Loading...
HomeMy WebLinkAboutRES2003-01879CITY OF COLLEGE STATION WORK•-EQUEST PAGE 1 REQ/JOB: WF0420784 )1 PROJECT: REQUEST DATE: 6/24/03 PRINT DATE: 6/24/03 CREW: PRINT TIME: 14:09:59 LOCATION: 5102 BELLERIVE BEND DR SCHEDULE START:DATES 6/24/03 77840 COMPLETION: 6/24/03 GEN. LOC: COLLEGE STATION LOC ID 187316 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: CGM HOMEBUILDERS (764-6701) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE PREPARED 4/29/04, 12:01:38 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 4/29/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 5102 BELLERIVE BEND DR SUBDIV: PEBBLE CREEK CONTRACTOR C G M HOMEBUILDERS PHONE : (979) 764-6701 OWNER CGM HOME BUILDERS CORP PHONE : -PARCEL 497900-0043-0020 APPL NUMBER: 03-00001879 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 8/05/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 8/06/03 AP 08/04/2003 04:37 PM MALFORD TUESDAY PM SLAB GROUND BACK WALL TO LEFT OF PORCH. B115 01 9/18/03 TB BLDG, FRAMING TIME: 17:00 9/18/03 AP 09/17/2003 10:58 AM MALFORD TOMORROW MORNING 9/18/03 09/18/2003 11:31 AM MALFORD take flooring in upstairs all the way to the edge, fireblock triangular area to righ tof master tub and right side of fireplace � B130 01 9/25/03 TB BLDG, INSULATION TIME: 17:00 9/25/03 AP 09/23/2003 04:05 PM GCARRILLO B125 01 4/29/04 BI BLDG, FINAL TIME: 17:00 ' �� 04/29/2004 08:08 AM MALFORD ------------------------------- CITY OF COLLEGE STATION WORK REQUEST REQ/JOB: WF0436025 / 001 PROJECT: CREW: PAGE 1 REQUEST DATE: .7/29/03 PRINT DATE: 7/29/03 PRINT TIME: 13:23:35 LOCATION: 5102 BELLERIVE BEND DR SCHEDULE DATES 77840 COMPLETION: 7/29703 GEN. LOC: COLLEGE STATION LOC ID: 187316 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: CGM HOME BUILDERS ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE BUILDING PERMIT �+ CITY OF C,,LEGE • S'ITATIO -. _. COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001879 Date 6/24/03 Property Address . . . . . . 5102 BELLERIVE BEND DR Property ID . . . . . . . . . 497900-0043-0020 R # . . . . . . . . . . . . . R105252 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . PEBBLE CREEK Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 230000 Owner Contractor ------------------------ CGM HOME BUILDERS CORP ------------------------ C G M HOMEBUILDERS PO BOX 10588 BILLY CHENAULT COLLEGE STATION TX 778420588 P O BOX 10588 COLLEGE STATION TX 77842 (979) 764-6701 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 3.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 3367.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 4.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 252.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . LL Permit Fee . . . . 850.00 Plan Check Fee .00 Issue Date . . . . 6/24/03 Valuation . . . . 230000 Expiration Date . . 12/21/03 Qty Unit Charge Per Extension BASE FEE 460.00 130.00 3.0000 THOU BLDG, VAL 100001-500000 390.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) ------------------ BUILDING P APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIO: 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001879 Page 2 Date 6/24/03 Special Notes and Comments PROVIDE ATTIC ACCESS OPENING (MINIMUM ROUGH -FRAMED SIZE 22" X 3011) PER SECTION R807, 2000 IRC PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. BUILDING D APPLICANT: BUILDING PERMIT ° CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00001879 Date 6/24/03 ---------------------------------------------------------------------------- Special Notes and Comments WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 850.00 850.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1600.00 1600.00 .00 .00 ------------------ BUILDING L APPLICANT: LICATION FOR BUILDING PER, CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764.3496 FAX WWW.CI.00LLEGE-6TATI0N.TX.US ADDRESS/LOCAJION: SIDa 'Rkcae-a4ve r� 1'' LOT �- BLOCK 4 3 SUBDIVISION Pe.)creek_ BUSINESS/OWNER NAME: L° Q, Ph Ably,. 'gu�/�e7Ls� 3:Ac. PHONE: ! (p4-0o) CONTRACTOR/HOMEOWNER: CONTRACTOR ADDRESS: % O ELECTRICIAN: _ 6 4ex Fl e .4-?, ; c, HVAC: A ; r C aikce to fS ACCESSORY/STORAGE ADDITION DEMOLITION (Asbestos Survey) DUPLEX (Landscape Plans Req) DESCRIPTION OF WORK: N e-u STRUCTURE USE: Aw ante use 0* DATE: ,� APPUC C OMN A TEMP POLE 8 PHONE: o;�-ZO - gfgj* PLUMBER:'_ CaKAr-1 I CX --� � g GOOD CENTS (ResidenUal only): CLASS OF WORK LOCATION MOVING NEW CONSTRUCTION REMODEURENOVATION RE -ROOF (Total/Partial) SHELL ONLY SLAB ONLY SWIMMING POOL HOMEOWNER ASSOCIATIOWARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (fAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 23 D,,0 0 D TOTAL AREA: S HEATED AREA (Cost of Labor and Materials) ® PUBLIC SEWER SEPTICITREATMENT SYSTEM SEWER TAP: SIZE WATER TAP: 3/ S12i ®'OTHER TAP: SIZE TEMP POLE GARAGE TYPE: SINGLE a ATTACHED NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: 4 4 S LaiL.a a-ti4 Cro.��t. ROOF TYPE: DOUBLE Q TRIPLE DETACHED a CARPORT a SIGNATURE OF APPLICANT: Otirdal 6se Onlye-ZemMants: '13�' NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls - Insulation R value of exterior walls 113 Insulation R value of ceiling 1 (flat areas) 130 Insulation R value of ceiling 2 (vaulted areas/no attic) 1q Glazing SHGC "-3 (P Glazing U-Factor . Ce o R value of ductwork (o A/C SEER rating 12 i 00,091 3NI3 9NIQ-lIna ,S'/- z W �� W w w H w L LiJ � CDI W H CD J I W I �I a R of O O O O r pa TRUE �Lu Q� hi c'. : d CGM Home Builders Inc PO Box 10588 5102 Bellerive Bend Voice: 979.764.6701 College Station, Tx 77842 Fax #: 979.764.6721 Foundations Excavation: 6-Mil Poly Steel: Slab-#3 Rebars at 12" O.C.E.W Ext. Beams = 3 #6 Rebar T&B Int. Beams= 3 #6 Rebar T&B Concrete 3000 Psi Stirrups: #3 Rebar Sand Fill: Min. 6" Beam Size: Ext 12"w X 36" depth Int 12:w X 30" or 36" depth Concrete Drive: 3000 Psi with #3 Rebar or 6x6x #6 WWM Walks: 3000 Psi with #3 Rebar or 6x6x #6 WWM Termite Production: Per Codes - Foundation Pre -treat Commercially The Contractor reserves the right to make the height of the slab a minimum of (field decision) from top of the slab to the top of the normal grade level at its highest point. The size of the beam and the steel will remain the same as shown on the foundation plan. Framing Exterior Walls: Bottom Plates Treated on Concrete, All Others #2YP, SPF or equal Celotex, Plywood or Wafer Board to be applied for Comer Bracing with #15 Felt for Waterproofing at bottom Partition Framing: 2x4 16" Centers #2YP SPF or equal Ceiling Joists: 2x6 #2YP SPF or equal Rafters: 2x6 & 2x8 #2YP SPF or equal Form Materials: To be reused in structure where possible Decking: 7/16" OSB Plywood Roofing: Composition (30 year) w/ 151b felt Roof Ventilators: Soffit, Ridge & Gable Vents Soffit: Primed Masonite Fascia: Primed Hardiplank or Masonite Roof Edging Strip: Metal Nails: Per City of College Station Building Codes Brick: Builder's Selection: lBrick per selection Hardiplank siding dormers Page 1 CGM Home Builders Inc PO Box 10588 5102 Bellerive Bend Voice: 979.764.6701 College Station, Tx 77842 Fax #: 979.764.6721 Doors: Exterior Entry: Per owners selection per Allowance Rear Doors: Metal, Insulated, weather strips/threshold, 6 Panel IMasonite Interior: Hollow Core 6 panel Windows: Single Hung Divided Lite: Aluminum insulated Low E Alenco Interior Trim: Door Case: Finger Joint Wedge or'H' Base: Finger Joint Wedge or'H' Door Jambs: SPF Paintgrade Window: SPF Paintgrade Closets: Rod & Shelf Shelving: Paint Grade Materials Cabinets: Kitchen: Pre Fabricated Alder (Stained Grade) with raised panel door Bath: Pre Fabricated (Paint Grade) with flat panel door Utility Room: Same Finished Floors: Entry: Tile or Wood per allowance Living Room: Tile per Allowance Dining Room: Tile per Allowance Hall: Carpet per allowance Kitchen: Tile per Allowance Utility Room: ]Tile Tile per Allowance Bath #1 Master per Allowance Bath #2, #3, #4 Tile per Allowance Bedrooms: Carpet per allowance Closets: Carpet per allowance Page 2 CGM Home Builders Inc PO Box 10588 5102 Bellerive Bend Voice: 979.764.6701 College Station, Tx 77842 Fax #: 979.764.6721 Finished Walls: Entry All walls to be drywall, taped, floated, textured and painted Living: Same Dining: Same Hall: Same Kitchen: Same Utility: Same Storage: Same Bath #1 Master Same Bath #2 Powder Same Bath #3, #4 Same Bedroom #1 Same Bedroom #2, #3, #4 Same Ceilings: Same Other:Garage --iSame Painting Exterior: Trim Only Interior: 1 Prime Coat & 1 Finish Coat (Latex Flat) Doors & Trim: 1 Prime Coat & 1 Finish Coat (Latex Flat) Formica,Ceramic Tile, Marble: Kitchen: Granite per allowance Bath Vanities: Formica per allowance Master Bath: Granite per allowance Bath #2 Powder Granite per allowance Bath #3, #4 ISynthetic Marble Bowls Electrical: General: All electrical to in Accordance with City of College Station Electrical Codes and Per Plans Service: Same Supply: Same Dryer Outlet: One per side Door Chimes: One per side Telephone Outlet: Each Bedroom & Living Room per allowance Cable TV Each Bedroom & Living Room per allowance Security: ISecurity System included or per allowance Sound: ISound System included or per allowance Page 3 CGM Home Builders Inc PO Box 10588 5102 Bellerive Bend Voice: 979.764.6701 College Station, Tx 77842 Fax #: 979.764.6721 Plumbing Water: Inside Building=Copper, PVC Yard Lines Drain: PVC Kitchen: SS Sink per allowance Master Tub Whirlpool per allowance Toilets: Elongated per allowance Utility: Washing Machine Box & ice machine box (1) utility sink Water Heaters 50 gal Nat'l Gas in attic with pan Master Bath: Per allowance Bath #2 Powder Per allowance Bath #3, #4 Per allowance Vanities: One piece - Synthetic Marble bowls or equal Faucets: Bath #2, #3, & #4 Chrome Delta or equal Faucets: Master Satin Nickel Delta select or Equal Mechanical: Size of Unit: Gas Heat / Elect 12 SEER Mechanical Contractors (sized per Mechanical Contractors design) Insulation: Walls: R-13 Batt with Polyseal Attic: IR-30 Loose fill blown -in Page 4 CGM Home Builders Inc Po Box 10588 5102 Bellerive Bend Voice: 979.764.6701 College Station, Tx 77842 Fax M 979.764.6721 Landscape: Irrigation: Single, 4-zone, front & back Sod: Full, front & back yard Plants: Tree & Shrub Package per City Specs & allowance Fence: Cedar, picket w/ 2 gates Appliances: Dishwasher: Kitchen Aid or equal per allowance Range Top: Gas 36" or equal per allowance Vent Hood: Per allowance Disposal: ISEA Badger 5 or equal Refrigerator: Not Included Washing Machine: Not Included Dryer Not Included Oven Per allowance Hardware: Bedroom Doors ,Hall, Bath Per Allowance All other doors Per Allowance Exterior Door: Per Allowance Baths: Per Allowance Allowances: Carpert 1648 Tile 12154 Wood Floors 3120 Electrical Fixtures: 4000 Appliances 4000 Wallpaper 1500 Landscaping 2000 I rragation 2400 Hardware: 2000 Security 500 Sound: Home Theater ETC 1500 Page 5 CGM Home Buildens Inc Po Box 10588 5102 Belierive Bend Voice: 979.764.6701 College Station, Tx 77842 Fax M 979.764.6721 Note: Inspections by the City of College College Station Building Officials are to the guide of acceptable construction practices and/or procedures. Date: Contractor: Owner(s) Page 6