HomeMy WebLinkAboutRES2003-01786PREPARED
3/01/04, 12:07:34
INSPECTION TICKET PAGE 2
City of
------------------------------------------------------------------------------------------------
College Station
INSPECTOR: BUILDING INSPECTOR DATE 3/01/04
ADDRESS
. : 1004 MUIRFIELD VILLAGE SUBDIV: PEBBLE CREEK
CONTRACTOR : SOUTHERN ESTATE HOMES PHONE : (979) 690-9096
OWNER
: ROBERTSON, JOHN D
& SUSAN PHONE :
PARCEL
: 497900-0007-0140
APPL NUMBER: 03-00001786 RESIDENTIAL, 1 UNIT DETACHED NEW
------------------------------------------------------------------------------------------------
PERMIT:
BLDG 00 BUILDING PERMIT
REQUESTED INSP
DESCRIPTION
TYP/SQ
COMPLETED RESULT
RESULTS/COMMENTS
------------------------------------------------------------------------------------------------
B100 01
6/09/03 CH
BLDG, FOUNDATION -SLAB TIME: 17:00
6/10/03 AP
06/09/2003 12:26 PM SSTANLEY
SETBACK STRINGS PULLED
SLAB GROUND BACK RIGHT
Bl1: 01
9/02/03 TB
BLDG, FRAMING TIME: 17:00
9/02/03 AP
09/02/2003 08:31 AM SSTANLEY
09/03/2003 07:23 AM MALFORD
i
sheetrock at top of fireplace not plywood
glass over mst. tub not tempered, it should be by building
final
B130 01
9/10/03 TB
BLDG, INSULATION TIME: 17:00
9/11/03 AP
B125 01 2/27/04 OC BLDG, FINAL TIME: 17:00
2/27/04 DP 02/26/2004 01:45 PM SSTANLEY
Need Address
B125 02 3/0 /04 BI BLDG, FINAL TIME: 17:00
01/0t/ A( 0 C 03/01/2004 10:10 AM SSTANLEY
-------------------------------------- COMMENTS AND NOTES--------------------------------------
CITY OF COLLEGE STATION
WOP :EQUEST
PAGE
1
REQ/JOB: WF0414350 / 001 PROJECT:
REQUEST DATE:
6/03/03
PRINT DATE:
6/03/03
CREW:
PRINT TIME:
14:06:16
SCHEDULE
DATES
LOCATION: 1004 MUIRFIELD VILLAGE
START:
/
77845
COMPLT ON:
6/0303
GEN. LOC: COLLEGE STATION LOC ID: 131754
REF NBR:
REQ DEPT: DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR: SOUTHERN ESTATE HOMES ORIGIN:
CUSTOMER -WALK
IN
USER ID: KELMENDORF AUTH: KELMENDORF WORK TYPE:
ROUTINE
3/4" WATER 4" SEWER
3/4" WATER 4" SEWER
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
P--�
15Ar7m
L AM
CITY OF COLLEGE STATION
WORK REQUEST
PAGE
1
REQ/JOB:
WF0414735 / 001 PROJECT:
REQUEST DATE:
6/04/03
PRINT DATE:
6/04/03
CREW:
PRINT TIME:
12:10:52
SCHEDULE
DATES
LOCATION:
1004 MUIRFIELD VILLAGE
START:
?7845
COMPLT ON:
6/04/03
GEN. LOC:
COLLEGE STATION LOC ID: 131754
REF NBR:
REQ DEPT:
DE -BUILDING INSPECTION PRIORITY:
NORMAL
REQUESTOR:
SOUTHERN ESTATE (690-9096) ORIGIN:
CUSTOMER -WALK
IN
USER ID:
LLONG AUTH: LLONG WORK TYPE:
ROUTINE
TEMP POLE
PASSED
TEMP POLE PASSED
Category code CS -CUSTOMER SERVICES CSCS
Task code: SET UP NEW UTILITY ACCT SET
Facility ID .
Assigned Department: OT-CUSTOMER SERVICE
SUlLDINU PERMil'
--CITY• OF COLLEGE- STATIO "
XAS• AVE.
COLLEGE STATION, TX 77846
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number .
. . . . 03-00001786 Date 6/03/03
Property Address . .
. . . . 1004 MUIRFIELD VILLAGE
Property ID . . . . .
. . . . 497900-0007-0140
R ## . . . . . . . . .
. . . . R88887
Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW
Subdivision Name . .
. . . . PEBBLE CREEK
Property Use . . . .
. . . . RESIDENTIAL
Property Zoning . . .
. . . . SINGLE FAMILY RESIDENTIAL
Application valuation
. . . . 260000
Owner
Contractor
------------------------ ------------------------
ROBERTSON, JOHN D & SUSAN SOUTHERN ESTATE HOMES
2817 JENNIFER DR
NOBLE HANDY
COLLEGE STATION
TX 778455719 PO BOX 10231
COLLEGE STATION TX 77840
(979) 690-9096
--------------------------
Structure Information -------------------------
Construction Type . .
. . . COMBUSTIBLE (UNPROTECTED)
Occupancy Type . . .
. . . RESIDENTIAL-SFR/DUPLEX
Other struct info . .
. . . EXTERIOR WALL TYPE BRICK
IMPACT/PRORATA FEES PAID NA
FOUNDATION TYPE SLAB
NUMBER OF GARAGE BAYS 3.00
HEATED AREA 3016.00
INTERIOR WALL TYPE SHEETROCK
NUMBER OF BATHROOMS 3.00
NUMBER OF BEDROOMS 4.00
SEWER TYPE PUBLIC
SERIAL ZONES 252.00
----------------------------------------------------------------------------
Permit . . . . . .
BUILDING PERMIT
Additional desc . .
KE
Permit Fee . . . .
940.00 Plan Check Fee .00
Issue Date . . . .
6/03/03 Valuation . . . . 260000
Expiration Date . .
11/30/03
Qty Unit Charge
Per Extension
BASE FEE 460.00
160.00 3.00.00
THOU BLDG, VAL 100001-500000 480.00
----------------------------------------------------------------------------
Special Notes and Comments
ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING
UNIT BEDROOMS SHALL
BE PROTECTED BY AN ARC -FAULT CIRCUIT
INTERRUPTERS)
PROVIDE ATTIC ACCESS
WITHIN 20 FEET OF MECHANICAL EQUIPMENT
----------------------------------------
BUILDING DEPT REPRESF�ATIVE:_
----- - - -----------------
-
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATIC
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979) 764-3570 FAX: (979) 764-3496
Application Number . . . . . 03-00001786
Page 2
Date 6/03/03
Special Notes and Comments
PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH
AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION
AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE
CONCENTRATION, RATE OF APPLICATION AND TREATMENT
METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL.
PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER
CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE
ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS
MINIMUM FOUNDATION STANDARD - ALL FOUNDATION SHALL COMPLY
WITH THE MINIMUM FOUNDATION STANDARD AS PER CITY'S
ORDINANCE (FOUNDATION DETAIL SHALL BE SHOWN ON PLANS)
ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL
CODE
PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER
ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER
PENETRATIONS SEALED
INTERIOR BEAMS > 60' MUST BE A MINIMUM OF 30" DEEP
PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO
BE ELEVATED TO ALLOW FOR ATTIC INSULATION
IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR
TO CERTIFICATE OF OCCUPANCY.
CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND
7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA)
POST PERMIT CARD ON JOB SITE
WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED
PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE
MAXIMUM STATIC WATER PRESSURE TO 80 PSI
RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL
BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE
PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF
THE PUBLIC RIGHT-OF-WAY.
ADD SMOKE DETECTOR(S) PER NOTES ON PLANS
PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND
EASEMENTS ON FOUNDATION INSPECTION.
THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED
FENESTRATION PRODUCTS SHALL NOT EXCEED .4
SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY
BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH
SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE
BEDROOMS
REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA
PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM
BUILDING
APPLICANT
BUILDING PERMIT
CITY OF COLLEGE STATIC
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Page
3
Application Number . . . . .
03-00001786
Date
6/03/03
----------------------------------------------------------------------------
Special Notes and Comments
VEGETATION AND FOREIGN MATERIAL.
TEMPERED GLASS REQUIRED WITHIN
24" OF DOORS
AN APPROVED DEVICE FOR THERMAL
EXPANSION CONTROL
SHALL BE
PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER
HEATING
EQUIPMENT AND A PRESSURE REDUCING VALVE
----------------------------------------------------------------------------
Other Fees . . . . . . . . .
SEWER TAP 4" CITY
INSTALL
350.00
WATER TAP 3/4" CITY INSTL
400.00
Fee summary Charged
---------------------------
Paid Credited
------------------------------
Due
Permit Fee Total 940.00
940.00
.00
.00
Plan Check Total .00
.00
.00
.00
Other Fee Total 750.00
750.00
.00
.00
Grand Total 1690.00
1690.00
.00
.00
-----------------
BUILDING
APPLICANT
TEMPORARY POLE PERMIT
CITY OF COLLEGE STATIC,
1101 TEXAS AVE
COLLEGE STATION, TX 77840
PHONE: (979)764-3570 FAX: (979)764-3496
----------------------------------------------------------------------------
Application Number . . . . . 03-00001788 Date 6/03/03
Property Address . . . . . . 1004 MUIRFIELD VILLAGE
Property ID . . 497900-0007-0140
R. # . . . . . . . . . . . . . R88887
Application description . . . TEMP POLE
Subdivision Name . . . . . . PEBBLE CREEK
Property Use . . . . . . . . RESIDENTIAL
Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL
Application valuation . . . . 0
Owner Contractor
------------------------ ------------------------
ROBERTSON, JOHN D & SUSAN SOUTHERN ESTATE HOMES
2817 JENNIFER DR NOBLE HANDY
COLLEGE STATION TX 778455719 PO BOX 10231
COLLEGE STATION TX 77840
(979) 690-9096
----------------------------------------------------------------------------
Permit . . . . . . TEMP POLE PERMIT
Additional desc . . KE
Permit Fee . . . . 20.00
Issue Date . . . . 6/03/03 Valuation . . . . 0
Fee summary
-----------------
Permit Fee Total
Grand Total
----------------
BUILDING
APPLICAN'
Charged
20.00
20.00
Paid
20.00
20.00
Credited
.00
.00
Due
.00
.00
For ORke Use Only
APPLICATION FOR BUILDING PERMIT DATE:
CITY OF COLLEGE STATION APPLICATION #1101 TEXAS AVENUE
EWA
COLLEGE STATION, TX 77840 TEMP POLE #
(979) 764-3570 (979) 764-3496 FAX
W W W.CI.COLLEG E-STATION.TX. US
_ o
ADDRESS/LOCATION:�(�l77�/C
LOT -�- BLOCK r SUBDIVISION
BUSINESS/OWNER NAME: PHONE:
CONTRACTOR/HOMEOWNER: �/t!✓ �- PHONE: CONTRACTOR ADDRESS: l% �j 6 -a 3 Z2 %)!
ELECTRICIAN: c/ ./���� PLUMBER:
HVAC: �U &GAO GOOD CENTS (Residential only):
CLASS OF WORK
ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial)
ADDITION MO ING SHELL ONLY ,
DEMOLITION (Asbestos Survey) EW CONSTRUCTION SLAB ONLY
DUPLEX (Landscape Plans Req)' REMODEURENOVATION SWIMMING POOL .
DESCRIPTION OF WORK: ef�.'e s5;
3
,s
�e2rm�K� STRUCTURE USE:
HOMEOWNER ASSOCIATION/ARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL:
TEXAS ACCESSIBILITY STANDARD (fAS) PROJECT REGISTRATION# EABPRJ '
'bALUATION: $ TOTAL AREA: %� �f HEATED AREA: 1
(Cost of Labor and Materials)
PUBLIC SEWER NUMBER OF BEDROOMS: v
SEPTIC/TREATMENT SYSTEM NUMBER OF BATHROOMS:
SEWER TAP: , INTERIOR WALL TYPE:
S¢E
ATER TAP: � EXTERIOR WALL TYPE:
SIZE
OTHER TAP: FOUNDATION TYPE:
SIZE
TEMP POLE ROOF TYPE:�p
GARAGE TYPE: SINGLE F-1 DOUBLE a TRIPLE
ATTACHED F__� DETACHED Q CARPORT
SIGNATURE OF APPLICANT:
Official Use Only
`j`� ww22 ents:
�J YE or NO
Plans Examiner Zoning Official
A�
U
14
0
MECcheck Compliance Report
2000 IECC
MECcheck Software Version 3.2 Release lb
TITLE: 7783L
CITY: College Station
STATE: Texas
HDD: 1788
CONSTRUCTION TYPE: Single Family
DATE: 06/01/03
DATE OF PLANS: 01/28/03
PROJECT INFORMATION:
SUE ROBERTSON HOME
MUIRFIELD DR. PEBBLE CREEK
COMPANY INFORMATION:
SOUTHERN ESTATE HOMES,INC.
COMPLIANCE: Passes
Maximum UA = 641
Your Home = 551
14.0% Better Than Code
Permit Number
Checked By/Date
Gross Glazing
Area or Cavity Cont. or Door
Perimeter R-Value R-Value U-Factor UA
Ceiling 1: Flat Ceiling or Scissor Truss 3016 30.0 0.0 106
Wall 1: Wood Frame, 16" o.c. 2547 13.0 0.0 165
Window 1: Metal Frame, Double Pane with Low-E 365 0.580 212
Door 1: Glass 84 0.058 5
Door 2: Solid 84 0.750 63
Air Conditioner 1: Electric Central Air, Q
COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans,
specifications, and other calculations submitted with the permit application. The proposed building has been
designed to meet the 2000 IECC requirements in MECcheck Version 3.2 Release lb.
Builder/Designer Date
y
M ECcheck Inspection Checklist
2000 IECC
MECcheck Software Version 3.2 Release lb
DATE: 06/01/03
TITLE: 7783E
Bldg.
Dept.
Use
I
Ceilings:
[ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R 30.0 cavity insulation
Comments:
I
Above -Grade Walls:
[ ] I 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation
I Comments:
I
Windows:
[ ] I 1. Window 1: Metal Frame, Double Pane with Low-E, U-factor: 0.580
For windows without labeled U-factors, describe features:
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
I Comments:
Doors:
[ ] I 1. Door 1: Glass, U-factor: 0.058
# Panes Frame Type Thermal Break? [ ] Yes [ ] No
Comments:
[ ] I 2. Door 2: Solid, U-factor: 0.750
I Comments:
i
Heating and Cooling Equipment:
[ ] I 1. Air Conditioner 1: Electric Central Air, 10 SEER or higher
Make and Model Number
I
[ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC
values must be determined in accordance with the NFRC test procedure or taken from the default table.
Air Leakage:
[ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air
leakage must be sealed.
[ ] I Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate
air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation.
Materials Identification:
[ ] I Materials and equipment must be installed in accordint to the manufacturer's installation instructions.
[ ] I Materials and equipment must be identified so that compliance can be determined.
[ ] I Manufacturer manuals for all installed heating and cooling equipment and service water heating
equipment must be provided.
[ ] I Insulation R-values and glazing U-values must be clearly marked on the building plans or specifications.
I
Duct Insulation:
[ ] Ducts in unconditioned spaces must be insulated to R 5.
Ducts outside the building must be insulated to R-8.0.
Duct Construction:
[ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics
(adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception:
Continuously welded and locking -type longitudinal joints and seams on ducts operating at
less than 2 in. w.g. (500 Pa).
[ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions.
[ ] Cooling ducts with exterior insulation must be covered with a vapor retarder.
[ ] Air filters are required in the return air system.
[ ] The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
[ ] Thermostats are required for each separate HVAC system. A manual or automatic means to
partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
[ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the
water heater has an integral heat trap or is part of a circulating system.
[ ] Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
[ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20%
of the heating energy is from non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
[ ] HVAC piping conveying fluids above 105 °F or chilled fluids below 55 OF must be insulated to the
levels in Table 2.
Table 1: Minimum Insulation Thickness for Circulating Hot Rater Pipes.
Insulation Thickness in
Inches byPi e
Sizes
Heated Water
Non -Circulating Runouts
Circulating
Mains and Runouts
Temperature (F)
PP to 1„
Up to 1.25"
1.5" to 2.0"
Over 2"
170-180
0.5
1.0
1.5
2.0
140-160
0.5
0.5
1.0
1.5
100-130
0.5
0.5
0.5
1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes.
Fluid Temp. Insulation Thickness in Inches by Pipe Sizes
Piping System Types Range F 2" Runouts l" and Less 1.25" to 2" 2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant,
40-55
0.5
0.5
0.75
1.0
and Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD (Building Department Use Only)
oaf 9 Wacce�r-
SPENCER J. BUCHANAN ASSOCIATES, INC.
Consulting Engineers
Bryan, Texas
206 North Sims, 778031P.0. Box 672, 776081(979) 822-3767
IN -PLACE DENSITY TEST RESULTS
CLIENT: KELLY BURT DOZER SJB PROJECT NO.: 030232
PROJECT: 1004 Muirfield Drlve
1 Af`ATInM. 4Uutcn noA
—_ —
DATE
TEST LOCATION
MOISTURE
CONTENT
%
DRY
DENSITY
f)
PERCENT
COMPACTION
MATERIAL
TYPE
05115/03
NorthAast comer, 2nd lift, RECHECK of
12.4
113.5
99.8 ""
A 7 7 ,
Test taken 5-13-03
05/15/03
Center, 2nd lift, RECHECK of Test taken 5
13.7
110.7
97.1
A
13-03
05/16/03
Southeast corer, 2nd lift, RECHECK of
13.0
111.3
97.6
A
Test taken 5-13-03
OPTIMUM
COMPACTION MOISTURE MAXIMUM
EFFORT CONTENT DRY (TENSITY MATERIAL TYPE
ASTM D 698 12.8% 114.0 pcf (A) Red Clayey sand
NOTE: So depth tested
TESTING ENGINEER
Zd Wt1bZ:01 >=00Z Z0 'unr Z08Z eIL 607 : 'ON XUJ 'ow 'd3zoa idnK Am3A : WOa3
.�: SPENCER J. BUCHANAN ASSOCIATES, INC.
Consulting Engineers
Bryan, Texas
206 North SIM3, 77803IP.O. Box 67Z 77$M(979) 822-3767
IN -PLACE DENSITY TEST RESULTS
CLIENT: KELLY BURT DOZER SJB PROJECT NO.: 030232
PROJECT: 1004 MuUOeld Drive
LOCATION_ HeuRa —d
TESTI.00ATION
Y019RB
CONTE7PNT
DRY
DENBrrY
PERCENT
COMPACTION
MATERIAL
TYPE
OR13103
Northeast comer, 2nd lift
12.1
104.5
91.7
A
W13/03
Center, 2nd lift
14.0
108.5
93.4
A
05/13/03
SOUtheast comer, 2nd lift
152
105.5
92.5
A
SPENCER J. BUCHANAN ASSOCIATES, INC.
Consutting Engineers
Bryan, Texas
2os North saw 77so31P.o. Box t172, 778W(979) 622.3767
IN -PLACE DENSITY TEST RESULTS
CLIENT: KELLY BURT DOZER SJB PROJECT NO.: 030232
PROJECT: 1004 MukfleJd Drive
Lf4rAT1ON• 14-- —d
DATE
TEST LOCATION
MOISTIRE
CONTENT
DRY
DENSITY
PERCENT CENT
AL MATERIALRI
.TERI
PE
05/09/03
North comer
12.2
108.9
95.5
A
OWN/03
Center
13.0
109.1
95.7
A
05MO/03
South side
11.8
109.3
96.9
A
OPTIMUM
COMPACTION MOISTURE MAXWLW
EFFORT CONTENT DRY DENSrrY MATERIAL TYPE
ASTM D 698 12.VA 114.0 pd (A) Red daisy wM
NOTE: 6- depth tested
STING ENGINEER