HomeMy WebLinkAboutRES2003-01879CITY OF COLLEGE STATION
WORK•-EQUEST PAGE 1
REQ/JOB: WF0420784 )1 PROJECT: REQUEST DATE: 6/24/03
PRINT DATE: 6/24/03
CREW: PRINT TIME: 14:09:59
LOCATION: 5102 BELLERIVE BEND DR SCHEDULE
START:DATES 6/24/03
77840 COMPLETION: 6/24/03
GEN. LOC: COLLEGE STATION LOC ID 187316
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: CGM HOMEBUILDERS (764-6701) ORIGIN: CUSTOMER -WALK IN
USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE
4" SEWER AND 3/4" WATER
4" SEWER AND 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
PREPARED 4/29/04, 12:01:38 INSPECTION TICKET PAGE 1
City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/29/04
------------------------------------------------------------------------------------------------
ADDRESS . : 5102 BELLERIVE BEND DR SUBDIV: PEBBLE CREEK
CONTRACTOR C G M HOMEBUILDERS PHONE : (979) 764-6701
OWNER CGM HOME BUILDERS CORP PHONE :
-PARCEL 497900-0043-0020
APPL NUMBER: 03-00001879 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT: BLDG 00 BUILDING PERMIT
REQUESTED INSP DESCRIPTION
TYP/SQ COMPLETED RESULT RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01 8/05/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00
8/06/03 AP 08/04/2003 04:37 PM MALFORD
TUESDAY PM
SLAB GROUND BACK WALL TO LEFT OF PORCH.
B115 01 9/18/03 TB BLDG, FRAMING TIME: 17:00
9/18/03 AP 09/17/2003 10:58 AM MALFORD
TOMORROW MORNING 9/18/03
09/18/2003 11:31 AM MALFORD
take flooring in upstairs all the way to the edge,
fireblock triangular area to righ tof master tub and right
side of fireplace �
B130 01 9/25/03 TB BLDG, INSULATION TIME: 17:00
9/25/03 AP 09/23/2003 04:05 PM GCARRILLO
B125 01 4/29/04 BI BLDG, FINAL TIME: 17:00
' �� 04/29/2004 08:08 AM MALFORD
-------------------------------
CITY OF COLLEGE STATION
WORK REQUEST
REQ/JOB: WF0436025 / 001 PROJECT:
CREW:
PAGE 1
REQUEST DATE: .7/29/03
PRINT DATE: 7/29/03
PRINT TIME: 13:23:35
LOCATION: 5102 BELLERIVE BEND DR SCHEDULE DATES
77840 COMPLETION: 7/29703
GEN. LOC: COLLEGE STATION LOC ID: 187316
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: CGM HOME BUILDERS ORIGIN: CUSTOMER -WALK IN
USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
BUILDING PERMIT �+
CITY OF C,,LEGE • S'ITATIO
-. _.
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
----------------------------------------------------------------------------
Application Number . .
. . . 03-00001879 Date 6/24/03
Property Address . . .
. . . 5102 BELLERIVE BEND DR
Property ID . . . . . .
. . . 497900-0043-0020
R # . . . . . . . . . .
. . . R105252
Application description
. . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . . .
. . . PEBBLE CREEK
Property Use . . . . .
. . . RESIDENTIAL
Property Zoning . . . .
. . . SINGLE FAMILY RESIDENTIAL
Application valuation .
. . . 230000
Owner
Contractor
------------------------
CGM HOME BUILDERS CORP
------------------------
C G M HOMEBUILDERS
PO BOX 10588
BILLY CHENAULT
COLLEGE STATION TX
778420588 P O BOX 10588
COLLEGE STATION TX 77842
(979) 764-6701
--------------------------
Structure Information -------------------------
Construction Type . . .
. . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . . .
. . RESIDENTIAL-SFR/DUPLEX
Other struct info . . .
. . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
TYPE OF GARAGE (ATT/DET) ATT
HEATED AREA 3367.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 4.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 252.00
----------------------------------------------------------------------------
Permit . . . . . . BUILDING
PERMIT
Additional desc . . LL
Permit Fee . . . .
850.00 Plan Check Fee .00
Issue Date . . . .
6/24/03 Valuation . . . . 230000
Expiration Date . .
12/21/03
Qty Unit Charge
Per Extension
BASE FEE 460.00
130.00 3.0000 THOU BLDG, VAL 100001-500000 390.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE
PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
------------------
BUILDING P
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATIO:
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00001879
Page 2
Date 6/24/03
Special Notes and Comments
PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22"
X 3011) PER SECTION R807, 2000 IRC
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
BUILDING D
APPLICANT:
BUILDING PERMIT
° CITY OF COLLEGE STATIO
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number . . . . .
03-00001879
Date
6/24/03
----------------------------------------------------------------------------
Special Notes and Comments
WINDOWS ADJACENT TO TUBS SHALL
BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN
24" OF DOORS
AN APPROVED DEVICE FOR THERMAL
EXPANSION CONTROL
SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER
HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4" CITY
INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged
Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 850.00
850.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1600.00
1600.00
.00
.00
------------------
BUILDING L
APPLICANT:
LICATION FOR BUILDING PER,
CITY OF COLLEGE STATION
1101 TEXAS AVENUE
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764.3496 FAX
WWW.CI.00LLEGE-6TATI0N.TX.US
ADDRESS/LOCAJION: SIDa 'Rkcae-a4ve r� 1''
LOT �- BLOCK 4 3 SUBDIVISION Pe.)creek_
BUSINESS/OWNER NAME: L° Q, Ph Ably,. 'gu�/�e7Ls� 3:Ac. PHONE: ! (p4-0o)
CONTRACTOR/HOMEOWNER:
CONTRACTOR ADDRESS: % O
ELECTRICIAN: _ 6 4ex Fl e .4-?, ; c,
HVAC: A ; r C aikce to fS
ACCESSORY/STORAGE
ADDITION
DEMOLITION (Asbestos Survey)
DUPLEX (Landscape Plans Req)
DESCRIPTION OF WORK: N e-u
STRUCTURE USE:
Aw ante use 0*
DATE: ,�
APPUC C OMN A
TEMP POLE 8
PHONE: o;�-ZO - gfgj*
PLUMBER:'_ CaKAr-1 I CX --� � g
GOOD CENTS (ResidenUal only):
CLASS OF WORK
LOCATION
MOVING
NEW CONSTRUCTION
REMODEURENOVATION
RE -ROOF (Total/Partial)
SHELL ONLY
SLAB ONLY
SWIMMING POOL
HOMEOWNER ASSOCIATIOWARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (fAS) PROJECT REGISTRATION# EABPRJ
VALUATION: $ 23 D,,0 0 D TOTAL AREA: S HEATED AREA
(Cost of Labor and Materials)
® PUBLIC SEWER
SEPTICITREATMENT SYSTEM
SEWER TAP:
SIZE
WATER TAP: 3/
S12i
®'OTHER TAP:
SIZE
TEMP POLE
GARAGE TYPE: SINGLE a
ATTACHED
NUMBER OF BEDROOMS:
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
EXTERIOR WALL TYPE:
FOUNDATION TYPE:
4
4
S LaiL.a a-ti4 Cro.��t.
ROOF TYPE:
DOUBLE Q TRIPLE
DETACHED a CARPORT a
SIGNATURE OF APPLICANT:
Otirdal 6se Onlye-ZemMants:
'13�' NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls -
Insulation R value of exterior walls 113
Insulation R value of ceiling 1 (flat areas) 130
Insulation R value of ceiling 2 (vaulted areas/no attic) 1q
Glazing SHGC "-3 (P
Glazing U-Factor . Ce o
R value of ductwork (o
A/C SEER rating 12
i
00,091
3NI3 9NIQ-lIna ,S'/-
z
W
�� W w w
H w L
LiJ �
CDI W
H
CD J I W I
�I a
R
of
O
O
O
O
r
pa
TRUE
�Lu
Q�
hi
c'. : d
CGM Home Builders Inc
PO Box 10588 5102 Bellerive Bend Voice: 979.764.6701
College Station, Tx 77842 Fax #: 979.764.6721
Foundations
Excavation:
6-Mil Poly
Steel:
Slab-#3 Rebars at 12" O.C.E.W
Ext. Beams = 3 #6 Rebar T&B
Int. Beams= 3 #6 Rebar T&B
Concrete
3000 Psi
Stirrups:
#3 Rebar
Sand Fill:
Min. 6"
Beam Size:
Ext 12"w X 36" depth
Int 12:w X 30" or 36" depth
Concrete Drive:
3000 Psi with #3 Rebar or 6x6x #6 WWM
Walks:
3000 Psi with #3 Rebar or 6x6x #6 WWM
Termite Production:
Per Codes - Foundation Pre -treat Commercially
The Contractor reserves the right to make the height of the slab a minimum of (field decision)
from top of the slab to the top of the normal grade level at its highest point. The size of the beam
and the steel will remain the same as shown on the foundation plan.
Framing
Exterior Walls:
Bottom Plates Treated on Concrete, All Others
#2YP, SPF or equal Celotex, Plywood or Wafer Board
to be applied for Comer Bracing with #15 Felt for
Waterproofing at bottom
Partition Framing:
2x4 16" Centers #2YP SPF or equal
Ceiling Joists:
2x6 #2YP SPF or equal
Rafters:
2x6 & 2x8 #2YP SPF or equal
Form Materials:
To be reused in structure where possible
Decking:
7/16" OSB Plywood
Roofing:
Composition (30 year) w/ 151b felt
Roof Ventilators:
Soffit, Ridge & Gable Vents
Soffit:
Primed Masonite
Fascia:
Primed Hardiplank or Masonite
Roof Edging Strip:
Metal
Nails:
Per City of College Station Building Codes
Brick:
Builder's Selection: lBrick per selection
Hardiplank siding dormers
Page 1
CGM Home Builders Inc
PO Box 10588 5102 Bellerive Bend Voice: 979.764.6701
College Station, Tx 77842 Fax #: 979.764.6721
Doors:
Exterior Entry:
Per owners selection per Allowance
Rear Doors:
Metal, Insulated, weather strips/threshold, 6 Panel
IMasonite
Interior:
Hollow Core 6 panel
Windows:
Single Hung Divided Lite: Aluminum insulated Low E Alenco
Interior Trim:
Door Case:
Finger Joint Wedge or'H'
Base:
Finger Joint Wedge or'H'
Door Jambs:
SPF Paintgrade
Window:
SPF Paintgrade
Closets:
Rod & Shelf
Shelving:
Paint Grade Materials
Cabinets:
Kitchen:
Pre Fabricated Alder (Stained Grade) with raised panel door
Bath:
Pre Fabricated (Paint Grade) with flat panel door
Utility Room:
Same
Finished Floors:
Entry:
Tile or Wood per allowance
Living Room:
Tile per Allowance
Dining Room:
Tile per Allowance
Hall:
Carpet per allowance
Kitchen:
Tile per Allowance
Utility Room:
]Tile
Tile per Allowance
Bath #1 Master
per Allowance
Bath #2, #3, #4
Tile per Allowance
Bedrooms:
Carpet per allowance
Closets:
Carpet per allowance
Page 2
CGM Home Builders Inc
PO Box 10588 5102 Bellerive Bend Voice: 979.764.6701
College Station, Tx 77842 Fax #: 979.764.6721
Finished Walls:
Entry
All walls to be drywall, taped, floated, textured and painted
Living:
Same
Dining:
Same
Hall:
Same
Kitchen:
Same
Utility:
Same
Storage:
Same
Bath #1 Master
Same
Bath #2 Powder
Same
Bath #3, #4
Same
Bedroom #1
Same
Bedroom #2, #3, #4
Same
Ceilings:
Same
Other:Garage --iSame
Painting
Exterior:
Trim Only
Interior:
1 Prime Coat & 1 Finish Coat (Latex Flat)
Doors & Trim:
1 Prime Coat & 1 Finish Coat (Latex Flat)
Formica,Ceramic Tile, Marble:
Kitchen:
Granite per allowance
Bath Vanities:
Formica per allowance
Master Bath:
Granite per allowance
Bath #2 Powder
Granite per allowance
Bath #3, #4
ISynthetic Marble Bowls
Electrical:
General:
All electrical to in Accordance with City of College Station
Electrical Codes and Per Plans
Service:
Same
Supply:
Same
Dryer Outlet:
One per side
Door Chimes:
One per side
Telephone Outlet:
Each Bedroom & Living Room per allowance
Cable TV
Each Bedroom & Living Room per allowance
Security:
ISecurity System included or per allowance
Sound:
ISound System included or per allowance
Page 3
CGM Home Builders Inc
PO Box 10588 5102 Bellerive Bend Voice: 979.764.6701
College Station, Tx 77842 Fax #: 979.764.6721
Plumbing
Water:
Inside Building=Copper, PVC Yard Lines
Drain:
PVC
Kitchen:
SS Sink per allowance
Master Tub
Whirlpool per allowance
Toilets:
Elongated per allowance
Utility:
Washing Machine Box & ice machine box (1) utility sink
Water Heaters
50 gal Nat'l Gas in attic with pan
Master Bath:
Per allowance
Bath #2 Powder
Per allowance
Bath #3, #4
Per allowance
Vanities:
One piece - Synthetic Marble bowls or equal
Faucets: Bath #2, #3, & #4
Chrome Delta or equal
Faucets: Master
Satin Nickel Delta select or Equal
Mechanical:
Size of Unit: Gas Heat / Elect 12 SEER
Mechanical Contractors (sized per Mechanical
Contractors design)
Insulation:
Walls: R-13 Batt with Polyseal
Attic: IR-30 Loose fill blown -in
Page 4
CGM Home Builders Inc
Po Box 10588 5102 Bellerive Bend Voice: 979.764.6701
College Station, Tx 77842 Fax M 979.764.6721
Landscape:
Irrigation:
Single, 4-zone, front & back
Sod:
Full, front & back yard
Plants:
Tree & Shrub Package per City Specs & allowance
Fence:
Cedar, picket w/ 2 gates
Appliances:
Dishwasher:
Kitchen Aid or equal per allowance
Range Top:
Gas 36" or equal per allowance
Vent Hood:
Per allowance
Disposal:
ISEA Badger 5 or equal
Refrigerator:
Not Included
Washing Machine:
Not Included
Dryer
Not Included
Oven
Per allowance
Hardware:
Bedroom Doors ,Hall, Bath
Per Allowance
All other doors
Per Allowance
Exterior Door:
Per Allowance
Baths:
Per Allowance
Allowances:
Carpert
1648
Tile
12154
Wood Floors
3120
Electrical Fixtures:
4000
Appliances
4000
Wallpaper
1500
Landscaping
2000
I rragation
2400
Hardware:
2000
Security
500
Sound: Home Theater ETC
1500
Page 5
CGM Home Buildens Inc
Po Box 10588 5102 Belierive Bend Voice: 979.764.6701
College Station, Tx 77842 Fax M 979.764.6721
Note: Inspections by the City of College College Station Building Officials are to the guide of acceptable
construction practices and/or procedures.
Date:
Contractor:
Owner(s)
Page 6