HomeMy WebLinkAboutRES2003-01848PREPARED 10/23/03, 12:08:55 INSPECTION TICKET PAGE 5 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 10/23/03 ------------------------------------------------------------------------------------------------ ADDRESS . : 109 HARTFORD DR SUBDIV: EDELWEISS GARTENS PH 2 CONTRACTOR 5 STAR HOMES PHONE : (979) 696-0335 OWNER EDELWEISS GARTEN VENTURE PHONE : PARCEL 244030-0205-0150 APPL NUMBER: 03-00001848 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 6/24/03 OC BLDG, FOUNDATION -SLAB TIME: 17:00 6/25/03 AP 06/24/2003 09:14 AM SSTANLEY SETBACKS PER STRINGS. SLAB GROUND @ RIGHT BACK B O1 7/31/03 DS BLDG, FRAMING TIME: 17:00 8/01/03 AP 07/31/2003 12:02 PM SSTANLEY NEEDS TOP OUT B125 01 �1+0/23/03 BI BLDG, FINAL TIME: 17:00 2 / 4V6,1-_ 10/23/2003 09:00 AM SSTANLEY 60 ---------------- --- COMMENTS AND NOTES-------------------------------------- 0 �00 tqql CITY OF COLLEGE STATION WORTz REQUEST PAGE 1 REQ/JOB: WF0416872 001 PROJECT: REQUEST DATE: ffil/03 PRINT DATE: 1/03 CREW: PRINT TIME: 12:22:48 SCHEDULE DATES LOCATION: 109 HARTFORD DR 03 77845 COMPLETION: 6711/03 GEN. LOC: COLLEGE STATION LOC ID: 197498 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: 5 STAR HOMES (696-0335) ORIGIN: CUSTOMER -WALK IN USER ID: LLONG AUTH: LLONG WORK TYPE: ROUTINE 4" SEWER AND 3/4" WATER 4" SEWER AND 3/4" WATER Category code CS -CUSTOMER SERVICES CSCS Task code: . SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE %q BUILDING PERMIT L E-.S TIr-- 4. ` 1101�� AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001848 Date 6/11/03 Property Address . . . . . . 109 HARTFORD DR Property ID . . 244030-0205-0150 R # . . . . . . . . . . . . . R114651 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . EDELWEISS GARTENS PH 2 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 99660 Owner Contractor ------------------------ ------------------------ EDELWEISS GARTEN VENTURE 5 STAR HOMES 311 CECILIA LOOP RUSSELL ERICKSON COLLEGE STATION TX 778456310 PO BOX 9229 COLLEGE STATION TX 77842 (979) 696-0335 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL-SFR/DUPLEX Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) ATT HEATED AREA 1510.00 INTERIOR WALL TYPE SHEETROCK NUMBER OF BATHROOMS 2.00 NUMBER OF BEDROOMS 3.00 SEWER TYPE PUBLIC SERIAL ZONES 247.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . LL Permit Fee . . . . 460.00 Plan Check Fee .00 Issue Date . . . . 6/11/03 Valuation . . . . 99660 Expiration Date . . 12/08/03 Qty Unit Charge Per Extension BASE FEE 260.00 50.00 4.0000 THOU BLDG, VAL 50001-100000 200.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTER (S ) --------------------------------------------- ----- ---------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF ggLLEGE STAT---- 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 Application Number . . . . . 03-00001848 Page 2 Date 6/11/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) POST PERMIT CARD ON JOB SITE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------- BUILDING DEPT REPRESENTATIVE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STAT 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00001848 Date 6/11/03 ---------------------------------------------------------------------------- Special Notes and Comments Provide site plan ---------------------------------------------------------------------------- / Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary ----------------- Charged ---------- Paid ---------- Credited Due -------------------- Permit Fee Total 460.00 460.00 .00 .00 Plan Check Total .00 .00 .00 .00 Other Fee Total 750.00 750.00 .00 .00 Grand Total 1210.00 1210.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: AP CATION FOR BUILDING PEP CIT . _F COLLEGE STATION 1101 TEXAS AVENUE - COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX WWW CI COLLEGE STATION TX US APPLICATION # 1103- 1 p 3 ' DATE OF APPLICATION: TEMP POLE # 0 �\ 1,0 WORK LOCATIONDRESS:_ m �. �,. .n.t.� f„• LOT 9; BLOCK PROJECT/BUSINESS NAME: 2 SUBDIVISION PHONE: CONTRACTOR/HOMEOWNER: � ����` �o �.�. -PHONE:_/ a�� 03-3-65 ELECTRICIAN: u.+� �r, �o�� PLUMBER: HVAC: �. �-+ r ��/. �. �.� CLASS OF WORK ACCESSORY/STORAGE MOVING SHELL ONLY ADDITION NEW CONSTRUCTION SIGN DEMOLITION REMODEURENOVATION SLAB ONLY LOCATION RE -ROOF SWIMMING POOL DESCRIPTION OF WORK: /C'---� 'A'>'O' , STRUCTURE USE: �..'A t �, �10/ Xa o 0 EST. COST1VALUATION: $ NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: SEWER TAP: L Size , WATER TAP: Size Q OTHER TAP: SIZE a TEMP POLE GARAGE TYPE: a SINGLE NATTACHED SIGNATURE OF APPLICANT: TOTAL AREA: : HEATED AREA: PUBLIC SEWER SEPTIC/TREATMENT SYSTEM INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: DOUBLE a El DETACHED ED TRIPLE CARPORT / Ofcial Use Only Plans Examiner Zoning Official Comments: YES NO Energy Code Compliance Information % Glazing of exterior walls - f Insulation R value of exterior wails Insulation R value of ceiling 1 (flat areas) Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC Glazing U-Factor R value of ductwork A/C SEER rating APPL.-,ATION FOR BUILDING PERMIT CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COLLEGE-STATION.TX.US ADDRESS/LOCATION: LOT BLOCK BUSINESS/OWNER NAME: SUBDIVISION CONTRACTOR/HOMEOWNER: CONTRACTOR ADDRESS: Fdr oTice use only DATE: APPLICATION # TEMP POLE # SEC/PH PHONE: PHONE: ELECTRICIAN: PLUMBER: HVAC: GOOD CENTS (Residential only): CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) NEW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans REMODEURENOVATION SWIMMING POOL Req) DESCRIPTION OF WORK: STRUCTURE USE: HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (TAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ TOTAL AREA: HEATED AREA: (Cost of Labor and Materials) PUBLIC SEWER NUMBER OF BEDROOMS: SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS: ❑ SEWER TAP: INTERIOR WALL TYPE: SIZE WATER TAP: EXTERIOR WALL TYPE: SIZE OTHER TAP: FOUNDATION TYPE: SIZE ❑ TEMP POLE ROOF TYPE: GARAGE TYPE: SINGLE DOUBLE F__j TRIPLE ATTACHED E] DETACHED a CARPORT a SIGNATURE OF APPLICANT: Official Use Only Comments: YES or NO Plans Examiner Zoning Official ! w Permit Number MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb Checked By/Date CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 06/08/03 DATE OF PLANS: DEC, 2002 PROJECT INFORMATION: Hartford Drive COMPANY INFORMATION: 5 Star Homes PO Box 11131 College Station TX 77542 NOTES: 1510 Heated Area COMPLIANCE: Passes Maximum UA = 2801 Your Home = 2425 13.4% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R Value R Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 1510 30.0 0.0 53 Wall 1: Wood Frame, 16" o.c. 1563 13.0 2.8 95 Window 1: Vinyl Frame, Double Pane with Low-E 167 0.360 60 Window 2: Wood Frame, Double Pane 7 0.600 4 Window 3: Vinyl Frame, Double Pane 15 0.500 8 Door 1: Solid 20 0.170 3 Door 2: Solid 19 0.040 1 Door 3: Glass 19 0.170 3 Slab 1: Unheated, 0.0' insul. 2109 0.0 2198 Furnace 1: Forced Hot Air, 80 AFUE Air Conditioner 1: Electric Central Air, 12 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in MECcheck Version 3.2 Release lb. Builder/Designer Date MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 06/08/03 Bldg. Dept. Use [ ] [ ] [l [ ] [ ] [ ] [ ] Ceilings: 1. Ceiling 1: Flat Ceiling or Scissor Truss, R 30.0 cavity insulation Comments: Above -Grade Walls: 1. Wall 1: Wood Frame, 16" o.c., R 13.0 cavity + R 2.8 continuous insulation Comments: Windows: 1. Window 1: Vinyl Frame, Double Pane with Low E, U-factor: 0.360 For windows without labeled U factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 2. Window 2: Wood. Frame, Double Pane, U factor: 0.600 For windows without labeled U factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: 3. Window 3: Vinyl Frame, Double Pane, U factor: 0.500 For windows without labeled U factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: Doors: 1. Door 1: Solid, U-factor: 0.170 Comments: 2. Door 2: Solid, U factor: 0.040 Comments: 3. Door 3: Glass, U-factor: 0.170 # Panes Frame Type Comments: Slab -On -Grade Floors: 1. Slab 1: Unheated, R 0 (uninsulated) Comments: Thermal Break? [ ] Yes [ ] No Heating and Cooling Equipment: [ ] f 1. Furnace 1: Forced Hot Air, 80 AFUE or higher Make and Model Number [ ] 2. Air Conditioner 1: Electric Central Air, 12 SEER or higher I Make and Model Number [ ] The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. Materials Identification: [ ] Materials and equipment must be installed in accordint to the manufacturer's installation instructions. [ ] Materials and equipment must be identified so that compliance can be determined. [ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] Insulation R values, glazing U-values, and heating and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R 5. Ducts outside the building must be insulated to R 8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] ( Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pine Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to 1" U_R to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Range 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) 1 Q I I f _ I i 1 s.00' ZDELWET55 CARTE f�Ni�SE-2 13LK -S LOT 15 1 a��