HomeMy WebLinkAboutRMDL2003-01880 1106 GEORGIA ST BUILDING PERMITPREPARED 9/17/03, 7:06:47 INSPECTION TICKET PAGE 12 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 9/17/03 ---------------------------------------------------•--------------------------------------------- ADDRESS . : 1106 GEORGIA ST SUBDIV: MCCULLOCH (GEORGE) CONTRACTOR : MILLECO CONSTRUCTION PHONE : (979) 764-9465 OWNER : HARNSBERRY, POLLY ANN PHONE : PARCEL : 403500-0007-0310 APPL NUMBER: 03-00001880 RESIDENTIAL, REMODEL & RENOVATION ------------------------------------------------------------------------------------------------ PERMIT: BLDG O1 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B125 01 9/17/03 BI BLDG, FINAL TIME: 17:00 1n 0 () 09/16/2003 02 :14 PM GCARRILLO ----------------------- COMMENTS AND NOTES------------------------------------T- 0-� awn - 09" .n U l L1J 11V 1z t1riKLV11'l CITY STATl'O RWAVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ------------------------------------------------------------------- Application Number . . . . . 03-00001880 Date 6/13/03 Property Address . . . . . . 1106 GEORGIA ST Property ID 403500-0007-0310 R # . . . . . . . R32354 Application description . . . RESIDENTIAL, REMODEL & RENOVATION Subdivision Name . . . . . . MCCULLOCH (GEORGE) Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 21674 Owner ------------------------ Contractor ------------------------ HARNSBERRY, POLLY ANN MILLECO CONSTRUCTION 1106 GEORGIA ST P O BOX 4550 COLLEGE STATION TX 778408201 BRYAN TX 778054550 (979) 764-9465 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . IMPACT/PRORATA FEES PAID NA HEATED AREA 1200.00 INTERIOR WALL TYPE NOA NUMBER OF BATHROOMS .00 NUMBER OF BEDROOMS .00 SEWER TYPE EXISTING ---------------------------------------------------------------------------- SERIAL ZONES 160.00 Permit . . . . . . BUILDING PERMIT Additional desc KE Permit Fee .00 Plan Check Fee .00 Issue Date 6/13/03 Valuation . . . . 21674 Expiration Date 12/10/03 ---------------------------------------------------------------------------- Special Notes and Comments ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS POST PERMIT CARD ON JOB SITE Fee summary ----------------- Charged Paid Credited ------------------------------ Due ---------- Permit Fee Total .00 .00 .00 .00 Plan Check Total .00 .00 .00 .00 Grand Total .00 .00 .00 .00 ------------------- BUILDING DE APPLICANT: APPLICATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEG E-STATIO N.TX.US ADDRESS/LOCATION: LOT BLOCK SUBDIVISION BUSINESS/OWNER NAME; _ plbuj �7A11A1sA Sq$( CONTRACTO ,OMEOWNER:Q \ t It- (.e. 40 CONTRACTO1 ADDRESS: ` '6 ELECTR HVAC: PLUMBER: F . o fin use 0* 2 DATE: -0 /✓� APPLICATION # TEMP POLE # SEC/PH PHONE: ?-18- Sgs ' 1O PHONE: 2 / is, GOOD CENTS (Residential only): s\ '*�\ / CLASS OF WORK ACCESSORY/STORAGE i LOCATION ADDITION, MOVING DEMOLITION (Asbestos SSu ve NEW CONSTRUCTION DUPLEX( a dscape Plan ARJErDEURENOVATION Req) DES RIPTION Q wbAk: �asl/J6-1,71 & ���G� STRUCTURE USE: HOMEOWNER ASSOCIA TEXAS ACCESSIBILITY VALUATION: $ ❑ PUBLIC SEWER SEPTIC/TREATMENT SEWER TAP: WATER TAP: OTHER TAP: TEMP POLE GARAGE TYPE: RE -ROOF (Total/Partial) SHELL ONLY SLAB ONLY SWIMMING POOL )C56'e— 14-ury 9 /2 �t I Os. s(14 L AIARCHITECTUAL OR DESIGN REVIEW EOMMt AL: kN ARD (TAS) PROJECT REGISTRATION# EABPRJ 110 oa TOTAL AREA: /,;LDD HEATED AREA: \an Materials) 4 1\ NUMBER OF BEDROOMS: STEM-, NUMBER OF BATHROOMS: INTERIOR WALL TYPE: SIZE EXTERIOR WALL TYPE: SIZE FOUNDATION TYPE: SIZE ROOF TYPE: SINGLE a ATTACHED SIGNATURE OF APPLICANT: DOUBLE a TRIPLE Q DETACHED El CARPORT Official Use Only Comments: YES or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating SPECIFICATIONS DATA SHEET WORK WRITE-UP CITY OF COLLEGE STATION COMMUNITY DEVELOPMENT OFFICE DATE: 9/3/02 Project Location: 1106 Georgia Owner's Name: Polly Hamsbeny Owner's Telephone: 6Q&08W'2-19' SgOS 144'yv`'`" 2(eo- Z1ZCp Wk- AAA I.AA,►,,A,,, Ait.,,,AAAAAAAAt.%A,,,,,, AAAAAAAAAAAAAAMA ALL WORK ITEMS TO COMPLY WITH THE CITY OF COLLEGE STATION STANDARD SPECIFICATIONS FOR HOUSING REHABILITATION AND ALL CITY CODES. Contractor is to obtain the following and must include the cost of each in the Itemization of Bid Price, the Base Bid, and any Alternative bid: Bonding as rqd. by Bldg Dept. Insurance per contract requirements (see attached Rehab. agreement) Permits / set-up costs Unit will be occupied- during construction. X Building Permit X Electrical Permit X Plumbing Permit X HVAC Permit X Temporary Utilities X X Final Bldg. Inspection Hazardous materials data sheet X List of subs (if contract awarded) nnM Design, material, and installation of the work shall comply with the minimum standards set forth in the STANDARD SPECIFICATIONS MANUAL. Any work not covered in the Standard specifications manual shall comply with the manufacturers product and installation practices and recommendations, or known practices as established by recognized skilled trades industry. THE STANDARD SPECIFICATIONS MANUAL IS A PART OF THE CONTRACT DOCUMENTS BY REFERENCE OR OTHERWISE. In the event the contract specifications conflict with the Standard Specifications Manual, the Contract Specifications shall prevail. S4S shall be defined as " Surfaced Four Sides" meaning nominally cut solid lumber (plywood is not S4S). SECTION 1.0 GENERAL REQUIREMENTS 1.1 Standard specifications Manual Each section of the work write-up will have references to the Standard Specifications Manual. Do not consider other item requirements in the Standard Specifications Manual unless specifically noted. Any confusion or obvious error should be brought to the attention of the City. 1.2 Scope of Work The general Contractor should consider only the work specified in the work write- up and limit repairs to the areas designated. If, during the process of the construction it is determined other work than that work specified is necessary to finish the intended outcome, the contractor shall notify the City and a Change Order will be negotiated and issued to complete all necessary work. DO NOT BID MORE THAN IS REQUESTED EVEN IF YOU BELIEVE ADDITIONAL WORK MAY BE NECESSARY. 1.3 . Workmanship It is expected that the General Contractor will produce the highest quality workmanship possible on every job. However, the City and Owner realize the quality of the product expected shall be weighed against the degree of reconstruction. SPECIAL REQUIREMENTS: All debris from this project must be taken to the Rock Prairie Land Fill (BVSWMA), positively no exceptions. There will be no dumping of this debris on private land at any time for any reason. If such illegal dumping occurs the general contractor will be responsible for the clean up before the retainage payment is made. r SECTION 9.0 MILLWORK AND TRIM 9.3 Countertops Remove existing pre -formed countertops in the kitchen. Install new job built tops covered with laminate. Laminate shall have rolled backs and extend up to the bottom of upper cabinets. (Color to be Owner's choice). Before installation of new countertops prepare cabinets at range location for a freestanding range. Reference: 9.3 SECTION 11.0 EXTERIOR SIDING AND TRIM 11.2 Siding Repair Repair any rotten or damaged exterior siding, soffit, fascia, and trim as needed so that vinyl siding can be attached securely. 11.4 New Sidina Install vinyl siding on entire house that is not covered with brick. Use perforated vinyl material at soffit and gable vents. Wrap fascia, door trim, window trim, and any other trim as needed with vinyl coated metal. Color to be Owner's choice. Before installation of vinyl siding install 1/2" blue board. Seal all seams and penetrations with tape or silicone caulking. Vinyl siding shall be Alcoa (Meadowbrook) or equal. (Color to be Owner's choice) Reference: 11.1.7 SECTION 12.0 PAINTING DO NOT USE LEAD BASE PAINT DEFECTIVE PAINT REMOVAL METHODS 12.2 Safe Treatment Methods Safe treatment methods control the spread of dust and debris. They should be preceded by proper containment practices and followed up with proper clean-up procedures. Examples of safe treatment methods include: a) Wet scraping or wet sanding b) Chemical stripping on- or off -site (except methylene chloride) c) Replacing painted components 12.2 Safe Treatment Methods d) Scraping with an infra -red or coil type heat gun with temperatures below 1,100 degrees Fahrenheit e) Vacuum -sanding using a sander equipped with a High Efficiency Particle Air (HEPA) filter f) Using a HEPA vacuum needle gun g) Contained hydroblasting or high pressure wash with a HEPA vacuum h) Abrasive sanding with a HEPA vacuum i) Covering the painted surface with durable materials (such as wallboard) with joints sealed and caulked. 12.3 Prohibited Methods Prohibited methods can spread lead dust or lead fumes. a) Open flame burning or torching b) Machine sanding or grinding without HEPA exhaust c) Uncontained hydroblasting or high pressure wash d) Abrasive blasting or sandblasting without a HEPA vacuum exhaust e) Heat guns operating above 1,100 degrees Fahrenheit f) Chemical paint strippers containing methylene chloride g) Dry scraping (except around electrical outlets or in conjunction with heat guns). 12.4 Exterior Painting All surfaces to be painted shall be prepped as needed before paint is applied. Paint exterior of house not covered with vinyl siding or brick using paint with no less than a 15- year warranty. Paint a minimum of two coats or until complete coverage is achieved. (Color to be Owner's choice) Reference: 12.2, 12.3, 12.4 SECTION 13.0 PLUMBING 13.1 General Saecifications All plumbing installations shall conform to the City of College Station's Plumbing Code. Owner said that she is having problems with water draining slowly from the kitchen sink. Check the trap and repair as needed. 13.2 Fixtures Install a new washerless faucet at bathroom lavatory. Install new tub/shower valve and trim. Install new waste and overflow trim. Install new water closets in both locations. Install a new 40-gallon electric low -boy water heater. Insulate water lines and make any adjustments needed so that water heater installation will be approved by the City's inspection department. Install vacuum breakers to hose bibs. Reference: 13.1, 13.2, 13.3 SECTION 14.0 HVAC 14.1 HVAC Replace existing A/C and heating system with a 12 SEER system complete with new duct work. All work performed shall be inspected and approved by the city of Collage Station building department. Install dryer vent up through roof. Note: Access may be cut in the gable at back of house to remove and install new water heater and heating unit. Access may be covered with a gable vent. Reference: 14.1 SECTION 15.0 ELECTRICAL RICAL 15.1 General Specifications All electrical installations shall conform with the City of ,College Station electrical code. Add 110 volt smoke detectors with battery back-up as per City code. One in each bedroom and in hallway outside of bedrooms. Smoke detectors must be interconnected. Add GFI protection to kitchen counter receptacles. Check GFI protection for proper operation in bathroom land outside receptacles. Add or replace as needed. Replace existing kitchen light with a new 4' - 4-bulb wrap around florescent light fixture. Re-route wire for motion detector lighting in the attic. Add a separate switch in the hall way for the lights and recess the boxes in the soffit. Install new motion detector light fixtures. Reference: 15.1 SECTION 16.0 MISCELLANEOUS 16.5 Gutters Install seamless gutters to house complete with leaf guards downspouts and splash blocks. Color to be Owner's choice. 16.6 Insulation Install insulation in the entire attic to achieve R-30. Reference: 16.5, 16.6 To view the unit contact the Owner. Any questions in reference to any part of the scope of work please call Joe. Office: 764-3778