Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-01850
A A 400 Iwo PREPARED 1/14/04, 12:15:04 PREPARED 1/14/04, 12:15:04 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 1/14/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 111 HARTFORD DR SUBDIV: EDELWEISS GARTENS PH 2 CONTRACTOR : 5 STAR HOMES PHONE : (979) 696-0335 OWNER : EDELWEISS GARTEN VENTURE PHONE : PARCEL : 244030-0205-0160 APPL NUMBER: 03-00001850 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/30/03 DS BLDG, FOUNDATION -SLAB TIME: 17:00 6/30/03 AP 06/27/2003 03:02 PM SSTANLEY STRINGS ON SETBACKS OKAY SLAB GROUND BACK LEFT SIDE B115 01 8/05/03 DS BLDG, FRAMING TIME: 17:00 8/05/03 DP 08/05/2003 08:21 AM MALFORD NEEDS FULL SHEET OF OSB FOR WIND BRACING IN MASTER BEDROOM BETWEEN WINDOWS. ANCHOR NUTS LOOSE OR MISSING THROUGH OUT HOUSE. NEEDS TO SHEETROCK FIREPLACE TOP. NEEDS TO REPLACE PERLIN BRACE KNOCKED OUT FOR RETURN AIR. B115. 02 8/13/03 DS BLDG, FRAMING TIME: 17:00 8/13/03 AP 08/12/2003 02:12 PM SSTANLEY B125�01 1/14/04 BI BLDG, FINAL TIME: 17:00 01/14/2004 09:13 AM GCARRILLO ----------------------------------- CONTINUED ONTO NEXT PAGE ----------------------------------- 4 V CITY OF COLLEGE STATION WORK REQUEST PAGE 1 REQ/JOB: WF0421283 / 001 PROJECT: REQUEST DATE: 6/25/03 PRINT DATE: 6/25/03 CREW: PRINT TIME: 13:27:43 SCHSTARRT.DATES DULLOCATION: 111 HARTFORD DR 6/25/03 77845 COMPLETION: 6/25/03 GEN. LOC: COLLEGE STATION LOC ID: 197500 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: 5 STAR HOMES (696-0335) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE CITY OF COLLEGE STATION WORu REQUEST PAGE 1 REQ/JOB: WF0417566 001 - FROJECT: REQUEST DATE: 6/13/03 PRINT DATE: 6/13/03 CREW: PRINT TIME: 11:13:34 SCHEDULE LOCATION: 111 HARTFORD DR START:DATES 6/13/03 77845 COMPLETION: 6/13/03 GEN. LOC: COLLEGE STATION LOC ID: 197500 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: 5 STAR HOMES (696-0335) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID . Assigned Department: OT-CUSTOMER SERVICE k a BUILDING PERMIT CITY OF • COLLEGE STATI A*rw�a=-�,. COLLEGE STATION, TX 7784D PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001850 Date 6/11/03 Property Address . . . . . . 111 HARTFORD DR Property ID . . 244030-0205-0160 R # . . . . . . . . . . . . . R114652 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 102960 Owner Contractor ------------------------ ------------------------ EDELWEISS GARTEN VENTURE 5 STAR HOMES 311 CECILIA LOOP RUSSELL ERICKSON COLLEGE STATION TX 778456310 PO BOX 9229 COLLEGE STATION TX 77842 (979) 696-0335 -------------------------- Structure Information --------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1560.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 247.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc LL Permit Fee . . . . 469.00 Plan Check Fee .00 Issue Date . . . . 6/11/03 Valuation . . . . 102960 Expiration Date . . 12/08/03 Qty Unit Charge Per Extension BASE FEE 460.00 3.00 3.0000 THOU BLDG, VAL 100001-500000 9.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) ---------------------------------------i---------------------- BUILDING DEPT REPRESENTATIVE• APPLICANT: BUILDING PERMIT CITY OF COLLEGE STAT"- 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 03-00001850 Page 2 Date 6/11/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) POST PERMIT CARD ON JOB SITE RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE Provide site plan House is encroaching, Max. width of structure shall not BUILDING DE APPLICANT: BUILDING PERMIT CITY OF COLLEGE STAT---- 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00001850 Date 6/11/03 ---------------------------------------------------------------------------- Special Notes and Comments exceed 40 foot. ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged Paid Credited ---------- Due Permit Fee Total ---------- 469.00 ---------- 469.00 ---------- .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1219.00 1219.00 .00 .00 ---------------------------- -- - ---------------------- BUILDING DEPT REPRESEENTTAATIVE: APPLICANT:���/�- TEMPORARY POLE PERMIT CITY OF COLLEGE STAT---- 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001851 Date 6/11/03 Property Address . . . . . . 111 HARTFORD DR Property ID . . . . . . . . . 244030-0205-0160 Application description . . . TEMP POLE Subdivision Name . . . . . . EDELWEISS GARTENS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ EDELWEISS GARTEN VENTURE 5 STAR HOMES 311 CECILIA LOOP RUSSELL ERICKSON COLLEGE STATION TX 778456310 PO BOX 9229 COLLEGE STATION TX 77842 (979) 696-0335 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc LL Permit Fee 20.00 Issue Date . . . . 6/11/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Permit Fee Total Other Fee Total Grand Total Charged Paid -------------------- 20.00 20.00 45.00 45.00 65.00 65.00 Credited Due -------------------- .00 .00 .00 .00 .00 .00 --------------------------- - 71---------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: E3AP CATION FOR BUILDING PER CITY ...F COLLEGE STATION 1101 TEXAS AVENUE -COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX zz WWW.CI.COLLEGE-STATION.TX.US APPLICATION # DATE OF APPLICATION: TEMP POLE # WORK LOCATION/ADDRESS:doW LOT 4 BLOCK SUBDIVISION PROJECT/BUSINESS NAME: PHONE: zA� CONTRACTOR/HOMEOWNER: T"esf' r� �S PHONE: 4qt - 633t!!SP ELECTRICIAN: ei?_ PLUMBER: rl HVAC: CLASS OF WORK ACCESSORY/STORAGE ADDITION DEMOLITION LOCATION DESCRIPTION OF WORK: STRUCTURE USE: 's k MOVING NEW CONSTRUCTION REMODEURENOVATION RE -ROOF SHELL ONLY SIGN SLAB ONLY SWIMMING POOL 0 EST. COSTNALUATION: $ c) TOTALAREA: Q 46- HEATED AREA: NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: En SEWER TAP: L /e ATER TAP: SIZE/ / SIZE Q OTHER TAP: Sim a TEMP POLE GARAGE TYPE: a SINGLE ATTACHED SIGNATURE OF APPLICANT: PUBLIC SEWER SEPTIC/TREATMENT SYSTEM INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF YPE: .DOUBLE a DETACHED a Official Use Only TRIPLE CARPORT Plans Examiner Zoning Official Comments: YES NO Energy Code Compliance Information % Glazing of exterior walls Insulation R value of exterior walls 1e3 Insulation R value of ceiling 1 (flat areas) ,-;6 Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork AIC SEER rating APPL,...ATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX. US ADDRESS/LOCATION: LOT BLOCK SUBDIVISION BUSINESS/OWNER NAME: CONTRACTOR/HOMEOWNER: CONTRACTOR ADDRESS: ELECTRICIAN: HVAC: For Office Use 0* DATE: APPLICATION # TEMP POLE # SEC/PH PHONE: PHONE: PLUMBER: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE ADDITION DEMOLITION (Asbestos Survey) DUPLEX (Landscape Plans Req) DESCRIPTION OF WORK: LOCATION MOVING NEW CONSTRUCTION REMODEURENOVATION RE -ROOF (Total/Partial) SHELL ONLY SLAB ONLY SWIMMING POOL STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA: HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: ❑ SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: ❑ SEWER TAP: INTERIOR WALL TYPE: SIZE WATER TAP: EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: SIZE TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE F_� DOUBLE F__j TRIPLE a ATTACHED Q DETACHED a CARPORT a SIGNATURE OF APPLICANT: Official Use Only Comments: YES or NO Plans Examiner Zoning Official w MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 06/08/03 DATE OF PLANS: Dec. 2002 PROJECT INFORMATION: Hartford Drive COMPANY INFORMATION: 5 Star Homes PO Box 11131 College Station TX 77842 NOTES: 1560 Heated Area COMPLIANCE: Passes Maximum UA = 2894 Your Home = 2523 12.8% Better Than Code Ceiling 1: Flat Ceiling or Scissor Truss Wall 1: Steel Frame, 16" o.c. Wmdow 1: Vinyl Frame, Double Pane with Low-E Window 2: Wood Frame, Double Pane Window 3: Vinyl Frame, Double Pane Door 1: Solid Door 2: Solid Door 3: Glass Slab 1: Unheated, 0.0' insul. Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 12 SEER Gross Area or Cavity Perimeter R Value D3-1850 Permit Number Checked By/Date Glazing Cont. or Door R Value U Factor UA 1560 30.0 0.0 55 1789 13.0 2.8 139 215 0.360 77 4 0.600 2 15 0.500 8 20 0.170 3 19 0.040 1 19 0.170 3 2145 0.0 2235 COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in MECcheck Version 3.2 Release lb. Builder/Designer Date of MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 06/08/03 Bldg. Dept I Use I Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R 30.0 cavity insulation Comments: Above -Grade Walls: [ ] I 1. Wall 1: Steel Frame, 16" o.c., R 13.0 cavity + R 2.8 continuous insulation I Comments: Windows: 1. Window 1: Vinyl Frame, Double Pane with Low E, U-factor: 0.360 For windows without labeled U factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 2. Window 2: Wood Frame, Double Pane, U factor: 0.600 For windows without labeled U factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 3. Window 3: Vinyl Frame, Double Pane, U-factor: 0.500 For windows without labeled U factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: .Doors: 1. Door 1: Solid, U-factor: 0.170 Comments: 2. Door 2: Solid, U-factor: 0.040 Comments: 3. Door 3: Glass, U factor: 0.170 # Panes Frame Type Comments: Slab -On -Grade Floors: 1. Slab 1: Unheated, R-0 (uninsulated) Comments: Thermal Break? [ ] Yes [ ] No Heating and Cooling Equipment: 1. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number 2. Air Conditioner 1: Electric Central Air,12 SEER or higher Make and Model Number The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate I air tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Materials Identification: [ ] I Materials and equipment must be installed in accordant to the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. I l I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R values, glazing U values, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: Ducts in unconditioned spaces must be insulated to R 5. Ducts outside the building must be insulated to R 8.0. Duct Construction: All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. Cooling ducts with exterior insulation must be covered with a vapor retarder. Air filters are required in the return air system. The HVAC system must provide a means for balancing air and water systems. Temperature Controls: Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] I HVAC piping conveying fluids above 105 OF or chilled fluids below 55 °F must be insulated to the I levels in Table 2. Table 1: M idnmm Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1„ Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for RVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Pining System Tvaes Range 2" Runouts l" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) T I.m 1 .9 a ,© 0 - d -� u I 9o,dot