HomeMy WebLinkAboutRES2003-01865PREPARED 10/28/03, 12:10:59
INSPECTION
TICKET PAGE 3
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR:
BUILDING INSPECTOR DATE 10/28/03
ADDRESS
. : 122 KARTEN LN
SUBDIV: EDELWEISS GARTENS PH 2
CONTRACTOR : T D T HOMES
PHONE : (979) 690-7117
OWNER
: EDELWEISS GARTEN VENTURE
PHONE :
PARCEL
: 244030-0205-0010
APPL NUMBER: 03-00001865 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
6/17/03 CH
BLDG, FOUNDATION -SLAB TIME: 17:00
6/18/03 AP
06/17/2003 09:13
AM SSTANLEY
'
Early afternoon.
B 01
7/11/03 OC
BLDG, FRAMING TIME: 17:00
7/11/03 AP
07/11/2003 08:52
AM KELMENDORF
B125 01
10/2a,/03 BI
'AP
BLDG, FINAL TIME:
17:00
(o aglo3 OC►
10/28/2003 10:12
AM GCARRILLO
-------------------------------------- COMMENTS AND NOTES--------------------------------------
Linda Long -''I P-S61 it ion request inspection result, 122 Karten, #03-1865 _ _ - Page 9
From: Brian Henry
To: Long, Linda
Date: 7/14/03 10:15AM
Subject: Insulation request inspection result, 122 Karten, #03-1865
Print for file
Inspected insulation, 122 Karten, #03-1865, Benchmark Homes, 7-14-03
Inspection result: Inspected OK for Good Cents.
Notes:
Connect the fireplace outside air duct.
CC: Stanley, Susan
CITY OF COLLEGE STATION
0 WOR •REQUEST
REQ/JOB: WF0417108 001
CREW:
LOCATION: 122 KARTEN LN
PAGE 1
PROJECT: REQUEST DPRINT ATE:
6//12%03
PRINT TIME: 9:19:47
SCHEDULE DATES
START: 61203
77845 COMPLETION: 6712/03
GEN. LOC: COLLEGE STATION LOC ID: 197872
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: TDT HOMES (690-7117) ORIGIN: CUSTOMER -WALK IN
USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE
TEMP POLE PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
aRr
ae
-CITY �T SST IO
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE:
----------------------------------------------------------------------------
(979)764-3570 FAX: (979)764-3496
Application Number
. . . . . 03-00001865
Date 6/10/03
Property Address
. . . . . . 122 KARTEN LN
Property ID
. . 244030-0205-0010
R # . . . . . . .
. . . . . . R114637
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name
. . . . . . EDELWEISS GARTENS PH 2
Property Use . .
. . . . . . RESIDENTIAL
Property Zoning .
. . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 120000
Owner
Contractor
------------------------
EDELWEISS GARTEN
------------------------
VENTURE T D T HOMES
311 CECILIA LOOP
GLENN THOMAS
COLLEGE STATION
TX 778456310 1110 12TH MAN
COLLEGE STATION
TX 77845
(979) 690-7117
--------------------------
Structure Information -------------------------
Construction Type
. . . . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type .
. . . . . RESIDENTIAL-SFR/DUPLEX
Other struct info
. . . . . EXTERIOR WALL TYPE
BRICK
IMPACT/PRORATA FEES PAID
NA
FOUNDATION TYPE
SLAB
NUMBER OF GARAGE BAYS
2.00
TYPE OF GARAGE (ATT/DET)
ATT
HEATED AREA
1426.00
INTERIOR WALL TYPE
SHEETROCK
NUMBER OF BATHROOMS
2.00
NUMBER OF BEDROOMS
3.00
SEWER TYPE
PUBLIC
SERIAL ZONES
247.00
----------------------------------------------------------------------------
Permit . . . . .
. BUILDING PERMIT
Additional desc .
. SS
Permit Fee . . .
. 520.00 Plan Check Fee
.00
Issue Date . . .
. 6/10/03 Valuation . .
. . 120000
Expiration Date .
. 12/07/03
Qty Unit Charge Per
Extension
BASE FEE
460.00
20.00 3.0000
THOU BLDG, VAL 100001-500000
60.00
----------------------------------------------------------------------------
Special Notes and
Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
------------------
BUILDING P
APPLICANT:
Z�� - - - - - - - - - - - - - - - - - - - - - -
BUILDING PERMIT
CITY OF COLLEGE STATIC
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
Application Number . . . . . 03-00001865
Page 2
Date 6/10/03
Special Notes and Comments
PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
POST PERMIT CARD ON JOB SITE
RECESSED LIGHTING INSTALLED IN THE BUILDING.ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
VEGETATION AND FOREIGN MATERIAL.
WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS
TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS
AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
BUILDING DE
APPLICANT:
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATIC
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . .
03-00001866 Date
6/10/03
Property Address . . . . . .
122 KARTEN LN
Property ID . . . . . . . . .
244030-0205-0010
Application description . . .
TEMP POLE
Subdivision Name . . . . . .
EDELWEISS GARTENS PH 2
Property Use . . . . . . . .
RESIDENTIAL
Property Zoning . . . . . . .
SINGLE FAMILY RESIDENTIAL
Application valuation . . . .
0
Owner
Contractor
------------------------
EDELWEISS GARTEN VENTURE
------------------------
T D T HOMES
311 CECILIA LOOP
GLENN THOMAS
COLLEGE STATION TX 778456310
1110 12TH MAN
COLLEGE STATION
TX 77845
(979) 690-7117
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE
PERMIT
Additional desc . . SS
Permit Fee . . . . 20.00
Issue Date . . . . 6/10/03
Valuation . . . .
0
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
TEMP ELECT POLE CONNECT
45.00
Fee summary Charged
Paid Credited
------------------------------
Due
---------------------------
Permit Fee Total 20.00
20.00 .00
.00
Other Fee Total 45.00
45.00 .00
.00
Grand Total 65.00
65.00 .00
.00
-------------------
BUILDING DE
APPLICANT:
BUILDING PERMIT
CITY OF COLLEGE STATI(
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page 3
Application Number . . . . . 03-00001865 Date 6/10/03
----------------------------------------------------------------------------
Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00
WATER TAP 3/4" CITY INSTL 400.00
Fee summary Charged
Permit Fee Total 520.00
Plan Check Total .00
Other Fee Total 750.00
Grand Total 1270.00
-------------------
BUILDING DE
APPLICANT:
Paid Credited Due
------------------------------
520.00 .00 .00
.00 .00 .00
750.00 .00 .00
1270.00 .00 .00
CITY OF COLLEGE STATION
WOR: EQUEST
REQ/JOB: WF0416560 / 001 PROJECT:
CREW:
LOCATION: 122 KARTEN LN
77845
PAGE 1
REQUEST DATE: 6/10/03
PRINT DATE: 6/10/03
PRINT TIME: 16:32:59
SCHEDULE DATES
START: 6/1003
COMPLETION: 6710/03
GEN. LOC: COLLEGE STATION LOC ID: 197872
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL
REQUESTOR: T D T HOMES ORIGIN: CUSTOMER -WALK IN
USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE
4" SEWER 3/4" WATER
-------------------------------------------------------------------------------
-------------------------------------------------------------------------------
4" SEWER 3/4" WATER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
Q*
ILICATION FOR BUILDING PEI T
CITY OF COLLEGE STATION
1101 TEXAS AVENUE F ,
COLLEGE STATION, TX 77840
(979) 764-3570 (979) 764-3496 FAX
W WW.CI.COLLEGE-STATION.TX.US
ADDRESS/LOCATION: [At, - ,j?e r 4ah
DATE (0-10
APPLICAn0N'1 1
TEMP POLE x 0 �— I
LOT BLOCK SUBDIVISION R aa? � S �>-�-� 8` ha To
BUSINESS/OWNER NAME: %- 7D .T 1A PHONE: Cj o — -7 11 %
�
CONTRACTOR/HOMEOWNER: PHONE: 14 1 2- -.24 IS
CONTRACTOR ADDRESS: I) I ® 15-" 1 R if 6 ( fee_
ELECTRICIAN: ) C- tl e' PLUMBER: Nvn b , r
HVAC: &rWA of -I I GOOD CENTS (Residential ordy):
C SS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MOVING SHELL ONLY
DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL
DESCRIPTION OF WORK: -"-? i a-i!� lz I, A,C j\ c-uz
STRUCTURE USE: O� Lc 4 `rtz I �I
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:' C
TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ rC
VALUATION: $ • t ' i W, tt C' TOTAL AREA: f4*— HEATED AREA: H
(Cost of Labor and Materials
lij'UBLIC SEWER NUMBER OF BEDROOMS: 3
SEPTIC/TREATMENT SYSTEM
E-EWER TAP:q It
SME
0' I�VATER TAP:
Sim
OTHER TAP:
SIZE
NUMBER OF BATHROOMS:
INTERIOR WALL TYPE:
ExTERiOR WALL TYPE:
FOUNDATION TYPE:
—*L/z
TEMP POLE ROOF TYPE:
GARAGE TYPE: SINGLE Q DOUBLE TRIPLE a
ATTACHED Q DETACHED a CARPORT a
SIGNATURE OF APPLICANT:
Offidal Use Only ants:
C., � E or NO
Plans Examiner Zoning Official
Energy Code Compliance Information
% Glazing of exterior walls
Insulation R value of exterior walls
Insulation R value of ceiling 1 (flat areas)
Insulation R value of ceiling 2 (vaulted areas/no attic)
Glazing SHGC
Glazing U-Factor
R value of ductwork
A/C SEER rating
eye
45
�P
r
v'r
a
P4%P IVIts-
,J
Qaf
MECcheck Compliance Report
2000 IECC
MECcheck$oft-*are Version 3.4 Release la
Data filename: C:\Program Files\Check\MECcheck\MecCheck bcs\161TDT.cck
TITLE: TDT#161
CITY: College Station
STATE: Texas
HDD: 1789
CONSTRUCTION TYPE: Smile Family
DATE: 06/09/03
DATE OF PLANS: 06/09/033
PROJECT INFORMATION:
LOT 1 BLOCK 5 EDELWEISS GARTENS Phase 2
122 KATEN LANE
COLLEGE STATION, TEXAS 77845
COMPANY INFORMATION:
TDT Homes
111012th Man Court
College Station, TX 77845
NOTES:
1426 S/Ft Elan
COMPLIANCE: Passes
Maximum UA = 586
Your Home = 449
23.4% Better Than Code
Gras Glazing
Area or Cavity
Perimeter R Value
Ceiling 1: Flat Ceiling or Scissor Truss
1426 30.0
Wall 1: Wood Frame, 16" o.c.
1503 13.0
Window 'T;,Metal Frame:Douoe Pane with Low E
180
Door 1: Solid
18
Door 2: Glass
18
Floor 1: 'Sh*On-Grade:Unheated, 0.0' insul.
167
Air Conditioner 1: Electric Central Air,12 SEER
Furnace 1: Forced Hot Air, 80 AFUE
Permit Number
Checked By/Date
Cont. or Door
R Value U-Factor UA
0.0 50
3.4 90
0.650 117
0.350 6
0.650 12
0.0 174
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications,
and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC
MECcheck Inspection Checklist
20001ECC
MECcheckSoftware Version 3A Release I
DATE: 06/09/03
TITLE: TDT#161
Bldg.
Dept.
Use I
I
I
[l
[l
[ ]
[l
0
Ceilings:
1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation
Comments:
Above -Grade Walls:
1. Wall 1: Wood Frame, 16" o.c., R 13.0 cavity + R 3.4 continuous insulation
Comments:
Doors:
1. Door 1: Solid, U-factor: 0.350
Comments:
Floors:
1. Floor 1: Slab -On -Grade -Unheated, R-0 (uninsulated)
Comments:
Heating and Cooling Equipment:
1. Air Conditioner 1: Electric Central Air, 12 SEER or higher
Make and Model Number
2. Furnace 1: Forced Hot Air, 80 AFUE or higher
Make and Model Number
Solar Heat Gain Coefficient:
The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly
with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a
3" clearance from insulation.
Materials Identification:
Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
Materials and equipment must be identified so that compliance can be determined
Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
Insulation R values, glazing U-factors, and heating and cooling equipment efficiency must be clearly
marked on the building plans or specifications.
j Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to. .
Ducts outsido the building must be insulated to R 8.0.
i.i
requirements in MECcheckVersion 3A Release la and to comply with the mandatory requirements listed in the MEC check
Inspection Checklist.
Builder/Designer Date rt/
n�
I
I Duct Construction:
{ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted.
I Exception: Continuously welded and locking -type longitudinal joints and seams on ducts
I operating at less than 2 in. w.g. (500 Pa).
[ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] I Air filters are required in the return air system.
[ ] I The HVAC system must provide a means for balancing air and water systems.
I
Temperature Controls:
[ ] I Thermostats are required for ea6h separate HVAC system. A manual or automatic means to
I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
I
I Service Water Heating:
[ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
I water heater has an integral heat trap or is part of a circulating system.
[ ] I Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
[ ] I lnsulate circulating hot water pipes to the levels in Table 1.
I Swimming Pools:
[ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
I Heating and Cooling Piping Insulation:
[ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Rater Pipes.
Insulation Thickness in
Inches by Pipe Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature ( F)
Up to 1"
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Tres Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)