with th rmit application. The proposed building has designed to meet the 2000 IECC
requirements in RES checkVersion 3.5 Release lc (formerly MECchenl and to comply with the mandatory requirements listed in
the RES checkInspection Checklist.
Builder/Designer Date
REScheck Inspection Chec.ist
2000 IECC
REScheckSoftware Version 3.5 Release lc
DATE: 06/17/03
TITLE: Plan # 1545 Porch
Bldg. I
Dept. I
Use I
i
I Ceilings:
[ ] 1 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
I Comments:
[ ] 1 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation
I Comments:
I
I Above -Grade Walls:
[ ] 1 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
I Comments:
I
I Windows:
[ ] 1 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.670
1 For windows without labeled U-factors, describe features:
I # Panes Frame Type Thermal Break? [ ] Yes [ ] No
I Comments:
I
I Doors:
[ ] 1 1. Door 1: Solid, U-factor: 0.500
1 Comments:
[ ] 1 2. Door 2: Glass, U-factor: 0.580
1 Comments:
I
I Floors:
[ ] 1 1. Floor 1: Unheated, R-0 (uninsulated)
I Comments:
I
I Heating and Cooling Equipment:
[ ] 1 1. Air Conditioner 2: Electric Central Air, 12 SEER or higher
I Make and Model Number
[ ] 1 2. Furnace 2: Forced Hot Air, 80 AFUE or higher
I Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined.
Manufacturer manuals for all lied heating and cooling equipment and servi ater heating
equipment must be provided.
Insulation R-values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
Duct Insulation:
Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R-8.0.
I Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
I (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
I Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
I operating at less than 2 in. w.g. (500 Pa).
[ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I
I Temperature Controls:
[ ] I Thermostats are required for each separate HVAC system. A manual or automatic means to
I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
I Service Water Heating:
[ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
I water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
I Circulating Hot Water Systems:
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
I
I Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
1 of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I
I Heating and Cooling Piping Insulation:
[ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
I levels in Table 2.
I
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp.
Insulation Thickness in Inches by
Pipe Sizes
Piping System Types
Range (F)
2" Runouts
V and Less
1.25"
to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
Area Calculator:
Window I
Name
Assembly Type:=MIMIMMMMM
Comments/
Description
Window Area Total: 200.84
06/17/03 09:18:29 1/1
Area Calculator:
190=10�
Assembly Type
Comments/
Description
,Opaque door solid
Door Area Total: 35.56
06/17/03 09:18:31 1/1
Area Calculator:
Ceiling Area Total: 1533.00
06/17/03 09:18:32 1/1
Area Calculator:
Assembly Type
Comments/Description
Exterior Wall Area Total: 1455.33
06/17/03 09:18:32 1/1
Area Calculator:
Assembly .:
MWComments/Description
Floor Area Total: 0.00
06/17/03 09:18:33 1/1