Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
RES2003-01779
PREPARED 3/04/04, 12:01:51 INSPECTION TICKET PAGE 1 City of College Station INSPECTOR: BUILDING INSPECTOR DATE 3/04/04 ------------------------------------------------------------------------------------------------ ADDRESS . : 4401 ROCKY MEADOWS DR SUBDIV: WOODLAND HILLS PH 1 CONTRACTOR : OAKWOOD CUSTOM HOMES PHONE : (979) 690-1504 OWNER : WOODLAND HILLS DEVELOPMENT LTD PHONE : PARCEL : 671200-0101-0300 APPL NUMBER: 03-00001779 RESIDENTIAL, 1 UNIT DETACHED NEW ------------------------------------------------------------------------------------------------ PERMIT: BLDG 00 BUILDING PERMIT REQUESTED INSP DESCRIPTION TYP/SQ COMPLETED RESULT RESULTS/COMMENTS ------------------------------------------------------------------------------------------------ B100 01 10/31/03 BI BLDG, FOUNDATION -SLAB TIME: 17:00 10/31/03 CA 10/30/2003 01:03 PM MALFORD afternoon on 10/31/03 1 02 11/03/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 11/03/03 DP 10/31/2003 01:05 PM MALFORD 11/03/2003 11:20 AM MALFORD no strings on setbacks , no slab ground missing corners bars @ bay window in center of back wall B100 03 11/04/03 TB BLDG, FOUNDATION -SLAB TIME: 17:00 11/03/03 AP 11/03/2003 01:17 PM GCARRILLO 11/03/2003 04:45 PM MALFORD strings on setbacks, ok. back left bay window rt. on slab ground front left side B115 01 12/11/03 OC BLDG, FRAMING TIME: 17:00 12/11/03 AP 1.3/11/2003 1002 AM GCARRILLO B130 01 12/16/03 TB BLDG, INSULATION TIME: 17:00 12/16/03 AP 12/16/2003 10:10 AM GCARRILLO B12 Ol 3/04/04 �!,AP LDG, FINAL TIME: 17:00 / 03/04/2004 08:22 AM MALFORD ' 4---------------------------------- COMMENTS AND NOTES ----------------------------- -----5 iv \\0 � 13� � � w f Permit Number MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release lb Checked WWte TITLE: OAKLAND 2 CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 10/15/03 DATE OF PLANS: 10/15/03 PROJECT INFORMATION: WOODLAND HILLS SUBDIVISION 4401 ROCKY MEADOWS DR, COLLEGE STATION, TEXAS LOT 30, BLOCK 1 COMPANY INFORMATION: OAKWOOD CUSTOM HOMEBUILDERS, L.L.C. NOTES: NEW CONSTRUCTION COMPLIANCE: Passes Maximum UA = 933 Your Home = 834 10.6% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R Value R Value U Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2351 30.0 0.0 82 Ceiling 2: Cathedral Ceiling (no attic) 150 19.0 0.0 8 Wall 1: Wood Frame, 16" o.c. 2455 13.0 0.0 157 Window 1: Metal Frame, Double Pane 450 0.670 302 Door 1: Glass 87 0.140 12 Slab 1: Unheated, 0.0' insul. 262 0.0 273 Air Conditioner 1: Electric Central Air,12 SEER Furnace 1: Forced Hot Air, 78 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in MECcheck Version 3.2 Release lb. Builder/Designer ^ Date / 0 / r� 3 MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release lb DATE: 10/15/03 TITLE: OAKLAND 2 Bldg. fit• Use Ceilings: [ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R 30.0 cavity insulation Comments: [ ] I 2. Ceiling 2: Cathedral Ceiling (no attic), R 19.0 cavity insulation Comments: I Above -Grade Walls: [ ] I I. Wall 1: Wood Frame, 16" o.c., R 13.0 cavity insulation Comments: I Windows: [ ] I 1. Window 1: Metal Frame, Double Pane, U-factor: 0.670 For windows without labeled U factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No I Comments: i I Door's: [ ] I 1. Door 1: Glass, U-factor: 0.140 # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: I Slab -On -Grade Floors: [ ] I 1. Slab 1: Unheated, R 0 (uninsulated) Comments: Heating and Cooling Equipment: [ ] I 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number [ ] I 2. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number I [ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed [ ] I Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. I Materials Identification: [ ] I Materials and equipment must be installed in accordint to the manufacturer's installation instructions. [ ] I Materials and equipment must be identified so that compliance can be determined. L l I Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. [ ] I Insulation R values, glazing U-values, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Dart Insulation: [ ) I Ducts in unconditioned spaces must be insulated to R 5. Ducts outside the building must be insulated to R 8.0. Duct Construction: L ) I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] I Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] I Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] I The HVAC system must provide a means for balancing air and water systems. I Temperature Controls: ( ] I Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. I Service Water Heating: [ ] I Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] I Insulate circulating hot water pipes to the levels in Table 1. I Swimming Pools: [ ] I All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. I Heating and Cooling Piping Insulation: [ ) I HVAC piping conveying fluids above 105 T or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature (F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Tye Range ( F) 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) City of College S* 'ion WORK QUEST PAGE 1 RA,JOB: WF0468971 / 001 PROJECT: REQUEST DATE: 10/23/03 PRINT DATE: 10/23/03 CREW: PRINT TIME: 11:36:39 SCHSTAARRT.DA10/23/03 LOCATION: 4401 ROCKY MEADOWS DR 77845 COMPLETION: 10723703 GEN. LOC: COLLEGE STATION LOC ID: 190582 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN USER ID: MALFORD AUTH: MALFORD WORK TYPE: ROUTINE TEMP POLE PASSED TEMP POLE PASSED Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE 14 -a CITY OF COLLEGE STATION WORF 3QUEST REQ/JOB: WF0414165 / 001 PROJECT: CREW: PAGE 1 REQUEST DATE: 6/03/03 PRINT DATE: 6/03703 PRINT TIME: 10:40:11 LOCATION: 4401 ROCKY MEADOWS DR SCHEDULE START:DATES 6/03/03 77845 COMPLETION: 6/03103 GEN. LOC: COLLEGE STATION LOC ID: 190582 REF NBR: REQ DEPT: DE -BUILDING INSPECTION PRIORITY: NORMAL REQUESTOR: OAKWOOD CUSTOM HOMES ORIGIN: CUSTOMER -WALK IN USER D: KELMENDORF AUTH: KELMENDORF WORK TYPE: ROUTINE 3I%4" WATER 4" SEWER 3/4" WATER 4" SEWER Category code CS -CUSTOMER SERVICES CSCS Task code: SET UP NEW UTILITY ACCT SET Facility ID Assigned Department: OT-CUSTOMER SERVICE • RMIT Im-STAT10 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: ------------------------------------------- (979)764-3570 FAX: (979)764-3496 --------------------------------- Application Number . . . . . .03-00001779 Date 6/03/03 Property Address . . . . . . 4401 ROCKY MEADOWS DR Property ID . . 671200-0101-0300 R # . . . . . . . . . . . . . R108681 Application description . . . RESIDENTIAL, 1 UNIT DETACHED NEW Subdivision Name . . . . . . WOODLAND HILLS PH 1 Property Use . . . . . . . . RESIDENTIAL Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 157872 Owner Contractor ------------------------ ------------------------ WOODLAND HILLS DEVELOPMENT LTD OAKWOOD CUSTOM HOMES 1700 BARAK IN ALTON OFCZARZAK BRYAN TX 778023311 PO BOX 9849 COLLEGE STATION TX 77842 (979) 690-1504 -------------------------- Structure Information ------------------------- Construction Type . . . . . COMBUSTIBLE (UNPROTECTED) Occupancy Type . . . . . . RESIDENTIAL -MULTI -FAMILY Other struct info . . . . . EXTERIOR WALL TYPE BRICK IMPACT/PRORATA FEES PAID NA FOUNDATION TYPE SLAB NUMBER OF GARAGE BAYS 2.00 TYPE OF GARAGE (ATT/DET) DET HEATED AREA 2392.00 INTERIOR WALL TYPE DRYWALL NUMBER OF BATHROOMS 3.00 NUMBER OF BEDROOMS 4.00 SEWER TYPE PUBLIC SERIAL ZONES 253.00 ---------------------------------------------------------------------------- Permit . . . . . . BUILDING PERMIT Additional desc . . KE Permit Fee . . . . 634.00 Plan Check Fee .00 Issue Date . . . . 6/03/03 Valuation 157872 Expiration Date . . 11/30/03 Qty Unit Charge Per Extension BASE FEE 460.00 58.00 3.0000 THOU BLDG, VAL 100001-500000 174.00 ---------------------------------------------------------------------------- Special Notes and Comments ALL BRANCH CIRCUITS THAT SUPPLY RECEPTACLES IN DWELLING UNIT BEDROOMS SHALL BE PROTECTED BY AN ARC -FAULT CIRCUIT INTERRUPTERS) BUILDING DEPT REPRESENTAT VE: APPLICANT: BUILDING PERMIT CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 Application Number . . . . . 03-00001779 Page 2 Date 6/03/03 Special Notes and Comments PROVIDE ATTIC ACCESS WITHIN 20 FEET OF MECHANICAL EQUIPMENT PROVIDE CHEMICAL SOIL TREATMENT OR PHYSICAL BARRIER (SUCH AS METAL OR PLASTIC TERMITE SHIELDS) FOR PROTECTION AGAINST TERMITES. IF CHEMICAL TREATMENT IS USED, THE - CONCENTRATION, RATE OF APPLICATION AND TREATMENT METHOD SHALL BE CONSISTENT WITH THE TERMITICIDE LABEL. PROVIDE COMBUSTION AIR FOR GAS FIRED APPLIANCES PER CHAPTER 17, 2000 INTERNATIONAL RESIDENTIAL CODE ELECTRICAL SHALL BE INSTALLED PER 199 NEC & LOCAL AMENDMENTS ALL FRAMING SHALL COMPLY WITH 2O00 INTERNATIONAL RESIDENTIAL CODE PROVIDE ENGINEERED BEAM FOR GARAGE DOOR HEADER ATTACHED GARAGES SHALL HAVE ALL TOP PLATE AND HEADER PENETRATIONS SEALED PLATFORM FOR MECHANICAL EQUIPMENT AND/OR ACCESS MAY HAVE TO BE ELEVATED TO ALLOW FOR ATTIC INSULATION IF LAWN SPRINKLER IS PROVIDED, PERMIT MUST BE ISSUED PRIOR TO CERTIFICATE OF OCCUPANCY. CONSTRUCTION ACTIVITY BETWEEN THE HOURS OF 10:00 PM AND 7:00 AM MUST COMPLY WITH THE NOISE ORDINANCE (MAX. 55 DBA) POST PERMIT CARD ON JOB SITE WHEN WATER MAIN PRESSURE EXCEEDS 80 PSI, AN APPROVED PRESSURE REDUCING VALVE SHALL BE PROVIDED THAT LIMITS THE MAXIMUM STATIC WATER PRESSURE TO 80 PSI RECESSED LIGHTING INSTALLED IN THE BUILDING ENVELOPE SHALL BE IC RATED AND SEALED TO PREVENT AIR LEAKAGE PROVIDE SANITARY FACILITIES FOR WORKERS ON SITE LOCATED OFF THE PUBLIC RIGHT-OF-WAY. ADD SMOKE DETECTOR(S) PER NOTES ON PLANS PROVIDE STRING LINES FOR ALL BUILDING SETBACKS AND EASEMENTS ON FOUNDATION INSPECTION. THE COMBINED SOLAR HEAT GAIN COEFFICIENT OF ALL GLAZED FENESTRATION PRODUCTS SHALL NOT EXCEED .4 SMOKE DETECTORS SHALL BE INTERCONNECTED, 120 VOLT W/BATTERY BACKUP AND LOCATED IN EACH SLEEPING ROOM AND OUTSIDE EACH SEPARATE SLEEPING AREA IN THE IMMEDIATE VICINITY OF THE BEDROOMS REMOVE ALL VEGETATION AND FOREIGN MATERIAL FROM SLAB AREA PRIOR TO PLACING FILL. FILL SHALL BE FREE FROM VEGETATION AND FOREIGN MATERIAL. WINDOWS ADJACENT TO TUBS SHALL BE TEMPERED GLASS TEMPERED GLASS REQUIRED WITHIN 24" OF DOORS , - BUILDING PERMIT CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979)764-3570 FAX: (979)764-3496 ---------------------------------------------------------------------------- Page 3 Application Number . . . . . 03-00001779 Date 6/03/03 ---------------------------------------------------------------------------- Special Notes and Comments AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL SHALL BE PROVIDED FOR BUILDINGS UTILIZING STORAGE WATER HEATING EQUIPMENT AND A PRESSURE REDUCING VALVE GAS APPLIANCES HAVING AN IGNITION SOURCE SHALL BE ELEVATED SUCH THAT THE IGNITION SOURCE IS 18" ABOVE THE FLOOR IN PRIVATE GARAGES ---------------------------------------------------------------------------- Other Fees . . . . . . . . . SEWER TAP 4" CITY INSTALL 350.00 WATER TAP 3/4" CITY INSTL 400.00 Fee summary Charged Permit Fee Total 634.00 Plan Check Total .00 Other Fee Total 750.00 Grand Total 1384.00 Paid Credited Due ------------------------------ 634.00 .00 .00 .00 .00 .00 750.00 .00 .00 1384.00 .00 .00 BUILDING DEPT REPRESENTATIVE: APPLICANT: TEMPORARY POLE PERMIT CITY OF COLLEGE STATIO 1101 TEXAS AVE COLLEGE STATION, TX 77840 PHONE: (979) 764-3570 FAX: (979) 764-3496 ---------------------------------------------------------------------------- Application Number . . . . . 03-00001780 Date 6/03/03 Property Address . . . . . . 4401 ROCKY MEADOWS DR Property ID . . 671200-0101-0300 R # . . . . . . . . . . . . . R108681 Application description . . . TEMP POLE Subdivision Name . . . . . . WOODLAND HILLS PH 1 Property Use . . . . . . . . RESIDENTIAL _ Property Zoning . . . . . . . SINGLE FAMILY RESIDENTIAL Application valuation . . . . 0 Owner Contractor ------------------------ ------------------------ WOODLAND HILLS DEVELOPMENT LTD OAKWOOD CUSTOM HOMES 1700 BARAK LN ALTON OFCZARZAK BRYAN TX 778023311 PO BOX 9849 COLLEGE STATION TX 77842 (979) 690-1504 ---------------------------------------------------------------------------- Permit . . . . . . TEMP POLE PERMIT Additional desc . . KE Permit Fee . . . . 20.00 Issue Date . . . . 6/03/03 Valuation . . . . 0 ---------------------------------------------------------------------------- Other Fees . . . . . . . . . TEMP ELECT POLE CONNECT 45.00 Fee summary ----------------- Permit Fee Total Other Fee Total Grand Total Charged Paid -------------------- 20.00 20.00 45.00 45.00 65.00 65.00 Credited Due -------------------- .00 .00 .00 .00 .00 .00 ------------------------------------ t► BUILDING DEPT REPRESENTATIVE: - APPLICANT: APrLICATION FOR BUILDING PERM( CITY OF COLLEGE STATION 1101 TEXAS AVENUE COLLEGE STATION, TX 77840 (979) 764-3570 (979) 764-3496 FAX W W W.CI.COULEGE-STATION.TX.US a arm. vx ory DATE. ©i3 APPLICATION #A. — TEMP POLE # r ADDRESS/LOCATION: #4/0/ to 0?1?r� Mr�►oo.as LOT —3Q— BLOCK SUBDIVISION W"46Q M-11k BUSINESS/OWNER NAME: e.&S DA! 4gjy �',eu/iJ,0 k PHONE: &V-/3-Dtl CONTRACTOR/HOMEOWNER: Q009 PHONE: CONTRACTOR ADDRESS: Ap. Qax gjfV$ CIS 7Z-'j7AP41z. ELECTRICIAN: A4$fP/Sw PLUMBER: #~1e'44.✓a HVAC:GOOD CENTS (Residential only): �JG' CLASS OF WORK ACCESSORY/STORAGE LOCATION RE -ROOF (Total/Partial) ADDITION MOVING SHELL ONLY DEMOLITION (Asbestos Survey) EW CONSTRUCTION SLAB ONLY DUPLEX (Landscape Plans Req) REMODEURENOVATION SWIMMING POOL DESCRIPTION OF WORK: A/E7o IAP"4dr STRUCTURE USE: .49A✓f9(e F,ri+u« HOMEOWNER ASSOCIATIONIARCHITECTUAL OR DESIGN REVIEW COMMITTEE APPROVAL: TEXAS ACCESSIBILITY STANDARD (fAS) PROJECT REGISTRATION# EABPRJ VALUATION: $ 13s� 00o TOTAL AREA: y2 � HEATED AREA: 2302 (Cost of Labor find Materials) �PUBUC SEWER SEPTIC/TREATMENT SYSTEM SEWER TAP: SRE ti WATER TAP: SIZE OTHER TAP: S¢E Eg-TEMP POLE GARAGE TYPE: SINGLE ATTACHED• SIGNATURE OF APPLICANT. Plans Examiner NUMBER OF BEDROOMS: NUMBER OF BATHROOMS: —sue INTERIOR WALL TYPE: EXTERIOR WALL TYPE: FOUNDATION TYPE: ROOF TYPE: BLE Ell" TRIPLE 010clal Use Only DP..tr G.nf-�C. 09/z eUc- ED a Comments. YES or NO Zoning Official Energy Code Compliance Information % Glazing of exterior walls tj?i Insulation R value of exterior walls" / 3 Insulation R value of ceiling 1 (flat areas) 3© Insulation R value of ceiling 2 (vaulted areas/no attic) Glazing SHGC 13 q Glazing U-Factor • (P? R value of ductwork 4 A/C SEER rating t 2 * S4729'21'E-189.16' I OAKWOOD CUSTOM HOMEBUILDERS WOODLAND HILLS 20' P.U.E. COLLEGE STATION. TEXAS ao Lu 25' BUILDING LINE W I :3 SSCAI.E• N ET . ,+ �� za aJ °" m LOT 30R z N BLOCK 1 N eo Pik N �a u ui O C M 0 . F :a 2s 00, s .:.:.:.:.o 25 BUILDING LINE 6, 500 fe /jEt 4401 o ass DR. ti 19 o" Permit Number MECcheck Compliance Report 2000 IECC MECcheck Software Version 3.2 Release I Checked By/Date TITLE: OAKLAND CITY: College Station STATE: Texas HDD: 1788 CONSTRUCTION TYPE: Single Family DATE: 05/30/03 DATE OF PLANS: 05/28/03 PROJECT INFORMATION: WOODLAND HILLS SUBDIVISION 4401 ROCKY MEADOWS DR. COLLEGE STATION, TEXAS LOT 30, BLOCK 1 COMPANY INFORMATION: OAKWOOD CUSTOM HONIEBUILDERS, L.L.C. NOTES: NEW CONSTRUCTION COMPLIANCE: Passes Maximum UA = 906 Your Home = 804 11.3% Better Than Code Gross Glazing Area or Cavity Cont. or Door Perimeter R-Value R-Value U-Factor UA Ceiling 1: Flat Ceiling or Scissor Truss 2242 30.0 0.0 78 Ceiling 2: Cathedral Ceiling (no attic) 150 19.0 0.0 8 Wall 1: Wood Frame, 16" o.c. 2439 13.0 0.0 157 Window 1: Metal Frame, Double Pane 438 0.670 293 Door 1: Glass 87 0.140 12 Slab 1: Unheated, 0.0' insul. 246 0.0 256 Air Conditioner 1: Electric Central Air, 12 SEER Furnace 1: Forced Hot Air, 78 AFUE COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in MECcheck Version 3.2 Release Ib. Builder/Designer v" r �, Date 30 0 3 r MECcheck Inspection Checklist 2000 IECC MECcheck Software Version 3.2 Release 1 b DATE: 05/30/03 TITLE: OAKLAND Bldg. Dept. Use Ceilings: [ ] I 1. Ceiling 1: Flat Ceiling or Scissor Truss, R-30.0 cavity insulation Comments: [ ] I 2. Ceiling 2: Cathedral Ceiling (no attic), R-19.0 cavity insulation Comments: I Above -Grade Walls: [ ] I 1. Wall 1: Wood Frame, 16" o.c., R-13.0 cavity insulation Comments: I Windows: [ ] I 1. Window 1: Metal Frame, Double Pane, U-factor: 0.670 For windows without labeled U-factors, describe features: # Panes Frame Type Thermal Break? [ ] Yes [ ] No Comments: I Doors: [ ] I 1. Door 1: Glass, U factor: 0.140 # Panes Frame Type Thermal Break? [ ] Yes [ j No Comments: I Slab -On -Grade Floors: [ ] I 1. Slab 1: Unheated, R-0 (uninsulated) Comments: I Heating and Cooling Equipment: [ ] I 1. Air Conditioner 1: Electric Central Air, 12 SEER or higher Make and Model Number [ ] I 2. Furnace 1: Forced Hot Air, 78 AFUE or higher Make and Model Number I [ ] I The area -weighted average Solar Heat Gain Coefficient (SHGC) of all glazing cannot exceed 0.4. SHGC values must be determined in accordance with the NFRC test procedure or taken from the default table. I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. [ ] I Recessed lights must be type IC rated and installed with no penetrations or installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials and 3" clearance from insulation. I Materials Identification: Materials and equipment must be installed in accordint to the manufacturer's installation instructions. Materials and equipment must be identified so that compliance can be determined. Manufacturer manuals for all installed heating and cooling equipment and service water heating equipment must be provided. Insulation R-values, glazing U-values, and cooling equipment efficiency must be clearly marked on the building plans or specifications. Duct Insulation: [ ] Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: [ ] I All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Duct tape is not permitted. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). [ ] Ducts shall be supported every 10 feet or in accordance with the manufacturer's instructions. [ ] Cooling ducts with exterior insulation must be covered with a vapor retarder. [ ] I Air filters are required in the return air system. [ ] The HVAC system must provide a means for balancing air and water systems. Temperature Controls: [ ] Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: [ ] Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. [ ] Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: [ ] All heated swimming pools must have an on/offheater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: [ ] HVAC piping conveying fluids above 105'F or chilled fluids below 55 °F must be insulated to the levels in Table 2. Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes. Insulation Thickness in Inches by Pipe Sizes Heated Water Non -Circulating Runouts Circulating Mains and Runouts Temperature ( F) Up to P Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-160 0.5 0.5 1.0 1.5 100-130 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes. Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Tye Range F 2" Runouts 1" and Less 1.25" to 2" 2.5" to 4" Heating Systems Low PressureJTemperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant, 40-55 0.5 0.5 0.75 1.0 and Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD (Building Department Use Only) _ ,, - - _ - - _> , - �F , - - - - _ _ _ ^ _'I' _ _ _ _ _ - - - _ " - - 's - __ 6e ',�- - ,,ir - - ' z c �' •.1 ,r, ,� t' _ ii, YrJ 1*'•A, r ,I , ': 0 " I" " , - . � , , . , � - _ _ _ _ - _ .' is - - 4'.7 - - _ _ - - - t,. - - - - - _ r, - ;1 _ fir':'- - "`1' - _ = L . E. ,, T l�' �D t" i�T�'S ' '; _ _ - - - - -2, - - - - .:'. - - - - I. -LS. - - _ - - M^ - - - - .I 4C` , C; d �ry ASS` i`� �M �� 'ti Z 15Wtrut� `- `N,'. ' ToEI` i� Dt' C4 4 •y=' - i-fit, i"' - -•'1' - a:. - .m.r'. _ �' _ d• z `.' by •o , iFVI�I 'i;0#Q Nit �( I. t .1' -A ' - _ _ _ - _ y� _ t•, - _ �V� ", }. - - - ';', - - - __ - - y� - _ r�]K .4.. - _ ,i _ - .4 - _ ,� _ - - �I,d Q, _ _ 'y,'' i' T u _ �)yr �r A1�,j yr+ T. •!+��� " I..gr.._ e ".y " _i 'i Y -r - _ B 1•.t' - _ _ _ - vl A.., f�' -y:• M T F y' �, �:. r. iti J T l "- t yi !/I it �1Qti ; y •" r i{ /� F , 'A t' - / W1 •wl1 'Y 1' l - - - - _ / <' �i.- N' .{per . wV " f � _ - "4'... M1. - _ - "-{ cif 'h t• ' - - - ,11,' ,,,4 - - " T :"1+. ,I " `'" 3 IA 11 DA _ _ _ _ _ _ _ .L • _ _ ii> Nz;'. i r'. - _ 1WiV C S di `o�,ed' - � tY ;, =, +:' %' a`- i3• V h �My�T Y 4 `1p 1�J/y 11� d "a lY'� ,1 ��1� iF " �y�.�,�� 1� t , i+, 1 .t_ "_ _ _ 5' _ _ _ _ 3 f i J' - _ S _ _ _ _ r{vlvr - _ _ _ i i , - - - __ - --4''y - - ___ - - ` M, 4 W".• I "F 4; " -; - -.T-- - , - - - .v"' - -'y ni - - '`: k y' r ,, k'L , • w iie ', va[ 's ��.µµ �"�jj- ss��jj ')•' r - - - - yy ��, - - l- 1] YY y.. ,�$F ld =t, n ' ' [ '6 it ,, 3- „F,' a - 'fir 1 '!: ". - - - _r - - •r-. C Y tlliRg - r�li �C11gS$ . J, - J = , Eil �j�� .N(��ffii �{IY>L fjj��' - r w•ia' pi 11' - p d Vr" "'d`' rD trl� i Oar �� - �:i}Ti' _ >t •gin-�-'r " .; #� �. ,', . ;r-, {F. ' n ,l e 'i nia u N, ; Be�i� _ _ _ - _ _ __ 5," _ - _ _ - +�r :' y, ,ti' t • - �- '7 4 ` 1 ;;_r S, r - y h' ''ww'; ,' _ _ _ - j� _ _ _ a' .' Me }�l '}� r' •: ^•s.-..-ter-' _ +�t.1. i - - „I t %i - ��a - 1 rl.' :1-���y"FVY.t _ Y1 t„Q' r '!^'i• f4av - �J�ll4' . �. •.'.Ta' �y 1 , ,•• iMt. ;h i �'t� i 11 U{7 ,R'• - 'tr 1� whY' - - - " ';�lii' ��,z, ,�--, - 'i, _ ::.; . J F _ _ .,f _ - - - t_i - - - A' t} :I _ - _ Q'� __�J �� _ - _ _ _ S, _ _ _ _ _r(j�-�'_ A7 i - I� 7 ar ,I _ - ;- b 't, - ~L' - r'r , r f '. `5 n iu�,T ." - �t iL - ea _ - - ,� - 1. • - - 1, v. - - - - 'ti - r`r _ _ - _ ,,,, _ - - „�� � , _ _ - _ _ a' r,. l o v 6�' ! /�r;, ;. e I%Jn� _ t!�*i . ' ` ill a P :..-_ �1_ r Y�VA�:-G�tutcit�r•`•'�''V �`rYfrt�''�"f • '':?j P , - `. - 1 - - - - - _ r,V" ter•, 0 y • _` j ar tebait� Cheetc b1E TD'' � � 1 v .21" - - - - - C ",I. - i4i}- - A` n iI s, x. r � 4 tY `cictres's: � J • I' ';-Y' ;R r_ '� ,-� t, ; +' ;: - ,„`, , ,.' — _ i" - ;,,..: , - a:- ,it, :% �` - - '.T, , i,_, r - _ -,l - :4 }".' xr`• :1' w City of College Station Good Cents Qualifying Criteria GOOD CENTS,' College Station's Energy Efficiency Program for new homes, is a flexible, performance - based program that allows the future homeowner and homebuilder various combinations of energy efficient, thermal and mechanical components to meet the Good Cents heat gain and aif infiltration requirements. HEAT GAIN Analyses are performed on the construction•plans when submitted with the proper application at the College Station Public Utility Energy Management offices at 1601 Graham Road in College Station.- Maximum allowable calculated heat gain of 12.0 BTU's or less are required to qualify for, the Good Cents Program. Energy Management personnel are available to work with owners and builders to assist in meeting -criteria. INSULATION / INFILTRATION ; Insulation resistance values are to meet or exceed R-13 in warts, R 30 in attics and R-19 for pier and beam floors. Upon completion of insulation installation and before drywall and/or brick and siding are installed, Energy Management personnel must be notified to perform a thorough insulation/infiltration inspection. All insulation must be installed according to the manufacturer's instructions and CUT tightly around all junction boxes and plumbing filling the entire stud area with no gaps. Insulation must be installed during framing behind all -tee$ and comers and behind any bathtub stalls installed before inspection. Appropriate R-value batts must be installed before first inspection in all ceilings areas impossible to reach during attic insulation installations. A minimum of :" insulating sheathing must be installed over exterior walls including wind bracing. All sheathing joints must be sealed with thermal sheathing tape. Sole plates 'must be caulked and all plumbing, electrical, security'and cable entries must be sealed at the top plate and at any sheathing intersections. All - gaps and, penetrations in the thermal envelope must be sealed.' All, windows must be double -glazed. Low E glass is recommended but is not a requirement. Solar screens are encouraged but will not be included in heat gain analyses since they are not fixed. Windows must be sealed with expanding foam and the exterior taped with sheathing/window tape. All exterior doors must be solid wood, molded fiberglass, or metal polystyrene, urethane or fiberglass filled. Weather-stripping of all doors and windows must be completed before final inspection including any . interior attic access doors within the conditioned space., HEATING / AIR CONDITIONING / VENTI LATION Air conditioning systems must have 12.0 or better SEER ratings and gas furnaces a minimum of SO ' AFUE• ratings.. Heat pumps systems must have a minimum of 12.0 SEER and 3.0 COP efficiency ratings with back-up resistance heating not to exceed 5 kW per ton. The maximum allowable . capacity for any installation shall not exceed one ton per 600 square feet of conditioned area. Wall return air chases must be internally lined with drywall or duct board sealed at all joints and at the floor. Ceiling return air plenums must be sealed at ceiling rafters or -header plate'_ Kitchen and bathroom exhaust fans must be dampered and ducted'to-exterior: Fireplaces, other than vent free gas units, must have fire blocks and outside combustion air intakes installed at time of initial inspection. Ridge vents with'appropriate numbers and sizes of soffit vents are required. Roof designs providing little . ridge vent shall. install additional turbine, gable -or powered vents to provide adequate ventilation. REBATES FOR HOMES PASSING ALL HEAT GAIN, INSULATION & BLOWER DOOR INSPECTIONS: CAPACITY SEER BTU's RATING 12 13 14 - 15 16 18 To 41,999 $400.00 $400.00 $400.00 $400.00 - $600.00 $600.00 42,000'to 60,000 $400.00 $400.00 $600.00 $600.00 $600.00 $800.00