Loading...
HomeMy WebLinkAboutRES2003-01865PREPARED 10/28/03, 12:10:59 INSPECTION TICKET PAGE 3 City of ------------------------------------------------------------------------------------------------ College Station INSPECTOR: BUILDING INSPECTOR DATE 10/28/03 ADDRESS . : 122 KARTEN LN SUBDIV: EDELWEISS GARTENS PH 2 CONTRACTOR : T D T HOMES PHONE : (979) 690-7117 OWNER : EDELWEISS GARTEN VENTURE PHONE : PARCEL : 244030-0205-0010 APPL NUMBER: 03-00001865 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/17/03 CH BLDG, FOUNDATION -SLAB TIME: 17:00 6/18/03 AP 06/17/2003 09:13 AM SSTANLEY ' Early afternoon. B 01 7/11/03 OC BLDG, FRAMING TIME: 17:00 7/11/03 AP 07/11/2003 08:52 AM KELMENDORF B125 01 10/2a,/03 BI 'AP BLDG, FINAL TIME: 17:00 (o aglo3 OC► 10/28/2003 10:12 AM GCARRILLO -------------------------------------- COMMENTS AND NOTES-------------------------------------- Linda Long -''I P-S61 it ion request inspection result, 122 Karten, #03-1865 _ _ - Page 9 From: Brian Henry To: Long, Linda Date: 7/14/03 10:15AM Subject: Insulation request inspection result, 122 Karten, #03-1865 Print for file Inspected insulation, 122 Karten, #03-1865, Benchmark Homes, 7-14-03 Inspection result: Inspected OK for Good Cents. Notes: Connect the fireplace outside air duct. CC: Stanley, Susan CITY OF COLLEGE STATION 0 WOR •REQUEST REQ/JOB: WF0417108 001 CREW: LOCATION: 122 KARTEN LN PAGE 1 PROJECT: REQUEST DPRINT ATE: 6//12%03 PRINT TIME: 9:19:47 SCHEDULE DATES START: 61203 77845 COMPLETION: 6712/03 GEN. LOC: COLLEGE STATION LOC ID: 197872 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: TDT HOMES (690-7117) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE aRr ae -CITY �T SST IO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ---------------------------------------------------------------------------- (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001865 Date 6/10/03 Property Address . . . . . . 122 KARTEN LN Property ID . . 244030-0205-0010 R # . . . . . . . . . . . . . R114637 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 120000 Owner Contractor ------------------------ EDELWEISS GARTEN ------------------------ VENTURE T D T HOMES 311 CECILIA LOOP GLENN THOMAS COLLEGE STATION TX 778456310 1110 12TH MAN COLLEGE STATION TX 77845 (979) 690-7117 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1426.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 247.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . SS Permit Fee . . . . 520.00 Plan Check Fee .00 Issue Date . . . . 6/10/03 Valuation . . . . 120000 Expiration Date . . 12/07/03 Qty Unit Charge Per Extension BASE FEE 460.00 20.00 3.0000 THOU BLDG, VAL 100001-500000 60.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) ------------------ BUILDING P APPLICANT: Z�� - - - - - - - - - - - - - - - - - - - - - - BUILDING PERMIT CITY OF COLLEGE STATIC 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001865 Page 2 Date 6/10/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING.ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE BUILDING DE APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATIC 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001866 Date 6/10/03 Property Address . . . . . . 122 KARTEN LN Property ID . . . . . . . . . 244030-0205-0010 Application description . . . TEMP POLE Subdivision Name . . . . . . EDELWEISS GARTENS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ EDELWEISS GARTEN VENTURE ------------------------ T D T HOMES 311 CECILIA LOOP GLENN THOMAS COLLEGE STATION TX 778456310 1110 12TH MAN COLLEGE STATION TX 77845 (979) 690-7117 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . SS Permit Fee . . . . 20.00 Issue Date . . . . 6/10/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary Charged Paid Credited ------------------------------ Due --------------------------- Permit Fee Total 20.00 20.00 .00 .00 Other Fee Total 45.00 45.00 .00 .00 Grand Total 65.00 65.00 .00 .00 ------------------- BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATI( 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00001865 Date 6/10/03 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Permit Fee Total 520.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1270.00 ------------------- BUILDING DE APPLICANT: Paid Credited Due ------------------------------ 520.00 .00 .00 .00 .00 .00 750.00 .00 .00 1270.00 .00 .00 CITY OF COLLEGE STATION WOR: EQUEST REQ/JOB: WF0416560 / 001 PROJECT: CREW: LOCATION: 122 KARTEN LN 77845 PAGE 1 REQUEST DATE: 6/10/03 PRINT DATE: 6/10/03 PRINT TIME: 16:32:59 SCHEDULE DATES START: 6/1003 COMPLETION: 6710/03 GEN. LOC: COLLEGE STATION LOC ID: 197872 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: T D T HOMES ORIGIN: CUSTOMER -WALK IN USER ID: SSTANLEY AUTH: SSTANLEY WORK TYPE: ROUTINE 4" SEWER 3/4" WATER ------------------------------------------------------------------------------- ------------------------------------------------------------------------------- 4" SEWER 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE Q* ILICATION FOR BUILDING PEI T CITY OF COLLEGE STATION 1101 TEXAS AVENUE F , COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W WW.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: [At, - ,j?e r 4ah DATE (0-10 APPLICAn0N'1 1 TEMP POLE x 0 �— I LOT BLOCK SUBDIVISION R aa? � S �>-�-� 8` ha To BUSINESS/OWNER NAME: %- 7D .T 1A PHONE: Cj o — -7 11 % � CONTRACTOR/HOMEOWNER: PHONE: 14 1 2- -.24 IS CONTRACTOR ADDRESS: I) I ® 15-" 1 R if 6 ( fee_ ELECTRICIAN: ) C- tl e' PLUMBER: Nvn b , r HVAC: &rWA of -I I GOOD CENTS (Residential ordy): C SS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: -"-? i a-i!� lz I, A,C j\ c-uz STRUCTURE USE: O� Lc 4 `rtz I �I HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:' C TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ rC VALUATION: $ • t ' i W, tt C' TOTAL AREA: f4*— HEATED AREA: H (Cost of Labor and Materials lij'UBLIC SEWER NUMBER OF BEDROOMS: 3 SEPTIC/TREATMENT SYSTEM E-EWER TAP:q It SME 0' I�VATER TAP: Sim OTHER TAP: SIZE NUMBER OF BATHROOMS: INTERIOR WALL TYPE: ExTERiOR WALL TYPE: FOUNDATION TYPE: —*L/z TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE Q DOUBLE TRIPLE a ATTACHED Q DETACHED a CARPORT a SIGNATURE OF APPLICANT: Offidal Use Only ants: C., � E or NO Plans Examiner Zoning Official Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating eye 45 �P r v'r a P4%P IVIts- ,J Qaf MECcheck Compliance Report 2000 IECC MECcheck$oft-*are Version 3.4 Release la Data filename: C:\Program Files\Check\MECcheck\MecCheck bcs\161TDT.cck TITLE: TDT#161 CITY: College Station STATE: Texas HDD: 1789 CONSTRUCTION TYPE: Smile Family DATE: 06/09/03 DATE OF PLANS: 06/09/033 PROJECT INFORMATION: LOT 1 BLOCK 5 EDELWEISS GARTENS Phase 2 122 KATEN LANE COLLEGE STATION, TEXAS 77845 COMPANY INFORMATION: TDT Homes 111012th Man Court College Station, TX 77845 NOTES: 1426 S/Ft Elan COMPLIANCE: Passes Maximum UA = 586 Your Home = 449 23.4% Better Than Code Gras Glazing Area or Cavity Perimeter R Value Ceiling 1: Flat Ceiling or Scissor Truss 1426 30.0 Wall 1: Wood Frame, 16" o.c. 1503 13.0 Window 'T;,Metal Frame:Douoe Pane with Low E 180 Door 1: Solid 18 Door 2: Glass 18 Floor 1: 'Sh*On-Grade:Unheated, 0.0' insul. 167 Air Conditioner 1: Electric Central Air,12 SEER Furnace 1: Forced Hot Air, 80 AFUE Permit Number Checked By/Date Cont. or Door R Value U-Factor UA 0.0 50 3.4 90 0.650 117 0.350 6 0.650 12 0.0 174 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC MECcheck Inspection Checklist 20001ECC MECcheckSoftware Version 3A Release I DATE: 06/09/03 TITLE: TDT#161 Bldg. Dept. Use I I I [l [l [ ] [l 0 Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R 13.0 cavity + R 3.4 continuous insulation Comments: Doors: 1. Door 1: Solid, U-factor: 0.350 Comments: Floors: 1. Floor 1: Slab -On -Grade -Unheated, R-0 (uninsulated) Comments: Heating and Cooling Equipment: 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number 2. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number Solar Heat Gain Coefficient: The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Materials Identification: Materials and equipment must be installed in accordance with the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R values, glazing U-factors, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. j Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to. . Ducts outsido the building must be insulated to R 8.0. i.i requirements in MECcheckVersion 3A Release la and to comply with the mandatory requirements listed in the MEC check Inspection Checklist. Builder/Designer Date rt/ n� I I Duct Construction: { ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. I Exception: Continuously welded and locking -type longitudinal joints and seams on ducts I operating at less than 2 in. w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: [ ] I Thermostats are required for ea6h separate HVAC system. A manual or automatic means to I partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. I I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the I water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: [ ] I lnsulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 OF must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Rater Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Tres Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only)