HomeMy WebLinkAboutRES2003-01907031-101'
PREPARED
12/19/03, 7:13:42
INSPECTION TICKET
PAGE 7
City of
College Station
INSPECTOR: BUILDING INSPECTOR
DATE 12/19/03
------------------------------------------------------------------------------------------------
ADDRESS
. : 3731 ESSEN LOOP
SUBDIV: EDELWEISS
GARTENS PH 1
CONTRACTOR OAKWOOD CUSTOM HOMES PHONE : (979) 690-1504
OWNER
OAKWOOD CUSTOM HOME
BUILDERS PHONE :
PARCEL
244030-0101-0300
APPL NUMBER: 03-00001907 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
7/17/03 DS
BLDG, FOUNDATION -SLAB TIME: 17:00
7/18/03 AP
AFTERNOON PLEASE
07/16/2003 01:36 PM LLONG
STRINGS ON SET BACKS, OK. SLAB GROUND
BACK LEFT CORNER.
B115 01
9/03/03 CH
BLDG, FRAMING TIME: 17:00
9/03/03 AP
09/03/2003 09:51 AM MALFORD
09/03/2003 04:40 PM MALFORD
vent exhaust fans , window upstairs next to bathroom door
needs to be tempered
B125 01
12/19/03
BLDG, FINAL TIME: 17:00
12/18/2003 03:50 PM SSTANLEY
OTHER FINALS DONE!
�I
--------------------------------------
COMMENTS AND NOTES-------------�1------------------------
V" �f $
CITY OF COLLEGE STATION
WORK REQUEST
PAGE 1
REQ/JOB:
WF0424505 / 001 PROJECT:
REQUEST DATE:
7/07/03
PRINT DATE:
7/07/03
CREW:
PRINT TIME:
12:11:16
SCHSTARRT.DATE/07/03
DULLOCATION:
3731 ESSEN LOOP
77845
COMPLETION:
7/07/03
GEN. LOC:
COLLEGE STATION LOC ID: 193852
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
OAKWOOD HOMES (690-1504) ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG WORK TYPE:
ROUTINE
TEMP POLE
PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
Mandi Alford - Insulation request inspec" n result, 3731 Essen Loop, #03-1907 Page 1
From: Brian Henry
To: Elmendorf, Katy
Date: 9/8/2003 4:10:23 PM
Subject: Insulation request inspectionm result, 3731 Essen Loop, #03-1907
Print for File
Inspected insulation, 3731 Essen Loop, #03-1907, Oakwood Homes, 9-9-03
Inspection result: Inspected Ok for Good Cents
CC: Alford, Mandi
CITY OF COLLEGE STATION
WORM ;QUEST
PAGE
1
REQ/JOB:
WF0422006 / 001 PROJECT:
REQUEST DATE:
6�26%PRINT 03
CREW:
PRINT TIME:
16:27:02
SCHSTAARRT.DATES
LOCATION:
3731 ESSEN LOOP
6/26/03
77845 COMPLETION:
6/26/03
GEN. LOC:
COLLEGE STATION LOC
ID: 193852
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION
PRIORITY: NORMAL
REQUESTOR:
OAKWOOD CUSTOM HOMES
ORIGIN: CUSTOMER -WALK
IN
USER D:
LLONG AUTH: LLONG
WORK TYPE: ROUTINE
3�4"WTR,4"SWR
3/4"WTR,4"SWR
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
--� • BUILDING PERMIT.
1101 AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00001907 Date 6/26/03
Property Address . .
. . . . 3731 ESSEN LOOP
Property ID
. . 244030-0101-0300
R # . . . . . . . . .
. . . . R111668
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . EDELWEISS GARTENS PH 1
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 120000
Owner
Contractor
------------------------ ------------------------
OAKWOOD CUSTOM HOME BUILDERS OAKWOOD CUSTOM HOMES
L.L.C.
ALTON OFCZARZAK
PO BOX 9849
PO BOX 9849
COLLEGE STATION
TX 778427849 COLLEGE STATION TX 77842
(979) 690-1504
--------------------------
Structure Information -------------------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 2.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 1781.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 2.50
NUMBER OF BEDROOMS 3.00
SEWER TYPE PUBLIC
SERIAL ZONES 247.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc
MR
Permit Fee
520.00 Plan Check Fee .00
Issue Date
6/26/03 Valuation . . . . 120000
Expiration Date
12/23/03
Qty Unit Charge
Per Extension
BASE FEE 460.00
20.00 3.0000
THOU BLDG, VAL 100001-500000 60.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTER (S )
BUILDING DEPT REPRESENTATIVE:
APPLICANT: G-�
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number 03-00001907
Page 2
Date 6/26/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
GUARDS SHALL COMPLY WITH SECTION R-316 (2000 IRC) OR SECTION
1003.2.12 (2000 IBC) AS APPROPRIATE
HANDRAILS SHALL COMPLY WITH SECTION R-315 (2000 IRC) OR
SECTION 1003.3.11 (2000 IBC) AS APPROPRIATE
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
Ir' LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
POST PERMIT CARD ON JOB SITE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
STAIRS SHALL COMPLY WITH SECTION R-314 (2000 IRC) 0 ECTION
BUILDING DEPT REPRESENTATIVE:
APPLICANT: �—I- —
BUILDING PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number . . . . .
03-00001907 Date
6/26/03
----------------------------------------------------------------------------
Special Notes and Comments
1003.3.3 (2000 IBC) AS APPROPRIATE
AN APPROVED DEVICE FOR THERMAL
EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
Note from electrical division:
Electrical service shall be
on the left side of structure. (see site plan)
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4" CITY INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged
---------------------------
Paid Credited Due
------------------------------
Permit Fee Total 520.00
520.00 .00
.00
Plan Check Total .00
.00 .00
.00
Other Fee Total 750.00
750.00 .00
.00
Grand Total 1270.00
1270.00 .00
.00
BUILDING DEPT REPRESENTATIVE:
APPLICANT: / h
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATION
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
03-00001908 Date 6/26/03
Property Address . . . . . .
3731 ESSEN LOOP
Property ID . . . . . . . . .
244030-0101-0300
Application description . . .
TEMP POLE
Subdivision Name . . . . . .
EDELWEISS GARTENS PH 1
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation
0
Owner
Contractor
------------------------
OAKWOOD CUSTOM HOME BUILDERS
------------------------
OAKWOOD CUSTOM HOMES
L.L.C.
ALTON OFCZARZAK
PO BOX 9849
PO BOX 9849
COLLEGE STATION TX 778427849
COLLEGE STATION
TX 77842
(979) 690-1504
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . MR
Permit Fee . . . . 20.00
Issue Date . . . . 6/26/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
------------------------------------xt�--
--------------
BUILDING DEPT REPRESENTATIVE:
APPLICANT: r ry�
Fbr Oft* Use 0*
ArrLICATION FOR BUILDING PERM I
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX.US
ADDRESS/LOCATION: 3 7 31 E S S e v► L DO,d
DATE. 6-11-C 2'
APPUCATiON * 0 L 19 91
TEMP POLE # 03 —m O
LOT 30 BLOCK I SUBDIVISION a=d e l we ► s s Oa rfe yr s
BUSINESS/OWNER NAME: 0a l4 wood Cu S4ovN (-lo, .n e- b(.ri kev5 PHONE: G qO ISO Y
CONTRACTOR/HOMEOWNER:
If,
PHONE: II
CONTRACTOR ADDRESS: y0&0 6 Col%!)e V-t4io-, *t IC 77 6c/57-
ELECTRICIAN: i se PLUMBER: Tie la "W 4/µ ft,
HVAC: Th rce Ai vee S C 114-*4e CyN+ro / GOOD CENTS (Residential only): Ve!
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: Twc Sf or �l ,.� ew L Dv� 5 tru c�; oN
STRUCTURE USE: j,r,�w►b,er
Si-r�cl�.re
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 12.0, d CO v
TOTAL AAREA: HEATED AREA: 17 I
(Cost of Labor and Materials)
Eg"P/UBLIC SEWER
NUMBER OF BEDROOMS: J
SEPTIC/TREATMENT SYSTEM
NUMBER OF BATHROOMS:
�EWER TAP: ¢� I
INTERIOR WALL TYPE: 3
SizE
ER'WATER TAP: W4_
I �,
EXTERIOR WALL TYPE: 3 Z.
SME
OTHER TAP:
/
FOUNDATION TYPE: $ICA 0k1 G raul2
Sim
12-TEMP POLE
ROOF TYPE: j�r�hiec��.t 1 S�nr` f rs IA/2aiIG/1r woe
GARAGE TYPE: SINGLE
DOUBLE d TRIPLE a
ATTACHED
DETACHED a CARPORT a
SIGNATURE OF APPLICANT:
° II
&t.,) 6
Ofirclal Use Only Pe%menu:
l ��W
(y9=15or NO
Plans Examiner
Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls 1 Z 7
Insulation R value of exterior walls / 3
Insulation R value of ceiling I (flat areas) 30
Insulation R value of ceiling 2 (vaulted areas/no attic) 30
Glazing SHGC • 3 q
Glazing U-Factor , l', S
R value of ductwork (0,0
A/C SEER rating 1 2-
C(1LL•E`STA'IQN'5 G40D MN-NEY >OME`�lPPI:IC�;.�IOlu. '.
_ Please'c�opiplcte*ad i_ urwntot'ei.and -set :ofb6in .picas
C'ty of Caltege Sf rm',
_ Public Ihiffities mpad mat' _
y - Enetu Couscrvatioa Iftvistoa
"-
Colt* �tafign rF 77842
s•' Gt�'o� Tate:' ! -
, T— iT
tl 4 L/
Builder: . t�7AIC�,►.oa�_
A iliiig Address' tli'1? :�� «�-a�.i ��v:� �p��#4�a`n� . '7 ':$tlS
Tel 64
Contact: '�- rt--�- fit°`
Co"ager,# — .
E-Maii Add..
7.. Date: 3'
'onecl ; ua0�: -oi •� =1.� "'stare
D"rd'e n Circle one)- E (r',=
n/On irtatio
__; •may _ _ _ _ _ _ - - - - . • __ _ _ _ , •
INSUL
#.•.fin' , nh` e1 ktonej.- �#
-_ ,Tnsulaticln�Conti�ctor, � -
' E tt L=alae
ail• B tt R value' 11;ftiiie:, a
w
�_'
- a;
'� • � -k value •'�y�o�' t-%. _
�l,eathiu --.`:�,�,_'i"6ic�ess•'
Dtwrs,, Wapu` Fiberglass' :Ivietal'' Cex..M h
bttct • Metal+_ IIuct; art _ 464pack
Flex- ' Tt vah�e , .� • fi '
Slab Pier&'Ream' " att°n--.t,iralia�e:' b
W� ,
GL
_ Trouble lane'l "
:iplo, Pane::,
Vin l: filar s6 eris' Lover E'
Conventional ' ' ETiiin tirduitd Source Feat Pump-
�-=� _ P .
t. ' a�le';+�a 'Ire Te li ne: f•� ia'S , j.1�1'�'`
HVAC_ContraciQ - �i�^e=,�"� Y �' l��r �H � �, o
$ _
L-
_ -" ",- `,•-�� we�y,� :Cti.� oRebateCheck Pyable To�mg•Address:&E1I��'+afer'FH" City,State,Z-p. ��1 f'
City of College Station GoodCents- Qualifying Criteria
GOOD CENTS, College Station's Energy Efficiency Program for new homes, is a flexible, perigrinance
based program that allows the future homeowner and homebuilder various combinations of energy
efficient, thermal and mechanical components to meet the Good Cents heat gain and air infiltration
requirements.
HEAT -GAIN
Analyses are performed on the construction plans when submitted with -the proper application at the
College Station Public Utility Energy Management offices. at 1601 Graham Road in College Station.
Maximum allowable calculated heatgain of 12.0 BTU's or less are required to'qualify for the Good
Cents Program. Energy Management -personnel are available to work with owners and builders to assist
in meeting criteria
INSULATION / INFILTRATION .
Insulation resistance values are to meet or exceed R 13 in walls, R-30 in attics and R-19 for pici and
beam floors. Upon completion of insulation installation and before drywall and/or brick and siding are
installed, Energy Management personnel must be -notified to perform a thorough insulation/infiltration
inspection. All insulation must be installed according to the manufacturer's instructions -and CUT -tightly
around all junction boxes and plumbing filling the entire stud area with no gaps. Insulation must be
installed during framing behind all tees and comers and behind any bathtub stalls installed before
'inspection- Appropriate R value batts must be installed before first inspection in all ceilings areas
impossible to reach during attic insulation installations.
A minimum of Vi"' insulating sheathing must be installed over exterior walls including wind bracing. All
sheathing joints must be sealed with thermal sheathing tape. Sole plates.must be caulked and all plumbing,
electrical, security and cable entries must be sealed at the top plate and at any sheathing intersections, All
gaps and penetrations in the thermal envelope must be sealed.
All windows must -be double -glazed. Low E glass is recommended but is not a requirement. Solar screens
are encouraged but will not be included in heat gain analyses since they are, not fixed. Windows must be -
sealed with expanding foam and the exterior taped with sheathing/window tape.
All,exterior doors must be solid wood, molded fiberglass, or metal polystyrene, urethane or fiberglass
filled: Weather-stripping .of all doors and windows must be completed before final inspection including any
interior attic access doors within the conditioned space.
HEATING / AIR CONDITIONING / VENTI LATION
Air,conditioning systems must have 12.0 or better SEER ratings and gas furnaces a minimum of 80
AFUE ratings.- Heat pumps systems must have a minimum of 12.0 SEER and 3.0 COP efficiency
ratings with back-up resistance heating not to exceed 5 kW per ton. The maximum allowable
capacity for any installation shall not exceed one ton per 600 square feet of conditioned area. Wall
return air chases must be internally lined with drywall or duct, board sealed at all joints_ and at the floor.
Ceiling' return air plenums must be sealed at ceiling rafters or header plate.
Kitchen and bathroom exhaust fans must be dampered and ducted to exterior. Fireplaces, other than vent
free gas units, must have fire block's and outside combustion air intakes installed at time of initial
inspection
Ridge vents with appropriate numbers and sizes of soffit vents are required. Roof designs providing little_
ridge vent shall install additional turbine, gable or powered vents to provide adequate ventilation.
REBATES FOR HOMES PASSING ALL HEAT GAIN, INSULATION & BLOWER DOOR'INSPECTIONS;
CAPACITY SEER
BTU's RATING
12 13 14 15 16 18
To 41,999 - $400.00 $400.06 $400.00 $400.00 $600.00 $600,00
42,000 to 60,000 $40000 a40000 $60000 $600,00 $600.00 $800,00
N4.14127°E-55.00'
10' P.U.E.
BLOCK I
LOT" 30
40' LANDSCAPE BUFFER
b
SCALE. 1/16• = 1'-W
' I O 5 10 20 I 0
A
T c® m®
==cl==
ir4 z
®�
.RY co 1 Y r- 4
7'-b ..... I ao 0
I W m fl UU cn
_ ; ! . cnn—i
°° I i men®
ci CA m >=
N I w V ®�®
-q
MM
o •-- I x cnr
-0•�
I
rcr(nv:a,
25' SETBACK
N I d'
. L= 23.53'
5' P.U.E. .
�73� �sseh 6.o•p
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: ELKMONT
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 06/10/03
DATE OF PLANS: 06/10/03
PROJECT INFORMATION:
EDELWEISS GARTENS
COLLEGE STATION, TEXAS
LOT 30, BLOCK 1
COMPANY INFORMATION:
OAKWOOD CUSTOM HOMEBUILDERS, L.L.C.
NOTES:
NEW CONSTRUCTION
COMPLIANCE: Passes
Maximum UA = 730
Your Home = 563
22.9% Better Than Code
Ceiling 1: Flat Ceiling or Scissor Truss
Wall 1: Wood Frame, 16" o.c.
Window 1: Metal Frame, Double Pane
Door 1: Glass
Slab 1: Unheated, 0.0' insul.
Air Conditioner 1: Electric Central Air, 12 SEER
Furnace 1: Forced Hot Air, 78 AFUE
Permit Number
Checked By/Date
Gross
Glazing
Area or Cavity
Cont.
or Door
Perimeter R-Value
R-Value
U-Factor
UA
1781 30.0
0.0
62
2313 13.0
0.0
162
282
0.670
189
56
0.140
8
136
0.0
142
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building
plans, specifications, and other calculations submitted with the permit application. The proposed building has
been designed to meet the 2000 IECC requirements in MECcheck Version 3.2 Release lb.
Builder/Designer Date b f o O
MECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 06/10/03
TITLE: ELKMONT
Bldg.
Dept.
Use I
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R 30.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R 13.0 cavity insulation
Comments:
Windows:
1. Window 1: Metal Frame, Double Pane, U-factor: 0.670
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
Doors:
1. Door 1: Glass, U-factor: 0.140
# Panes Frame Type
Comments:
Thermal Break? [ ] Yes [ ] No
Slab -On -Grade Floors:
[ ] 1. Slab l: Unheated, R 0 (uninsulated)
Comments:
Heating and Cooling Equipment:
[ ] 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
[ ] 2. Furnace 1: Forced Hot Air, 78 AFUE or higher
Make and Model Number
[ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
Materials Identification:
[ ] Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
[ ] Materials and equipment must be identified so that compliance can be determined.
[ ] Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on
the building plans or specifications.
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R-5.
Ducts outside the building must be insulated to R 8.0.
Duct Construction:
All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
Cooling ducts with exterior insulation must be covered with a vapor retarder.
Air filters are required in the return air system.
The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the
I levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes.
Insulation Thickness in Inches by Pipe
Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature (F)
Up to 1 "
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low PressureJTemperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5